arXiv:2611.07358cs.ARNov 2026

Manuscript Offprint

arXiv:2611.07358

A Synchronized Tri-Modality Wireless System for Multi-Point Non-Contact Cardiac Monitoring

Wei Ren, Kaili Zhao, Huansheng Yi, Miaoyang Hu, Jianqi Wang, Canhua Xu, Fugui Qi

Wei Ren, Member, IEEE, Kaili Zhao, Huansheng Yi, Miaoyang Hu, Jianqi Wang, Canhua Xu, and Fugui Qi, Member, IEEE

Abstract—Cardiac physiological monitoring is fundamental to evaluating cardiovascular health and diagnosing related diseases. Non-contact radar sensing can capture chest-wall vibrations with spatial specificity, enabling localized physiological monitoring and cardiac assessment. Progress, however, has been limited by the absence of a reliable, research-grade hardware platform for rigorous validation of radar-based methods. Prior systems typically pair radar, namely Doppler cardiography (DCG), with only electrocardiography (ECG) or other coarse references, providing no direct mechanical ground truth and thus constraining fine-grained evaluation of radar outputs. We present a tri-modality wireless system that integrates ECG, seismocardiography (SCG), and DCG under a unified acquisition and control framework for time-aligned recording and analysis. The tri-modality system combines miniaturized wearable ECG/SCG modules with a high-resolution mmWave radar module, supporting spatially resolved sensing and subsequent feature extraction. To our knowledge, this is the first integrated ECG–SCG–DCG hardware system for comprehensive cardiac monitoring; it enables multi-point thoracic acquisition, achieves precise cross-modal synchronization, and maintains specifications suitable for wearable operation. Experiments on a linear-motion platform show close agreement between DCG- and SCG-derived displacements, confirming accurate displacement measurement. Human-subject studies further demonstrate cross-modal consistency and robust extraction of feature points, establishing ECG as the electrical anchor and SCG as the mechanical ground truth for DCG. Overall, the system provides a rigorous, spatially resolved validation platform that advances non-contact cardiac sensing and supports next-generation radar-based monitoring.

Index Terms—Doppler cardiography (DCG), electrocardiography (ECG), millimeter-wave (mmWave) sensing, physiological monitoring, seismocardiography (SCG)

I. INTRODUCTION

Cardiac physiological monitoring is fundamental to assessing cardiovascular health and diagnosing related disease [1]. Cardiac function can be characterized through two coupled activities: the heart's electrical activity and mechanical vibrations. Electrical activity is routinely measured by electrocardiography (ECG), which provides high temporal resolution markers of depolarization–repolarization (P-QRS-T), robust R-peak timing for cycle delineation, and standardized acquisition/interpretation protocols that establish ECG as the clinical reference for rhythm analysis and heart-rate estimation [2], [3]. However, ECG requires specialized instrumentation and contact-based measurement with skin electrodes, which is inconvenient in many settings. Mechanical activity is captured by seismocardiography (SCG) using chest-mounted accelerometers; SCG reflects thoracic micro-vibrations driven by cardiac mechanics and enables extraction of key feature points—such as aortic-valve opening (AO), aortic-valve closure (AC), mitral-valve closure (MC), and mitral-valve opening (MO) [4]–[8]. In addition, because these surface vibrations originate from distinct cardiac chambers and pulmonary regions, they exhibit intrinsic spatial specificity even within a single cycle, enabling localized and more informative assessment of underlying physiology [9]. Recent advances extend the spatially localized mechanical sensing to non-contact modalities, most notably millimeter-wave (mmWave) radar-based Doppler cardiography (DCG), which infers chest-wall micro displacements without electrodes or skin contact, thereby improving comfort and hygiene while enabling spatially specific measurement of cardiac mechanics as a complement to ECG [10]–[26].

Wei Ren and Kaili Zhao contributed equally to this work. This work was supported in part by the National Natural Science Foundation of China under Grant 62201578; and in part by Joint Founding Projectof Innovation Research Institute, Xijing Hospital (LHJJ24YG14). (Corresponding author: Fugui Qi.)

Wei Ren is with Hong Kong Generative AI Research and Development Center, Hong Kong University of Science and Technology, Hong Kong SAR (email: weiren_thu@163.com).

Kaili Zhao is with the Nursing Department, The Third Affiliated Hospital of Southern Medical University, Guangzhou 510630, China (email: zhaokaili1991@163.com).

Huansheng Yi, Jianqi Wang, and Canhua Xu are with the School of Biomedical Engineering, Fourth Military Medical University, Xi'an 710032, China (email: Yihsbme@outlook.com, wangjq@fmmu.edu.cn, canhuaxu@fmmu.edu.cn).

Miaoyang Hu is with the Department of Cardiology, Xijing Hospital, Fourth Military Medical University, Xi'an, 710032, China (email: hu-miaoyang@qq.com).

Fugui Qi is with the School of Biomedical Engineering, Fourth Military Medical University, and Military Medical Innovation Center, Fourth Military Medical University, Xi'an 710032, China (email: Qifgbme@outlook.com).

Despite this promise, progress has been constrained by the lack of a reliable, research-grade platform for rigorous validation of radar-based methods. Most current radar-based physiological monitoring and further diagnosis follow a two-stage paradigm: chest-wall displacement or cardiac-motion waveforms are first estimated from radar echoes, and physiological status or cardiac events are then inferred from the estimated motion signals [14], [24], [25], [27]–[30]. Recent TIM studies have substantially improved radar-based cardiac sensing from different perspectives, including high-accuracy cardiac activity extraction, 4-D imaging-radar heartbeat sensing, noncontact ECG reconstruction, and vital-sign estimation under random body movement [24], [26], [31], [32]. The limited performance of existing methods, however, still largely depends on the accuracy and reliability of displacement estimation in the first step. Most existing systems pair DCG with only ECG or other coarse sensors, such as breathing belts and handheld pulse oximeters [17], [26], [31], [33]. While ECG provides an accurate electrical anchor and precise temporal markers (e.g., R-peaks), it is not a mechanical ground truth for radar-based displacement. As a result, fine-grained evaluation of DCG-derived displacement and cardiac feature points remains limited. A validation platform for this application should (i) include a clinical electrical reference (ECG) for timing, cycle delineation, and physiological-status reference, (ii) include a direct mechanical reference such as SCG to serve as ground truth for radar-derived displacement, and (iii) support multi-point, highly synchronized, and convenient data acquisition across the thorax.

To address these needs, we develop a tri-modality wireless system that integrates ECG (electrical), SCG (mechanical), and DCG (radar) within a unified acquisition and control framework to ensure time-aligned recording and analysis. The platform combines miniaturized wearable ECG/SCG modules with a high-resolution mmWave radar module, enabling multi-point thoracic measurements for spatial analysis and subsequent feature extraction. It achieves precise cross-modal synchronization while maintaining specifications suitable for wearable operation.

We demonstrate the performance of this platform in benchtop and human-subject studies. On a programmable linear-motion bench, DCG- and SCG-derived displacements show close agreement (e.g., low root-mean-square error and high Pearson correlation), validating accurate displacement tracking. In human subjects, the system enables robust extraction of cardiac feature events—including AO and MO—with cross-modal consistency; within this framework, ECG serves as the electrical anchor and SCG provides the mechanical ground truth for DCG. Overall, these results establish a rigorous, spatially resolved validation platform that advances non-contact cardiac sensing and supports next-generation radar-based monitoring.

The remaining sections of this paper are organized as follows. Section II details the design of the tri-modality hardware system. Section III describes the methodology for data processing and feature point extraction methods. Section IV reports benchtop and human-subject experiments that validate system performance. Section V concludes the paper.

References (45)