Whole-Body Elasto-Geometrical Calibration of Wheeled Humanoid Robots Using a Shared-Waist Dual-Chain Model

Pengxin Zha, Yi Lu, Haojun Ma, Jun Zhu, Minghao Qiu, Xiaoyan Wang, Wei Shan, Maoqing Yao

Pengxin Zha ID^{ID}, Yi Lu ∗^{*} ID^{ID}, Haojun Ma ID^{ID}, Jun Zhu, Minghao Qiu ID^{ID}, Xiaoyan Wang ID^{ID}, Wei Shan ID^{ID}, Maoqing Yao ID^{ID}

Abstract—Wheeled humanoid robots carry both arms on one actuated waist, usually without torque sensors, so the accuracy of both end-effectors depends on a single waist model. After a first stage that estimates the tracker and target extrinsics, we identify the waist and both arms in one problem from the target positions on both flanges, measured by an optical tracker. The kinematic model is complete, with waist-base, parallel-axis, and branch parameters; arm compliances are driven by measured torques and waist compliances by gravity torques of the robot's mass model; and Gaussian priors with evidence-maximizing scales stabilize the estimate. Independent and sequential single-chain calibration are restrictions of this problem, and its waist information is the sum of the single-chain Schur complements. On two robots with different waists, each without and with a payload, calibration reduces the mean errors on held-out poses from 11.3–31.1 mm to 0.50–1.11 mm. For every training-set size from 20 poses to all, the method has 17–63% lower mean errors than adaptations of two published whole-body calibration methods, mainly through the waist compliance. Independent calibration yields two waist models; using either for both arms raises the other arm's error to up to 3.21 mm.

Index Terms—Calibration and identification, humanoid robot systems, kinematics, compliant joints and mechanisms.

I. INTRODUCTION

HUMANOID robots are moving from research laboratories into industrial work [1]. Wheeled humanoids replace the legs with a mobile base and carry both arms on an actuated waist. In dual-arm tasks, both end-effectors must be accurate in one common base frame, and both depend on the same waist: an error in the waist model moves both hands at once, while geometric deviations along each chain accumulate at the end-effectors [2], [3]. Harmonic drives add compliance, so joint deflections under load add to the geometric errors [2], [4]. The waist joints carry the upper body and both arms, but on wheeled humanoids they usually have no torque sensors.

Industrial manipulators are calibrated with external instruments such as laser trackers [5]; the identifiable parameters [6] of a linearized error model of the serial chain are then estimated from the measurements [7]. Elasto-geometrical calibration adds joint compliances driven by the joint loads [4], [7], [8]; without joint torque sensors, the loads follow from a gravity model of the links, which can be identified from the same calibration poses [8] or together with the kinematic parameters [7], [9], and the pose of a joint axis also varies with the posture of the axes that follow it [10]. Systems of

two manipulators are calibrated with a holistic error model of the link parameters and of the base, camera, and marker transforms [11], or with one arm as the measuring instrument of the other [12]; on an industrial dual-arm robot, calibrating the cameras first and then the kinematics was more effective than calibrating all parameters simultaneously [13]. The two arms of a humanoid, however, share the waist joints, which raises the question of how the shared parameters are identified.

Early humanoid calibration relied on onboard sensors: head-mounted stereo cameras for the upper body [14], self-touch with artificial skin to close a kinematic chain [15], and link orientation sensors with both feet flat on the floor for the joint offsets [16]; Tanguy et al. [17] calibrated the geometric parameters of the whole kinematic tree online. In simulation on iCub, calibrating a chain together with other chains that share joints with it improved the optimization results and the observability [18]. Tenhumberg and Bäuml [19] modeled the upper body of Agile Justin with joint and transversal elasticities under its own weight, and identified its Denavit-Hartenberg parameters and elasticities by least squares with priors from the end-effector positions of both arms, measured by an external tracking system, which reduced the mean position error from 21 to 3.1 mm.

Two recent works calibrate the whole body of a humanoid and evaluate it by cross-validation. Bonnet et al. [2] calibrated the bipedal TALOS with motion capture and its joint torque sensors: the head-trunk and both arms were identified in one least-squares problem that shares the trunk parameters, elasticities were driven by the measured torques, and identifiable parameters were selected by a QR decomposition on simulated configurations; the cross-validated marker error was 2.2 mm RMS. Nguyen et al. [3] calibrated TALOS without external instruments, from contacts of the gripper with a single plane: two foot-to-hand chains, whose four identifiable torso parameters are common, are identified geometrically with a parameterization in the Unified Robot Description Format (URDF), and the cross-validated plane-contact error dropped by a factor of 2.3 relative to the manufacturer's model. Neither work reports how much the shared parameters gain over identifying the chains independently or one after the other, and neither addresses a wheeled robot whose waist carries no torque sensors.

This article studies these questions on wheeled humanoids calibrated in production with an optical tracker. Its contributions are as follows.

  • A shared-waist dual-chain elasto-geometrical calibration for wheeled humanoids with a general waist (any number of revolute or prismatic joints): two stages separate the

This work is being submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may no longer be accessible.

The authors are with AgiBot, China. *Corresponding author: Yi Lu (e-mail: luyi@zhiyuan-robot.com).

tracker and target extrinsics from the body model; waist-base, parallel-axis [20], and branch parameters complete the modified Denavit–Hartenberg (MDH) model; waist compliances about and perpendicular to the joint axes are driven by the gravity torques of the mass model of the robot description; and Gaussian priors, whose scales maximize the evidence of the training data, stabilize the estimate. The identification runs in the production calibration software of the robots.

  • An identifiability analysis in which independent and sequential single-chain calibration are row and column restrictions of the same system, and the dual-chain waist information is exactly the sum of the two single-chain Schur complements.

• Experiments on two robots with different waists, each without load and with a payload, that compare the dual-chain formulation with independent and sequential calibration and with adaptations of [2], [3] on held-out poses, for training sets from 20 poses to all, and that quantify the contribution of each part of the model.

References (29)