Manuscript Offprint

arXiv:2608.28371

Real-Time Musculoskeletal Surrogates for Pediatric Cerebral Palsy: a Credibility Pilot

Mohammad Arif Ul Alam

Abstract

Real-time musculoskeletal (MSK) surrogates could support personalized rehabilitation for children with cerebral palsy (CP), but their credibility depends on subject-wise evaluation, low inference latency, and calibrated uncertainty. We develop a subject-conditioned causal neural surrogate using OpenSim-derived static parameters, temporal joint kinematics, true muscle capacities, and training-only perturbations. On a real pediatric CP gait dataset comprising nine children, we use leave-one-subject-out validation on six development subjects and evaluate a frozen configuration once on three locked test subjects. The surrogate accurately reproduces musculotendon lengths ( R2≈0.92R^{2} \approx 0.92 in development validation and ≈0.95\approx 0.95 on locked subjects; nRMSE < 8%) while requiring only sub-millisecond to few-millisecond neural inference, well below a 100 ms interactive-rehabilitation target. In contrast, direct muscle-force estimation remains unstable at this small, heterogeneous scale: pooled metrics can overstate within-subject, per-muscle accuracy. A Monte Carlo credibility pilot further shows that propagating only ±5%\pm 5\% anthropometry and muscle-capacity variation produces severely overconfident nominal 90% intervals (approximately 4% force coverage and below 1% MT-length coverage). These results establish a leakage-free evaluation and credibility framework for pediatric MSK surrogates, while identifying force modeling and epistemic uncertainty as the central next challenges for clinically credible digital twins.

Keywords: Pediatric cerebral palsy, Musculoskeletal modeling, Neural surrogates, Real-time rehabilitation, Credibility assessment

1. Introduction

Cerebral palsy (CP) is the leading cause of childhood physical disability and is associated with highly heterogeneous movement impairments Ros (2007). In particular, crouch gait changes joint loading, muscle recruitment, and the mechanical demands of walking, making patient-specific analysis important for clinical decision-making Steele et al. (2010). Musculoskeletal (MSK) simulation provides a noninvasive way to estimate quantities that cannot be measured directly during gait, including muscle forces, activations, and joint moments. OpenSim and subject-scaled full-body models have made these analyses broadly reproducible and clinically relevant Seth et al. (2018); Rajagopal et al. (2016). However, conventional muscle-driven simulations remain too computationally expensive for interactive rehabilitation or continuously updated digital twins.

Neural surrogates offer a practical route to real-time MSK analysis. Recent studies have used temporal neural networks and physics-informed objectives to estimate muscle forces or joint kinematics from motion and electromyography signals Zhang et al. (2022b); Liu et al. (2024); Zhang et al. (2022a). These results are promising, but most evidence is based on healthy adults, a small number of muscles, or task-specific datasets. Pediatric CP creates a more difficult setting because gait patterns, body dimensions, strength, and neuromuscular control vary substantially between children. Further, muscle force is not directly observed: it is an underdetermined model estimate whose value depends on the musculoskeletal model, optimization method, and physiological assumptions Roelker et al. (2020); Falisse et al. (2018). Consequently, a surrogate should be evaluated not only by a favorable frame-pooled score, but also by its ability to generalize across held-out children.

Credibility is equally important for clinical digital twins. ASME V&V 40 and recent FDA guidance emphasize that the evidence supporting a computational model should be appropriate for its intended context of use U.S. Food and Drug Administration (2023). This requires transparent data partitioning, validation on independent subjects, and explicit assessment of uncertainty rather than relying on point predictions alone. In this preliminary study, we develop a real-time, subject-conditioned MSK surrogate for pediatric CP gait and contribute: (i) a leakage-free evaluation protocol with leave-one-subject-out development validation and a locked held-out test set; (ii) a causal surrogate conditioned on OpenSim-derived static parameters and true muscle capacities; (iii) an honest characterization of the limitations of small-cohort muscle-force estimation; and (iv) a Monte Carlo credibility pilot showing that input-parameter propagation alone does not yield calibrated uncertainty. The subject-level cohort and evaluation partition are summarized in Table 1. Together, these results establish a rigorous experimental foundation for future credible pediatric MSK digital twins.

References (14)