Manuscript Offprint

arXiv:2608.22363

Analyzing and Mitigating Cross-Lingual Degradation in Multilingual Medical VQA

Jingbo Wang, Sendong Zhao, Haochun Wang, Bing Qin, Ting Liu

Abstract

Medical visual question answering (VQA) is a crucial task in clinical AI, yet its evaluation has so far centered almost exclusively on English, limiting its relevance to linguistically diverse patients and clinicians. Recent multilingual medical VQA benchmarks show that large vision-language models (LVLMs) degrade in non-English languages, but lack a fine-grained analysis of how cross-lingual variation affects the distinct capabilities that medical VQA requires. To this end, we construct a multilingual medical VQA benchmark over eight languages, organized into four representative scenarios that isolate the core capabilities medical VQA requires. Evaluating five open- and closed-source LVLMs, we find that cross-lingual degradation is not uniform but highly scenario-dependent. We therefore propose MedVL-XLRepE, a training-free scenario-aware representation engineering method, leveraging LVLMs' superior English medical VQA capability to steer non-English representations toward their English counterparts at inference time. Across three LVLMs and eight languages, MedVL-XLRepE consistently mitigates cross-lingual degradation, with gains of up to 6.33%.

1 Introduction

Medical visual question answering (VQA), which aims to interpret medical images and answer clinical queries, is a crucial research area in clinical AI (Lau et al., 2018; He et al., 2020; Li et al., 2023a). Driven by the rapid progress of large vision-language models (LVLMs) (Chen et al., 2024; DeepSeek-AI, 2026), recent systems have achieved substantial progress on medical VQA (Hu et al., 2024; Dong et al., 2025). Despite these remarkable advances, the medical evaluation of LVLMs has so far centered almost exclusively on English, which limits their applicability to a linguistically diverse population of patients and clinicians.

To evaluate whether LVLMs can serve multilingual populations, recent studies have constructed multilingual medical VQA benchmarks. These benchmarks draw medical images and questions from the national medical examinations and real-world clinical consultations of several countries, and evaluate the cross-lingual performance of LVLMs (Matos et al., 2024; Riccio et al., 2025; Yim et al., 2024b). Although these benchmarks show that the medical VQA performance of LVLMs degrades in non-English languages, their analysis of this degradation has two key limitations. First, they measure only the overall success rate on medical VQA, lacking fine-grained analysis of how cross-lingual variation affects the distinct capabilities that medical VQA requires. Second, their language coverage is limited, lacking analysis of how this degradation generalizes across a broader range of languages.

To address these limitations, we construct a multilingual medical VQA benchmark covering eight languages. Guided by the core capabilities that medical VQA requires (Lin et al., 2023; Pahud de Mortanges et al., 2024; Acosta et al., 2022), we organize the benchmark into four representative scenarios: Perceptual Recognition, Attribute-Aware Recognition, Sequential Images Understanding, and Vision-Text Integrated Reasoning, each isolating one such capability. Evaluations across five open- and closed-source LVLMs reveal that cross-lingual degradation is not uniform but highly scenario-dependent, indicating that language affects different medical reasoning capabilities unevenly. Such scenario-dependent cross-lingual degradation cannot be addressed by a single uniform correction, but requires a scenario-specific method instead.

To leverage the superior medical VQA capabilities of LVLMs in English for improving

∗^{*}Corresponding author.

non-English performance, we propose MedVL-XLRepE, a training-free, scenario-aware cross-lingual representation engineering method. For each scenario, MedVL-XLRepE leverages a language vector and scenario-specific medical vectors from the representation gap between parallel English and target-language inputs, steering non-English representations toward their English counterparts at inference time. Experiments across three LVLMs and eight languages show that MedVL-XLRepE achieves consistent improvements, with gains of up to 6.33%, demonstrating its effectiveness in mitigating cross-lingual degradation in medical VQA.

Our contributions are summarized as follows:

• We construct a multilingual medical VQA benchmark covering eight languages and organized into four scenarios that isolate the core capabilities medical VQA requires.

• We present a comprehensive analysis of multilingual medical VQA across open- and closed-source LVLMs, revealing that cross-lingual degradation is strongly scenario-dependent.

• We propose MedVL-XLRepE, a scenario-aware representation engineering method that effectively mitigates cross-lingual degradation in medical VQA.

References (24)