arXiv:2611.07814cs.CVNov 2026

Manuscript Offprint

arXiv:2611.07814

CMDiff: Left Atrial Scar Segmentation from 3D LGE MRI Using Conditional Mask Diffusion Model: A Feasibility Study

Jing Zhang, Bastien Bergere, Jonas Leite, Emilie Bollache, Mikaël Laredo, Alban Redheuil, Nadjia Kachenoura

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Jing Zhang¹ Bastien Bergere¹ Jonas Leite¹ Emilie Bollache¹ Mikaël Laredo¹,² Alban Redheuil¹,³ Nadjia Kachenoura¹

¹ Laboratoire d'Imagerie Biomédicale (LIB), Sorbonne Université, INSERM, CNRS, Paris, France

² APHP, Institut de Cardiologie, Hôpital Pitié-Salpêtrière, Paris, France

³ APHP, Imagerie Cardiovasculaire et Thoracique, Institut de Cardiologie, Hôpital Pitié-Salpêtrière, Paris, France

Abstract. Late gadolinium enhancement (LGE) cardiac MRI enables non-invasive assessment of left atrial (LA) scar, an imaging marker associated with atrial fibrillation ablation outcome. However, automatic scar segmentation is hindered by low contrast, the thin atrial wall, scarce labels, and extreme class imbalance. Conditional diffusion offers iterative mask generation, but its suitability for sparse 3D LA scar segmentation remains unclear. To address this gap, we propose Conditional Mask Diffusion (CMDiff), which predicts clean masks using a dynamic-encoder-conditioned 3D sinusoidal UNet. We compared CMDiff with a deterministic baseline on identical cases in five-fold cross-validation of 60 scar-labelled public LASCARQS subjects, with 48 training and 12 held-out cases per fold. CMDiff achieved a scar DSC of 0.47 ± 0.08, HD95 of 12.89 ± 6.39 mm, and ASD of 1.91 ± 0.96 mm, compared with deterministic baseline values of 0.51 ± 0.08, 10.86 ± 5.39 mm, and 1.58 ± 1.03 mm, respectively. Under the same implementation, clean-mask prediction performed substantially better than the noise-prediction configuration evaluated in this study. Thus, CMDiff was technically feasible but did not improve segmentation performance: DSC was lower, and both HD95 and ASD were higher. Direct mask diffusion therefore provides an analytical alternative, but not a competitive performance advance for this task. The source code is publicly available at https://github.com/jizhang02/CMDiff.

Keywords: Atrial fibrillation, left atrial scar, LGE-MRI, diffusion probabilistic model, segmentation.

J. Zhang et al.

1 Introduction

Atrial fibrillation (AF) is the most prevalent sustained cardiac arrhythmia, affecting an estimated 37.6 million people worldwide and increasing the risks of stroke, heart failure, and mortality [1]. Catheter ablation is an established rhythm-control therapy for symptomatic AF, but recurrence remains common. Because the burden and spatial distribution of left atrial (LA) fibrosis have been associated with ablation outcome [2], late gadolinium enhancement (LGE) cardiac MRI may help characterise the atrial substrate before treatment and scar after treatment [3].

Converting LGE-MRI into reliable scar maps is nevertheless difficult. Scar-related signal is subtle and confined to the thin LA wall (~2–4 mm), where it can resemble enhancement from the blood pool or adjacent tissue. Scar voxels are also sparse, manual boundaries vary between observers, and image appearance differs across patients, scanners, and acquisition protocols [4]. These constraints motivate segmentation methods that combine local LGE appearance with explicit anatomical context.

Early approaches treated scar mainly as an intensity outlier, using thresholding or standardised intensity rules [5,6]. Convolutional encoder–decoder models then learned appearance and volumetric context directly from images [7–9], while nnU-Net provided a strong self-configuring baseline [10]. Cardiac-specific methods further combined learned scar likelihoods with graph-cut regularisation, multi-view information, attention, spatial encoding, or joint LA-scar objectives [11–17].

More recent methods increasingly constrain scar to the LA wall. A boundary-focused nnU-Net used the predicted LA distance map and reported a scar DSC of 64.08% on public LASCARQS dataset [18]; an anatomy-conditioned two-stage pipeline combined cavity and wall signed-distance maps with wall-restricted, boundary-aware supervision and reported 61.1% [19]. Our prior work similarly used a coarse LA prediction to constrain SwinUNETR-based scar delineation [20–22]. These values are contextual rather than directly comparable because data partitions, model selection, and evaluation implementations may differ. Collectively, however, they show that deterministic performance depends strongly on how anatomy is incorporated.

These anatomy-aware models remain deterministic: each image produces one mask. Diffusion models offer a different formulation by reversing a gradual noising process from different noise initialisations [23]. Applied to segmentation, the mask is denoised while the medical image supplies the condition. This principle has supported implicit segmentation ensembles [24], noise-prediction and dynamic-conditioning models [25, 26], and distributions of plausible masks learned from multiple expert annotations [27].

Within cardiac imaging, diffusion has been used to enhance left-ventricular scar contrast [28] and generate synthetic atrial fibrosis distributions [29], rather than segment patient-specific LA scar masks. Whether a 3D mask-denoising process can recover LA scar directly from LGE-MRI therefore remains unresolved.

To address this gap, we study diffusion as an alternative rather than a presumed replacement for deterministic segmentation. We test whether 3D Con-ditional Mask Diffusion (CMDiff) can approach a matched deterministic baseline, identify effective and ineffective design choices under a common implementation, and describe repeated-sample variability without treating it as calibrated uncertainty. CMDiff predicts the clean mask at each denoising step to align the diffusion output with the sparse binary target.

This paper makes the following contributions:

  1. We present CMDiff, to our knowledge the first task-specific feasibility and failure-mode study of 3D LA scar segmentation formulated as mask diffusion conditioned on the LGE image.

  2. We compare clean-mask and noise-prediction parameterisations under the same implementation and show that only clean-mask prediction produces useful scar masks in this experimental configuration.

  3. We use a lightweight Dynamic Conditional Encoder (DCE) to inject multi-scale LGE features into the denoising process.

  4. We conduct target, conditioning, and sampler ablations; compare CMDiff with a specialised deterministic LA scar segmentation model on identical held-out cases; and describe stochastic sample disagreement through entropy and variance maps.

References (35)