arXiv:2608.22334stat.MLAug 2026

Manuscript Offprint

arXiv:2608.22334

Recovering Weighted Tangent Geometry from a Single-Scale Score Field

Ziqi Zhao, Qingjian Ni

Abstract

Near a smooth data manifold, one tangent space summarizes local geometry. At a branch point, the corresponding first-order object is instead a measure over tangent directions, whose normalized masses record the local share of each branch under the chosen data measure. We ask whether a score field at one noise level determines this weighted tangent geometry when the branch center and homogeneity degree dd are unknown. In this tangent-measure model, dd is the local measure dimension. Gaussian smoothing of a homogeneous tangent measure satisfies an Ornstein–Uhlenbeck eigenfunction equation. Its weak form turns score values—without score derivatives—into a linear system for the center and homogeneity degree, with an explicit rank condition and perturbation bound. After this calibration, the tangential score on one sphere is the spherical log-gradient of a scalar Gaussian–cone transform. Integration recovers that transform up to scale, and all its spherical-harmonic multipliers are positive. Thus one exact shell identifies the normalized angular measure in every ambient dimension D≥2D \geq 2. For at most KK positive rays, moments through degree 2K−12K - 1 constructively recover count, directions, and weights in arbitrary dimension. Any fixed observation scheme needs at least KD−1KD - 1 scalar tangential components. In the plane, degree KK is both sufficient and necessary, and we give quantitative finite-query certificates. For finite planar C1,βC^{1,\beta} branches with positive C0,βC^{0,\beta} densities, we prove O(σβ)O(\sigma^{\beta}) convergence from the finite-noise score to its tangent model. In controlled experiments, 50k-step training lowers validation normalized-score error across four geometries yet raises angular-moment error, separating ordinary score fit from geometry recovery.

1 Introduction

The score sσ(x)=∇xlog⁡(μ∗φσ)(x)s_{\sigma}(x) = \nabla_x \log(\mu * \varphi_{\sigma})(x) is a local vector field used by score-based generative models [24]. Near a smooth manifold, its normal component and Jacobian reveal tangent and normal spaces [25, 26]. Many supports are not smooth everywhere: trajectories merge, road segments intersect, and stratified spaces contain boundaries and junctions. No single tangent space describes such a

∗^{*}Corresponding author.

point. The first-order object is instead a normalized angular tangent measure. In a finite-ray model, its atoms record branch directions and their relative shares of local mass under the data measure.

We call the local scaling exponent the homogeneity degree; in our tangent model, it is the local measure dimension. We study an inverse question at one known noise level:

Can local score queries recover a branch point, its homogeneity degree, and the weighted tangent geometry represented by the field?

This differs from detecting a singularity in raw samples [11, 28]. A point-cloud method can identify a neighborhood worth auditing and estimate sample geometry, but it does not establish what a trained score field represents there. Conversely, a low denoising objective does not certify a center, homogeneity degree, branch count, directions, or mass. We therefore start from a local query window, not from an exactly supplied center; global singularity search remains a separate problem. Here one noise level refers to the available field used by this local inverse problem; training and sampling may still use a full noise schedule.

A one-point score Hessian is insufficient for branch geometry: at a conic vertex it depends only on the first two angular moments. Every uniform regular planar q-ray junction with q≥3q \geq 3 therefore has the same vertex Hessian, although different counts produce different score patterns away from the vertex. A separate trace identity does encode homogeneity, and its weak form lets a spatial score pattern first calibrate the unknown center and homogeneity degree. Once centered, one normalized shell contains the remaining angular information.

The recovery chain begins with weak score averages that calibrate the center and homogeneity degree. Tangential queries on the calibrated shell are then integrated into a normalized scalar density, whose harmonic coefficients yield angular moments. A finite-rank moment pencil reconstructs the branches. The procedure finally reports a numerical candidate, a certified stage, or abstention. The calibration and integration steps convert vector log-gradient observations into the centered scalar-moment interface assumed by spectral estimators.

For an exact homogeneous tangent model, the center, homogeneity, and normalized angular measure are recoverable in any D≥2D \geq 2 under explicit identifiability conditions. Quantitative discrete-query certificates are specialized to the plane, but exact finite-branch reconstruction is not. Our contributions are:

  1. Score-only center and homogeneity calibration. Homogeneity makes the smoothed conic density an Ornstein–Uhlenbeck eigenfunction. Testing its score equation against localized functions gives a linear system for the unknown center and degree d, without differentiating the score. Full column rank is sufficient, its failure captures translational symmetries, and a direct least-squares perturbation bound quantifies approximate fields.

  2. Constructive recovery in arbitrary dimension. In every D≥2D \geq 2, a centered exact shell identifies any finite positive angular measure. If it has at most K atoms, harmonic moments through degree 2K−12K - 1 form a finite-rank multivariate moment pencil whose rank, joint eigenvalues, and linear coefficients recover count, directions, and weights. A fixed scheme requires at least KD−1KD - 1 scalar tangential observations.

  3. Sharp planar recovery and conditional stability. For finite C1,βC^{1,\beta} planar branches with positive C0,βC^{0,\beta} densities, the tangent-score bias is O(σβ)O(\sigma^{\beta}) on fixed normalized query sets. For positive planar rays, moments through degree K suffice, whereas degree K-1 does not. Explicit finite-sampling aliasing and declared minimum weight, angular separation, and conditioning bounds yield sufficient count, direction, and weight tests.

  4. Finite-data and learned-score diagnostics. The error chain exposes tangent bias, local coverage, calibration error, harmonic amplification, network error, and query aliasing. Population, empirical kernel-density estimate (KDE), and learned fields pass through matched recovery stages. Long-horizon controls show that lower validation normalized-score error can coexist with higher angular-moment error and incomplete geometry recovery.

Classical spectral methods start from a scalar convolution or its moments. Our observation is instead an uncentered vector-valued log-gradient. The score-specific part of the pipeline removes the unknown center and homogeneity, recovers the scalar shell transform up to its irrelevant multiplicative constant, proves that the Gaussian-cone kernel has no harmonic nullspace, and propagates score-side errors to moments. The subsequent multivariate Prony, matrix-pencil, Toeplitz, and Vandermonde steps are classical [8, 9]. Our results concern local identifiability from an available score slice; global localization, multiscale necessity, and universality across diffusion architectures are outside scope. Appendix J and Section 7 discuss related boundary cases and limitations.

References (29)