Manuscript Offprint

arXiv:2608.28092

Do Medical Vision Models Reason About Anatomy? Probing the Spatial Inductive Biases of Learned Visual Representations

Naren Akash, Neeraja Ramanan

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original. This text is shared under the same licence.

Naren Akash 1,2^{1,2} and Neeraja Ramanan 1,2^{1,2}

1^{1} Center for Visual Information Technology, IIIT Hyderabad, Hyderabad, India

2^{2} Center for AI and Innovation, AIG Hospitals, Hyderabad, India

naren.akash@research.iiit.ac.in

Abstract. Interpreting a CT scan means comparing structures on either side, judging how far apart organs sit, and knowing where each one belongs. Medical vision encoders are evaluated on diagnostic accuracy, or through assembled multimodal systems where a failure is hard to attribute, so it remains unclear whether their representations support any of this. We construct SPAR-Bench, eight probes over multi-organ abdominal CT that separate coordinate localization, relational reasoning, and spatial queries, and apply them to five architectural configurations and three medical foundation models, frozen and finetuned. Probes that ask for a comparison within the slice stay at chance, and neither pretraining scale, finetuning, nor architecture closes the gap. Probes that appear solved in domain fall to chance under zero-shot transfer, indicating that their accuracy reflects recall of canonical anatomy rather than computation over the image. Reading the same frozen features with a pooled head rather than the full set of tokens moves relational recovery from 0.7% to 67.8%, so pooled probing understates what a representation holds. Questions the encoders answer well are answered at chance by four open-weight MLLMs. Our results suggest these encoders carry a map of where organs usually lie, and little of the machinery for comparing structures within a particular patient. Code and data will be available at spar-bench.github.io.

Keywords: Spatial Reasoning · Medical Imaging · Foundation Models.

1 Introduction

Radiological diagnosis depends on the spatial coordination of anatomical structures. A finding's clinical significance is often determined by its position within a canonical spatial map, its proximity to adjacent landmarks, and its appearance relative to the contralateral side. Implicit in expert interpretation is the utilization of this map: staging a pancreatic mass requires quantifying its contact with the superior mesenteric artery [1].

Models are scored on the diagnosis they output. A diagnostic label, however, sits at the end of a chain of simpler judgements, and reaching it requires

N. Akash et al.

composing several of them, including the presence of some features and the confirmed absence of others. Screening for renal artery stenosis turns on whether the two kidneys differ in size [32], which requires locating both, measuring each, and comparing the two. Accuracy on the final label scores the composition and leaves the elements it was built from untested, so a model can reach the correct finding through texture or context while representing none of the underlying geometry [2]. The same gap appears in evaluations of medical multimodal LLMs, which report failures on image orientation and on judging which of two slices lies closer to a landmark [7], and answers that flip between visually similar image pairs [8]. Both evaluate assembled systems, in which a wrong answer can originate in the encoder, the projection layer, or the language model. We instead probe the elements, and probe them in the vision encoder alone.

Prior work has characterized the spatial properties of vision architectures primarily from two directions. First, representation analyses show that Vision Transformers (ViTs) preserve spatial information in tokens across layers more uniformly than CNNs [3], and show superior robustness to patch-level permutations [4]. Second, self-supervised methods in medical imaging largely utilize spatial disruption, such as shuffling, masking, or rearranging patches, as pretext signals to encourage anatomical representation learning. Both lines focus on representation preservation or reconstructive robustness rather than functional reasoning. Existing benchmarks evaluate basic perception in medical multimodal LLMs [7,8] or analyze natural vision models [5,6], but none quantify whether a vision encoder can compute over anatomical spatial structure.

We introduce SPAR-Bench (Spatial Anatomical Reasoning Benchmark), which probes spatial competency in vision encoders through three hierarchical levels. Localization tests whether models can predict organ centroid coordinates. Relational Reasoning tests whether models can reconstruct shuffled anatomical tiles. Spatial Queries test whether models can answer six question types spanning relative position, symmetry, size, distance, and counting. Using multi-organ abdominal CT as a testbed, we evaluate five architectural configurations and three medical foundation models as frozen encoders with lightweight trainable heads and in fine-tuned settings. We further test zero-shot transfer to TotalSegmentator and pose the same spatial questions to four open-weight MLLMs.

We make four contributions. (i) We introduce SPAR-Bench, eight probes derived automatically from segmentation masks that separate localization, relational reasoning, and spatial queries. (ii) We show that bilateral symmetry stays at chance across all 13 configurations, under zero-shot transfer, and for the MLLMs we test, while relative position reaches 99% on WORD and falls to chance out of domain, which suggests the in-domain score reflects recall of canonical anatomy rather than a computation over the image. (iii) We show that reading the same frozen features with a pooled head rather than the full token sequence moves relational recovery from 0.7% to 67.8%, which affects how frozen-model evaluations should be read. (iv) We evaluate encoders and assembled MLLMs on the same questions and find that questions the encoders answer well are answered at chance by the MLLMs.

References (32)

  • Pancreatic Ductal Adenocarcinoma Radiology Reporting Template: Consensus Statement of the Society of Abdominal Radiology and the American Pancreatic Association
  • Shortcut Learning in Deep Neural Networks
  • Do Vision Transformers See Like Convolutional Neural Networks? In: Advances in Neural Information Processing Systems (NeurIPS)
  • Intriguing Properties of Vision Transformers
  • SpatialVLM: Endowing Vision-Language Models with Spatial Reasoning Capabilities
  • 3DSRBench: A Comprehensive 3D Spatial Reasoning Benchmark
  • MedBLINK: Probing Visual Perception in Multimodal Language Models for Medicine
  • MediConfusion: Can You Trust Your AI Radiologist? Probing the Reliability of Multimodal Medical Foundation Models
  • Unsupervised Learning of Visual Representations by Solving Jigsaw Puzzles
  • Self-supervised Feature Learning for 3D Medical Images by Playing a Rubik's Cube
  • Models Genesis: Generic Autodidactic Models for 3D Medical N. Akash et al. Image Analysis
  • Self-supervised Learning for Cardiac MR Image Segmentation by Anatomical Position Prediction
  • UniBench: Visual Reasoning Requires Rethinking Vision-Language Beyond Scaling
  • Exploring Scalable Medical Image Encoders Beyond Text Supervision
  • A Multimodal Biomedical Foundation Model Trained from Fifteen Million Image–Text Pairs
  • TransUNet: Rethinking the U-Net Architecture Design for Medical Image Segmentation Through the Lens of Transformers
  • Swin-Unet: Unet-Like Pure Transformer for Medical Image Segmentation
  • UNETR: Transformers for 3D Medical Image Segmentation
  • nnU-Net: A Self-Configuring Method for Deep Learning-Based Biomedical Image Segmentation
  • Deep Residual Learning for Image Recognition
  • An Image is Worth 16x16 Words: Transformers for Image Recognition at Scale
  • Concerning Nonnegative Matrices and Doubly Stochastic Matrices
  • The Hungarian Method for the Assignment Problem
  • WORD: A Large Scale Dataset, Benchmark and Clinical Applicable Study for Abdominal Organ Segmentation from CT Image
  • The Liver Tumor Segmentation Benchmark (LiTS)
  • Cheng, J., Ye, J., Deng, Z., Chen, J., Li, T., Wang, H., Su, Y., Huang, Z., Chen, J., Jiang, L., et al.: SAM-Med2D. arXiv preprint arXiv:2308.16184 (2023) (opens arXiv in a new tab)
  • TotalSegmentator: Robust Segmentation of 104 Anatomic Structures in CT Images
  • Improved Baselines with Visual Instruction Tuning
  • Qwen2-VL: Enhancing Vision-Language Model's Perception of the World at Any Resolution
  • MedGemma Technical Report (opens arXiv in a new tab)
  • Speciality vs Generality: An Empirical Study on Catastrophic Forgetting in Fine-Tuning Foundation Models (opens arXiv in a new tab)
  • A New Threshold for Kidney Asymmetry Improves Association with Abnormal Renal-Aortic Ratio for Diagnosis of Renal Artery Stenosis