Manuscript Offprint
arXiv:2611.07345Slide to Report: Continuous Reporting Symptom-Specific Cybersickness in VR
Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.
PURNATA SAHA, University of Texas at San Antonio, USA
RIFATUL ISLAM, Kennesaw State University, USA
QILIANG HE, University of Texas at San Antonio, USA
JOHN QUARLES, University of Texas at San Antonio, USA

Fig. 1. Study overview. Left, top: Participants (N = 52, between-subjects) were instrumented with an HP Reverb G2 Omnicapt headset (eye and head tracking), a Polar H10 chest strap for Electrocardiography (ECG), and a Shimmer Consensys unit (Galvanic Skin Response(GSR) and Photoplethysmography (PPG), worn on the wrist and finger), and operated a 3D-printed physical slider box with their dominant hand. Red outlines mark the active control in each condition: three linear potentiometers mapped to nausea, disorientation, and oculomotor discomfort in the three-slider condition (left), and the centre potentiometer alone, reporting oculomotor discomfort, in the single-slider condition (right). Left, bottom: The VR rollercoaster environment, which participants experienced for up to 20 minutes or until they chose to stop. Right: The concurrent auditory Simon task. Every 5 s the spoken word "left" or "right" was played in one ear, and participants responded with the VR controller held in their non-dominant hand according to the spatial location of the sound ignoring its semantic content. In the congruent example (top) the word "right" is played in the right ear, requiring a right-ear response (Y); in the incongruent example (bottom) the same word is played in the left ear, requiring a left-ear response (X).
Authors' Contact Information: Purnata Saha, purnata.saha@my.utsa.edu, University of Texas at San Antonio, San Antonio, Texas, USA; Rifatul Islam, rislam11@kennesaw.edu, Kennesaw State University, Kennesaw, Georgia, USA; Qiliang He, qiliang.he@utsa.edu, Psychology, University of Texas at San Antonio, San Antonio, Texas, USA; John Quarles, john.quarles@utsa.edu, University of Texas at San Antonio, San Antonio, Texas, USA.
- Manuscript submitted to ACM
Saha et al.
Cybersickness is often assessed during VR exposure through discrete overall sickness, which cannot capture specific symptoms or their changes over time. Post-exposure questionnaires such as the Simulator Sickness Questionnaire provide symptom-specific measures but cannot be collected during immersion. We investigate whether separating cybersickness into three symptom-specific dimensions—nausea, oculomotor discomfort, and disorientation—during immersion provides more informative continuous measurements. We conducted a between-subjects study with 52 participants in a VR-rollercoaster, comparing a three-slider interface with a single-slider interface. Concurrently, participants also completed an auditory Simon task to measure attention. We additionally collected multimodal set of physiological signals, including GSR, ECG, PPG, eye and head tracking. Results show that each slider correlated most strongly with its corresponding SSQ subscale, whereas the single slider correlated with all SSQ subscales. Using three sliders did not significantly affect usability, workload, or attention. We publicly release the multimodal dataset to support future cybersickness research.
Our dataset and implementation are available in our anonymized repository.
ACM Reference Format:
Purnata Saha, Rifatul Islam, Qiliang He, and John Quarles. 2018. Slide to Report: Continuous Reporting Symptom-Specific Cybersickness in VR. In Proceedings of Make sure to enter the correct conference title from your rights confirmation email (Conference acronym 'XX). ACM, New York, NY, USA, 33 pages. https://doi.org/XXXXXXX.XXXXXXX
In this study, we introduce a custom three-slider physical interface that enables users to dynamically and independently report specific cybersickness subscales - nausea, oculomotor, and disorientation, during VR immersion. Using this interface, we investigate the following two research questions:
-
RQ1: Does continuous, SSQ subscale-specific slider reporting correlate with established SSQ subscale scores?
-
RQ2: Does using three sliders instead of one make the reporting task harder, in terms of reaction time, accuracy, and perceived usability?
2 Related Work
2.1 Cybersickness assessment method
Traditional cybersickness assessment methods can be broadly categorized into post-session questionnaires and during exposure assessment [4, 18]. The most prominent of these is the SSQ, a 16-item scale rated from 0 to 3 (none to severe) that measures nausea, oculomotor, and disorientation subscales [5]. Other variations include the Virtual Reality Sickness Questionnaire (VRSQ), a 9-item derivative of the SSQ focusing on oculomotor and disorientation factors [31]; the Cybersickness Questionnaire (CSQ), which employs Likert-type ratings for VR-specific symptoms [34]. Among these, the SSQ remains the most widely used and reliable standard. However, while these tools are standardized and widely adopted, they are unable to capture symptom dynamics during immersion.
To address this limitation, continuous assessment methods collect real-time subjective ratings during VR exposure. These typically utilize single scales, such as the Misery Scale (MISC) [23], which focuses on nausea using a 0–10 scale, or the FMS (0-10), which tracks overall discomfort [29]. In traditional continuous assessments, participants are normally prompted to verbally report their discomfort scores at regular intervals of every few minutes [14].
2.2 VR Datasets with Continuous Cybersickness
Most previous studies have relied on discrete FMS assessments during immersion, collected either verbally (audio reports) or visually (on-screen prompts requiring a click), rather than continuous measurement. However, in high-tension scenarios such as rollercoaster simulations [24] or deliberately cybersickness-inducing environments [62], cybersickness symptoms can fluctuate rapidly, and continuous FMS monitoring may capture these changes more accurately than discrete sampling allows. To address this, some recent studies have adopted continuous, real-time self-report methods—such as sliders, dials, or joysticks—to capture moment-to-moment sickness severity throughout exposure. Table 1 summarizes recent studies using continuous self-report methods for cybersickness. Ryu and Kim compiled a publicly available dataset by having over 150 subjects use an external Microsoft Surface Dial to report their FMS score every 0.5 seconds during a virtual space flight [52]. Cantory et al. investigated the feasibility of continuous
Saha et al.
Table 1. Overview of Studies Utilizing Continuous Self-Report Methods for Cybersickness
| Study | Method | N | Modalities & Availability |
|---|---|---|---|
| Ryu and Kim et al (2026) [52] | Surface Dial (0–10), 2 Hz sampling rate | 150 | VR video, 6-DOF, head tracking, Public |
| Cantery et al (2025) [9] | Linear potentiometer (4 Hz sampling rate) | 18 | GSR, Optical flow. Not public |
| Plaza et al (2026) [49] | Visual UIs: bars, dials, halos (joy-stick) | 25 | GSR, eye and head tracking. Not public dataset |
| Our Study | 3 physical linear potentiometers (4 Hz sampling rate) | 52 | Eye and head tracking, GSR, ECG, PPG, Auditory Simon task (Reaction time, Accuracy). Public |
reporting by having 18 participants adjust a physical slider (a linear potentiometer) to report their sickness state during a virtual roller coaster ride [9]. Their study demonstrated a statistically significant positive correlation between the continuously reported sickness ratings and simultaneously recorded tonic skin conductance levels. Plaza et al. compared three interfaces, bars, dials, and halos, each reporting three separate symptom dimensions: nausea, disorientation, and oculomotor discomfort. Tested with 25 participants using joystick input, all three matched CSQ-VR accuracy while capturing far more temporal detail.
Our study builds on this work by introducing a custom three-slider device, with each slider mapped to an SSQ subscale (nausea, oculomotor, disorientation). Like Plaza et al., we separate symptoms into distinct dimensions, but we use physical sliders instead of joystick input, giving participants proprioceptive feedback similar to Cantory et al's sliders but we report subscale-specific values rather than one overall score. We also add a secondary auditory Simon task to measure attention during immersion, a dimension none of the prior studies test. By comparing user performance in a single-slider condition against our three-slider condition, we assess whether the added precision of multidimensional reporting can be achieved without significantly increasing cognitive load.
Finally, compared to existing datasets, our study captures a significantly more comprehensive array of multimodal data. Ryu and Kim collected only general FMS scores and virtual motion data, lacking physiological signals [52]. Cantory et al. reported one overall discomfort score paired exclusively with GSR [9]. While Plaza et al. separated the three symptom subscales, they did not collect cardiovascular metrics like ECG or PPG [49]. In contrast, our study continuously records all three SSQ subscales paired with GSR, PPG, and ECG (during both baseline and simulation), alongside eye tracking, head tracking, and Simon task performance. This unparalleled combination of physiological, behavioral, and cognitive modalities allows us to directly relate specific symptom dimensions to autonomic arousal and attentional shifts within the same dataset.
3 Experimental Design
In designing this study, we focused on two primary decisions: selecting the devices for continuous, subscale-specific reporting, and choosing an appropriate secondary task to assess attentional differences between the single- and three-slider conditions.
3.1 Interface Selection
We began by reviewing prior literature on continuous cybersickness reporting devices, which have predominantly utilized linear potentiometers [9], dials [52], or joysticks [49]. Cantory et al. tested several physical prototypes and found the linear slider to be the most intuitive and easiest to use [9]. Similarly, Plaza et al.'s usability evaluation demonstrated that a visual bar-based interface—conceptually analogous to a linear slider—achieved higher usability scores than dial-or halo-based alternatives. Based on this empirical evidence, we selected the physical linear potentiometer for our interface, as it provides clear proprioceptive feedback, is highly usable, and remains cost-effective.
3.2 Cognitive Load Assessment

Fig. 2. Illustration of the auditory Simon task, adapted from Burgoyne et al. [6]. Left: Example of a congruent trial. Right panel: example of an incongruent trial. The subject responds based on which ear received auditory input
To assess whether managing the three-slider interface imposed a higher cognitive load than the single-slider baseline, we implemented a cognitive dual-task paradigm [7]. An audio-based Simon task served as the secondary task during the VR simulation. The Simon task is a well-established behavioral measure of attentional control and cognitive conflict resolution [40]. We selected this over more demanding cognitive assessments (e.g., Stroop [11] or N-back tasks [22, 25]) to avoid overwhelming participants in an already highly stimulating environment. Furthermore, the N-back task imposes a substantial burden on working memory; consequently, poor performance can make it difficult to distinguish between generalized attentional depletion and inherent limitations in a participant's working memory [46]. Specifically, we adapted the approach of Burgoyne et al., who developed an auditory Simon task in which participants must indicate the spatial location (which ear) of an auditory stimulus while actively suppressing its conflicting semantic content [6], illustrated in Figure 2.
Participants operated the physical slider with their dominant hand and held a standard VR controller in their non-dominant hand to respond to the auditory cues. Every 5 seconds during the simulation, the spoken word "left" or "right" played in either the left or right ear. Participants (who all confirmed normal hearing) were instructed to respond solely to the sound's spatial location, completely ignoring its semantic meaning. The fixed response mapping utilized button X (left controller) or B (right controller) for left-ear sounds, and button Y (left controller) or A (right controller) for right-ear sounds. Trials were randomized between congruent (the word's meaning matched its spatial location) and incongruent (the meaning and location mismatched). Prior to the main simulation, participants completed
Saha et al.
a two-minute practice session in VR, viewing a plain grey screen to isolate the auditory task. To ensure task proficiency, any participant who made more than five errors received reiterated instructions and repeated the practice session.
4 Material
4.1 Physical Slider
The 3D-printed housing was attached to the table in front of the participant using double-sided tape. As shown in Figure 3, the three-slider housing contained three linear potentiometers mounted with a 3 cm gap between each, while the single-slider housing used a single potentiometer mounted at the center. Each slider used a uxxell B103 10 kΩ linear potentiometer (90 x 20 mm), providing a dual analog output ranging from 0 to VCC. Following the SSQ, we set the reporting scale from 0.0 to 3.0, allowing for continuous adjustments with a precision of 0.1. To provide visual feedback, we implemented corresponding visual bar sliders on a canvas within the Unity roller coaster environment, allowing participants to see their reported values change in real time as they adjusted each subscale. For the three-slider condition,

(a)
(b)
Fig. 3. The physical three-slider interface and corresponding in-VR visual feedback. (a) The physical apparatus, with the 3D-printed slider housing connected to the Arduino Mega. (b) The corresponding visual bars displayed in the VR environment, updating in real time as participants adjust each physical slider, mapped left to right to Nausea (N), Disorientation (D), and Oculomotor (O) discomfort.
we followed the SSQ subscales because the SSQ is a widely used standard for measuring symptom-specific discomfort. The three sliders represented Nausea (N), Disorientation (D), and Oculomotor (O) discomfort, positioned from left to right, respectively. In the single-slider condition, the Oculomotor slider was positioned in the center, while the other two positions were left empty. Participants used the center slider to report only their Oculomotor symptoms. An alternative design for the single-slider condition would have been to report overall discomfort using a single continuous FMS scale, comparable to Cantory et al [9]. However, since the FMS scale (0–10) differs from the SSQ subscale scale (0.0–3.0) used in our three-slider condition, this would have introduced a scale mismatch, making a direct comparison between the single-slider and three-slider conditions unfair. We therefore retained the same 0.0–3.0 scale across both conditions, using only the Oculomotor subscale in the single-slider condition. The rationale for selecting Oculomotor discomfort specifically is described in the Pilot Study section.

Fig. 4. Overview of the VR environment and study apparatus. Left: The roller coaster simulation full track layout. Right: A participant instrumented with the study's physiological sensors and subscale reporting slider: the HP Reverb G2 Omnicept headset (built-in eye and head tracking), a Polar H10 chest strap (worn under the shirt, can't be seen in the figure), a Shimmer Consensys GSR unit (GSR and PPG, worn on the wrist and finger), and the physical three-slider interface operated by the participant's dominant hand.
4.2 VR Hardware and Software
The study used the HP Reverb G2 Omnicept Edition VR headset, which provides a display resolution of 2160 × 2160 pixels per eye and a refresh rate of 90 Hz. The headset was used with its bundled motion controllers, each equipped with four built-in cameras for improved inside-out movement tracking. Audio was delivered through the headset's built-in headphones, and a Vive wireless adapter was used to enable untethered movement and ensure a smooth VR experience. The headset was connected to a Windows 10 computer with a 4.35 GHz Intel Core i7 processor, 32 GB of RAM, and an NVIDIA GeForce RTX 4080 graphics card. The virtual environment was developed in Unity 3D. To capture eye and head tracking data, including gaze position and pupil size, we used the HP Omnicept SDK at a sampling rate of 120 Hz. This built-in eye-tracking capability of the Omnicept headset allowed us to collect gaze and pupillary data without additional external sensors.
4.2.1 VR Environment. We used an open source roller coaster simulation, originally developed by Islam et al. [24]. This simulation has been widely adopted in cybersickness research for its ability to reliably induce consistent motion cues. Each loop lasted approximately 57 seconds, followed by a 10-second pause before automatically transitioning into the next loop. An initial 20-second pause preceded the first loop, allowing participants time to acclimate before the ride began. Participants remained in the simulation for up to 20 minutes, unless they chose to stop early. While participants could freely adjust their head orientation to explore the surrounding environment, the roller coaster's trajectory and velocity were fixed and could not be influenced by the participant. The simulation ran continuously unless manually interrupted by the research team, and no handheld controllers were required for navigation.
4.3 Wearable Sensors
For physiological data, we used a Shimmer Consensys GSR unit, worn on the participant's right hand. It captures GSR, PPG, and accelerometer and gyroscope data simultaneously. The GSR unit sampled at 128 Hz. ECG data were collected separately using a Polar H10 chest strap sensor, worn around the participant's chest. This sensor sampled at
Saha et al.
120 Hz. Together, these sensors allowed us to continuously record GSR, PPG, ECG, accelerometer, and gyroscope data throughout both the baseline and simulation phases of the experiment. Eye tracking data during the baseline period were collected at a sampling rate of 200 Hz using a Pupil Core eye tracker (Pupil Labs). All the modalities of collected data with the features and sampling rate is summarized in Table 4 in the appendix.
5 User study
5.1 Pilot Study
Prior to the main study, we conducted a pilot study (N = 14) employing a between-subjects design to prevent carryover effects [17, 45]. Participants were evenly divided, with seven evaluating the single-slider condition and seven evaluating the three-slider condition, both utilizing the same VR rollercoaster simulation planned for the main study. Guided by prior literature identifying nausea as a predominantly reported cybersickness symptom [20, 33], we initially selected nausea as the representative metric for the single-slider pilot condition. However, analysis of the three-slider pilot data revealed that participants adjusted the oculomotor slider more frequently and reported significantly higher severity for oculomotor symptoms compared to nausea or disorientation. Consequently, we replaced nausea with oculomotor discomfort as the targeted symptom for the single-slider condition in the main study.
We adapted the continuous slider training protocol utilized by Cantory et al. [9]. Participants viewed a desktop monitor positioned 1m away, which displayed the Nausea, Disorientation, and Oculomotor virtual sliders—identical to those used in the VR simulation—against a neutral grey background. After learning the specific physiological symptoms corresponding to each subscale, participants practiced adjusting the sliders across their 0.0 to 3.0 severity range to establish understanding of the physical-to-virtual interface mapping.
While Cantory et al. demonstrated that a five-minute session is sufficient for single-slider habituation, our pilot data indicated this was inadequate for a multi-dimensional interface. Specifically, the pilot showed inconsistent correlations between continuous in-VR reports and post-experience SSQ scores, which we attributed to participants struggling to distinguish between the three subscales. To address this, we increased the training duration from 5 to 10 minutes in the main study, ensuring participants were fully acclimated to both the symptom categorizations and the interface mechanics before beginning the simulation.
5.2 Participants
We conducted an a priori power analysis for our primary hypothesis, the correlation between continuously reported slider values and their corresponding ΔSSQ subscale scores. Using G*Power, we estimated the sample size required to detect a Pearson correlation of r = .5-.6 with α = .05 and power = .80, which indicated a minimum of 20–30 participants per condition. We used a between-subjects design, rather than within-subjects, to avoid habituation and carryover effects that can arise when participants are repeatedly exposed to the same cybersickness-inducing simulation [17]. A total of 52 participants (26 in each slider setup, , , range 18–49) were recruited. Table 2 summarizes participant demographics and Figure 5 shows the distribution of participant age, gender, and prior VR experience. The detailed study protocol is provided in Appendix D.
5.3 Data Collection Procedure
The summarized timeline of data collection is shown in Figure 6. Data collection proceeded through the following steps:
Table 2. Participant demographics (N = 52).
| Category | Group | n (%) |
|---|---|---|
| Gender | Male | 29 (55.8%) |
| Female | 21 (40.4%) | |
| Non-binary | 2 (3.8%) | |
| Prior VR exp. | Never | 15 (28.8%) |
| Rarely | 29 (55.8%) | |
| Occasionally | 8 (15.4%) | |
| Ethnicity | White / Caucasian | 15 (28.8%) |
| Hispanic / Latino | 14 (26.9%) | |
| Asian | 14 (26.9%) | |
| Multiracial/Other | 5 (9.6%) | |
| Middle Eastern | 3 (5.8%) | |
| Black/Afr. Amer. | 1 (1.9%) | |
| Corr. lenses | Yes | 29 (55.8%) |
| No | 23 (44.2%) | |
| Conditions | Motion sickness | 9 (17.3%) |
| Migraines | 5 (9.6%) |

Fig. 5. Age distribution of participants (N = 52).

Fig. 6. Timeline of the data collection procedure, grouped into three phases: preparation (steps 1–3), pre-immersion assessment (steps 4–6), and immersion & debrief (steps 7–9).
-
Informed Consent and Demographics: Participants provided informed consent and completed a demographic questionnaire.
-
Slider Practice: Participants completed a 10-minute training procedure tailored to their assigned condition (single-slider or three-slider). In the first 5 minutes, the experimenter explained which symptoms corresponded to the given subscale(s). Participants in the three-slider condition were informed about the inherent symptom overlap across the subscales; they were told that while all associated symptoms fall under each subscale (e.g., experiencing “difficulty focusing” would require increasing both the oculomotor and disorientation sliders). Participants in the single-slider condition were familiarized with Oculomotor symptoms and were instructed to adjust the slider based solely on these symptoms. They were informed that they might experience other symptoms during the VR session but were instructed not to use the slider to report symptoms that were not discussed during training. In the second 5 minutes, participants practiced mapping example scenarios to the correct slider(s) (e.g., “If you started feeling dizzy at a slight level?”), with an opportunity to ask questions before data collection began. Each slider ranged from 0.0 (no discomfort) to 3.0, increasing with severity:
– Nausea: Symptoms associated with this subscale included general discomfort, increased salivation, sweating, nausea, difficulty concentrating, stomach awareness, and burping. Participants were told to focus on the core
Saha et al.
symptoms first, particularly nausea, stomach awareness, increased salivation, and sweating. If they experienced symptoms that overlapped with another subscale, they were instructed to increase both corresponding sliders.
– Oculomotor (eyes): This subscale includes general discomfort, fatigue, headache, eyestrain, difficulty focusing, difficulty concentrating, and blurred vision. Participants were instructed to interpret these symptoms as tired or heavy eyes, difficulty focusing or concentrating, or a headache behind the eyes. The core symptoms emphasized during training were eyestrain and headache.
– Disorientation (balance): This subscale includes difficulty focusing, nausea, fullness of the head, blurred vision, dizziness (with eyes open or closed), and vertigo. Participants were trained to focus primarily on the core symptoms of dizziness, vertigo, and fullness of the head.
• Baseline Data Collection: Baseline ECG, GSR, and PPG data were recorded using Polar and Shimmer devices while participants sat at rest without any external stimuli for 2 minutes. Participants were then instructed to look at the screen, and baseline eye-tracking data were collected for an additional 2 minutes while they viewed a plain grey screen with randomly appearing white calibration spheres. Participants were told to follow the spheres with their eyes. During this period, GSR and ECG data were recorded concurrently. The rationale for collecting the baseline data and for using the controlled grey-background, sphere is described in Appendix B.
• Pre-SSQ: Participants completed the SSQ prior to VR exposure.
• Simon Task Training: Before putting on the headset, participants were instructed to press the corresponding button with their non-dominant hand based on the location of the auditory stimulus. Participants were informed that this served as their secondary task. While wearing the headset and viewing a plain grey screen displaying the task instructions, participants completed a 2-minute practice trial of the auditory Simon task. Participants who made more than five incorrect responses were provided with the instructions again and repeated the practice session.
• VR Baseline: Participants wore the VR headset for 2 minutes while viewing the same grey background like outside VR baseline with randomly appearing white calibration spheres in the virtual environment. They were instructed to visually follow the white spheres with their eyes as they appeared on the screen.
• Simulation: Participants began the roller coaster simulation, continuing until they chose to stop or until 20 minutes had elapsed. All participants concurrently performed the auditory Simon task. Of the 52 participants, 26 were assigned to the single-slider condition and 26 to the three-slider condition.
• Post-Exposure Questionnaires: Participants completed the post-exposure SSQ, the SUS to evaluate interface usability, and the NASA-TLX to assess perceived workload.
• Open-Ended Questions and Payment: Participants answered open-ended questions on whether the sliders were easy to use and which symptoms they felt most during the session. Participants were compensated $30 per hour.
5.4 Hypotheses
Based on our research questions, we test the following hypotheses:
-
H1: In the three-slider condition, each continuously reported subscale (nausea, oculomotor, and disorientation) will be significantly correlated with its corresponding SSQ subscale score.
-
H2: In the single-slider condition, the continuously reported oculomotor value will be significantly correlated with the SSQ oculomotor subscale score.
- H3: Simon reaction time and accuracy will be statistically equivalent between the three-slider and single-slider conditions
- H4: In both conditions, higher reported cybersickness will be associated with reduced attentional performance, reflected in slower reaction time and lower accuracy on the Simon task.
- H5: Perceived usability (SUS) and perceived workload (NASA-TLX) will be equivalent between the three-slider and single-slider conditions.
6 Data Analysis
This section describes the analyses conducted to address our research questions and hypotheses. We first describe data preprocessing, followed by analyses of slider usage patterns, relation with demographics, correlation between continuous subscale reports and SSQ scores (H1, H2), cognitive load between conditions (H3), the relationship between cybersickness and attention (H4) and usability (H5).
6.1 Data Preprocessing
Continuous slider values were logged throughout the simulation and synchronized with timestamps from the physiological, eye and head tracking recordings. For each participant, we computed the duration of time spent in the simulation, since participants could exit the roller coaster ride early. Nine of the 52 participants (17.3%) ended the simulation before the 20-minute time limit, including four participants in the single-slider condition and five participants in the three-slider condition. All early exits occurred between 12 and 17 minutes after the start of the simulation. Physiological signals (GSR, PPG, ECG) were cropped according to the session start and end time. We also extracted the eye and head tracking data for each participant. For the Simon task, each trial's log recorded the trial type (congruent or incongruent), response correctness, and the time taken to press the corresponding button. From these logs, we computed reaction time (RT) and accuracy for each trial, which were used in subsequent analyses of cognitive load and attention.
6.2 Slider Usage
Figure 7 shows how reported symptoms changed over the ride averaged across participants. We fitted a linear slope to each participant's reported severity over time. Every slope was reliably positive: the single oculomotor slider rose by 0.063 units per minute (, ), and in the three-slider condition, nausea rose by 0.038/min (, ), oculomotor by 0.051/min (, ), and disorientation by 0.035/min (, ). Symptoms built up at the same rate in both conditions (, ), so giving participants three sliders instead of one did not change how fast they reported getting sick. In the three-slider condition, the three subscales climbed at statistically indistinguishable rates (Friedman , ). Oculomotor discomfort ended highest ( in the final two minutes, vs. 0.51 for nausea and 0.54 for disorientation).
Table 3 summarizes how participants in each condition engaged with the reporting interface. Session duration and time-to-peak did not differ between conditions (Mann-Whitney and , respectively, Holm-corrected). A supplementary TOST equivalence analysis (; session duration , time-to-peak ). This demonstrates that the added interface complexity of the three-slider condition neither accelerated the onset of severe symptoms (time-to-peak) nor reduced participants' overall tolerance to continue the simulation (session duration). Participants in the three-slider condition made substantially more slider adjustments overall and per minute than single-slider participants ( Holm-corrected). While this is expected given that they operated three controls
Saha et al.

Fig. 7. Reported symptom severity over the ride. (a) The single oculomotor slider in the 1-slider condition. (b) All three symptom axes in the 3-slider condition. Lines show the participant mean, shaded bands ±1 SD.
rather than one, it serves as a useful engagement check confirming that participants actively used all three sliders rather than defaulting to a single one.
Table 3. Slider usage patterns by condition (Mann-Whitney U, Holm-corrected; r = rank-biserial effect size).
| Metric | 1-slider (Mdn) | 3-slider (Mdn) | p (Holm) | r |
|---|---|---|---|---|
| Session duration (min) | 18.62 | 19.68 | .553 | .10 |
| Time to reach peak (min) | 12.71 | 12.16 | .977 | .03 |
| Total slider adjustments | 440 | 1517 | < .001 | .68 |
| Adjustments / minute | 26.0 | 93.3 | < .001 | .68 |
6.3 Demographic Predictors of Symptom Severity
To examine whether demographic factors predicted cybersickness severity, we correlated each participant's continuous slider data (peak severity and area under the curve) with six pre-session variables: age, gender, prior VR experience, gaming experience, corrective lens use, and prior motion sickness susceptibility. We used Mann-Whitney U tests for two-group comparisons. For peak severity, we used the peak of the Oculomotor slider in the single-slider condition. In the three-slider condition, peak severity was defined as the highest peak across the Nausea, Disorientation, and Oculomotor sliders.
Prior motion sickness susceptibility was the only significant predictor. Participants who reported a history of motion sickness reached substantially higher peak severity () than those who did not (), a large and statistically reliable difference (; Holm corrected, ; Figure 8). This indicates that individuals generally prone to motion sickness also experience stronger cybersickness in VR, and the slider interface was sensitive enough to capture this at the subscale level. All other demographic variables like age, gender, prior VR experience, gaming experience, and corrective lens use showed no significant association with sickness severity. Female participants trended higher on nausea AUC in the three-slider condition () but this did not reach significance. Manuscript submitted to ACM

Fig. 8. Individual differences in symptom reporting. Left: peak sickness by prior motion sickness susceptibility. Middle: symptom AUC by gender across the three subscales (3-slider condition). Right: peak sickness by prior VR experience. Boxes show median and IQR; dots show individual participants.
We also verified that the two interface conditions were demographically comparable, since any imbalance could confound the between-subjects comparison. After Holm correction for multiple comparisons, no demographic feature differed significantly between the single- and three-slider groups: age (Mann-Whitney p = .096, r = .28), gender (chi-square p = .382), prior VR experience (chi-square p = .399), gaming experience (Mann-Whitney p = .983, r = .01), corrective lens use (Fisher's exact p = .088), and prior motion sickness susceptibility (Fisher's exact p = .138). These results suggest that random assignment produced well-matched groups with respect to the measured demographic and experiential characteristics. We used Mann-Whitney U tests for two-group comparisons of continuous variables, chi-square tests for categorical variables, and Fisher's exact test for binary variables where small cell counts made the chi-square approximation unreliable [32]. p-values were adjusted using the Holm procedure to account for multiple comparisons.
6.4 Correlation with SSQ (H1, H2)
To test H1, we computed Pearson correlations, for participants in the three-slider condition, between each continuously reported subscale (nausea, oculomotor, disorientation) and its corresponding SSQ subscale score, computed as the change from pre- to post-exposure ( SSQ subscale). For each participant, we used the area under curve (AUC) of continuously reported value for each subscale across the full duration of the simulation as the summary statistic of interest [56]. As we can see in the Figure 9, Each slider correlated most strongly with its own matched subscale: nausea (r = .64, 95% CI [.34, .82], p = .003), oculomotor (r = .59, 95% CI [.26, .80], p = .008, Holm corrected), and disorientation (r = .48, 95% CI [.11, .73], p = .03; Holm corrected). Separation was weaker between nausea and disorientation – the nausea slider also had a strong correlation with disorientation (r = .54, 95% CI [.19, .77], p = .017, Holm corrected). Three scatter plots on the left show slider area-under-curve against change in SSQ score for the nausea, oculomotor, and disorientation subscales. Each shows a positive linear relationship with a fitted regression line and shaded confidence band. According to H2, the single slider condition should be strongly correlated with the oculomotor since we told the participants to change that slider based on the oculomotor symptoms only. However, the slider correlated strongly with each subscale (r = .68-.76, all p < .01; Holm corrected; Figure 10). Breaking the SSQ into its 16 individual symptoms explains why (Figure 10): the slider was closely correlated with general discomfort- which is an overlapped symptoms of Nausea and Oculomotor. While headache, an oculomotor symptom, also correlated with the slider, distinctly oculomotor
Saha et al.

3-slider condition

Fig. 9. Correlation between continuously reported slider values and SSQ subscale changes in the three-slider condition. Left: Scatter plots showing the relationship between each subscale's slider area-under-curve (AUC) and its corresponding ΔSSQ subscale score. Right: Correlation matrix between all three sliders AUC and all ΔSSQ subscales (nausea, oculomotor, disorientation) and total score, with matching diagonal pairs outlined. (supports H1). Asterisks indicate significance: *p < .05, **p < .01 (Holm corrected).
items — difficulty focusing, eye strain, and blurred vision — did not reach significance. The single slider therefore captured general discomfort rather than oculomotor discomfort specifically, and we reject H2.
Since total AUC may still be partly influenced by session duration, which could affect the observed correlation coefficients, we repeated all H1 and H2 correlation analyses using AUC normalized by session duration (AUC per minute) as shown in the Figure 11. In the three-slider condition, each slider remained most strongly associated with its matched ΔSSQ subscale (nausea r = .64, oculomotor r = .56, disorientation r = .50). In the single-slider condition, the slider again correlated significantly with all four ΔSSQ measures (r = .57–.67), most strongly with ΔDisorientation rather than the instructed ΔOculomotor subscale. After accounting for session duration, no off-diagonal pair were significant. This makes the separation more clear and further supports H1. However, H2 remains unchanged: correlating significantly with all the subscales of SSQ.
6.5 Cognitive Load (H3)
To test H3, we compared secondary-task (Simon task) performance between the single-slider and three-slider conditions. For each participant, we computed mean reaction time (RT) and accuracy, separately for congruent and incongruent trials. Splitting reaction time by interface (Figure 12) showed the one-slider and three-slider conditions tracking each other closely at both trial types. Comparing the two conditions on each Simon measure with Mann-Whitney U tests revealed no significant differences, with small effect sizes throughout (reported as rank-biserial r): accuracy (p = .97, Manuscript submitted to ACM


Fig. 10. Correlation between the continuously reported oculomotor slider value and SSQ subscale changes in the single-slider condition. Left: Scatter plots showing the relationship between the slider area-under-curve (AUC) and Nausea, Oculomotor, Disorientation, and Total SSQ scores. Middle: Correlation matrix with Slider AUC and SSQ subscales and Right: Correlation of single slider AUC with individual SSQ items. Asterisks indicate significance: , . (Holm corrected)

1-slider condition

Fig. 11. Correlations between exposure-normalized slider values (AUC per minute) and SSQ subscale changes. Left: three-slider condition, with matched slider–subscale pairs outlined. Right: single-slider condition. Asterisks indicate significance after Holm correction ( , ).
, congruent reaction time , incongruent reaction time , and the congruency effect ; Holm-corrected; Figure 12). To test this formally while separating the effect of congruency from the effect of the interface, we fit an ordinary least-squares (OLS) regression predicting reaction time from congruency,
Saha et al.

Fig. 12. Reaction time by interface and trial type (± SE). The one-slider and three-slider conditions track each other closely.
interface group, and their interaction. Because each participant contributed two data points (one per trial type), these observations are not independent, so we used standard errors clustered by participant [8]:
where Congruency is 0 for congruent and 1 for incongruent trials, and Group is 0 for the 1-slider and 1 for the 3-slider interface.
-
(Congruency) captures the Simon interference effect: reaction time was significantly longer on incongruent than congruent trials (,ms, 95% CI [0.030, 0.083], ), confirming the task engaged attention as intended.
-
(Group) captures the overall difference between interfaces: participants using the 3-slider interface were about 35,ms slower on average, but this difference was not significant (, 95% CI [-0.096, 0.166], ).
-
(Congruency Group) tests whether the congruency slowdown is larger under the 3-slider interface, which would indicate the extra sliders consume attention. The slowdown was about 25,ms larger in the 3-slider group, but this interaction was not significant (, 95% CI [-0.034, 0.083], ).
To determine whether these small differences constituted practical equivalence, we conducted a TOST analysis using an equivalence bound of . We defined equivalence bounds of , corresponding to Cohen's conventional benchmark for a medium standardized mean difference [12], as our equivalence bound. All four TOST -values failed to reach significance ( ranging from .106 to .227), yielding an inconclusive verdict. Taken together, the uniformly small observed effect sizes (rank biserial ) provide no evidence that the three-slider interface increased attentional or cognitive load. However, the equivalence test was inconclusive at the conventional equivalence bound, indicating that a larger sample is needed to establish true equivalence between the two interfaces. Therefore, we consider H3 partially supported: while the three-slider interface did not show evidence of increased cognitive load, we cannot conclusively claim that the two interfaces are equivalent.
6.6 Relationship Between Cybersickness and Attention (H4)

Fig. 13. Correlation between continuously reported cybersickness and Simon task performance. Left: Three-slider condition (N = 26). Right: Single-slider condition (N = 26). *p < .05.
To test H4, we examined the relationship between reported cybersickness severity and concurrent Simon task performance. Because the single-slider interface collected only oculomotor ratings, whereas the three-slider interface collected nausea, oculomotor, and disorientation ratings, we analyzed the two conditions separately. For each participant we computed summary cybersickness metrics (area under the curve per minute, AUC/min, for each available subscale) and summary Simon performance (accuracy, mean RT for congruent trials, and mean RT for incongruent trials) across the full session, and correlated these across participants. This is a between-person analysis: it tests whether participants who reported more sickness performed worse overall.
In the three-slider condition, nausea AUC/min was positively associated with mean RT on congruent trials (r = .44, 95% CI [.11, .70], p = .026, Holm-corrected, N = 26; Figure 13). Thus, participants who experienced greater cumulative nausea tended to respond more slowly on congruent Simon trials. RT was also positively correlated with the other cybersickness subscales as expected, while accuracy was generally negatively correlated with sickness severity; however, none of these additional correlation reached statistical significance.
In the single-slider condition, oculomotor AUC/min was positively associated with mean RT for both congruent trials (r = .44, 95% CI [.11, .70], p = .029, Holm-corrected) and incongruent trials (r = .46, 95% CI [.14, .72], p = .020, Holm-corrected; N = 26; Figure 13). Peak oculomotor severity showed similar positive, but non-significant, associations with RT for congruent (r = .33) and incongruent trials (r = .32). Neither peak oculomotor severity nor oculomotor AUC/min was significantly associated with accuracy.
This correlation analysis tests whether participants who reported more sickness performed worse overall. To consider the moment-to-moment detail, we also analysed performance at the level of individual Simon trials. We therefore fit a linear mixed-effects model [58], with trials nested within participants. For each trial, we assigned the average slider sickness rating from the 30-second window in which the trial occurred, and examined whether sickness severity predicted reaction time. The model included a random intercept for each participant to account for differences in
Saha et al.
participants' baseline performance, and trial congruency as a fixed effect to control for the usual Simon interference effect. For trial i from participant j:
where is the window-mean slider rating (0.0–3.0) and is 1 for congruent and 0 for incongruent trials. The term is the participant-specific random intercept, which captures stable differences in each participant's baseline response speed, and is the trial-level residual.
Accuracy was analysed in the same way using a binomial mixed model with a logit link. This approach kept all approximately 5,200–5,300 trials in each panel as separate observations, rather than averaging them across participants. We also included a severity congruency interaction to test whether sickness severity had a different effect on performance during congruent versus incongruent trials.
The coefficient is the change in reaction time per one-point rise on the 0–3 slider, in seconds, where positive values indicate slower responses. All four setup showed slower responses at higher reported severity (Figure 14). The strongest relation was found for disorientation in the three-slider condition ( s per severity point, 95% CI [0.048, 0.124], , Holm-corrected), followed by oculomotor discomfort in the three-slider condition ( s, 95% CI [0.009, 0.062], , Holm-corrected). Single-slider oculomotor ( s, , Holm-corrected) and three-slider nausea ( s, , Holm-corrected) were not significant. For accuracy, no subscale was significantly associated with severity after Holm correction. The severity congruency interaction was insignificant for all the slider setup indicating that severity didn't affect congruent and incongruent trials differently.
Trial-level severity effect on concurrent Simon-task performance

● worse performance at higher severity blue better performance at higher severity * ** (Holm-corrected)
Fig. 14. Fixed-effect estimates from the trial-level mixed models relating window-mean cybersickness severity to concurrent Simon-task performance (random intercept per participant, congruency controlled; 5,200–5,300 trials from 26 participants per panel). Points show the change in performance per one-point increase in reported severity; bars are 95% confidence intervals. Red indicates an effect in the direction of impaired performance. ,
Taken together, these findings partially support H4. We hypothesized that greater symptom severity would be associated with both slower reaction times and lower accuracy. The reaction-time component was supported but no Manuscript submitted to ACM accuracy association survived correction in either analysis. We therefore conclude that reported cybersickness was reliably associated with slower responding, but not with reduced accuracy, on the concurrent Simon task.
6.7 Usability (H5)
To test H5, we compared the ease of use of the two reporting interfaces. Participants took two standard self-report questionnaires administered immediately after the session: SUS and the NASA-TLX. SUS consists of ten items rated on a 1–5 scale, alternating between positive (e.g., “I found the system easy to use”) and negative (e.g., “I found this system unnecessarily complex”) statements [37]. Responses are converted to a composite score from 0 to 100, where scores above 68 are generally considered acceptable. We computed a SUS score for each participant and compared the two conditions using a Mann-Whitney U test. Both conditions were rated as usable and comfortable to operate. The three-slider group scored (, ) and the single-slider group scored (, ), both well above the acceptability threshold. The difference was negligible (, , ). Because a non-significant test does not by itself demonstrate that the two interfaces are equally usable, we followed

Fig. 15. Usability outcomes by condition. Left: SUS scores (boxes show median and IQR; dots show individual participants; dashed line marks the SUS acceptability threshold of 68). Right: NASA-TLX subscale means ( SE). No comparison reached significance, and the two interfaces were statistically equivalent on the SUS.
up with a TOST equivalence analysis, using an equivalence bound of Cohen's [35]. The SUS scores were statistically equivalent (): the observed difference () fell well within the equivalence bounds, allowing us to positively conclude that the two interfaces are equally usable, directly supporting H5.
NASA-TLX measures six dimensions of perceived workload — mental demand, physical demand, temporal demand, performance, effort, and frustration — each rated on a 1–10 scale [21, 51]. We compared each subscale between conditions using Mann-Whitney U tests (Figure 15). No subscale differed significantly (all , all ). The three-slider condition trended toward lower workload on mental demand, temporal demand, and frustration, though these differences did not reach significance. A follow-up TOST at the bound found the two conditions statistically equivalent on perceived performance () but was inconclusive for the remaining subscales, so we do not claim equivalence for those. Together, these results partially support H5: the two interfaces were comparable in usability, showing statistically equivalent SUS scores and equivalent perceived performance on the NASA-TLX, with no evidence that the three-slider interface increased workload on any dimension.
Saha et al.
6.8 Correlation with Different Modalities
To support an exploratory analysis of modality–symptom relationships, we extracted a common set of windowed features from all five recorded data streams: eye tracking, head tracking, ECG, PPG, and GSR. Each stream was first cleaned and filtered independently, then summarized within a sliding 30 s window. A detailed description of the signal processing and feature extraction pipeline for each modality is provided in Appendix C. Figure 17 shows a representative 30 s window of processed multimodal data from a single participant in Appendix F.
Because each participant contributed many windows, correlating pooled windows would conflate between-participant differences with the within-person relationship of interest, and would treat non-independent observations as independent, inflating significance. We therefore used repeated-measures correlation (rmcorr) [1], which estimates a single common slope across participants while allowing each participant their own intercept. Before correlation, each physiological feature was expressed relative to the participant's pre-exposure VR baseline. VR baseline was used because we wanted to take into account how much it changes from non-stimulating VR environment since we are considering cybersickness. As a preliminary check, we also tested whether any baseline feature differed between the two interface conditions with a Mann–Whitney U test. After Holm correction, no feature showed a significant difference (all ), indicating that the two groups did not differ before the simulation started.
For every physiological and eye-tracking feature, we computed a participant-specific baseline mean and standard deviation using their two-minute VR baseline [41, 54]. Each simulation-window feature was then converted into a within-participant z-score against this baseline. Head-tracking features were excluded, as no VR-baseline equivalent exists to compute a reference.
We report the within-person correlation for each feature–subscale pair, correcting -values for multiple comparisons with the Benjamini–Hochberg false discovery rate (FDR) within each subscale and treating as significant [2]. In the single-slider condition, each feature was related to the oculomotor rating; in the three-slider condition, each feature was related separately to the nausea, oculomotor, and disorientation ratings (Figure 16).
Pupil diameter showed the strongest and most stable association: it correlated positively with all four symptom measures (single-slider oculomotor ; three-slider nausea .27, oculomotor .33, disorientation .24; all ), indicating that participants' pupils dilated as their reported sickness rose. Skin conductance level and spontaneous skin-conductance responses (SCR rate and count) increased with reported symptoms across conditions (e.g., SCL for single-slider oculomotor; SCR count and rate for three-slider oculomotor; all ), further supporting the use of physiological measures as indicators of cybersickness severity [3].
7 Discussion
7.1 Dataset novelty
In this study, we introduced a custom three-slider physical interface designed to capture continuous, symptom-specific cybersickness dimensions (nausea, oculomotor discomfort, and disorientation) during VR exposure. While recent research has shifted toward continuous rather than discrete reporting—demonstrating that continuous methods can capture sickness fluctuations with greater precision [9]. Most of these methods have relied on a single scale to measure overall discomfort, such as the FMS scale [9, 52]. Plaza et al. recently evaluated a three-scale approach (nausea, disorientation, and oculomotor discomfort) similar to ours. However, their work primarily focused on comparing different virtual UIs and they use a single joystick rather than independent physical controls.[49]. In contrast, our study specifically validates whether continuous reporting across three physical sliders is consistent with established SSQ
Within-person physiological correlates: before vs. after baseline correction
- significant at FDR q < .05

Fig. 16. Within-person (rmcorr) correlations between physiological features and reported symptom severity, shown before and after baseline correction, for each condition and subscale. Hollow points show the correlation before baseline correction and filled points after; a connecting line marks how much the correction shifted each estimate (for most features the two coincide). (*) marks means significant at FDR correction
subscales, and explicitly investigates whether managing three sliders instead of one adversely affects user attention and cognitive load.
Public cybersickness datasets typically provide a single overall sickness measure. To our knowledge, ours is the first to release independent continuous ratings of nausea, oculomotor discomfort, and disorientation, together with eye tracking, head tracking, GSR, ECG, PPG, and concurrent Simon-task reaction time and accuracy. This combination enables research questions that are difficult to examine using existing datasets, such as identifying which physiological signals are most strongly associated with specific cybersickness symptoms rather than cybersickness treated as a single overall construct. The dataset also provides two additional features that may support future research. First, our sample covers a relatively broad age range (18–49 years, , ), although it remains skewed toward a student demographic since the majority of participants were recruited from a university population. We
Saha et al.
also examine demographic and individual-difference factors, including age, gender, prior VR and gaming experience, corrective lens use, and previous motion-sickness history, and report their relationships with cybersickness severity. This information can support research into individual differences in cybersickness susceptibility rather than focusing only on physiological manifestations of sickness. Second, we provide synchronized baseline recordings collected before immersion for every modality. These include both an outside-VR seated baseline and a VR-baseline. These recordings allow future researchers to examine within-participant changes and physiological reactivity relative to each individual's baseline, rather than relying solely on absolute measurements or comparisons across participants. None of the three prior datasets listed in provides both of these baseline conditions, making them an additional feature of our dataset.
7.2 Three sliders correlates with corresponding symptoms
Supporting H1, every slider in the three-slider condition correlated most strongly with its own matched SSQ subscale: nausea (), oculomotor (), and disorientation (), forming a clear diagonal pattern in the correlation matrix (Figure 9). We used the AUC of each slider trace rather than peak severity, because AUC reflects the accumulated symptom burden across the entire exposure, whereas peak captures only a single moment. This suggests participants could track three symptom dimensions during immersive VR that align with their intended SSQ subscales. Since we considered SSQ as for dividing the subscale and as post session baseline questionnaire to compare, SSQ itself has overlapping symptoms. For example, While calculating Disorientation it also include nausea (which is major symptom of nausea subscale) or difficulty focusing which is also included in oculomotor symptom. Therefore nausea slider also showing a strong correlation with the disorientation SSQ score (). Part of this overlap appears attributable when we consider exposure duration of participants. When we divide each slider's AUC by session length, the link between the nausea slider and Disorientation is no longer significant.
Conversely, we reject H2, which hypothesized that the single slider would specifically track oculomotor discomfort. In the single-slider condition, continuous reports correlated strongly with all post-exposure SSQ subscales: Nausea (), Oculomotor (), and Disorientation (). This pattern holds when we account for exposure time: with AUC per minute, the single slider still correlates significantly with every subscale (), and still most strongly with disorientation rather than oculomotor. An item-level analysis of the 16 individual SSQ symptoms with AUC of slider revealed that the single slider correlated most highly with general discomfort, fullness of the head, headache, and dizziness. While headache is a specifically targeted oculomotor symptom, general discomfort contributes to both the oculomotor and nausea subscales, and fullness of the head and dizziness are primary indicators of disorientation. Participants in the single-slider condition were familiarized with oculomotor symptoms and instructed to adjust the slider solely in response to those specific cues. During the post-session open-ended questionnaire, we asked participants whether they experienced symptoms beyond the explained oculomotor ones and if they had adjusted the slider for those uninstructed symptoms. The feedback revealed that a vast majority (86%) experienced concurrent symptoms, such as nausea and dizziness. Notably, 22% of participants explicitly stated that they increased the slider in response to these additional symptoms instead of only oculomotor. Thus, these participants effectively used the slider as a measure of overall discomfort rather than solely oculomotor symptoms, which likely contributed to the strong correlations observed across the SSQ subscales.
7.3 Does a multi-slider interface add usability issues or cognitive load?
We hypothesized that attentional demands would be equivalent between the single-slider and three-slider conditions because the Simon task is designed to impose minimal working memory load. Furthermore, the two tasks utilize distinct Manuscript submitted to ACM perceptual modalities and response mechanisms, minimizing cognitive interference: the Simon task relies on auditory input and discrete button presses, whereas slider reporting requires interoceptive monitoring and continuous positional adjustments. Crucially, scaling from one to three sliders merely multiplies an existing activity rather than introducing a qualitatively new attentional demand. Because participants received extensive pre-study training to intuitively map their symptoms to the sliders, tracking three concurrent symptoms did not impose a significantly higher cognitive load than tracking a single symptom [59].
The secondary Simon task analysis provides evidence that the three-slider interface did not significantly affect concurrent attention. Reaction times were slower on incongruent than congruent trials in both conditions ( ms, ), confirming that the task produced the expected congruency effect and successfully engaged attention. Overall reaction time did not differ significantly between the single- and three-slider conditions ( ms, ). Accuracy also did not differ significantly between conditions. The potential reason is the simplicity of the Simon task, coupled with pre-study training, allowed participants to maintain high accuracy across all trial types and interface conditions. Although the RT equivalence test was inconclusive, the relatively small Mann–Whitney effect size (subsection 6.5) suggests that any difference in reaction time between conditions was likely negligible. Overall, the findings from cognitive load suggest that managing three sliders did not increase perceived difficulty, substantially alter behavior, or impair performance on the concurrent attention task compared with managing a single slider.
Subjective usability (SUS) scores for the three-slider () and single-slider () conditions both exceeded acceptability thresholds and were statistically equivalent, supporting H5. NASA-TLX ratings also showed no significant differences across dimensions, with perceived performance specifically confirmed to be statistically equivalent.
7.4 Relation of attention with cybersickness
Our dual-task design let us test whether cybersickness was linked to attention (H4). We expected that people who felt sicker would respond more slowly. We tested this in two ways. The correlation analysis asks whether participants who reported more sickness across the whole session performed worse across the whole session. The trial-level model asks whether performance tracked sickness as it changed during the session.
In the between-person analysis, the one-slider condition showed that greater cybersickness was significantly associated with slower reaction times for both congruent and incongruent trials. However, in the three-slider condition, only nausea severity exhibited a significant correlation with RT in congruent trials; the other specific symptoms were not significantly linked to performance differences. This discrepancy is likely because participants in the one-slider condition treated the single input as a measure of 'overall' cybersickness—a behavior supported by both their questionnaire responses and the data shown in Figure 10.
The trial-level analysis pointed to different symptoms. Disorientation had the strongest link with reaction time, followed by oculomotor discomfort in the same condition. Participants who reported higher nausea overall in the three-slider condition responded more slowly. At the trial level, however, trials occurring in windows with higher reported disorientation had significantly slower responses, whereas the association with nausea was not significant. One explanation is that disorientation is triggered by specific moments of visual–vestibular conflict, such as loops and drops, whereas nausea builds up more gradually over the exposure [50]. A whole-session summary captures accumulated nausea well, while the 30-second windows are better suited to a symptom that fluctuates. The single-slider condition behaved like nausea in the trial-level analysis. The association with reaction time was positive but not significant, meaning the moment-to-moment changes were not strong enough to detect reliably. Future work could test different window lengths to find the timescale at which each symptom relates most closely to performance. Including time in
Saha et al.
the session as a predictor would also help separate symptom-driven slowing from general fatigue. Accuracy showed no reliable relation with sickness in either analysis. This is likely because the Simon task was simple and participants were trained beforehand. Sickness slowed congruent and incongruent trials by a similar amount, and the severity × congruency interaction was not significant in any panel. This suggests cybersickness reduces the attention available for the task in general, rather than specifically weakening the ability to suppress a conflicting response.
7.5 Physiological Correlates of Cybersickness
Across conditions, pupil diameter and electrodermal activity showed the most consistent positive associations with cybersickness ratings [3, 26]. Because these were within-participant correlations, they indicate that changes in a person's own physiology covaried with changes in their own symptoms over time.
Pupil diameter increased across all three symptom dimensions. This pattern is consistent with increased autonomic arousal and cognitive demand during cybersickness [27]. Similarly, the positive association between GSR and oculomotor symptoms likely reflects general arousal rather than visual strain specifically. The strongest association was between skin conductance level and the single-slider oculomotor rating (). However, our SSQ analysis suggests that participants used the single slider as a measure of general discomfort rather than oculomotor strain alone. Thus, this correlation likely reflects the relationship between overall sickness severity and sympathetic arousal, for which electrodermal activity is a well-established indicator [42]. The GSR–Nausea association is more directly compatible with motion-sickness physiology, as increased tonic skin conductance and phasic electrodermal responses have been reported during nausea [42].
Baseline normalization most affected electrodermal features. Several GSR measures changed from weak or negative uncorrected relation to significant positive correlations after baseline z-scoring. This is plausible because GSR shows substantial between-person differences in tonic level and may drift over an experimental session [19]. Baseline z-scoring therefore emphasizes each participant's change relative to their own pre-exposure VR state. Baselines can be established in several ways, including subtracting a resting value, dividing by it, or standardizing each participant's series relative to their own baseline mean and variance [16, 41]. We adopted per-participant z-scoring, which expresses each simulation-window feature in standard-deviation units relative to that participant's two-minute VR baseline. This reduces both additive baseline offsets and scale differences between participants; for example, some individuals show a wider physiological range than others [41]. We screened many features against each subscale, we controlled the false discovery rate with the Benjamini–Hochberg procedure [2], applied within each subscale. This procedure controls the expected proportion of false discoveries among results declared significant, providing a useful balance between false-positive control and statistical power for exploratory feature screens [2].
8 Limitations and Future Directions
Several limitations should be considered when interpreting our findings. First, although our sample size provided sufficient power for the main correlation hypotheses (H1, H2) and the significance tests between conditions, it was underpowered for the equivalence hypotheses (H3, H5) at the conventional equivalence bound of (achieved power = 31%). This limited our ability to draw strong conclusions about equivalence and may explain why reaction time and NASA TLX did not meet the equivalence criterion. Second, some SSQ symptoms belong to more than one subscale, making it difficult to separate nausea, oculomotor discomfort, and disorientation cleanly. This overlap may have influenced the relationships between the slider ratings and the three SSQ subscales. Third, the single-slider and three-slider conditions differed not only in the number of available controls but also in the symptom information provided during training. Participants in the single-slider condition were trained only on oculomotor symptoms and were instructed to use the slider only for those symptoms, whereas participants in the three-slider condition received training on all three symptom categories, including their potential overlap. Consequently, the rejection of H2 cannot be interpreted as a test of interface dimensionality alone, as the two conditions also differed in instructional content. The strong associations between the single slider and all three SSQ subscales may partly reflect participants' experience of symptoms beyond those specified during training and their use of the single available slider to report these symptoms. Finally, the slider itself may have served as a static visual reference and potentially mitigated cybersickness [10]. This potential mitigating effect was not explicitly considered in the study and may have influenced symptom severity across conditions.
Our multimodal dataset provides several opportunities for future research. Because we collected physiological data before VR exposure, including ECG, GSR, PPG, and eye tracking, future work can investigate whether baseline physiological characteristics can predict which cybersickness symptoms a person may experience during VR. The availability of both outside-VR and in-VR baseline measurements also allows future studies to examine the physiological changes caused by entering the virtual environment and whether these early changes can predict later cybersickness. Time-series prediction methods could further be used to develop personalized models that detect symptoms early and potentially support preventive interventions [15, 38, 61]. The continuous symptom-specific measurements can also be used to evaluate targeted cybersickness interventions by examining whether a particular intervention reduces one symptom more effectively than another. Future work on this data could look further into how specific symptoms affect attention in VR, for example by separating each participant's average severity from their moment-to-moment change, or by accounting for time spent in the simulation. Finally, although using three sliders did not show a significant increase in cognitive load compared with one slider, future studies should investigate the maximum number of symptoms that users can reliably report simultaneously and determine how many input dimensions can be supported before the interface begins to interfere with attention or task performance.
9 Conclusion
This study introduced a novel three-slider interface for the continuous, multidimensional reporting of cybersickness in virtual reality. By moving beyond single-metric discomfort scores, this tool allows researchers and developers to track the onset and trajectory of three symptoms—nausea, oculomotor, and disorientation. For the broader VR community, this granular level of symptom tracking is a critical stepping stone toward developing adaptive environments that can automatically adjust rendering, locomotion, or field-of-view in real time to mitigate specific discomforts before they escalate. By validating this multidimensional reporting tool and openly sharing our comprehensive multimodal dataset, this work establishes a robust methodological foundation for the future of real-time cybersickness prediction and targeted symptom mitigation.
10 Acknowledgments
This study was reviewed and approved by the university's Institutional Review Board (University of Texas at San Antonio IRB, Protocol #14-095, approved 11 January 2024; contact irb@utsa.edu) before any data collection began. All participants gave written informed consent before the session and were explicitly told that the VR exposure could induce mild to severe cybersickness symptoms. They were informed that they could withdraw at any time, for any reason, without penalty, and could stop the simulation whenever they wished. They were instructed to notify the research team immediately if they experienced severe discomfort. Participants were compensated $30 per hour.
Saha et al.
References
[1] Jonathan Z. Bakdash and Laura R. Marusich. 2017. Repeated measures correlation. Frontiers in Psychology 8 (2017), 456. doi:10.3389/fpsyg.2017.00456
[2] Yoav Benjamini and Yosef Hochberg. 1995. Controlling the False Discovery Rate: A Practical and Powerful Approach to Multiple Testing. Journal of the Royal Statistical Society: Series B (Methodological) 57, 1 (1995), 289–300. doi:10.1111/j.2517-6161.1995.tb02031.x
[3] Phillip Brown, Andrew T Hendrickson, Pieter Spronck, and Wendy Powell. 2026. Physiological Markers of Cybersickness in Virtual Reality: Skin Conductance Correlates with Momentary Cybersickness Across Time. Journal of Medical Extended Reality 3 (2026), 29941520251415449.
[4] Phillip Brown and Wendy Powell. 2021. Pre-exposure cybersickness assessment within a chronic pain population in virtual reality. Frontiers in Virtual Reality 2 (2021), 672245.
[5] P Brown, P Spronck, and W Powell. 2022. The simulator sickness questionnaire, and the erroneous zero baseline assumption. Frontiers in Virtual Reality, 3.
[6] Alexander P Burgoyne, Dolly T Seeburger, and Randall W Engle. 2024. Modality matters: Three auditory conflict tasks to measure individual differences in attention control. Behavior Research Methods 56, 6 (2024), 5959–5985.
[7] Tom Burke and Brendan Rooney. 2021. Multi-modal dual-task measurement: A new virtual reality for assessment. Frontiers in Psychology 11 (2021), 635413.
[8] A Colin Cameron and Douglas L Miller. 2015. A practitioner's guide to cluster-robust inference. Journal of Human Resources 50, 2 (2015), 317–372.
[9] Ville Cantory, Jangyoon Kim, Courtney Hutton Pospick, Koorosh Vaziri, Evan Suma Rosenberg, and Victoria Interrante. 2025. A Feasibility and Impact Investigation of Continuous Subjective Cybersickness Feedback Reporting. In Proceedings of the 2025 31st ACM Symposium on Virtual Reality Software and Technology. 1–10.
[10] Zekun Cao, Jason Jerald, and Regis Kopper. 2018. Visually-induced motion sickness reduction via static and dynamic rest frames. In 2018 IEEE conference on virtual reality and 3D user interfaces (VR). IEEE, 105–112.
[11] Ryan S Chung, Jonathon Cavaleri, Shivani Sundaram, Zachary D Gilbert, Roberto Martin Del Campo-Vera, Andrea Leonor, Austin M Tang, Kuang-Hsuan Chen, Rinu Sebastian, Arthur Shao, et al. 2024. Understanding the human conflict processing network: A review of the literature on direct neural recordings during performance of a modified stroop task. Neuroscience Research 206 (2024), 1–19.
[12] Jacob Cohen. 2013. Statistical power analysis for the behavioral sciences. routledge.
[13] Alexandre Coste, Geoffrey Millour, and Christophe Hausswirth. 2025. A comparative study between ECG-and PPG-based heart rate sensors for heart rate variability measurements: Influence of body position, duration, sex, and age. Sensors 25, 18 (2025), 5745.
[14] Simon Davis, Keith Nesbitt, and Eugene Nalivaiko. 2014. A systematic review of cybersickness. In Proceedings of the 2014 conference on interactive entertainment. 1–9.
[15] Mark S Dennison, A Zachary Wisti, and Michael D'Zmura. 2016. Use of physiological signals to predict cybersickness. Displays 44 (2016), 42–52.
[16] Arindam Dey, Hao Chen, Tareq Zaman, and Mark Billinghurst. 2018. Virtual Reality Experiments with Physiological Measures. Journal of Visualized Experiments 137 (2018). doi:10.3791/58471
[17] Taylor A Doty, Jonathan W Kelly, Stephen B Gilbert, and Michael C Dorneich. 2024. Cybersickness abatement from repeated exposure to VR with reduced discomfort. IEEE transactions on visualization and computer graphics 31, 9 (2024), 5910–5921.
[18] María Fernández-Cañas, Rosa María Ortiz-Gutiérrez, Patricia Martin-Casas, Cecilia Estrada-Barranco, Selena Marcos-Antón, Aitor Blázquez-Fernández, Sofia Laguarta-Val, Carmen Jiménez-Antona, and Roberto Cano-de-la Cuerda. 2025. Cybersickness Evaluation in Immersive Virtual Environments: A Systematic Review with Implications for Neurological Rehabilitation. Journal of Clinical Medicine 15, 1 (2025), 46.
[19] Society for Psychophysiological Research Ad Hoc Committee on Electrodermal Measures, Wolfram Boucein, Don C Fowles, Sverre Grimnes, Gershon Ben-Shakhar, Walton T Roth, Michael E Dawson, and Diane L Filion. 2012. Publication recommendations for electrodermal measurements. Psychophysiology 49, 8 (2012), 1017–1034.
[20] Luis Eduardo Garrido, Maite Frías-Hiciano, Mariano Moreno-Jiménez, Gabriella Nicole Cruz, Zoilo Emilio García-Batista, Kiero Guerra-Peña, and Leonardo Adrián Medrano. 2022. Focusing on cybersickness: pervasiveness, latent trajectories, susceptibility, and effects on the virtual reality experience. Virtual reality 26, 4 (2022), 1347–1371.
[21] Peter Hoonakker, Pascale Carayon, Ayse P Gurses, Roger Brown, Adjihaporn Khunlertkit, Kerry McGuire, and James M Walker. 2011. Measuring workload of ICU nurses with a questionnaire survey: the NASA Task Load Index (TLX). IIE transactions on healthcare systems engineering 1, 2 (2011), 131–143.
[22] Shaojia Huang, Caini Chen, Yuanqin Mo, Yihan Zhao, Yuge Zhu, Kangli Dong, and Tao Xu. 2025. Exploring the n-back task: insights, applications, and future directions. Frontiers in Human Neuroscience 19 (2025), 1721330.
[23] Tugrul Irmak, Daan M Pool, and Riender Happee. 2021. Objective and subjective responses to motion sickness: the group and the individual. Experimental Brain Research 239, 2 (2021), 515–531.
[24] Rifatul Islam, Yonggun Lee, Mehrad Jaloli, Imtiaz Muhammad, Dakai Zhu, Paul Rad, Yufei Huang, and John Quarles. 2020. Automatic detection and prediction of cybersickness severity using deep neural networks from user's physiological signals. In 2020 IEEE international symposium on mixed and augmented reality (ISMAR). IEEE, 400–411.
[25] Susanne M Jaeggi, Martin Buschkuehl, Walter J Perrig, and Beat Meier. 2010. The concurrent validity of the N-back task as a working memory measure. Memory 18, 4 (2010), 394–412.
[26] Dayoung Jeong, Mingon Jeong, Ungyeon Yang, and Kyungsik Han. 2022. Eyes on me: Investigating the role and influence of eye-tracking data on user modeling in virtual reality. PLoS One 17, 12 (2022), e0278970.
[27] Brendan John. 2019. Pupil diameter as a measure of emotion and sickness in VR. In Proceedings of the 11th ACM Symposium on Eye Tracking Research & Applications. 1–3.
[28] Robert S Kennedy, Norman E Lane, Kevin S Berbaum, and Michael G Lilienthal. 1993. Simulator sickness questionnaire: An enhanced method for quantifying simulator sickness. The international journal of aviation psychology 3, 3 (1993), 203–220.
[29] Behrang Keshavarz and Heiko Hecht. 2011. Validating an efficient method to quantify motion sickness. Human factors 53, 4 (2011), 415–426.
[30] Hyewon Kim, Dong Jun Kim, Won Ho Chung, Kyung-Ah Park, James DK Kim, Dowan Kim, Kiwon Kim, and Hong Jin Jeon. 2021. Clinical predictors of cybersickness in virtual reality (VR) among highly stressed people. Scientific reports 11, 1 (2021), 12139.
[31] Hyun K Kim, Jaehyun Park, Yeongcheol Choi, and Mungyeong Choe. 2018. Virtual reality sickness questionnaire (VRSQ): Motion sickness measurement index in a virtual reality environment. Applied ergonomics 69 (2018), 66–73.
[32] Hae-Young Kim. 2017. Statistical notes for clinical researchers: Chi-squared test and Fisher's exact test. Restorative dentistry & endodontics 42, 2 (2017), 152.
[33] Yoon Sang Kim, JufHe Won, Seong-Wook Jang, and Junho Ko. 2022. Effects of cybersickness caused by head-mounted display-based virtual reality on physiological responses: Cross-sectional study. JMIR serious games 10, 4 (2022), e37938.
[34] Panagiotis Kourtesis, Josie Linnell, Rayaan Amir, Ferran Argelaguet, and Sarah E MacPherson. 2023. Cybersickness in virtual reality questionnaire (csq-vr): A validation and comparison against ssq and vrsq. In Virtual worlds, Vol. 2. MDPI.
[35] Daniel Lakens, Anne M Scheel, and Peder M Isager. 2018. Equivalence testing for psychological research: A tutorial. Advances in Methods and Practices in Psychological Science 1, 2 (2018), 259–269.
[36] Jinyoung Lee et al. 2021. Predicting Cybersickness Based on User's Gaze Behaviors in Head-Mounted Display Virtual Reality. Journal of Computational Design and Engineering 8, 2 (2021), 728–739. doi:10.1093/jcde/qwab007
[37] Iverton B Lima, Yewon Jeong, Chaeyeon Lee, Gangseok Suh, and Wonil Hwang. 2021. Severity of usability problems and system usability scale (Sus) scores on augmented reality (ar) user interfaces. ICIC Express Lett. Part B Appl 12, 2 (2021), 175–183.
[38] Yang Long, Tieyan Wang, Xiaoliang Liu, Yujiang Li, and Da Tao. 2025. Toward accurate cybersickness prediction in virtual reality: A multimodal physiological modeling approach. Sensors 25, 18 (2025), 5828.
[39] Ahmad Lotfi, Reza Ebrahimpour, and Sajjad Zabbah. 2025. Recency bias; a strategy to compensate for the lack of evidence. (2025).
[40] Anna Manelis, Hang Hu, Rachel Miceli, Skye Satz, and Marie Schwalbe. 2023. Neural correlates of the sound facilitation effect in the modified Simon task in older adults. Frontiers in aging neuroscience 15 (2023), 1207707.
[41] Sebastiaan Mathôt, Jeroen Fabius, Ellen Van Heusden, and Stefan Van der Stigchel. 2018. Safe and Sensible Preprocessing and Baseline Correction of Pupil-Size Data. Behavior Research Methods 50, 1 (2018), 94–106. doi:10.3758/s13428-017-1007-2
[42] A. Mazloumi Gaygani, Fraser R. Walker, Deborah M. Hodgson, and Eugene Nalivaiko. 2018. A Comparative Study of Cybersickness During Exposure to Virtual Reality and "Classic" Motion Sickness: Are They Different? Journal of Applied Physiology 125, 6 (2018), 1670–1680. doi:10.1152/jappphysiol.00338.2018
[43] Katherine J Mimnaugh, Evan G Center, Markku Suomalainen, Israel Becerra, Eliezer Lozano, Rafael Murrieta-Cid, Timo Ojala, Steven M LaValle, and Kara D Federmeier. 2023. Virtual reality sickness reduces attention during immersive experiences. IEEE transactions on visualization and computer graphics 29, 11 (2023), 4394–4404.
[44] Mahsa Nasri et al. 2024. Exploring Eye Tracking as a Measure for Cognitive Load Detection in Virtual Reality. In Proceedings of the ACM Symposium on Eye Tracking Research and Applications.
[45] Tongyu Nie, Ville Cantory, Courtney Hutton Pospick, Danhua Zhang, Haoyu Tan, Sam Adeniyi, Fei Wu, Daniel Zielasko, Isayas Berhe Adhanom, and Evan Suma Rosenberg. 2026. Revenge of the Sick: A Meta-Analysis of Washout Periods in Cybersickness Research. IEEE Transactions on Visualization and Computer Graphics (2026).
[46] Adrian M Owen, Kathryn M McMillan, Angela R Laird, and Ed Bullmore. 2005. N-back working memory paradigm: A meta-analysis of normative functional neuroimaging studies. Human brain mapping 25, 1 (2005), 46–59.
[47] Stephen Palmisano, Robert S Allison, Joel Teixeira, and Juno Kim. 2023. Differences in virtual and physical head orientation predict sickness during active head-mounted display-based virtual reality. Virtual Reality 27, 2 (2023), 1293–1313.
[48] Witold Pawelczyk, Dorota Olejarz, Zofia Gawel, Magdalena Merta, Aleksandra Nowakowska, Magdalena Nowak, Anna Rutkowska, Ladislav Batalik, and Sebastian Rutkowski. 2025. Understanding cybersickness and presence in seated VR: A foundation for exploring therapeutic applications of immersive virtual environments. Journal of Clinical Medicine 14, 8 (2025), 2718.
[49] Maria Plaza, Carmen Real, Ana Serrano, and Diego Gutierrez. 2026. Design and Evaluation of a Continuous Interface for Real-time Self-reporting of VR Sickness. In Proceedings of the Extended Abstracts of the 2026 CHI Conference on Human Factors in Computing Systems. 1–7.
[50] AJC Reuten, SAE Nooij, JE Bos, and JBJ Smeets. 2021. How feelings of unpleasantness develop during the progression of motion sickness symptoms. Experimental brain research 239, 12 (2021), 3615–3624.
[51] Susana Rubio, Eva Diaz, Jesús Martín, and José M Puente. 2004. Evaluation of subjective mental workload: A comparison of SWAT, NASA-TLX, and workload profile methods. Applied psychology 53, 1 (2004), 61–86.
[52] Jun Ryu and Gerard J Kim. 2026. Predicting Cybersickness Trend and Extent Based on FMS Labeled Dataset. IEEE Transactions on Visualization and Computer Graphics (2026).
Saha et al.
[53] NC Sepich, A Jasper, S Fieffer, SB Gilbert, MC Dorneich, and JW Kelly. 2022. The impact of task workload on cybersickness. Frontiers in Virtual Reality, 3.
[54] Lou Seropian, Mathieu Ferschneider, Fanny Cholvy, Christophe Micheyl, Aurélie Bidet-Caulet, and Annie Moulin. 2022. Comparing methods of analysis in pupillometry: application to the assessment of listening effort in hearing-impaired patients. Heliyon 8, 6 (2022).
[55] Beata Sokolowska. 2023. Impact of virtual reality cognitive and motor exercises on brain health. International journal of environmental research and public health 20, 5 (2023), 4150.
[56] Sean Titensor, Joshua Ebbert, Karen Della Corte, and Dennis Della Corte. 2025. Estimating area under the curve from graph-derived summary data: a systematic comparison of standard and Monte Carlo approaches. BMC Medical Research Methodology 25, 1 (2025), 197.
[57] Hannah Walter, Ruixuan Li, Justin Munafro, Christopher Curry, Nicolette Peterson, and Thomas Stoffregen. 2019. A brief explanation of the Simulator Sickness Questionnaire (SSQ). APAL Coupling Study (2019), 9–10.
[58] Brady T West, Kathleen B Welch, and Andrzej T Galecki. 2022. Linear mixed models: a practical guide using statistical software. CRC Press.
[59] Christopher D Wickens. 2008. Multiple resources and mental workload. Human factors 50, 3 (2008), 449–455.
[60] Matthew B. Winn, Dirk Wendt, Thomas Koelewijn, and Stefan E. Kuchinsky. 2018. Best Practices and Advice for Using Pupillometry to Measure Listening Effort: An Introduction for Those Who Want to Get Started. Trends in Hearing 22 (2018), 1–32. doi:10.1177/2331216518800869
[61] Yitong Zhu, Zhuowen Liang, Yiming Wu, Tangyao Li, and Yuyang Wang. 2025. Towards consumer-grade cybersickness prediction: Multi-model alignment for real-time vision-only inference. In Proceedings of the 33rd ACM International Conference on Multimedia. 6859–6867.
[62] Daniel Zielasko, Ben Rehling, Bernadette von Dawans, and Gregor Domes. 2026. Do not immerse and drive? prolonged effects of cybersickness on physiological stress markers and cognitive performance. Virtual Reality 30, 2 (2026), 78.
A Appendix: Wearable sensors
Table 4. Overview of Collected Data Modalities, Features, Sampling Rates, and Devices
| Modality | Features | Sampling Rate | Device | |
|---|---|---|---|---|
| GSR | Galvanic skin response | 128 Hz | Shimmer GSR | Consensys |
| PPG | Photoplethysmogram | 128 Hz | Shimmer GSR | Consensys |
| Accelerometer / Gyroscope | Motion | 128 Hz | Shimmer GSR | Consensys |
| ECG | Cardiac electrical activity | 120 Hz | Polar H10 | |
| Eye Tracking (baseline) | Gaze direction, pupil diameter | 200 Hz | Pupil Core | |
| Eye & Head Tracking (simulation) | Gaze direction, pupil diameter, eye openness, head orientation | 120 Hz | HP Omnicept SDK (Reverb G2) |
B Appendix: Rationale for Baseline Data Collection
We collected pre-exposure baseline data to characterize each participant’s typical physiological and eye-movement state before exposure to the motion-provoking VR simulation. Physiological measures such as ECG, GSR, and PPG vary substantially across individuals [13]. The baseline recording therefore allowed simulation-window features to be expressed relative to each participant’s own pre-exposure state, reducing the influence of between-participant differences.
For eye tracking baseline, participants viewed a uniform grey background while following white spheres that appeared at different locations. The grey background provided stable, visually simple illumination and avoided optic flow, scene motion, and visually complex content before the simulation. This was particularly important for pupil measures, because pupil diameter is strongly affected by the luminance of the viewed region. Maintaining a consistent background and target appearance reduced pupil-size changes caused by luminance variation rather than cybersickness [41, 60].
The appearing spheres provided standardized gaze targets across multiple display locations. Asking participants to follow the spheres allowed us to obtain controlled samples of fixation and saccade behavior while limiting variation from unconstrained free viewing. Fixation- and saccade-related measures have been examined as potential indicators of cybersickness and cognitive demands in VR [36, 44]. Thus, the eye-tracking baseline provided a participant-specific reference for these measures before participants encountered visually provocative virtual motion.
We repeated the grey-background and sphere-following procedure inside the HMD. This in-VR baseline captured eye-tracking data under the headset’s display, optical, and eye-tracking geometry, which can differ from conventional screen-based viewing. Together, the outside-VR and in-VR baseline recordings helped distinguish participant-specific pre-exposure characteristics from changes associated with the VR simulation.
C Appendix: Data Preprocessing Details
Eye tracking. Raw gaze samples were first cleaned: samples flagged invalid by the eye tracker (e.g., during blinks or tracking loss) were excluded, and pupil diameter was linearly interpolated across those short gaps. Fixations and saccades were then classified from the cleaned gaze stream using an Identification by Velocity Threshold (I-VT) algorithm. From
Saha et al.
this classified stream we calculated fixation counts and mean fixation durations, blink counts and durations, saccade counts and rates, peak velocities and amplitudes, and overall gaze dispersion, together with pupil diameter (mean, standard deviation, and within-window slope).
Head tracking. Raw head-orientation samples (quaternions from the headset's inside-out tracking) were converted to Euler angles and unwrapped to remove discontinuities at the ±180° boundary before feature computation. Head-tracking features summarized angular velocity (mean, standard deviation) and total rotational range from the unwrapped angle series.
Cardiac signals (ECG, PPG). ECG and PPG signals were cleaned and beat-detected using NeuroKit2. Cleaning followed NeuroKit2's default pipeline for each signal type: ECG was high-pass filtered (Butterworth, 0.5 Hz cutoff) to remove baseline wander, with powerline interference removed via a notch filter; PPG was band-pass filtered (Butterworth, 0.5–8 Hz) to isolate the pulsatile component before peak detection. Inter-beat intervals were further filtered to a physiologically plausible 30–240 bpm range to reject artifactual beats before feature computation. From the resulting beat series we derived, per window, mean heart rate, beat count, and standard heart-rate-variability metrics: SDNN (the standard deviation of inter-beat intervals), RMSSD (the root-mean-square of successive inter-beat-interval differences), and, for ECG, pNN50 (the proportion of successive interval differences exceeding 50 ms). The same beat-detection and HRV pipeline was applied independently to the chest-strap ECG and the wrist/finger PPG signal, yielding parallel feature sets for both.
Electrodermal activity (GSR). GSR was processed with NeuroKit2's EDA pipeline. The raw signal was first low-pass filtered (Butterworth, 3 Hz cutoff) to remove high-frequency noise, then decomposed into a tonic skin-conductance level (SCL) and a phasic component from which discrete skin-conductance responses (SCRs) are detected. From this decomposition we derived, per window, mean SCL, SCR count, SCR rate (per minute), and mean SCR amplitude, together with the standard deviation of the raw (unfiltered) GSR signal as a coarse measure of overall electrodermal variability.
D Appendix: Study Protocol
This study was reviewed and approved by the Institutional Review Board (IRB) of ANONYMOUS prior to data collection. All participants provided written informed consent before beginning the study and were informed that the VR experience could induce mild to severe cybersickness symptoms.
Inclusion Criteria. Participants were required to be at least 18 years of age, have normal or corrected-to-normal vision, and be able to attend the study session in person.
Exclusion Criteria. Participants were excluded if they reported a history of epilepsy, vestibular disorders, pregnancy or hearing impairments, as well as any other condition that could be exacerbated by VR exposure or interfere with the auditory Simon task. Participants with uncorrected vision impairments that could interfere with the VR display or eye-tracking calibration were also excluded. Participants were instructed to refrain from consuming a heavy meal for at least one hour prior to the study. Participants were informed that they could withdraw from the study at any time, for any reason, without penalty, and were explicitly instructed to notify the research team immediately if they experienced severe discomfort during the simulation.
E Appendix: Description of Extracted Features
This appendix provides a brief description of all the physiological and behavioral features extracted from the dataset over predefined windows.
Electrocardiogram (ECG) Features
The ECG features primarily capture heart rate and heart-rate variability (HRV) metrics.
-
ecg_hr_mean_bpm: Mean heart rate in beats per minute (BPM).
-
ecg_hr_std_bpm: Standard deviation of the heart rate.
-
ecg_sdnn_ms: Standard deviation of normal-to-normal RR intervals in milliseconds.
-
ecg_rmssd_ms: Root mean square of successive differences between normal RR intervals in milliseconds.
-
ecg_pnn50: Proportion of successive RR interval pairs that differ by more than 50 ms.
-
ecg_beat_count: Total number of detected heartbeats within the window.
Photoplethysmography (PPG) Features
The PPG features similarly capture heart rate, HRV metrics, and signal amplitude statistics.
-
ppg_hr_mean_bpm: Mean heart rate calculated from PPG peaks.
-
ppg_hr_std_bpm: Standard deviation of the heart rate.
-
ppg_sdnn_ms: Standard deviation of inter-beat intervals in milliseconds.
-
ppg_rmssd_ms: Root mean square of successive differences between inter-beat intervals.
-
ppg_amplitude_mean: Mean amplitude of the raw PPG signal.
-
ppg_amplitude_std: Standard deviation of the raw PPG signal amplitude.
-
ppg_beat_count: Total number of detected beats from the PPG signal.
Eye-Tracking Features
Eye-tracking features are derived from pupil diameter, blink events, and I-VT (Velocity-Threshold Identification) based gaze fixations and saccades.
-
eye_pupil_diam_mean: Mean combined pupil diameter.
-
eye_pupil_diam_std: Standard deviation of the pupil diameter.
-
eye_pupil_diam_slope: Linear regression slope of the pupil diameter over the window.
-
eye_pupil_valid_frac: Fraction of the window with valid (non-zero) pupil diameter readings.
-
eye_blink_rate_per_min: Number of blinks per minute.
-
eye_blink_duration_mean_sec: Mean duration of blinks in seconds.
-
eye_fixation_count: Total number of gaze fixations.
-
eye_fixation_duration_mean_sec: Mean duration of fixations in seconds.
-
eye_fixation_time_frac: Fraction of time spent in fixation over the window.
-
eye_saccade_count: Total number of saccades.
-
eye_saccade_rate_per_min: Rate of saccades per minute.
-
eye_saccade_peak_vel_mean_deg_s: Mean peak angular velocity during saccades (degrees/second).
-
eye_saccade_amplitude_mean_deg: Mean amplitude (distance) of saccades in degrees.
-
eye_gaze_dispersion_deg: Dispersion of the gaze vectors across the window in degrees.
Saha et al.
Galvanic Skin Response (GSR) Features
GSR features summarize electrodermal activity, specifically focusing on tonic levels (Skin Conductance Level - SCL) and phasic responses (Skin Conductance Responses - SCR).
-
gsr_scl_mean: Mean skin conductance level.
-
gsr_scl_slope: Linear regression slope of the skin conductance level over time.
-
gsr_raw_std: Standard deviation of the raw skin conductance signal.
-
gsr_scr_count: Total number of skin conductance response peaks (bursts).
-
gsr_scr_rate_per_min: Rate of SCR bursts per minute.
-
gsr_scr_amplitude_mean: Mean amplitude of the detected SCR peaks.
Head-Tracking Features
Head-tracking features serve as proxies for postural instability and head movement, derived from Euler angles.
-
head_ang_vel_mean_deg_s: Mean rotational angular velocity in degrees per second.
-
head_ang_vel_std_deg_s: Standard deviation of the rotational angular velocity.
-
head_rot_range_deg: Overall range of rotation based on unwrapped Euler angles across the three spatial axes.
F Appendix: Multimodal signal data representation
Received 20 February 2007; revised 12 March 2009; accepted 5 June 2009
Sample 30s window — P32 (3slider), t=[30, 60]s

Fig. 17. A representative 30 s window (session time 30–60 s) of processed multimodal data from a single participant (P32, 3-slider condition) (a) Pupil diameter, with blink periods shaded and excluded from feature computation. (b) Gaze angular velocity with the I-VT threshold (30 deg/s) used to classify saccades (shaded) from fixations. (c) Head angular velocity, showing several rapid head movements exceeding 500 deg/s. (d) Cleaned ECG signal with detected R-peaks. (e) Cleaned PPG signal with detected pulse beats. (f) Raw and tonic (SCL) galvanic skin response, with detected skin-conductance responses (SCRs) marked. Across modalities, event detection (saccades, R-peaks, PPG beats, SCRs) tracks the underlying signal closely, supporting the reliability of the windowed features derived from this pipeline.