arXiv:2611.09468cs.RONov 2026

Manuscript Offprint

arXiv:2611.09468

Mechanical Interaction Sensing for Robotic Kiwifruit Handling with an Optoelectronic Soft Suction Cup

Romina Adhami, Ebrahim Shahabi, Alessio Mondini, Samuel M. Youssef, Cosimo Della Santina, Gualtiero Volpe, Barbara Mazzolai

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Romina Adhami1^{1}, Ebrahim Shahabi2^{2}, Alessio Mondini1^{1}, Samuel M. Youssef1^{1}, Cosimo Della Santina2^{2}, Gualtiero Volpe3^{3}, Barbara Mazzolai1^{1}

1^{1}Bioinspired Soft Robotics Laboratory, Istituto Italiano di Tecnologia, Genoa, Italy

2^{2}Department of Cognitive Robotics, Delft University of Technology, Delft, The Netherlands

3^{3}DIBRIS, University of Genoa, Genoa, Italy

Abstract—Robotic handling of delicate fruit benefits from compliant contact and quantitative sensing of the mechanical interaction at the end-effector. This study investigates an optoelectronic soft suction cup with a kiwifruit-specific bicomponent design for estimating interaction forces during contact with real fruit. During known-contact intervals, the optical signals accurately estimate interaction force on fruits excluded from model training: the best shallow network achieves grouped out-of-fold pooled R2=0.968±0.005R^2 = 0.968 \pm 0.005 (MAE = 0.138 N), with a median per-fruit held-out R2=0.973R^2 = 0.973 (MAE = 0.134 N). A simple monotonic mapping from the mean optical response alone achieves R2=0.925±0.005R^2 = 0.925 \pm 0.005, showing that substantial force-related information is already present in the optical response. Leave-one-collection-day-out validation remains strong (R2=0.955±0.031R^2 = 0.955 \pm 0.031), supporting robustness across acquisition sessions. As an exploratory secondary analysis, binary Soft/Firm classification from compression-test reference labels achieves moderate balanced accuracy (≈0.705\approx 0.705) under grouped held-out-fruit validation, while finer three-class grading shows limited performance.

Index Terms—Soft robotics, optoelectronic sensing, suction cup, force estimation, kiwifruit, tactile sensing.

I. INTRODUCTION

Post-harvest handling of delicate fruit must combine gentle mechanical contact with awareness of the interaction forces that develop at the interface. Overloading damages tissue; underloading yields unstable grasps. Kiwifruit is a demanding test case: the surface is curved, compliant, often irregular, and varies strongly among individual fruits.

Soft robotic end-effectors address part of this challenge by conforming to produce and distributing contact pressure [1]–[6]. Compliance alone, however, does not provide quantitative feedback on interactions. Embedding sensors in soft structures is therefore attractive, but the sensor must remain informative when the contacted object is a real fruit rather than a laboratory plate or elastomer sample.

Optical and optoelectronic sensing enables deformation measurement in compliant structures without rigid contact-

face transducers [7], while sensorized suction cups combine grasping and sensing [8].

The optoelectronic suction-cup sensing principle adopted here was previously demonstrated for estimating contact force and direction on controlled surfaces and was integrated into an underwater soft robotic arm [9]. However, that work did not evaluate the quantitative estimation of the interaction force across biologically variable fruit. Other studies have investigated tactile force sensing and fruit handling using vision-based [10] and triboelectric [11] approaches, while piezoresistive sensing has been applied to kiwifruit stiffness estimation [12]. What remains insufficiently characterized is the performance of this optoelectronic suction-cup architecture when adapted for contact with real kiwifruit, particularly its force-estimation accuracy and variability across unseen fruits and acquisition conditions. This study addresses that gap by evaluating contact-mode force estimation under fruit-grouped and leave-one-collection-day-out validation.

Building on the previously established optoelectronic sensing principle, the contributions of this study are:

  • Adaptation and attachment-force characterization of a soft suction cup for kiwifruit contact, including geometry and material screening and evaluation of a bicomponent Dragon Skin 10 body with an Ecoflex 00-10 fruit-contacting rim (Figs. 2 and 3).

  • Quantitative interaction-force estimation from optical signals collected during contact without active suction on 70 real kiwifruits, comparing simple and nonlinear models under grouped held-out-fruit validation and examining error variability across fruits, force ranges, loading/unloading phases, and acquisition days (Table II and Figs. 8 and 9).

  • Exploratory evaluation of fruit firmness classification from the same optical signals using compression-test reference labels and grouped held-out-fruit validation.

Figure

Fig. 1. Sensorized soft suction-cup design. (a) Optoelectronic sensing principle illustrating the LED–phototransistor arrangement and deformation-dependent changes in optical paths under compression and elongation. (b) Final cup construction integrating a PCB with three LED–phototransistor pairs, translucent Ecoflex 00-50 for light transmission, and white reflective Ecoflex 00-50 around the PCB, within a Dragon Skin 10 structural body and a softer Ecoflex 00-10 fruit-contacting rim (base diameter: 23 mm).

References (24)