Manuscript Offprint
arXiv:2611.12526Galilean Robots, Aristotelian Sensors: Joint Spatiotemporal Trajectory Estimation and Extrinsic Calibration
Abhishek Goudar, Jonathan Kelly, Timothy D. Barfoot
Abstract—Multi-sensor state estimation requires accurate spatial and temporal calibration between heterogeneous sensors. Existing spatiotemporal calibration methods typically represent sensor extrinsic parameters as a rigid-body transformation together with a scalar temporal offset, causing the spatial and temporal parameters to enter the estimation problem through separate mechanisms. While the spatial transformation composes directly with the robot pose, accounting for the temporal offset requires evaluating the trajectory at a shifted time, typically through motion compensation, interpolation, or a continuous-time trajectory representation. In this work, we formulate joint trajectory estimation and spatiotemporal calibration using the special Galilean group for the robot trajectory and the Aristotelian subgroup for sensor extrinsics. This representation incorporates the coupling between motion and temporal offset directly through the group structure, avoiding the need for a separately parameterized continuous-time trajectory. We develop twist- and IMU-driven motion priors, accommodate both ideal and non-ideal clocks, and evaluate the framework with camera, position, and range measurements. Simulated and real experiments demonstrate calibration and trajectory-estimation performance comparable to established methods across heterogeneous sensor configurations. Our simplified framework therefore offers a quality-of-life improvement over existing methods without compromising performance.
Index Terms—Spatiotemporal calibration, special Galilean group, sensor fusion.
I. INTRODUCTION
Modern robotic platforms typically combine data from heterogeneous sensors, such as inertial measurement units (IMUs), cameras, lidars, and ranging radios. Fusing measurements from multiple sensors requires knowledge not only of their relative spatial configuration, but also of the times at which their measurements were acquired. Even when sensor clocks are synchronized, acquisition, processing, and communication delays can introduce temporal offsets between the reported timestamp and the underlying physical measurement event. Such offsets translate into spatial errors through the motion of the platform and can degrade the accuracy and consistency of state estimation [1], [2]. Consequently, spatiotemporal calibration, where inter-sensor spatial extrinsic parameters and temporal offsets are estimated jointly, is an important prerequisite for reliable multi-sensor fusion.
Existing approaches typically represent the extrinsic parameters as an element of [1], [2], [3]: a rigid-body transformation together with a scalar temporal offset. Under this representation, the spatial and temporal components enter the estimation problem through fundamentally
(a)

(b)
Fig. 1. Trajectory estimation and calibration using the special Galilean group. (a) The robot trajectory is represented by states , expressed with respect to the inertial reference frame . The robot body frame and the inertial measurement unit (IMU) are assumed to be co-located. The spatial and temporal transformations to the camera are represented by an element of the Aristotelian group . (b) The IMU and camera sample asynchronously with periods and . The camera measurements have a temporal offset relative to the IMU/reference clock and may additionally experience a delay before reaching the estimator. As a result, the measurement timestamps observed by the estimator can differ from physical measurement times. The sensor extrinsic parameters, represented by the transformation , needs to be estimated along with the robot trajectory for reliable state estimation.
different mechanisms. The spatial transformation composes with the robot pose, whereas evaluating a measurement at a temporally shifted instant requires evaluating the trajectory away from the discrete state times, typically through motion compensation or interpolation between neighboring time instants [4]. Continuous-time approaches instead construct interpolants such as B-splines [5], [6] or Gaussian processes [7], and evaluate the measurement model at the shifted time. The widely used Kalibr toolbox [2] follows this continuous-time trajectory approach for camera–IMU calibration. These methods provide the temporal structure required for calibration by introducing an explicit continuous-time representation. However, this introduces additional representation choices, such as spline knot spacing and basis order, or GP kernel structure and hyperparameters.
In spline-based formulations, a measurement may additionally depend on several neighboring trajectory control states
This work was supported in part by the Natural Sciences and Engineering Research Council of Canada (NSERC).
AG, JK, and TDB are with the University of Toronto Robotics Institute, University of Toronto, Toronto, Ontario, Canada. Corresponding author: abhishek.goudar@robotics.utias.utoronto.ca through the support of the interpolant. Spatial and temporal calibration parameters are consequently handled through different mathematical mechanisms: the spatial parameters through Lie-group composition, and the temporal parameter through interpolation of the trajectory.
In this work, we take a different approach and adopt a state representation in which time is incorporated directly into the underlying geometry. We represent the robot state using the special Galilean group SGal(3) [8], [9], whose elements comprise rotation, inertial velocity, spatial translation, and time translation. Recent work has begun exploring the temporal component of SGal(3) for state estimation with unknown measurement delays [10], [11].
We exploit the Galilean group structure to represent sensor extrinsic parameters as elements of the Aristotelian subgroup Arist(3) , obtained by restricting the Galilean velocity-boost component to zero. A key consequence is that the unknown spatial and temporal extrinsic parameters can be represented, composed, and perturbed within the same group-theoretic mechanism.
We develop motion priors driven by either body-referenced twist measurements or IMU measurements using the interoceptive sensor clock for trajectory parameterization. When this clock is ideal, the temporal component of the state evolves deterministically. On the contrary, when an external clock is chosen as the reference, uncertainty in the mapping between interoceptive sensor time and reference time is part of the state uncertainty. This allows the same framework to address both conventional spatiotemporal extrinsic calibration and estimation with a non-ideal interoceptive clock.
We evaluate the framework in simulation, on datasets, and in real MAV experiments. The experiments consider both joint spatial–temporal extrinsic calibration under an ideal interoceptive clock and trajectory estimation under a drifting interoceptive clock. Comparisons are made against Kalibr and motion-correlation-based temporal calibration where applicable. The contributions of this paper are as follows:
• We formulate joint trajectory estimation and spatiotemporal sensor calibration using SGal(3) for the robot trajectory and Arist(3) for sensor extrinsic parameters. This places spatial and temporal calibration within a common group action and perturbation framework.
• We develop motion priors for both twist- and IMU-based systems with support for ideal and non-ideal clock models. The twist formulation extends the Galilean framework to systems driven by body-referenced twist measurements.
• We validate our framework in simulation and in real experiments across multiple sensor configurations, combining IMU- and twist-driven motion priors with camera, position, and range measurements.
Calibration of unknown spatial and temporal offsets between sensors has been studied extensively before [1], [2], [27]. Approaches ranging from filtering-based methods [1], [28], [3] to batch approaches [29] have been proposed. Another popular approach to calibration uses 3D motion correlation analysis [30]; however, this approach requires all the involved sensors to produce rotational-motion information, which is not always possible. A popular and effective approach to calibration is the use of continuous-time estimation methods such as B-Splines [2], [5], [31], [6]. Alternatively, Gaussian processes have been used for spatiotemporal calibration involving moving targets [7]. While continuous-time approaches are effective, they introduce an explicit trajectory representation and design choices, such as spline order and knot spacing or GP hyperparameters. In contrast, our formulation incorporates temporal calibration directly into the group-centric state representation and does not require a separately fitted continuous-time trajectory or interpolation model.
The term Aristotelian group is less common in the robotics literature. We follow the terminology of [12], who discuss Aristotelian Lie algebras.
III. PRELIMINARIES AND NOTATION
IV. STATE REPRESENTATION
We use bold lowercase letters to denote vectors, e.g., , and bold uppercase letters for matrices, e.g., . Scalar quantities are represented using italic lowercase and uppercase letters, e.g., . The symbol 0 is used to represent a zero vector or a zero matrix, with dimensions inferred from context. Subscripts are used to denote either a time index, a sensor-specific variable, or a combination of both, depending on the context. We represent quaternions using scalar-first order .
Rotations are represented using elements of the special orthogonal group: , where is the matrix determinant. Poses are represented using elements of the special Euclidean group: , where denotes the semidirect product. The group of extended poses is denoted by , where an element consists of an orientation, a position, and inertial velocity. The Lie algebra corresponding to a group is denoted using lowercase Fraktur letters, e.g., the Lie algebra of is .
The special Galilean group [8], [32] consists of spatial rotations, spatial translations, inertial velocities (or boosts), and time. Elements of the Galilean group and its Lie algebra , are represented as
where and represent the orientation, inertial velocity, and translation of the robot, and is the time. An interpretation for the different components of is provided in the following section. The Lie algebra components , and are the Lie algebra coordinates of rotation, inertial velocity, position, and time, respectively. The operator maps a vector to the corresponding Lie algebra element, and the inverse operator is denoted by . We also use the tuples and to refer to elements of and , respectively. We choose an ordering of the Lie algebra coordinates similar to that in [8], as this yields an upper-triangular matrix structure for the adjoint representations, a structure that will be exploited later. The exponential map is given by
where (the left Jacobian of ) and belong to the family of -functions [33]:
Closed-form expressions for and can be found in [34]. The procedure for computing the corresponding logarithm can be found in [8], [15].
In this section, we motivate the representations for the state and extrinsic parameters used in this work. We represent the robot's trajectory with elements of the Galilean group, . The rotation , translation , and velocity components represent the spatial coordinates and velocities, respectively, of a robot-fixed frame, , with respect to a chosen inertial reference frame . Analogously, the time component represents the temporal translation with respect to a chosen reference clock. The boost component represents the inertial velocity with respect to reference time, .
One objective of this work is to calibrate inter-sensor extrinsic parameters. We represent the spatial and temporal offsets between sensors using elements of the Aristotelian group [12]: , where denotes the direct product. An element and a corresponding Lie algebra are represented by the following matrices
where and represent the rotational and translational offsets between the frame of sensor and a chosen reference frame, while represents the temporal offset relative to a chosen reference clock. As before, we also use the tuple to represent an element of . The motivation for using this lifted representation of the inter-sensor extrinsic parameters is as follows.
As an abstract Lie group, is isomorphic to the direct product : . The benefit of such a representation is not in the parameterization, but its action when viewed as an element of a subgroup of . In the conventional formulation, the two factors of enter the estimation problem through unrelated mechanisms: the rigid transform composes with poses, while the time offset is used in the continuous-time trajectory representation, such as B-splines [2], [31] or Gaussian processes (GP) [35], [15], where the sole purpose is to render the trajectory differentiable in time. In our formulation, is not a direct-product factor but a subgroup element of . Importantly, the Galilean group is a semidirect product group: and not isomorphic to . This semidirect product structure couples time translations to inertial velocities or boosts. Consequently, when acts on a trajectory state by right action, , the boost component of the state couples with the time offset of the sensor extrinsic parameters to produce the temporal transport intrinsically. The velocity-temporal offset correction that discrete-time methods append as an explicit model term, and that continuous-time methods obtain by differentiating a fitted spline, for example, is here a consequence of the group operation itself. The isomorphism holds at the level of the calibration parameters but not when included as a part of the estimation problem. Note that the temporal offset component is coupled only with inertial velocity – the rotational component is unaffected. This coupling stems from the assumptions underlying Galilean spacetime.
Another benefit of a group-based approach is apparent from optimization-based sensor fusion, where Jacobians of system process and measurement models with respect to state and sensor extrinsic parameters are needed. With a group-centric approach to state and extrinsic representation, the dependence of Jacobian blocks on the sensor extrinsic parameters is captured through the SGal(3) adjoint rather than through the derivative of a fitted interpolant. Temporal calibration thus inherits, without special consideration, the linearization-point management and sparsity of the state variables.
V. SYSTEM MODEL
We adopt the common approach to trajectory estimation where an interoceptive sensor, such as a wheel-odometry sensor or an IMU, is used to generate a motion prior, while exteroceptive sensors, such as range sensors or cameras, provide corrective measurements.
To combine information from multiple sensors coherently, we need a source of reference time. A common approach is to use the clock of one of the sensors as the reference clock, against which other sensor clocks are compared. Next, we present two clock models considered in this work.
A. Clock model
We begin by noting that the temporal coordinate t in (1) is defined with respect to a reference clock. If the interoceptive sensor clock is reliable and does not exhibit non-ideal behaviour such as drift or rate instability, it can be chosen as the source of reference time. In this case, the temporal coordinate t of G can be determined directly from the interoceptive measurement timestamps.
Alternatively, if the interoceptive sensor clock is non-ideal and an exteroceptive sensor is to serve as the source of reference time, then t of G is directly observed only at exteroceptive measurement times and must be inferred at intermediate time steps.
- Choice of independent variable: An important consideration is the choice of the independent variable for computing integrals and derivatives. In most cases, the de facto independent variable is the temporal coordinate t; however, t may or may not be directly observable depending on the source of reference time. For instance, when the exteroceptive sensor clock provides reference time, the value of t is not known precisely between two exteroceptive measurements. We therefore do not use t as the independent variable.
In this work, we use the interoceptive clock time, denoted by , as the independent variable and write . The sensor time need not be an accurate measure of reference time to serve as the independent variable; it need only provide a known, smooth, monotonic parameterization of the trajectory. When the interoceptive clock is used as the reference, the interoceptive sensor time and the reference time coincide up to a constant; otherwise, they are related through the chosen clock model. Importantly, in the latter case, in (1) is not merely the current time, but the state variable that maps the chosen trajectory parameter into the reference time: . With this convention, we consider the following models for interoceptive sensor clocks.
- Ideal clock: In this case, reference time and interoceptive sensor time advance at the same rate:
Hence,
- Non-ideal clock: An exteroceptive sensor serves as the source of reference time. The mapping from the interoceptive sensor time s to reference time t is uncertain. We model the relative clock rate as having an additive white noise component:
The driving white noise has power spectral density , where denotes the expectation operator, and is the Dirac-delta function. This model causes the sensor clock error to undergo a stochastic drift whose variance grows linearly with elapsed sensor time at a rate determined by . Since the interoceptive clock is non-ideal, the value of in (1) is not directly known from the interoceptive timestamps and must be estimated using measurements referenced with respect to the reference clock.
Although physical time is monotonic, the non-ideal clock model does not explicitly enforce this constraint. In practice, the model is implemented using discrete-time increments,
The probability of a negative time increment is negligible for the values of considered in this work. Thus, the continuous-time white-noise formulation in (5) is an idealized representation, not a physical description of the clock. The parameter is chosen such that the accumulated uncertainty accommodates the expected clock drift over the estimation window T.
- Effect of a non-ideal clock on rate-driven kinematics: In this section, we highlight a non-ideal clock's effect on the system kinematics. We assume that a rate sensor, such as a gyroscope, reports the true physical rotation rate, even when its clock experiences drift. The effect of the clock drift is on the reported interval between the rate measurements, and not on the reported rates. Consider a true angular displacement that occurs while reference time advances by and the interoceptive clock advances by , with under the non-ideal clock model. The true angular rate is , so the angular displacement over an interoceptive interval is . The true attitude kinematics are . The attitude kinematics expressed with respect to interoceptive time are
The non-ideal clock therefore changes the amount of reference time and therefore the true angular displacement, associated with an interval of sensor time. For the ideal clock, and we recover the true kinematics.
Remark 1. The above model assumes a rate output IMU. If the IMU instead outputs angular increments over its interval , . In this case, the measurement already includes the clock factor, , and the clock noise would enter through the temporal component alone (5).
B. Twist-driven motion model
In this section, we develop a motion prior with a twist sensor as the interoceptive sensor. A common example of such a sensing modality is wheel odometry that provides body-referenced twist. The measured angular rate and linear velocity are modeled as
where and are the true angular rate and linear velocity, respectively. As highlighted in the previous section, the twist measurements are true physical quantities, and with ; however, they are indexed by the sensor time . The noise terms are modeled as zero-mean white noise processes with power spectral density matrices and . We incorporate the two components of a twist measurement (6) in different ways. The angular rate is the input that drives the rotational kinematics, whereas the linear velocity is treated as a measurement,
This is different from a formulation in which is also used as an input to the motion prior. There has been some attention on using sensor data as control inputs or as measurements [36]. We motivate our hybrid approach next.
We use the following kinematic motion model to generate our motion prior
where the dependency on time has been omitted for clarity. Here, is the inertial velocity with respect to reference time, so that the s-parameterized position kinematics are .
The velocity kinematics require further consideration. A twist sensor reports body-centric velocity , while the state (1) represents velocity in the inertial frame . One may therefore be tempted to impose the constraint and differentiate it, which together with yields , in which the first term is a transport term arising from the rotation of a constant body-frame velocity. We implemented this model and evaluated it extensively; however, we found it to be inadequate. Specifically, the transport term depends on only through the cross product , so the measured velocity does not drive the motion model under pure translational motions ( ), which can be limiting. Instead, we leave the velocity kinematics driven purely by a white-noise-on-acceleration prior [35] and incorporate the information carried by through the measurement model (7). Here is expressed in the body frame with , and a diagonal models independent acceleration variations along the body axes. We emphasize that represents unmodeled acceleration rather than sensor noise and, as such, must be computed from the acceleration content of the trajectory. Note that is an artificial process model defined directly with respect to the trajectory parameter . Consequently, the velocity kinematics in (8) are not scaled by the clock factor.
The motion model (8) can be expressed in the following group-affine form [19]
where consists of exogenous inputs and noise terms:
The subscript denotes quantities specific to the twist sensor. Following [18], [15], we decompose the model (8) into nominal and error models. The nominal model propagates the nominal state , while the error model propagates the associated uncertainty using the error state . The nominal and the error states are related to the true state as . The nominal model associated with (9) can be expressed as (see Appendix A)
where
The associated error model is given by (see Appendix A)
where , is the adjoint representation of the Lie algebra [8], and
Importantly, the error dynamics do not depend on the state, which is a consequence of the group-affine structure of the motion model. The error model (11) can also be expressed in matrix form as a linear time-varying (LTV) system:
where , and
Products of with other noise terms or with error-state perturbations are second order and are neglected throughout.
Remark 2. The zero last column of shows that the temporal perturbation does not directly influence the error-state dynamics. The clock-rate uncertainty, through the last column of , influences the rotation and the temporal components of the error state. The position component is affected by the boost-time coupling: accumulated clock uncertainty induces position uncertainty. Any measurement that constrains the position, therefore influences estimation of the temporal error.
To derive the discrete-time kinematics for the nominal model, we assume that the angular rate is piecewise constant over , where denotes the timestamp as reported by the twist sensor's clock. The discrete-time propagation equation for the nominal model (10) can be expressed as
where is the transition matrix given by
with . The subscripts and denote evaluation at and quantities associated with the twist sensor, respectively; denotes both. Expanding the group product in (13) gives , , and . Note that the velocity is propagated into position by the group operation rather than by the transition matrix, so the constant-velocity translational model is obtained without introducing it explicitly.
To calculate the state covariance associated with (13), we use the continuous-time approach of [15, Section 3.4]. In this framework, the error-state trajectory is modeled as a zero-mean Gaussian process (GP): , with covariance function . This GP is driven by white noise with power-spectral-density matrix , where denotes a block-diagonal matrix whose diagonal blocks are given by its arguments. Note that no longer appears here; it weights the measurement factor (7) instead. Under the piecewise-constant input assumption, the covariance propagation between consecutive times and can be expressed as
where . The integral in (14) can be evaluated exactly using the method of [37]; however, this can be computationally expensive. We use the following third-order approximation in :
Although is rank deficient, the coupling from into in generates the position block over the interval, so is full rank for without any additional regularization of the acceleration block. The discrete-time propagation equations presented thus far were derived using the non-ideal clock model (5). In the next section, we discuss their specialization to the ideal clock model (4).
Error model with ideal clock: We begin by noting that the ideal clock model (4) can be decomposed as
which is similar to the previous case with . The nominal model is identical to the previous case, and the nominal state propagation equation (13) applies to this case as well. The error model requires further consideration. Note that, since , the noise density matrix becomes , which is not positive definite
Since , time evolves deterministically. One approach to incorporate such deterministic dynamics into an estimator is to impose them as equality constraints, resulting in a constrained optimization problem. Alternatively, the constrained problem can be approximated as an unconstrained problem by treating the deterministic dynamics as soft constraints with high confidence [38]. For the ideal-clock model, this would amount to assigning a small artificial variance, , to the temporal component of , thereby rendering positive definite. Although this approximation approaches the deterministic-clock model as , the corresponding information weight grows as . Consequently, a very small can lead to a poorly conditioned optimization problem [38].
We propose an alternative approach in which we retain the nominal state on , while the error state is restricted to the Lie algebra of :
where . The algebra is naturally embedded in by setting ; this subset is closed under the Lie bracket and therefore forms a Lie subalgebra. Covariance propagation is then confined to this subalgebra, with , free from the rank deficiency introduced by the ideal clock model. The advantages of this approach are (i) no artificial uncertainty is introduced, (ii) the error state contains only uncertain components with minimal degrees of freedom, and (iii) the conditioning of is not artificially degraded by an arbitrarily small temporal variance. The covariance matrix can be calculated as in (15), using the reduced noise density matrix . Such an approach is also adopted in [25], where the covariance block associated with time is dropped post-hoc for evaluation. In our case, this falls out naturally from the reduced uncertainty parameterization.
Remark 3. Excluding the error component from the error model does not diminish the benefits of our proposed group-theoretic approach to calibration, as the nominal time component is still retained, and its coupling with the boost component is preserved under composition with other group elements.
The reduced tangent-space representation requires two corresponding modifications. First, the error state matrix and the noise input matrix must be adapted to the reduced error state. Local solvers used for trajectory estimation, such as Levenberg-Marquardt, require Jacobians of the motion and measurement models with respect to the error state. The second modification involves adapting these Jacobians to the reduced tangent space. One approach is to derive the necessary reduced Jacobians manually. Alternatively, we propose general-purpose reduced-tangent-space operators that map between a subalgebra and its ambient space, allowing these modifications to be performed systematically (see Appendix C).
C. IMU-driven motion model
In this section, we develop a motion prior with an IMU as the interoceptive sensor. An IMU measures body-referenced angular rate and specific force . These measurements are related to the true angular rate and inertial-frame acceleration a as
where denotes the gravity vector expressed in the inertial frame. As in the twist case, the measured quantities are true physical quantities with respect to reference time, and , while the samples are indexed with interoceptive clock time . The measurements are corrupted by additive biases and white noise processes with power spectral density matrices and . The biases are modeled as random walks:
driven by zero-mean white noise processes with spectral densities and .
The motion model adopted here is similar to those in [39], augmented with the non-ideal clock model. The continuous-time kinematics for the core state have the form
As in the previous section, all derivatives are taken with respect to the interoceptive sensor time , which in this case is the time reported by the IMU clock. The state in this case also includes the IMU biases: . The IMU bias random walks are defined with respect to the interoceptive clock , as such they are not scaled by the clock factor . The motion model (19) can be expressed as the following system
where
with , and . The subscript denotes quantities specific to the IMU-driven model.
Remark 4. Under the non-ideal clock model, depends explicitly on t and hence is linear time-varying even under a piecewise-constant input assumption. This costs little, however, since is nilpotent and its matrix-exponential series terminates after the quadratic term.
As in the previous section, the motion model (20) is decomposed into nominal and error models to propagate the nominal state and covariance, respectively. The nominal model for (19) can be expressed as (see Appendix B)
where
with , and . The corresponding error model has the form (see Appendix B)
where
with , , and . The operators ad and Ad denote the Lie algebra adjoint and Lie group adjoint representations, respectively. The error model (22) can alternatively be expressed in matrix form as
where , , and
with .
Remark 5. The block of the Jacobian shows that the temporal error couples into the position-error dynamics in the presence of acceleration .
To derive the discrete-time model corresponding to (21), we make the following three assumptions: (i) the IMU measurements are piecewise constant over , (ii) the IMU biases are constant between two time steps, and (iii) between and so that Under these assumptions, the discrete-time state propagation equation has the form (see Appendix B)
(24) where is given by
with . To propagate the associated uncertainty, we use the same approach outlined in the previous section. In this case, the GP is defined over the augmented error state, including the bias errors: , with . The continuous-time noise power spectral density matrix is . As in (15), we use a third-order approximation to compute the discrete-time process-noise covariance as
with and evaluated at and held constant over the interval .
a) Error model with ideal clock: The procedure for incorporating the ideal clock model is identical to the twist-driven case outlined in Section V-B. The nominal model evolves on , while the error state evolves on . The reduced error state in this case is , with continuous-time noise density matrix . The same reduced-tangent-space operators apply to the IMU case, since the reduction acts only on the component of the state.
VI. MEASUREMENT MODEL
In this section, we present models for exteroceptive sensors. We use the subscript to denote quantities specific to an exteroceptive sensor e.
A. Asynchronous measurements
We briefly discuss the incorporation of asynchronous measurements. Most sensors generate data at different rates, and in the absence of an external trigger or synchronization scheme, an asynchronous sampling offset may exist between the measurements. For example, let denote the interoceptive measurement time, and let denote the exteroceptive measurement time expressed with respect to the reference clock. The reference time corresponding to is , part of the state . The asynchronous sampling offset is therefore defined in the reference-time domain as
where we drop the subscripts and write when the context is clear. For the ideal-clock model, , and reduces to the ordinary timestamp difference , which is directly observable from the measurement timestamps. With a non-ideal-clock model, is an estimated state, so that accounts for the accumulated clock drift through .
To handle asynchronous sampling offsets, we consider the one-parameter subgroup of time translations [24], where has the form
Composition with translates time by and, through the Galilean group law, translates position by . Importantly, this translation is consistent because is defined with respect to reference time and is a reference-time interval. Let be the state at time , the state at time can be expressed as
Remark 6. The rotational component remains constant over , as the time-translation group does not encode any rotational increment. Such a constant-velocity, constant-orientation propagation may be inadequate under significant rotational motion.
Remark 7. In contrast to the sampling offset , the temporal offset in may be unknown and must be estimated. The elapsed time between two measurements must account for the sampling offset and the (unknown) temporal offset: .
Remark 8. The non-ideal clock motion priors developed previously constrain only increments of the temporal state t. A constant temporal offset and accumulated clock drift influence the temporal state as increments: they are not jointly identifiable unless one is constrained. As such, we estimate clock drift and extrinsic temporal offset separately.
B. Measurements as events
In Galilean spacetime, a measurement can be viewed as an event [8] formed by pairing the raw sensor reading with the reported timestamp: , where is the timestamp of measurement from sensor expressed with respect to the chosen reference clock.
Remark 9. With a non-zero (unknown) temporal offset , the time of the physical measurement event is .
Many commonly used measurement models can be expressed through the action of the Galilean group on the space of events. Importantly, the event coordinates are expressed in the source (or reference) frame of the corresponding group transformation. We consider two cases here: events expressed with respect to the sensor or body frame, and events expressed with respect to the inertial frame. Let be the robot state associated with measurement and let be the extrinsics transformation of sensor e. A measurement model in which the event is expressed in the sensor frame can be written as
where is the event expressed with respect to the sensor's frame. The event represents the sensor origin of a generic exteroceptive sensor at its local time origin, and the robot state and extrinsic transformations introduce the necessary spatial and temporal offsets to transform into the necessary reference frame and reference time. For a linear measurement model, we have , in which case (26) becomes . For an event in the inertial frame
where denotes an event composed of the position of landmark and the times reported by sensor e's clock. Sensor noise has been omitted from the measurement models for clarity. Note that represents the inertial frame with respect to the robot frame.
C. Measurement models
We present a generic measurement model in this section and specialize it to different sensing modalities in subsequent sections. Let be the state associated with the interoceptive sensor's measurement timestamp :
where is additive Gaussian noise of covariance . In (27), the event is used only for illustration; the event representation may vary depending on the measurement model. The dimension of the noise depends on the context. In the following sections, we omit for clarity, noting that and its inclusion is compatible with all subsequent measurement models.
- Position measurement model: The observation in this case is the sensor position in the inertial frame :
where is a measurement of the sensor position corrupted by , and
Note that for a position sensor, the spatial extrinsics consist only of the position offset. The matrix is a projection matrix that extracts the position component, where is the identity matrix.
Remark 10. If the position sensor is chosen as the clock reference, we set by convention.
- Range measurement model: In range-based positioning, a robot equipped with a range sensor, referred to as a tag, estimates its position by measuring distances to other static range sensors installed in the environment, referred to as anchors. The measured distance to anchor l at measurement j is

Fig. 2. Schematic of the IMU-camera extrinsic calibration setup. The Aristotelian element represents the spatial and temporal transformation from the camera frame to the IMU frame . A feature point on the calibration target is observed by the camera, while and denote the target and inertial frames, respectively.
where is the norm, is the position of anchor , is the position of the tag at time , and is the measurement noise. As before, inter-sensor extrinsics consist of the position of the tag in the body frame and the time offset . Range-based positioning is challenging because range measurements are typically sparse and noisy. The identifiability of the inter-sensor extrinsics requires at least three non-collinear anchors and accelerated motion along translational and rotational axes [3].
- Camera measurement model: In camera-based localization, the pose of the camera is estimated by observing landmarks in the environment. We assume that the positions of the landmarks are known in a local reference frame , which could be different from the inertial frame . A common approach for calibration is to use a bespoke pattern or calibration board as landmarks, in which case a coordinate frame fixed to the board is used as the reference frame. For clarity of exposition, we assume .
We augment a landmark's position with the time at which it is observed: . This observation can be transformed into the camera's reference frame as
where is the position vector of the landmark in the camera's reference frame. The extrinsic matrix encodes the relevant spatial and temporal offsets. The measured pixel coordinates are related to the landmark observation as
where , extracts the top two coordinates of a homogeneous image point, and . The matrix is the camera intrinsic matrix
where are the focal-length parameters along the horizontal and vertical image axes, respectively, and denote the principal point coordinates. We assume that the intrinsic matrix is known from a prior intrinsic calibration procedure. Additionally, we assume that the pixel coordinates have been undistorted to account for any lens distortion.

Fig. 3. Factor graph for batch trajectory estimation and calibration. The robot state, , and the inter-sensor extrinsics, , are nodes representing the states to be estimated. We consider two types of factors: a motion prior generated using an interoceptive sensor, represented by solid black circles, and exteroceptive measurement factors, represented by solid blue circles.
VII. BATCH TRAJECTORY ESTIMATION
In this section, we use the motion and measurement models developed in the previous section to formulate an optimization problem that estimates the robot trajectory and the inter-sensor extrinsic parameter. We use the symbol to denote the state at time , and to denote the extrinsic parameters. Depending on the interoceptive sensor, may include other elements such as IMU biases, in addition to the robot state . The full state vector over time steps is . Let be the vector of measurements and is the vector of interoceptive sensor measurements input to the motion prior. We use a maximum a posteriori (MAP) approach to estimate the robot trajectory and extrinsic parameters. We assume that (i) the motion model obeys the Markov property, and (ii) the different sources of Gaussian noise are uncorrelated over time and with each other. The factor graph corresponding to this setup is shown in Figure 3. Under these assumptions, the MAP objective can be expressed as the optimization problem
where is the manifold of the state. Note that for a twist-based interoceptive sensor . A more complete formulation of the MAP problem can be found in [15, Section 3.1]. The cost incorporates any prior information on the initial state and any calibrated parameters for which prior estimates are available. The cost terms and correspond to the motion prior and exteroceptive measurements, respectively. The individual cost terms are given by
The term is the residual between the propagated and estimated states, and is the associated covariance. For example, with an IMU-based motion prior, the error term based on (24) is
The associated uncertainty is given by (25). Similarly, the residual term for a measurement based on (27) is
For example, the measurement residual for the position measurement model (28) is .
A. Implementation details
Our implementation focuses primarily on simultaneous trajectory estimation and extrinsic calibration. In this setup, the interoceptive sensor is chosen as the reference sensor, and the spatial and temporal extrinsic parameters of an exteroceptive sensor are jointly estimated with the robot trajectory. We also evaluate our proposed method for trajectory estimation with a non-ideal clock. In this case, the exteroceptive sensor extrinsics are assumed known and the interoceptive sensor's clock is modeled as drifting over time (representing a non-ideal clock), and this drift is estimated jointly with the robot trajectory.
We assume the following quantities are known: (i) sensor noise covariances, (ii) the camera intrinsic and lens distortion parameters, and (iii) the calibration pattern geometry. We use the Ceres Solver [40] as our back-end optimizer. To perform optimization on SGal(3) and Arist(3) manifolds, we extended the Sophus library [41] by implementing the necessary data structures for SGal(3) and Arist(3) . Note that the sensor extrinsic parameters for range and position sensors belong to a subgroup of Arist(3) in which the rotation component is fixed to the identity. Similarly, it may be the case that the temporal offset is known and only the spatial offset needs to be estimated. Instead of defining a new manifold for each subgroup, we implemented a Submanifold class in which selected group components can be held constant. The Ceres Solver supports subset manifolds for vector spaces (as SubsetManifold), and we extended this concept to nonlinear manifolds . We use the Ceres Solver's built-in automatic differentiation to compute all required Jacobians.
Remark 11. Our extension to the SubsetManifold approach can be applied to selected group components such as orientation, position, inertial velocity, or time, rather than to individual matrix or parameter-vector entries.
To solve the MAP problem (31), we use the Levenberg–Marquardt (LM) solver. The solver is configured to use a sparse Cholesky solver (SPARSE_NORMAL_CHOLESKY) with non-monotonic steps. The LM solver is run until convergence or a maximum of 200 iterations is reached.
As the LM solver is iterative, it requires a reasonable initial guess to perform well. We found that initializing the robot trajectory through dead reckoning using only interoceptive measurements provides a poor initial guess. Our initialization procedure is as follows. For range and position sensors, the robot states and the extrinsic parameters are initialized to their respective group identities. For camera sensors, the pose component of the robot state is initialized by composing an
Code will be made available after publication.
ground truth estimated

Fig. 4. Ground-truth and estimated trajectories from simulation with a non-ideal IMU clock. Corrective measurements are provided by a position sensor, which also serves as the reference clock.
initial estimate of the spatial extrinsic parameters with the pose estimated using the Perspective-n-Point (PnP) algorithm; the velocity component is computed numerically by differencing the position components. The states between neighboring discrete measurement times are initialized using the motion model. In all cases, the state times are initialized with the interoceptive measurement timestamps.
VIII. VALIDATION
In this section, we evaluate our methods using simulations, real-world datasets, and experiments. We use position and rotation root-mean-square errors (RMSEs) as metrics to quantify the estimation accuracy:
where denotes the estimated value of x. The calibration accuracy is evaluated using the following errors
Where ground truth is unavailable, we use the reprojection error to evaluate the consistency of the estimate with camera-based measurements. For landmark l observed at time , the reprojection error corresponding to (30) is
where . The mean reprojection error is the average value over all landmark observations in the trajectory.
A. Simulation
- Trajectory estimation with non-ideal clock: In this section, we estimate the trajectory when the interoceptive sensor
clock is non-ideal. We generate a synthetic dataset in which the true IMU timestamps are corrupted to simulate a clock that drifts over time. A position sensor provides corrective measurements and defines the reference time. We assume that the sensors are rigidly connected with known sensor extrinsic parameters and zero temporal offset. The dataset generation procedure is as follows.
The trajectory is generated as per-axis sum of sinusoids with distinct frequencies for position and orientation. This allows us to calculate velocity, acceleration, and angular velocity in closed form. The trajectory spans a m workspace and is 180 s long (see Figure 4). The peak body angular rate is and the peak acceleration is . The IMU samples uniformly at 100 Hz in its own clock s, the corresponding reference times follow from the non-ideal-clock model (5) as described below, and the true angular rate and acceleration are evaluated at the reference times . The clock error is modeled as a Wiener process. We numerically integrate the stochastic differential equation (5) using the Euler–Maruyama [42, Section 8.2] scheme:
where . With s the clock error reaches a peak of 50ms over a duration of 180s. The IMU noise parameters are chosen to reflect real sensor characteristics: , , , and , where denotes a noise density and the corresponding power spectral density matrices are , , , and . We report densities rather than their squares, as these are the values typically quoted in sensor datasheets. Biases are drawn randomly at initialization and evolve as random walks. The position sensor clock is drift-free, and its measurements are sampled uniformly in reference time at 20 Hz with . The lever arm from the IMU origin to the position sensor is . This simulation is a timestamp-corruption experiment: the physical IMU quantities are evaluated at the reference times and indexed by the sensor timestamps .
We then apply our batch estimation approach using each of the two clock models: the ideal-clock model (4) and the non-ideal-clock (5) model. Since the simulated IMU clock is non-ideal, this simulation evaluates the benefit of explicitly modeling clock uncertainty relative to the ideal-clock assumption. Trajectory estimation results and estimated clock error from ten randomized simulations are shown in Figure 5. The estimated trajectory from one such simulation is shown in Figure 4. The true IMU clock error relative to the reference clock is given by , where t denotes reference time and s denotes IMU clock time. Under the ideal-clock model, we have and therefore cannot account for the accumulated clock drift. With the non-ideal-clock model, reference time is estimated as part of the state, and the corresponding reference-time estimation error is . The estimated reference time can also be used to recover the IMU clock error as , which can be compared directly with the true clock error . Qualitative results from one simulation with non-ideal-

Fig. 5. Trajectory estimation error and residual clock error from simulations with a drifting IMU clock. Since the IMU clock drifts over time, using the non-ideal-clock model results in lower position and clock errors than using the ideal-clock model.

Fig. 6. (Top) Clock-error estimation results from simulation showing the estimated (Est.) clock error alongside the true clock error . (Bottom) Residual clock error in the estimated reference time .
clock model are shown in Figure 6. As noted in Section V-C, both temporal uncertainty and IMU bias errors influence the propagated translation state, creating potential for coupling between their estimates. As shown in Figure 7, the IMU biases are estimated reliably under the non-ideal-clock model.
- Sensor extrinsic calibration with Twist-based motion prior: In this section, we perform trajectory estimation and sensor extrinsic calibration with a twist sensor as the interoceptive sensor, and one of camera, position, or range sensors as the exteroceptive sensor.
The trajectory generation procedure is similar to the previous section. In this case, each sequence is 30s long, with sufficient excitation for all three translational and rotational axes to promote observability of the extrinsic parameters.
The twist sensor is sampled at 100 Hz. The white-noise-on-acceleration density of the motion prior is computed from the generated trajectory. We consider two exteroceptive sensors
TABLE I SENSOR-NOISE REGIMES FOR TWIST-BASED CALIBRATION.
| Sensor | unit | Sensor noise (1σ) | ||
|---|---|---|---|---|
| low | medium | high | ||
| Twist (ω) | rad/s/√Hz | 2.5e-4 | 2.5e-3 | 0.025 |
| Twist (v) | m/s/√Hz | 1.25e-4 | 1.25e-3 | 0.0125 |
| Camera | px | 5e-3 | 5e-2 | 0.5 |
| Position | m | 1e-4 | 1e-3 | 0.01 |

Fig. 7. Estimated () and true () gyroscope (top) and accelerometer (bottom) biases from simulation with non-ideal IMU clock.

Fig. 8. Simulated trajectory for calibration of the extrinsic parameters between a twist sensor and a camera sensor. Landmark color indicates the number of observations across multiple frames during calibration.
in this setup: a camera sensor and a position sensor. The camera is a distortion-free pinhole model that generates images at 20 Hz with intrinsics , , , and a resolution of . For the camera-based simulations, we use a cloud of 200 point landmarks distributed uniformly in a m volume (see Figure 8). To simulate reduced feature availability due to effects such as occlusion and motion blur, we randomly mask landmarks; the average number of landmark observations is 19.7 per frame. The camera is forward-looking, with rotation offset given by the quaternion , and translation offset m with respect to the twist sensor. The position sensor provides absolute world-frame fixes at 30 Hz and has a spatial offset of m.
It is well known that observability of sensor extrinsics requires sufficiently excited motion [1], [43]. As sensor noise increases, the motion-induced signal becomes more difficult to distinguish from measurement noise, reducing practical identifiability of the extrinsic parameters. Stronger excitation can therefore improve calibration accuracy in high-noise regimes. To quantify this effect, we evaluate the estimation performance across three sensor categories with different noise

Fig. 9. Trajectory estimation results from simulations involving a twist sensor paired with (i) a position sensor (top) and (ii) a camera (bottom), for different inter-sensor temporal offsets. Results are shown for three sensor-noise regimes, ranging from low noise to high noise. Values are from trials for each temporal offset value and noise regime.
characteristics. The sensor noise parameters for the different categories are provided in Table I.
We performed Monte Carlo simulations where the exteroceptive sensor extrinsic parameters were perturbed from their true values, and the batch estimator was used to estimate the entire trajectory and the sensor extrinsic parameters. Trajectory estimation results for the three noise regimes are shown in Figure 9. Results for the inter-sensor temporal offset calibration are shown in Figure 10, where the results from the high sensor noise regime are presented separately. The inter-sensor spatial extrinsic calibration results are shown in Table II. In the high-noise regime, the calibration accuracy deteriorates substantially. This behaviour is consistent with the reduced signal-to-noise ratio of the motion-induced calibration signal. To verify this, we increased the length of the lever arm to m and the magnitude of the translational
TABLE II
SPATIAL EXTRINSIC CALIBRATION ERRORS FROM SIMULATION WITH TWIST-BASED MOTION MODEL FOR DIFFERENT SENSOR-NOISE REGIMES, AVERAGED OVER ALL TEMPORAL OFFSETS AND MONTE CARLO TRIALS ( TRIALS PER SENSOR). VALUES REPORT MEAN ONE STANDARD DEVIATION OF THE ERROR NORM.
| Sensor | Noise | [cm] | [deg] |
|---|---|---|---|
| Position | low | — | |
| medium | — | ||
| high | — | ||
| Camera | low | ||
| medium | |||
| high |

Fig. 10. Temporal offset estimation results from simulations under different sensor-noise regimes for a position sensor (top) and a camera (bottom). Errors are computed as the difference between the true value and the estimated value from trials for each temporal offset value. Results for the high-noise regime are shown on the right.

Fig. 11. Results from simulations ( trials) for temporal offset estimation with a position sensor in the high-noise regime. The magnitude of the twist inputs to the motion model is increased to improve the estimation accuracy under higher sensor noise.
velocity input from to . The temporal offset estimation results involving a position sensor for this setup are shown in Figure 11. The increased excitation improves the temporal-offset estimation accuracy. We observe a similar improvement in spatial-offset estimation, with an error of cm, averaged across all temporal-offset values and trials.
- Sensor extrinsic calibration with IMU-based motion prior: In this section, we evaluate our approach with an IMU as the interoceptive sensor, and one of camera, position, or range sensors as the exteroceptive sensor. Many of the simulation parameters are similar to those in the previous section, with extensions to support an IMU.
The IMU is sampled at 100 Hz. IMU biases are initialized randomly and evolve as a random walk. The IMU noise parameters are based on the EuRoC dataset [44]: rad/s/, m/s/, rad/s/, and m/s/, with as before. Unlike in the previous section, we include a calibration target, where the target is a inner-corner checkerboard with 80 mm squares approximately 2 m in front of the trajectory. As in the previous case, to reflect reduced feature availability due to motion blur and occlusions

Fig. 12. Trajectory estimation results using an IMU paired with a camera, a position sensor, and a range sensor, for varying temporal offsets. Values are computed from trials for each temporal-offset and sensor modality.
TABLE III
SPATIAL EXTRINSIC CALIBRATION ERRORS FROM SIMULATION WITH IMU-BASED MOTION MODEL, AVERAGED OVER ALL TIME OFFSETS AND MONTE CARLO TRIALS ( PER SENSOR). VALUES ARE MEAN ONE STANDARD DEVIATION OF THE ERROR NORM.
| Sensor | εr_e [cm] | εθ_e [°] |
|---|---|---|
| Camera | 0.158 ± 0.114 | 0.0208 ± 0.0129 |
| Position | 0.376 ± 0.263 | — |
| Range | 1.101 ± 0.451 | — |
arising from dynamic movement, the number of visible corners per frame is varied; the average number of corner detections is 32.9 corners per frame. At each range measurement time, the range sensor produces one distance measurement at 40 Hz to a single anchor drawn uniformly from six anchors placed in an m volume, with 1 cm noise. The spatial offset for the range sensor is m. To simulate asynchronous sampling, the exteroceptive measurement timestamps are shifted by 4 ms relative to the IMU timestamps. Note that the sensor-noise regime is similar to the high noise case from the previous section.
As in the previous section, the spatial and temporal offsets are perturbed from their true values and estimated along with the trajectory using a batch estimation approach. RMSE results from simulations ( trials per temporal offset value for each sensor) are shown in Figure 12. Temporal-offset calibration results are shown in Figure 13, and the inter-sensor spatial extrinsic errors are provided in Table III. Compared to the twist-driven case, the IMU-based setup yields lower calibration error than the twist-driven setup under comparable exteroceptive sensor-noise regimes. The estimation error varies across the different sensing modalities with the camera yielding the lowest errors and the range sensor the highest.
B. Datasets
In this section, we validate the proposed models using real datasets and data collected from real-world experiments.
- Twist-camera temporal calibration on Starry Night dataset: We apply our twist-based motion model to the Starry Night dataset [5], using the pre-processed form distributed with [15]. In this dataset, the sensor setup, composed of a

Fig. 13. Temporal offset estimation results from simulations with IMU as the interoceptive sensor. Errors are calculated as the difference between true value and estimated value from trials for each temporal offset and sensor modality.
TABLE IV
ESTIMATION ERRORS WITH ARTIFICIAL TEMPORAL OFFSETS OF 0–20 ms INJECTED INTO THE STEREO CAMERA STREAM, REPORTED AS MEAN ONE STANDARD DEVIATION OVER THE TESTED OFFSETS.
| Position RMSE [cm] | Rotation RMSE [°] | ετ_e [ms] |
|---|---|---|
| 2.72 ± 0.08 | 2.97 ± 0.12 | 0.00 ± 0.14 |
stereo camera and an IMU, is moved over a field of 20 reflective markers of known position as shown in Figure 14. Rather than the raw inertial measurements, the distributed dataset provides body-referenced linear and angular velocity (twist) measurements, which we treat as physical velocities and rates with respect to reference time, consistent with (6). The exteroceptive measurements are obtained from a stereo camera with a known baseline. The monocular camera model presented in Section VI-C, can be extended to a stereo camera model in a straightforward manner. The dataset also includes the spatial extrinsic parameters, but no temporal offset is provided. The sensor measurements are interpolated to the motion-capture system timestamps, but the sensors are not hardware synchronized and hence there may be a non-zero temporal offset. We apply our proposed approach to estimate the trajectory and the temporal offset between the sensors, while holding the spatial offset fixed to the known value. We use sensor data between the time stamps 1400 to 1899, corresponding to the interval of maximum excitation in the dataset. The estimated trajectory from this experiment is shown in Figure 14. The estimated temporal offset was relatively small in this case: s. The resulting trajectory position and rotation RMSE values were 2.72 cm and the 2.97°, respectively.
Since the true temporal offset is unknown, we further evaluate the efficacy of our approach by adding artificial temporal offsets, in addition to the existing offset, to the stereo data stream. We vary the injected offset from 0 ms to 20 ms and estimate the temporal offset using our method. The trajectory-estimation errors and the temporal-offset errors from these experiments are shown in Table IV. The results show that the injected temporal offset can be reliably recovered in this setting.

Fig. 14. Estimated (twist-stereo cam.) and reference (mocap) trajectories with the 3D landmarks, from the Starry Night dataset.
TABLE V
CAMERA-IMU SENSOR EXTRINSIC CALIBRATION RESULTS ON THE EUROC IMU_APRIL SEQUENCE IN THE MONOCULAR CONFIGURATION WITH CAM0 AND IMU0.
| [cm] | (angles) [°] | [ms] | |
|---|---|---|---|
| Kalibr | -1.725 -6.825 0.431 | 0.172 1.303 89.123 | 0.028 |
| Ours | -1.725 -6.796 0.418 | 0.170 1.301 89.130 | 0.021 |
| Deviation | |||
| Mean reprojection error [px]: Kalibr = 0.426, | Ours = 0.453 | ||
- IMU-camera calibration on EuRoC dataset: In this section, we evaluate our calibration approach on the imu_april sequence of the EuRoC Micro Aerial Vehicle dataset [44]. The sensor setup consists of an IMU and a monocular camera. The camera intrinsic parameters and the IMU noise parameters provided in the dataset are used in the estimation.
Unlike in simulation, the calibration target in this case is an AprilGrid [45] board whose reference frame is not aligned with gravity. We assume that the inertial reference frame and the calibration-target reference frame are collocated, but differ in orientation by a tilt, parameterized by roll and pitch angles, . With the new tilt angle, the gravity vector can be expressed with respect to the calibration target reference frame as
where is the nominal rotation that aligns with . The rotation is used to provide an initial guess for the orientation of the calibration target in cases where the tilt angle is large. The value of is then used in the IMU motion model (24). In this case, the motion prior error (32) is a function of the tilt angle, in addition to the robot state and biases. For the imu_april sequence, we initialize using the quaternion .
The initial IMU-camera extrinsic parameters are perturbed from their reference values provided with the dataset, and the estimator is initialized using the procedure described in Section VII-A. Note that the calibration sequence does not have ground-truth information for the extrinsic parameters or the trajectory. We compare our approach to Kalibr [2]. Since the sensors are hardware synchronized, the expected inter-
TABLE VI
DISTRIBUTION OF SENSOR EXTRINSIC CALIBRATION ERRORS WITH ARTIFICIAL TEMPORAL OFFSETS RANGING FROM -4 ms TO 4 ms ON THE IMU_APRIL SEQUENCE OF EUROC DATASET.
| [cm] | [°] | [ms] |
|---|---|---|
| 0.026 ± 0.006 | 0.022 ± 0.004 | 0.0257 ± 0.001 |
TABLE VII
CAMERA-IMU SENSOR EXTRINSIC CALIBRATION RESULTS ON DATASET-CALIB-IMU#_1024_16 SEQUENCES FROM THE TUM-VI DATASET. , AND ARE DEFINED AS IN TABLE V.
| Seq. | [cm] | [°] | [ms] | Mean reproj. [px] | |
|---|---|---|---|---|---|
| Kalibr | Ours | ||||
| 1 | 0.017 | 0.0154 | 0.002 | 0.137 | 0.134 |
| 2 | 0.029 | 0.0144 | 0.01 | 0.135 | 0.131 |
| 3 | 0.032 | 0.0141 | 0.021 | 0.134 | 0.116 |
| 4 | 0.025 | 0.0146 | 0.016 | 0.133 | 0.116 |
TABLE VIII
ESTIMATED EXTRINSIC PARAMETERS ON DATASET-CALIB-IMU1_1024_16 SEQUENCE OF THE TUM-VI CALIBRATION DATASET.
| [cm] | (angles) [°] | [ms] | |
|---|---|---|---|
| Kalibr | 4.531 -7.303 -4.500 | -88.028 0.496 178.325 | 0.114 |
| Ours | 4.530 -7.319 -4.506 | -88.015 0.495 178.317 | 0.112 |
sensor temporal offset is small; consequently, this experiment also evaluates whether the proposed formulation can recover temporal alignment from real measurements without introducing a spurious offset. We run our proposed method and Kalibr on the first 50s of the imu_april sequence using the cam0 camera. The sensor extrinsic estimates from the two methods are shown in Table V, along with the average reprojection error (33). The estimated extrinsic parameters closely agree with those obtained using Kalibr.
To further verify our approach, we added artificial temporal offsets ranging from -4 ms to 4 ms in increments of 1 ms and ran the calibration routine. Results from these tests are provided in Table VI. We performed additional experiments for temporal offsets with magnitude exceeding 5 ms, where we ran a two-stage calibration procedure: a coarse calibration stage to estimate the temporal offset value, followed by a fine calibration stage. This is necessary because the vertex-to-measurement associations must be updated for larger temporal offsets. The EuRoC IMU is sampled at 200 Hz, corresponding to a sampling period of 5 ms. Consequently, when the temporal offset exceeds one IMU sampling period, the vertices associated with the measurements must be updated. In all cases, we found that the coarse calibration routine estimated the temporal offset to sub-millisecond accuracy, while the fine calibration stage produced spatial extrinsic estimates that agreed with the Kalibr estimates to within sub-millimeter translation and sub-degree rotation differences.
- IMU-camera calibration on TUM-VI dataset: To compare performance across different sensor configurations, we further evaluate our approach on the TUM visual-inertial
(TUM-VI) benchmark [46]. The sensor setup in this case consists of two global-shutter IDS uEye cameras with 195° fisheye lenses that record 1024 × 1024 images at 20 Hz, and a Bosch BMI160 IMU sampled at 200 Hz. The two sensors are hardware synchronized: a common microcontroller triggers the cameras and reads the IMU data. We use the four calibration sequences dataset-calib-imu#_1024_16 for evaluation. Each sequence is recorded in front of an AprilGrid [45], with rapid movement that excites all six degrees of freedom. We use the cam0 camera with the equidistant fisheye intrinsics and the IMU noise parameters provided with the dataset. As in the previous case, we estimate the tilt angle of , as the AprilGrid is not gravity-aligned. We compare against Kalibr on the same four sequences.
The deviations between the proposed and Kalibr estimated extrinsic parameters for each sequence are shown in Table VII. Across the four sequences, the proposed method agrees with Kalibr consistently. The proposed method also achieves a lower mean reprojection error than Kalibr across all four sequences. Estimated extrinsic parameters from the dataset-calib-imul_1024_16 sequence are provided in Table VIII. The estimates agree with Kalibr to within 0.02 cm for the position offset and 0.015° for rotation offset.
- Trajectory estimation with non-ideal clock on EuRoC dataset: In this section, we further evaluate the non-ideal clock formulation on the imu_april sequence by introducing synthetic clock drift into the IMU timestamps. The camera timestamps are left unchanged and define the reference time, while the IMU clock is treated as the non-ideal interoceptive clock. The injected drift is generated using the stochastic clock model (5) and follows the same procedure outlined in Section VIII-A1, with s. Unlike in Section VIII-A1, the original EuRoC IMU timestamps are taken as the reference times . The clock error is obtained by integrating (34), with replaced by , and the IMU timestamps are set as . In this experiment, only the timestamps are modified; the original IMU and camera measurements are retained.
Over 50 s of data, the simulated IMU clock accumulates a temporal displacement of approximately 5 ms relative to the reference clock, as shown in Figure 15. We then apply the proposed non-ideal clock model to jointly estimate the trajectory and the mapping between IMU time and reference time . The same clock-noise density used to generate the synthetic drift is used in the estimator. As convention, we assume the camera extrinsic parameters are known and fix them to the values estimated in the previous section.
The estimated clock error closely follows the injected drift over the sequence as shown in Figure 15, demonstrating that the proposed formulation can recover a time-varying clock
TABLE IX
MEAN REPROJECTION ERROR OF DIFFERENT CLOCK MODELS ON THE IMU_APRIL SEQUENCE WITH ARTIFICIAL DRIFT APPLIED TO THE IMU CLOCK.
| Ideal clock | Non-ideal clock | |
|---|---|---|
| Mean reprojection error [px] | 0.588 | 0.453 |

Fig. 15. (Top) Estimated and true clock error using a non-ideal clock model on the EuRoC dataset. (Bottom) Residual clock error in the estimated reference time .

Fig. 16. Our test platform for data collection and calibration of sensor extrinsic parameters.
discrepancy from real sensor measurements. We additionally compare the mean reprojection error obtained using the ideal- and non-ideal-clock models in Table IX. When the injected clock drift is ignored by assuming an ideal IMU clock, the reprojection error increases. In contrast, explicitly estimating clock drift reduces the reprojection error to a value close to that obtained from the original sequence without clock drift. The results show that the non-ideal clock formulation can reliably track millisecond-scale clock drift while simultaneously estimating the robot trajectory.
C. Experiments
In this section, we evaluate our calibration framework to estimate the sensor extrinsic parameters between an IMU and either a position sensor or a range sensor on a micro aerial vehicle (MAV). Our test platform is a quadrotor equipped with an IMU, an ultrawideband (UWB) radio, and an onboard Jetson TX1 computer (see Figure 16). The experiments are conducted in an indoor flight arena measuring 7 m × 8 m × 3.5 m, with seven UWB anchors placed around the arena.
The flight arena is also equipped with a motion-capture system that uses retroreflective markers to estimate the pose of the quadrotor. The motion-capture system runs on an offboard computer whose clock is not synchronized with the onboard clock. Crucially, the firmware used to acquire data from the motion-capture system, assigns timestamps to the estimated 3D pose only after they arrive at the offboard computer.

Fig. 17. Trajectories estimated with IMU-position (motion capture) and IMU-range (UWB) sensor combinations, alongside the reference trajectory from the motion-capture system (mocap).
Consequently, the reported timestamp may include acquisition, processing, and communication delays. This results in an unknown temporal offset between the IMU data stream and the motion-capture pose estimates. If the motion-capture trajectory is to be used as a source of ground truth, this temporal offset must first be estimated, which motivates our initial set of experiments. As in the previous case, the true value of this temporal offset is unknown. We adopt the following approach to validate our method.
The motion-capture system provides the full 3D pose in the local inertial frame. We use only the position component of this estimate as a measurement in our calibration framework as this corresponds to the IMU-position-sensor calibration setup. Separately, the rotation component is used to derive an estimate of the body-referenced angular velocity. The derived body-referenced angular velocity is then compared with the IMU-reported angular velocity to estimate the unknown temporal offset using the correlation method of [30] as a baseline. Note that the two estimators infer the same temporal offset from different measurement information. Concretely, our framework uses position measurements, whereas the baseline uses rotation motion correlation. In our framework, we also estimate the position offset between motion-capture body-frame origin and the IMU. This offset is expected to be small as the motion-capture-referenced body-frame origin was coarsely aligned with the assumed IMU center.
- IMU-position sensor extrinsic calibration: We performed five flight experiments in which the MAV was piloted manually along different trajectories, with sufficient translation and rotational excitation for calibration. The experiments were conducted at approximately one-hour intervals to assess the variability in the temporal offset over time. The IMU data and the motion-capture data were recorded on the onboard computer at 94 Hz and 100 Hz, respectively. The IMU noise parameters are obtained from the MPU9250 IMU datasheet, and the motion-capture position measurement covariance is set to .
The estimated temporal-offset values from the proposed method and the baseline method are shown in Figure 18. The

Fig. 18. Estimated temporal offset between Vicon position measurements and IMU from real experiments using the baseline 3D motion correlation analysis (MCA) method and our method (Ours). Results for MCA are reported as mean one standard deviation.

Fig. 19. (Left) UWB distance measurements from a real experiment showing the unprocessed ranges to different anchors (A#) over time. (Right) The corresponding histogram of range-measurement residuals across all anchors after compensating for spatial biases and removing outliers.
baseline approach estimates the temporal offset independently over multiple fixed-duration windows of sensor measurements; as such, the results are reported as mean one standard deviation. We see that the temporal offset values from the two methods agree closely and that the temporal offset varies between subsequent runs. The estimated trajectory from one such experiment is shown in Figure 17. We do not use trajectory RMSE as an evaluation metric in this case, as the motion-capture system is used as a source of measurement and therefore does not serve as an independent trajectory reference.
- IMU-range sensor extrinsic calibration: In our second set of experiments, we wish to calibrate the sensor extrinsic parameters between the UWB radio and the IMU on the MAV. Unlike the previous case, the UWB range data and IMU data are both received directly by the onboard computer. The lower-level sensor microcontrollers run real-time operating systems (RTOSs) and communicate with the onboard computer over universal asynchronous receiver-transmitter (UART) links. Since both data streams are received and timestamped by the onboard computer, an offset can arise from the TWR exchange, firmware turnaround, and serial transport, none of which are individually characterized. However, we expect this offset to be small. The IMU data are sampled at 94 Hz and the UWB range measurements are generated at 40 Hz by querying the anchors in a round-robin fashion. The measurement covariance for range data is set to . The position offset is measured manually using a ruler as m.
It has been observed previously that UWB radios exhibit spatially varying biases and outliers [47] under non-line-of-sight (NLOS) conditions. We post-process the range measure-
| Sensor | Estimated Temporal offset τd[ms] |
| IMU-UWB | 0.1 ± 3.77 |

Fig. 20. (Top) Estimated IMU-UWB temporal offset from five real experiments. (Bottom) Corresponding trajectory-estimation RMSE computed with (w. ) and without (w/o. ) compensating for the IMU-motion-capture temporal offset estimated in the previous experiment.
ment data using the pose obtained from the motion-capture system to compensate for spatially varying biases and outliers. A histogram of post-processed range measurement errors from one such experiment is shown in Figure 19.
As in the previous case, we performed multiple experiments in which the quadrotor was manually piloted along different trajectories and the sensor data were recorded on the onboard computer for offline evaluation. The estimated IMU-range temporal offsets from five flight experiments are shown in Figure 20. The estimated trajectory from one such experiment is shown in Figure 17. We observed that the estimated position offset was not consistent across the trials, so we used the hand-measured value in all of our experiments. The inconsistency is not unexpected, as the range-measurement noise has a standard deviation of cm (see Figure 19), which is comparable to the magnitude of the position offset.
We evaluate the trajectory estimation accuracy by comparing the estimated trajectory against the pose reported by the motion-capture system. Since the motion-capture timestamps are not synchronized with the IMU clock, we first correct them using the IMU-motion-capture temporal offset estimated in the preceding section, so that both trajectories are expressed with respect to IMU time. We then compute the trajectory RMSE with and without applying this temporal calibration to the motion-capture trajectory. As shown in Figure 20, accounting for the temporal offset generally yields a lower RMSE, as the uncompensated motion-capture trajectory contains a residual time lag relative to the IMU-UWB trajectory. We cannot use the correlation-based approach [30] from the previous section as a baseline because it requires rotational-motion information from both sensors, which is unavailable in this case.
Since the temporal offsets observed in the IMU-UWB experiments are small, we further validate our calibration approach by injecting artificial temporal offsets ranging from -30 ms to 30 ms into the recorded UWB range data, following the procedure used in Section VIII-B2. The resulting estimation errors are reported in Table X. The results also suggest that, in this setup, temporal-offset estimation is more robust to sensor noise than estimation of the spatial offset .
TABLE X
ESTIMATION ERRORS FROM A REAL EXPERIMENT WITH ARTIFICIAL TEMPORAL OFFSETS RANGING FROM -30 ms TO 30 ms INJECTED INTO THE UWB RANGE DATA. VALUES ARE REPORTED AS MEAN ± ONE STANDARD DEVIATION ACROSS THE TESTED TEMPORAL OFFSETS.
| Position RMSE [cm] | Rotation RMSE [°] | ετd [ms] |
| 10.5 ± 0.000 | 2.886 ± 0.002 | 0.085 ± 0.648 |
IX. CONCLUSION
We presented a group-theoretic framework for joint trajectory estimation and spatiotemporal sensor calibration using the special Galilean group. The robot trajectory is represented on SGal(3), while sensor extrinsic parameters are represented on Arist(3), allowing spatial and temporal calibration parameters to be handled within a unified state representation. We developed motion priors for twist and IMU measurements, considered both ideal and non-ideal interoceptive clock models, and introduced a reduced tangent-space formulation for the ideal-clock case.
The proposed framework was evaluated in simulation and on real datasets using position, range, and camera measurements. The experiments demonstrate accurate estimation of spatial and temporal extrinsic parameters and show that explicitly modeling a non-ideal interoceptive clock improves trajectory and clock estimation when the clock model has nonidealities present. The results support the use of Galilean-group structure as a practical approach for spatiotemporal calibration and trajectory estimation with heterogeneous sensors.
ACKNOWLEDGMENT
Claude (Anthropic) and ChatGPT (OpenAI) were used in supporting capacity for manuscript editing, code development, and figure preparation.
APPENDIX
A. Model decomposition for Twist-driven motion model
In this section, we decompose the model (8) into nominal and error models. We perturb (8) around the nominal values and , using the first-order input decomposition of the group-affine model (9):
where . We derive a first-order approximation to the above model (36) as
where we have used . The second line in (37) is obtained by excluding the second-order perturbation terms. The nominal model has the form
The corresponding error model is obtained by substituting the nominal model in (37) as
where .
B. Model decomposition for IMU-driven motion model
The motion model (20) is decomposed into nominal and error models, which are used to propagate the nominal state and the error state , respectively:
where, as before, second-order perturbations have been dropped (see footnote 2). The biases are decomposed as
where . The nominal model from 38 is
To obtain the corresponding error model, we substitute the nominal model in (38) and collect the first-order terms:
where we have used the identity for .
Discrete-time model: The discrete-time state propagation equation from (24) has the form
where with , , and is the state at time . To verify (24) satisfies the nominal model, we look at the derivative at :
where follows from the from fundamental theorem of calculus under our piecewise-constant input assumption, and . The term involving involves further explanation as is a function of s. We have
if , which is the case here:
where , and
Evaluating the above equations at , recovers (21).
C. Reduced tangent space operators
To construct mappings between a subalgebra and its ambient Lie algebra/group representation, we restrict the corresponding group operators. Since is a subalgebra of , setting eliminates the coupling term in (2), reducing it exactly to the exponential map of . We define the inclusion as , and the projection . The mappings between the subalgebra and ambient representations are
where the subscripts denote the ambient group for the element or operation. Importantly, this reduction is also consistent with Jacobians required in subsequent computations. The adjoint ad of is block upper-triangular [8, Section 7.], and every Jacobian expressible as power series of the adjoint inherits this structure. Concretely, when the upper-left block of the Galilean left Jacobian is identical to the left Jacobian of [34, Table 1.]:
so no approximation is incurred by this reduction. Here and denote the left Jacobians of corresponding groups.
REFERENCES
[1] Jonathan Kelly and Gaurav S. Sukhatme. Visual-inertial sensor fusion: Localization, mapping and sensor-to-sensor Self-calibration. International Journal of Robotics Research, 30(1):56–79, 2011.
[2] Paul Furgale, Joern Rehder, and Roland Siegwart. Unified temporal and spatial calibration for multi-sensor systems. In Proc. of the RSJ International Conference on Intelligent Robots and Systems (IROS), pages 1280–1286, Tokyo, November 2013. IEEE.
[3] Abhishek Goudar and Angela P. Schoellig. Online Spatio-temporal Calibration of Tightly-coupled Ultrawideband-aided Inertial Localization. In Proc. of the RSJ International Conference on Intelligent Robots and Systems (IROS), pages 1161–1168, Prague, Czech Republic, September 2021. IEEE.
[4] Patrick Geneva, Kevin Eckenhoff, Woosik Lee, Yulin Yang, and Guoquan Huang. OpenVINS: A Research Platform for Visual-Inertial Estimation. In Proc. of the International Conference on Robotics and Automation (ICRA), pages 4666–4672. IEEE, 2020.
[5] Paul Furgale, Chi Hay Tong, Timothy D. Barfoot, and Gabe Sibley. Continuous-time batch trajectory estimation using temporal basis functions. International Journal of Robotics Research, 34(14):1688–1710, 2015.
[6] Emmett Wise, Juraj Persic, Christopher Grebe, Ivan Petrovic, and Jonathan Kelly. A Continuous-Time Approach for 3D Radar-to-Camera Extrinsic Calibration. In Proc. of the International Conference on Robotics and Automation (ICRA), pages 13164–13170, Xi'an, China, May 2021. IEEE.
[7] Juraj Persic, Luka Petrovic, Ivan Markovic, and Ivan Petrovic. Spatiotemporal Multisensor Calibration via Gaussian Processes Moving Target Tracking. IEEE Transactions on Robotics, pages 1–15, 2021.
[8] Jonathan Kelly. All About the Galilean Group SGal(3). arXiv:2312.07555, February 2026.
[9] Robert Mahony, Jonathan Kelly, and Stephan Weiss. Galilean Symmetry in Robotics. arXiv:2510.10468, October 2025.
[10] Giulio Delama, Martin Scheiber, Yixiao Ge, Tarek Hamel, Stephan Weiss, and Robert Mahony. Galilean State Estimation for Inertial Navigation Systems with Unknown Time Delay. arXiv:2605.13266, May 2026.
[11] Jonathan Kelly. A Sliding Window Filter on the Galilean Group for Consistent Aided Inertial Navigation with Unknown Measurement Delays. arXiv:2608.29514, September 2026.
[12] Eric Bergshoeff, José Figueroa-O'Farrill, and Joaquim Gomis. A Non-Lorentzian Primer. SciPost Physics Lecture Notes, page 69, May 2023.
[13] Richard M. Murray, Zexiang Li, and S. Shankar Sastry. A Mathematical Introduction to Robotic Manipulation. CRC Press, Boca Raton, FL, USA, 1994.
[14] Gregory S. Chirikjian. Stochastic Models, Information Theory, and Lie Groups, Volume 2: Analytic Methods and Modern Applications, chapter 11, pages 361–388. Birkhäuser Boston, Boston, 2012.
[15] Timothy D. Barfoot. State Estimation for Robotics: Second Edition. Cambridge University Press, January 2024.
[16] Timothy D. Barfoot and Paul T. Furgale. Associating uncertainty with three-dimensional poses for use in estimation problems. IEEE Transactions on Robotics, 30(3):679–693, 2014.
[17] Joshua G. Mangelson, Maani Ghaffari, Ram Vasudevan, and Ryan M. Eustice. Characterizing the uncertainty of jointly distributed poses in the Lie algebra. IEEE Transactions on Robotics, 36(5):1371–1388, 2020.
[18] Axel Barrau and Silvere Bonnabel. The invariant extended Kalman filter as a stable observer. IEEE Transactions on Automatic Control, 62(4):1797–1812, 2017.
[19] Axel Barrau and Silvère Bonnabel. Invariant Kalman Filtering. Annual Review of Control, Robotics, and Autonomous Systems, 1(1):237–257, May 2018.
[20] Easton R. Potokar, Randal W. Beard, and Joshua G. Mangelson. An Introduction to the Invariant Extended Kalman Filter [Lecture Notes]. IEEE Control Systems, 44(6):50–71, December 2024.
[21] Alessandro Fornasier, Yonhon Ng, Robert Mahony, and Stephan Weiss. Equivariant Filter Design for Inertial Navigation Systems with Input Measurement Biases. In Proc. of the International Conference on Robotics and Automation (ICRA), pages 4333–4339, Philadelphia, PA, USA, May 2022. IEEE.
[22] Pieter Van Goor, Tarek Hamel, and Robert Mahony. Equivariant Filter (EqF). IEEE Transactions on Automatic Control, 68(6):3501–3512, June 2023.
[23] Axel Barrau and Silvere Bonnabel. A Mathematical Framework for IMU Error Propagation with Applications to Preintegration. In Proc. of the International Conference on Robotics and Automation (ICRA), pages 5732–5738, Paris, France, May 2020. IEEE.
[24] Jonathan Kelly and Matthew Giamou. Uncertainty in space, time, and motion on the special Galilean group. arXiv:2602.13327, February 2026.
[25] Giulio Delama, Alessandro Fornasier, Robert Mahony, and Stephan Weiss. Equivariant IMU Preintegration with Biases: a Galilean Group Approach. IEEE Robotics and Automation Letters, pages 1–8, 2024.
[26] Carlos Pérez-Ruiz and Joan Solà. LIMOncello: Iterated Error-State Kalman Filter on the SGal(3) Manifold for Fast LiDAR-Inertial Odometry. arXiv:2512.19567, January 2026.
[27] Mingyang Li and Anastasios I. Mourikis. Online temporal calibration for camera-IMU systems: Theory and algorithms. International Journal of Robotics Research, 33(7):947–964, 2014.
[28] Karol Hausman, Stephan Weiss, Roland Brockers, Larry Matthies, and Gaurav S. Sukhatme. Self-calibrating multi-sensor fusion with probabilistic measurement validation for seamless sensor switching on a UAV. In Proc. of the International Conference on Robotics and Automation (ICRA), pages 4289–4296, Stockholm, Sweden, May 2016. IEEE.
[29] Junlin Song, Antoine Richard, and Miguel Olivares-Mendez. Unleashing the Power of Discrete-Time State Representation: Ultrafast Target-based IMU-Camera Spatial-Temporal Calibration. arXiv:2509.12846, February 2026.
[30] Kejie Qiu, Tong Qin, Jie Pan, Siqi Liu, and Shaojie Shen. Real-Time Temporal and Rotational Calibration of Heterogeneous Sensors Using Motion Correlation Analysis. IEEE Transactions on Robotics, pages 1–16, 2021.
[31] Christiane Sommer, Vladyslav Usenko, David Schubert, Nikolaus Demmel, and Daniel Cremers. Efficient Derivative Computation for Cumulative B-Splines on Lie Groups. In 2020 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR), pages 11145–11153, June 2020.
[32] Lino Antoni Giefer. Uncertainties in Galilean Spacetime. In Proc. of the 24th International Conference on Information Fusion (FUSION), pages 1–8, Sun City, South Africa, November 2021. IEEE.
[33] Marlis Hochbruck and Alexander Ostermann. Exponential integrators. Acta Numer., 19:209–286, may 2010.
[34] Timothy D. Barfoot. Integral Forms in Matrix Lie Groups. arXiv:2503.02820, March 2025.
[35] Timothy D. Barfoot, Chi Hay Tong, and Simo Särkkä. Batch Continuous-Time Trajectory Estimation as Exactly Sparse Gaussian Process Regression. Robotics: Science and Systems, 2014.
[36] Keenan Burnett, Angela P. Schoellig, and Timothy D. Barfoot. IMU as an input versus a measurement of the state in inertial-aided state estimation. Robotica, pages 1–21, January 2025.
[37] Charles F Van Loan. Computing Integrals Involving the Matrix Exponential. IEEE Transactions on Automatic Control, 23(3):395–404, 1978.
[38] Paloma Sodhi, Sanijban Choudhury, Joshua G. Mangelson, and Michael Kaess. ICS: Incremental Constrained Smoothing for State Estimation. In Proc. of the International Conference on Robotics and Automation, pages 279–285. IEEE, 2020.
[39] Martin Brossard, Axel Barrau, Paul Chauchat, and Silvere Bonnabel. Associating Uncertainty to Extended Poses for on Lie Group IMU Preintegration With Rotating Earth. IEEE Transactions on Robotics, 38(2):998–1015, April 2022.
[40] Sameer Agarwal, Keir Mierle, and The Ceres Solver Team. Ceres Solver, 10 2023.
[41] Hauke Strasdat. Sophus: C++ implementation of lie groups using eigen. https://github.com/strasdat/sophus, 2012.
[42] Simo Särkkä and Arno Solin. Applied Stochastic Differential Equations. Institute of Mathematical Statistics Textbooks. Cambridge University Press, 2019.
[43] Karol Hausman, James Preiss, Gaurav S. Sukhatme, and Stephan Weiss. Observability-Aware Trajectory Optimization for Self-Calibration With Application to UAVs. IEEE Robotics and Automation Letters, 2(3):1770–1777, 2017.
[44] Michael Burri, Janosos Nikolic, Pascal Gohl, Thomas Schneider, Joern Rehder, Sammy Omari, Markus W Achtelik, and Roland Siegwart. The EuRoC micro aerial vehicle datasets. The International Journal of Robotics Research, 35(10):1157–1163, September 2016.
[45] Edwin Olson. AprilTag: A robust and flexible visual fiducial system. In Proc. of the International Conference on Robotics and Automation (ICRA), pages 3400–3407, Shanghai, China, May 2011. IEEE.
[46] David Schubert, Thore Goll, Nikolaus Demmel, Vladyslav Usenko, Jörg Stückler, and Daniel Cremers. The TUM VI benchmark for evaluating visual-inertial odometry. In Proc. of the International Conference on Intelligent Robots and Systems (IROS), pages 1680–1687, 2018.
[47] Abhishek Goudar, Wenda Zhao, and Angela P. Schoellig. Range-Visual-Inertial Sensor Fusion for Micro Aerial Vehicle Localization and Navigation. IEEE Robotics and Automation Letters, 9(1):683–690, January 2024.