arXiv:2611.08754Measurement-Aware Multimodal LLM for No-Reference Low-Dose CT Quality Assessment
Kerem Basim, Tolga Demiroglu, Mehmet Ozan Unal, Metin Ertas, Isa Yildirim
Dept. of Electronics and Communication Eng., Istanbul Technical University, Istanbul, Turkey
Dept. of Electrical and Electronics Eng., Istanbul University, Istanbul, Turkey
{basim21, unalmehmet, iyildirim}@itu.edu.tr, tolgadem7@gmail.com, ertas@istanbul.edu.tr
Equal contribution
Abstract—No-reference image quality assessment (IQA) of low-dose CT predicts the score that radiologists would assign to a slice without a full-dose reference, as needed to compare dose protocols and denoisers. Trained CT IQA networks agree well with radiologists but output only a score, whereas multimodal large language models (MLLMs) can explain a score but perform poorly on CT when only prompted. We propose a measurement-aware MLLM, built on Qwen3.8-27B, that rates a slice from its image together with six image-domain measurements of noise, sharpness, high-frequency content and streaks, given to the language model as percentiles in text. On the LDCT-IQA 2023 test set, it reaches an Overall score of 2.735, on par with the retrained challenge winner (2.735) and MedSigLIP-FiLM (2.713), and substantially above its base MLLM used as a zero-shot agent. Shuffling the measurements at test time reduces the score by 0.048, mostly through noise, but the same measurements also lead the model to assign higher scores to over-smoothed denoised images.
Index Terms—Low-dose CT, image quality assessment, multimodal large language models, fine-tuning, interpretability
I. INTRODUCTION
Lowering the dose of a CT scan reduces radiation risk but increases noise and streak artifacts, and the deep learning denoisers that remove them can over-smooth fine anatomy. Comparing dose protocols and denoisers therefore requires image quality assessment (IQA) that agrees with radiologists, and manual scoring by radiologists is impractical at scale [1]. Since no full-dose reference exists in clinical practice, the assessment must be no-reference, that is, a model predicts the mean opinion score (MOS) of radiologists from the slice alone. The LDCT-IQA 2023 challenge [1] established this task as a benchmark of abdominal CT slices scored by radiologists from 0 (worst) to 4 (best).
On this benchmark, trained networks achieve high correlation with the MOS. The challenge was won by an ensemble of convolutional and transformer classifiers [2], later work adapted medical foundation models such as MedSigLIP-FiLM [3], and a recent method reports a higher score [4]. Such scores, however, depend on the evaluation protocol. Rounding predictions to the 0.2 MOS grid changes Kendall's , and choosing a model configuration by its test-set score inflates the result. Moreover, these networks output only a score, whereas multimodal large language models (MLLMs) can also explain a score in words. Prompted general MLLMs [5] and a vision-language model paired with ChatGPT [6] assess CT quality in text, but on LDCT-IQA prompting remains substantially below trained networks (Table I). A medical MLLM fine-tuned for CT quality [7] also remains below them. For natural images and videos, MLLMs are either fine-tuned to output a quality score [8], [9] or given IQA tools that they call and reason over in an agent loop [10]–[13].
For CT, the natural counterpart of such tools are the physical measurements with which image quality is conventionally characterized, such as noise magnitude and edge sharpness [14], [15], and an MLLM can read them as text. However, it remains unclear whether an MLLM fine-tuned with these measurements reaches the accuracy of trained CT IQA networks, and whether it actually uses them. We propose a measurement-aware MLLM that rates a slice from the image together with six measurements in four groups (noise, sharpness, high-frequency content and streaks), given as percentiles in text (Fig. 1b). We compare this model with its base MLLM, Qwen3.8-27B, used as a zero-shot agent over precomputed measurements and visual views (Fig. 1a). Our contributions are (i) a measurement-aware MLLM that is on par with the strongest trained CT IQA networks on LDCT-IQA 2023 (Table I); (ii) ablation and test-time shuffling experiments showing that the model relies on the measurement values, mainly on noise, and that the same inputs lead it to assign higher scores to over-smoothed denoised images (Tables II and III, Fig. 2); and (iii) an evaluation under a fixed protocol, with the effect of rounding to the 0.2 MOS grid and configurations selected on the test set reported separately.
For each slice we compute six scalar measurements that capture the degradations caused by dose reduction and denoising. They fall into four groups. Noise is measured by the standard deviation of the residual after a median filter (residual noise) and by a noise score defined below. Sharpness is measured by the 95th percentile of the Sobel gradient magnitude (structure) and by the mean deviation of
This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may no longer be accessible.

Fig. 1. Two ways to give Qwen3.8-27B CT quality measurements. (a) Zero-shot agent: it reads precomputed tool outputs (measurements and visual views) in a loop, 2.8 reads per image on average, and writes a score and a rationale (Overall 2.18). (b) Our fine-tuned model: six measurement percentiles are written as text after the image tokens of a CT-tuned vision encoder; LoRA adapters and a linear head on the last token are trained to predict the MOS (Overall 2.73). Tiles are from a training slice and computed with simple definitions for illustration.
this magnitude from its Gaussian-smoothed version (gradient deviation). Fine texture is the mean absolute high-frequency residual (HF residual), and streaks are the angular non-uniformity of the mid-frequency residual power inside the body (streak anisotropy). Because the raw values differ in units, we express each as a percentile . The percentile is the share of the 1000 training slices with a larger value, so for the noise measurements a higher means less noise than usual. The noise score is the mean of the residual noise, gradient deviation and HF residual percentiles. No MOS is used in this step. The six two-digit percentiles are inserted into a fixed prompt (“... each number is the percent of reference slices that measure higher ... Rate the overall image quality from 0 (worst) to 4 (best).”), which the LLM reads together with the image tokens.
We build the model on Qwen3.8-27B [16], whose vision encoder converts the image into tokens that a merger projects into the language model (Fig. 1b). Phase 1 adapts this general-purpose encoder to CT. We fine-tune with a small regression head on its pooled tokens and the six percentiles, using the mean squared error (MSE) on standardized MOS for 10 epochs. Phase 2 keeps frozen and trains the language model to process the image tokens and the measurement text jointly. It updates the merger, LoRA adapters [17] of rank 16 on every projection of all 64 language-model layers (bf16), and a linear head on the hidden state of the last prompt token, again with MSE, for 3 epochs. The test prediction averages the models of the 5 cross-validation folds.
To test whether the same kind of evidence helps without training, we also run Qwen3.8-27B as a zero-shot agent (Fig. 1a), following AgenticiQA and Tool-IQA [10], [11]. Its tool outputs, precomputed for each image, are a file of CT measurements with their percentiles among the training
slices and seven visual views (e.g. soft-tissue window, noise residual map, Fourier spectrum). The agent opens the image and these files with file-read calls and writes a score and a short rationale.
We evaluate all models with the challenge score [1], Overall , the sum of the linear, rank and pairwise-rank correlations with the MOS (KROCC as Kendall's , maximum 3). The MOS is the mean of the radiologists' scores and therefore takes values on a 0.2 grid. Predictions can be rounded to the same grid, . Rounding creates tied pairs, which changes KROCC, so we report Overall with and without rounding for every model we ran. To limit selection on the test set, all comparisons and tests were fixed before the first evaluation on it. Confidence intervals (CIs) come from a paired bootstrap over the 300 test slices (2000 resamples) [18], and -values are Holm-corrected [19] within each table. Since denoised images have no MOS, the denoiser measures whether a model ranks the reconstructions of a slice by fidelity. It is the Kendall between predicted quality and SSIM to the full-dose reference, averaged over slices. One caveat remains. The rule fixed in advance selects by out-of-fold score and picked the Phase 1 model, whereas the Phase 2 model was promoted after the test evaluation; a rerun with the same seed reproduced its score.
III. EXPERIMENTS AND RESULTS
We train and test on LDCT-IQA 2023 [1], which provides 1000 training and 300 test abdominal slices from 7 and 5 patients. We split the training slices (about 100 base slices, each degraded at several levels) into 5 folds grouped by base slice and evaluate on the official test set. Because one patient's slices can span folds, out-of-fold scores overestimate test performance (Overall gap 0.118, and 0.017 with folds that also separate likely same-patient slices). For denoised images,
TABLE I
RESULTS ON THE LDCT-IQA 2023 TEST SET (300 SLICES) AND ON DENOISED IMAGES (). ALL MODELS WE RAN ARE TRAINED ON OUR FOLDS AS 5-FOLD ENSEMBLES AND EVALUATED UNDER A PROTOCOL FIXED IN ADVANCE (OUR MODEL'S SELECTION: SEC. II); LMM-IQA AND MEDGEMMA ARE CITED FROM THEIR PAPERS. GRID: PREDICTIONS ROUNDED TO THE 0.2 MOS GRID. : STD OVER THREE TRAINING SEEDS (POINT VALUES ARE THE ORIGINAL RUNS; FOR MEDSigLIP-FiLM ITS BEST SEED). : DIFFERENCE TO MEDSigLIP-FiLM, PAIRED BOOTSTRAP OVER THE 300 SLICES. † HOLM-ADJUSTED AGAINST OURS. BOLD: BEST OF THE ROWS ABOVE THE BOTTOM BLOCK. BOTTOM BLOCK: PUBLISHED RESULTS AND OUR CONFIGURATIONS CHOSEN ON THE TEST SET, NOT COMPARABLE TO THE ROWS ABOVE.
| Method | PLCC ↑ | SROCC ↑ | KROCC ↑ | Overall ↑ | Overall, grid ↑ | Δ [95% CI] | ↑ |
|---|---|---|---|---|---|---|---|
| Prompted MLLMs | |||||||
| LMM-IQA, o3 [5] | .8122 | .8180 | .6347 | 2.2649 | - | - | - |
| Qwen3.8-27B agent (ours, Z3) | .7825 | .7859 | .6117 | 2.1802 | 2.1919 | -0.533 [-0.668, -0.415] | - |
| Fine-tuned MLLMs | |||||||
| MedGemma-4B QLoRA, own split [7] | .791 | .795 | - | - | - | - | - |
| Q-Align [8] | .9095 | .9055 | .7422 | 2.5572† | 2.5779 | -0.156 [-0.210, -0.109] | 0.392 |
| Trained CT IQA | |||||||
| ResNeXt-50 | .9426 | .9410 | .7989 | 2.6825† | 2.6968 | -0.031 [-0.049, -0.013] | 0.029 |
| Challenge winner [1], [2] | .9534 | .9543 | .8275 | 2.7352 | 2.7363 | +0.022 [-0.002, +0.045] | 0.436 |
| MedSigLIP-FiLM [3] | .9490 ± .0103 | .9491 ± .0051 | .8152 ± .0098 | 2.7132 ± .0251 | 2.7327 | reference | 0.480 |
| Ours: Qwen3.8-27B + meas. | .9543 ± .0015 | .9537 ± .0015 | .8265 ± .0031 | 2.7345 ± .0060 | 2.7581 | +0.021 [+0.002, +0.041] | 0.140 |
| Published or chosen on the test set | |||||||
| Challenge winner, class-grid output [1], [2] | .9491 | .9495 | .8440 | - | 2.7427 | - | - |
| ClinReadNet [4] | - | - | - | - | 2.7690 | - | - |
| MedSigLIP-FiLM, test-selected | - | - | - | - | 2.7694 | - | - |
| Ours, test-selected | - | - | - | - | 2.7767 | - | - |



Fig. 2. What the models rely on. (a) Our model, partial dependence (fold 1): its mean prediction moves mostly with the noise measurements. (b) The zero-shot agent opens a visual view most often for the worst images (MOS 0–1); numbers on the bars are reads per image. (c) Agent absolute error by the measurement group its rationale cites (95% bootstrap CIs).
we built a set of 192 soft-tissue slices from 30 DeepLesion patients [20]. Each slice has its full-dose reference and 12 reconstructions, namely a noisy low-dose version and the outputs of 11 denoisers (e.g. BM3D, RED-CNN, DnCNN), and serves only for . We train MedSigLIP-FiLM [3] with its original code and checkpoints, like our model with three seeds, and retrain the transformer classifiers of the challenge winner [1], [2] and Q-Align [8] on our folds with their own recipes, and add a ResNeXt-50 as a standard CNN baseline. The code is available at https://github.com/itu-biai/agentic-ct-iqa.
Table I shows that our model is on par with the strongest trained CT IQA networks. It reaches an Overall of 2.735, 0.021 above MedSigLIP-FiLM in the primary comparison (95% CI [+0.002, +0.041]). This difference is not significant after Holm correction (), although our model is ahead at all three seed pairings. The difference to the retrained challenge winner is close to zero (-0.001 [-0.018, +0.016]), whereas Q-Align and ResNeXt-50 are significantly lower. These scores are also sensitive to the evaluation protocol. Rounding to
the 0.2 grid adds 0.024 to our model but only 0.001 to the challenge winner, whose 21-class output already lies on the grid. This rounding effect is larger than the gap between our model and MedSigLIP-FiLM (0.021), so differences between the top methods on this benchmark are only meaningful when all models are evaluated with the same rounding. Selecting the configuration on the test set raises MedSigLIP-FiLM further, to 2.769, the score reported for ClinReadNet [4] (Table I, bottom). On denoised images, however, the ranking reverses. Our model reaches , against 0.480 for MedSigLIP-FiLM and 0.436 for the winner.
Table II isolates the contribution of each component. Without training, the measurement text increases the Overall of Qwen3.8-27B from 1.370 to 2.157, the agent loop adds no significant gain (2.180), and 80 example slices with their MOS increase it only to 2.483 (rows Z1–Z4). Among the trained models, tuning the vision encoder gives the largest improvement (T2 vs T1, +0.135), and the tuned encoder represents noise better than the pretrained one (linear-probe
TABLE II
ABLATION. EACH ROW CHANGES ONE COMPONENT, WITH THE SAME FOLDS, SEED AND 5-FOLD ENSEMBLE. MEAS.: THE SIX MEASUREMENT PERCENTILES AS TEXT. : AGAINST THE ROW ABOVE. HOLM-ADJUSTED . BOLD: OUR MODEL.
| Configuration | Overall | [95% CI] | |
|---|---|---|---|
| Zero-shot Qwen3.8-27B (no training) | |||
| Z1 Image only | 1.370 | - | - |
| Z2 + meas. as text | 2.157 | +0.787 [+0.545, +1.028] | - |
| Z3 + agent loop (files, views) | 2.180 | +0.023 [-0.125, +0.173] | - |
| Z4 + 80 examples with MOS | 2.483 | +0.302 [+0.179, +0.436] | - |
| Trained, no LLM | |||
| T0 Meas. only (boosting) | 2.611 | - | 0.056 |
| T1 Frozen enc. + ridge | 2.569 | - | 0.442 |
| T2 Tuned enc. | 2.704 | +0.135 [+0.098, +0.174] | 0.213 |
| T3 + meas. in head (Phase 1) | 2.719 | +0.015 [+0.008, +0.022] | 0.150 |
| Trained, with LLM (LoRA) | |||
| T4 Frozen enc. + LLM + meas. | 2.711 | - | 0.149 |
| T5 Tuned enc. + LLM, no meas. | 2.719 | - | 0.250 |
| T6 Tuned enc. + LLM + meas. | 2.7345 | +0.015 [+0.005, +0.025] | 0.140 |
| T7 Ours, meas. shuffled at test | 2.687 | -0.048 [-0.070, -0.027] | 0.222 |
TABLE III
WHAT THE MODELS RELY ON. OURS: CHANGE IN OVERALL WHEN ONE MEASUREMENT GROUP IS SHUFFLED ACROSS TEST IMAGES (5 PERMUTATIONS). AGENT: SHARE OF IMAGES ON WHICH IT READ EACH GROUP, CITED IT (FROZEN KEYWORD RULES), AND THE CITATION AGREED WITH THE MEASURED PERCENTILE. HOLM-ADJUSTED . * A HUMAN READER CODED NOISE IN 90 TO 94%. RULES NOT CONFIRMED BY A HUMAN READER ().
| Group | Ours | Zero-shot agent (%) | ||
|---|---|---|---|---|
| shuffled [95% CI] | read | cited | agrees [95% CI] | |
| Noise level | -0.024 [-0.043, -0.007] | 100 | 99.7 | 76.8 [72.0, 81.9] |
| Sharpness | -0.005 [-0.012, +0.001] | 100 | 52.3 | 90.3 [85.7, 94.2] |
| HF residual | -0.002 [-0.007, +0.002] | 100 | 10.3 | 87.1 [74.2, 96.8] |
| Streaks | -0.006 [-0.014, +0.001] | 100 | 15.0 | 80.0 [68.9, 91.1] |
| Visual views | - | 66.0 | - | - |
| All shuffled (T7) | -0.048 [-0.070, -0.027] | - | - | - |
| Reads per image | 2.84 | - | - | |
0.91 vs 0.83). Once the LLM receives the measurements, however, the advantage of the tuned over a frozen encoder is no longer significant (T6 vs T4). The measurement text itself adds 0.015 (T6 vs T5), and shuffling it across test images more than offsets this gain (T7, -0.048). The same text also explains the poor ranking of denoised images. It lowers from 0.250 to 0.140, and shuffling it restores to 0.222.
Among the measurements, our model relies mainly on noise. Shuffling one group at a time significantly reduces Overall only for noise (-0.024, Table III), and the mean prediction changes by 0.32 MOS across the noise percentiles but by at most 0.09 for the other groups (Fig. 2a). The zero-shot agent also relies on noise, but less consistently. It reads the measurement file for every image and opens a visual view for 66%, most often for the worst images (Fig. 2b). Its rationales cite noise almost always, yet the cited direction agrees with the measured percentile for only 77% of images. These citations were counted with keyword rules fixed in advance, which a human reader confirmed for sharpness and HF () and for the direction of noise citations (96%), but not for streaks. The agent's error is similar across the cited groups (overlapping 95% CIs, Fig. 2c), and removing the noise tools changes 41% of its scores by more than 0.25 MOS without changing its Overall. The rationales therefore describe the measurements but do not reliably explain the scores.
IV. CONCLUSION
A measurement-aware MLLM that reads six image measurements as text together with the CT image is on par with the strongest trained networks on LDCT-IQA 2023, whereas its base MLLM as a zero-shot agent scores substantially lower. The model relies mainly on the noise measurements, which also lead it to overrate over-smoothed denoised images and limit its use for ranking denoisers. The study is limited to 7 training patients, one benchmark and one LLM, and the denoised set has no MOS. Future work will add training images with denoiser blur and evaluate smaller MLLMs.
REFERENCES
[1] W. Lee et al., “Low-dose computed tomography perceptual image quality assessment,” Medical Image Analysis, vol. 99, p. 103343, Jan. 2025.
[2] A. Galdran, “First-place solution to the LDCT-IQA 2023 challenge,” https://github.com/agaldran/ldct_iqa, 2023, GitHub repository.
[3] T. Demiroglu, M. O. Unal, M. Ertas, and I. Yildirim, “Prompt-conditioned FiLM and multi-scale fusion on MedSigLIP for low-dose CT quality assessment,” arXiv:2511.12256, 2025. [Online]. Available: https://arxiv.org/abs/2511.12256
[4] X. Xiao et al., “ClinReadNet: A clinical reading-inspired network for low-dose abdominal CT image quality assessment,” arXiv:2606.10372, 2026.
[5] K. Celik, M. O. Unal, M. Ertas, and I. Yildirim, “LMM-IQA: Image quality assessment for low-dose CT imaging,” arXiv:2511.07298, 2025. [Online]. Available: https://arxiv.org/abs/2511.07298
[6] Z. Chen et al., “IQAGPT: computed tomography image quality assessment with vision-language and ChatGPT models,” Visual Computing for Industry, Biomedicine, and Art, vol. 7, no. 1, Aug. 2024.
[7] J. Wang, Y. Sun, S. Bayer, and A. Maier, “Explainable radiologist-aligned VLM for CT image quality assessment,” in Bildverarbeitung für die Medizin 2026. Springer Fachmedien Wiesbaden, 2026, pp. 387–392.
[8] H. Wu et al., “Q-Align: Teaching LMMs for visual scoring via discrete text-defined levels,” arXiv:2312.17090, 2023. [Online]. Available: https://arxiv.org/abs/2312.17090
[9] T. Wu, J. Zou, J. Liang, L. Zhang, and K. Ma, “VisualQuality-R1: Reasoning-induced image quality assessment via reinforcement learning to rank,” arXiv:2505.14460, 2025. [Online]. Available: https://arxiv.org/abs/2505.14460
[10] H. Zhu et al., “AgenticIQA: An agentic framework for adaptive and interpretable image quality assessment,” arXiv:2509.26006, 2025. [Online]. Available: https://arxiv.org/abs/2509.26006
[11] G. Qin et al., “Tool-IQA: Augmenting image quality assessment with simple tools,” arXiv:2606.16082, 2026. [Online]. Available: https://arxiv.org/abs/2606.16082
[12] J. Wu et al., “IQA-T1: Tool-based visual evidence reasoning for image quality assessment,” arXiv:2607.12375, 2026. [Online]. Available: https://arxiv.org/abs/2607.12375
[13] S. Xing et al., “Q-Router: Agentic video quality assessment with expert model routing and artifact localization,” arXiv:2510.08789, 2025. [Online]. Available: https://arxiv.org/abs/2510.08789
[14] E. Samei et al., “Performance evaluation of computed tomography systems: Summary of AAPM task group 233,” Medical Physics, vol. 46, no. 11, Sep. 2019.
[15] J. Greffrier, Y. Barbotteau, and F. Gardavaud, “iQMetrix-CT: New software for task-based image quality assessment of phantom CT images,” Diagnostic and Interventional Imaging, vol. 103, no. 11, pp. 555–562, Nov. 2022.
[16] Qwen Team, “Qwen3.8-Max: A new bar for coding and cowork,” https://qwen.ai/blog?id=qwen3.8, Aug. 2026.
[17] E. J. Hu et al., "LoRA: Low-rank adaptation of large language models," in International Conference on Learning Representations (ICLR), 2022.
[18] B. Efron and R. J. Tibshirani, An Introduction to the Bootstrap. Chapman & Hall, 1993.
[19] S. Holm, "A simple sequentially rejective multiple test procedure," Scandinavian Journal of Statistics, vol. 6, no. 2, pp. 65–70, 1979.
[20] K. Yan, X. Wang, L. Lu, and R. M. Summers, "DeepLesion: automated mining of large-scale lesion annotations and universal lesion detection with deep learning," Journal of Medical Imaging, vol. 5, no. 03, pp. 1–11, Jul. 2018.