Manuscript Offprint

arXiv:2611.09067

WearableBridge: Task-Guided Latent Transport for Free-Living Activity Recognition

Jingjing Zou, Yixin Wang

Abstract

Wrist-worn accelerometers make activity monitoring feasible at scale, but incidental arm motion, device orientation, and shifting context blur the signal that separates activities. Calibration studies supply higher-quality references such as concurrent thigh recordings or supervised laboratory wrist sessions, but they are expensive, cover few participants, and are rarely available at deployment. How can limited reference data improve recognition for participants who wear only a wrist device? We propose WearableBridge, which holds the reference encoder and classifier fixed and learns a task-guided transport map, the bridge, that carries each wrist feature into the region the classifier associates with its activity. Reference features or the classifier's predictions indicate the destination, and a classification loss penalizes wrist features that land in the region of another activity. We instantiate WearableBridge with three bridges: Mapper regresses onto reference features, Distillation matches the classifier's class probabilities, and MeanFlow learns a one-step flow from wrist toward reference features. On 40 held-out free-living PAAWS participants, all three bridges improve macro-F1 in every training run, and the strongest, MeanFlow, raises mean macro-F1 from 35.1% to 56.0% with concurrent thigh references (Thigh2Wrist), and from 54.0% to 63.5% with group-matched laboratory wrist references (Lab2Freeliving). Fitted only on PAAWS, MeanFlow also raises macro-F1 on the CAPTURE-24 cohort from 42.8% to 54.7%. The gains replicate on selfBACK, hold across four reference encoders, and grow with temporal context. A study can therefore collect reference recordings for a calibration subset and improve wrist-only recognition for every other participant, training only a bridge of 0.13 to 2.44 million parameters while the reference encoder and classifier stay unchanged.

Code github.com/jingjingz/WearableBridge

Interactive demo jingjingz.github.io/WearableBridge

∗^{*}Correspondence to: j2zou@ucsd.edu.

1 Introduction

Wrist-worn accelerometers record activity over many days with a single device and have made population studies of more than 100,000 participants feasible [Doherty et al., 2017]. The same placement makes the signal hard to interpret: a wrist recording mixes arm gestures, changes in device orientation, transitions, and daily context with the movement that distinguishes cycling, sitting, standing, and walking. These sources of variation are strongest in free-living (FL) recordings, collected as participants follow their daily routines without scripted activities or supervision. Classifiers trained under controlled conditions therefore lose accuracy on the FL recordings that population studies collect [Gyllensten and Bonomi, 2011, Sasaki et al., 2016, Pavey et al., 2017].

Other recordings reveal activity more clearly. A thigh sensor gives a direct view of lower-body movement, and a supervised laboratory wrist session holds recording conditions steady and supplies observed labels. We call these higher-quality references, meaning that they carry more information about activity. Both are expensive at scale: a thigh recording requires a second device and participants' compliance, a laboratory session requires staff time and visits, and FL labels can require prolonged observation or video review [Sasaki et al., 2016, Potter et al., 2025]. A realistic study therefore collects references for a calibration subset and deploys wrist-only monitoring to everyone else. We ask: how can limited reference data improve wrist-only activity recognition for new participants who have no reference recording?

Two calibration designs make this question concrete, each named by the direction in which activity information transfers. In Thigh2Wrist, a wrist window and a thigh window record the same movement at the same time, so each wrist window has its own reference, an instance-level target. In Lab2Freeliving, the wrist windows come from simulated free-living (SimFL) sessions, which imitate everyday conditions, and the references are laboratory (Lab) wrist windows from a separate session. Matching by participant, activity, wrist side, and device placement gives a group-level target. In both designs, deployment uses only a ten-second FL wrist window and its recorded side.

Existing methods that draw on higher-quality references either use them at prediction time, as in sensor fusion [Ordóñez and Roggen, 2016], or train a new wrist model by feature adaptation across placements [Chang et al., 2020, Chen et al., 2019], knowledge distillation [Hinton et al., 2015, Lopez-Paz et al., 2016] into a wrist-only student, or fine-tuning on labeled wrist data. Fusion needs the reference sensor at deployment. A new wrist model replaces the classifier trained on reference recordings and fits its activity boundaries to the blurred wrist signal. We propose WearableBridge, which keeps the reference encoder and classifier fixed and learns a small map, called the bridge, that moves wrist features within the reference feature space. The bridge needs only the wrist window at deployment, and the fixed classifier keeps the activity boundaries it learned from reference recordings, in which activities are well separated.

The key observation is that a classifier trained on reference recordings defines regions of feature space associated with each activity, and those regions remain meaningful when no reference accompanies a deployed window. WearableBridge therefore trains the bridge as a task-guided transport map that carries each wrist feature into the region of its activity. During calibration, reference features or predictions indicate where wrist features should move, and a classification

Figure

Figure 1: WearableBridge overview. (a) Calibration pairs each wrist window with a higher-quality reference: a concurrent thigh window (Thigh2Wrist) or a Lab wrist window matched by participant, activity, wrist side, and device placement (Lab2Freeliving). (b) The bridge BθB_\theta (Mapper, MeanFlow, or Distillation) moves wrist features, distributed as PsP_s, toward the reference feature distribution PrP_r and is trained with a classification loss through the fixed classifier CC. (c) Deployment uses only a free-living wrist window and its recorded side.

loss through the frozen classifier penalizes wrist features that land in the region of another activity. At deployment, the fixed classifier reads the mapped FL wrist feature (Figure 1). We compare three forms of reference guidance, instantiated as three bridges: Mapper matches reference features, Distillation matches the reference classifier's class probabilities, and MeanFlow learns a one-step flow from wrist toward reference features [Geng et al., 2025, 2026].

On the Physical Activity Assessment Using Wearable Sensors (PAAWS) dataset [Potter et al., 2025], with 40 held-out FL participants and more than 1.5 million wrist windows per design, every bridge improves macro-F1 in every run of both designs. The strongest, MeanFlow, raises macro-F1 from 35.07% to 55.98% in Thigh2Wrist, closing 44% of the gap to the thigh sensor itself, and from 54.00% to 63.54% in Lab2Freeliving. Class-level results show that each reference transfers the distinctions it observes best: thigh posture separates sitting from standing, and laboratory wrist sessions separate cycling from walking. On selfBACK, MeanFlow raises macro-F1 from 25.73% to 66.74%, above the thigh sensor itself (64.42%). Fitted only on PAAWS, MeanFlow also raises macro-F1 on the CAPTURE-24 cohort from 42.75% to 54.73% without using its labels. The gains hold across four reference encoders and grow with temporal context, where MeanFlow reaches 61.70% in Thigh2Wrist and 68.90% in Lab2Freeliving.

Our contributions are:

  • A reference-reuse formulation that casts wrist recognition with limited reference data as learning a map that moves wrist features into the activity regions of a fixed classifier trained on reference recordings. It covers instance-level (Thigh2Wrist) and group-level (Lab2Freeliving) references, and a sufficiently expressive map can reproduce the predictions of any classifier trained directly on wrist features (Section 3).

  • WearableBridge, a learning objective that combines a classification loss through the frozen classifier with a reference-guidance term, instantiated as feature matching (Mapper), class-probability matching (Distillation), or a one-step flow conditioned on the wrist feature (MeanFlow).

  • Consistent gains for participants without reference recordings: every bridge improves macro-F1 on PAAWS with all four reference encoders, and the gains replicate on selfBACK and transfer to CAPTURE-24 without target labels.

References (28)