Manuscript Offprint

arXiv:2611.24644

Equal Steps, Unequal Curvature: Where Muon's Update Goes Wrong

Biswa Sengupta, Jinhua Wang, Léo Maxime Brunswic

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Abstract

Muon updates each hidden weight matrix along the polar factor of its momentum, the steepest-descent direction under the spectral norm. That choice fixes two allocations without consulting the loss: every singular direction of the momentum receives the same step, and in a non-square matrix each neuron’s step is set by its leverage score. Whether these allocations are good is a question about curvature, which steepest-descent arguments do not answer. We measure it. Using held-out gradients and Hessian–vector products, we decompose Muon’s step by singular-value band and by neuron group and compute each group’s second-order optimal multiplier. In a 124M-parameter decoder trained on FineWeb-Edu, the multipliers rise monotonically from the top singular directions to the tail: Muon over-steps the high-curvature top of its spectrum. We prove in Lean when such a diagnostic licenses an intervention at Muon’s own update norm. Applied to the measured curvature, the criterion predicts, and direct measurements of the held-out loss confirm, that moving step length off the top improves the one-step loss severalfold mid-training and at the start of the cooldown, but not at its end. We then test interventions under per-step norm matching, tuned baselines and paired seeds. Orthogonalizing Q, K and V separately rather than as one fused matrix lowers the loss by 0.0250 nats and accounts for all of the gain of block-wise variants. A matmul-only, rotation-equivariant spectral tilt σ−1/4\sigma^{-1/4} applied in the cooldown lowers the loss of this stronger baseline by a further 0.0120 nats, additively with NorMuon (0.0158 nats together, three seeds; the baseline needs about 4.3% more tokens to match), and by 0.0188 nats at 355M parameters (three seeds). Energy-matched Schatten-1 weight decay adds a further 0.0052 nats. Geometrically principled changes that do not act on the measured miscalibration, namely exact polar factors, steepest-descent input whitening and top-heavy decay, do not help.

Keywords:

Muon, optimization, orthogonalized updates, curvature, language models, Lean

\icmlauthorblock

Biswa Sengupta Jinhua Wang Léo Maxime Brunswic LLM Suite Team, JPMorgan Chase & Co. {biswa.sengupta, jinhua.wang, leo.brunswic}@jpmorgan.com \icmlcopyright© 2026 JP Morgan Chase & Co. All rights reserved

.

References (55)