Manuscript Offprint
arXiv:2611.05442Matched but Not Better: An Equivalence-Tested Benchmark of Quantum Machine Learning on Six Clinical Datasets and the QML-Health-READY Reporting Framework
Abstract
Background: Quantum machine learning (QML) is promoted for clinical prediction, but its comparisons with classical models are rarely paired or tested for equivalence.
Methods: On six public clinical datasets, we compared a quantum-kernel support vector machine (QSVM; 4 qubits, tuned bandwidth) and a variational quantum classifier (VQC) with five tuned classical models, using identical four-component inputs and 25 identical cross-validation splits. Paired differences in the area under the ROC curve (AUROC) were assessed with a corrected resampled t-test, Holm-adjusted equivalence tests (margins ±0.02 and ±0.05) and random-effects pooling. Ablation, noise, finite-shot and implementation-fault analyses followed. We propose QML-Health-READY, an eight-domain reporting framework.
Results: No quantum model significantly outperformed any classical comparator. Pooled across datasets, QSVM differed from the kernel-matched radial basis function (RBF) SVM by -0.006 AUROC (95% CI -0.017 to +0.004; equivalent within ±0.02), and the VQC differed from the best classical model by -0.007 (-0.019 to +0.004). Per dataset, QSVM was equivalent to the RBF SVM within ±0.05 on 4 of 6 but significantly worse than the best classical model on NHANES 2017–18 (-0.076). A classically trivial product-state kernel performed as well as the entangling kernel. With p = 0.01 depolarising noise and 1,024 shots per kernel entry, QSVM AUROC fell by a pooled 0.054 (0.036–0.071); an untuned bandwidth gave near-chance AUROC (0.48–0.59).
Conclusions: Correctly configured quantum classifiers approached, but did not exceed, tuned classical models; finite-shot estimation, not gate noise, was their main practical cost, and configuration errors alone could reverse the conclusion. QML-Health-READY specifies the reporting that credible claims require.
Keywords: Quantum machine learning; Quantum kernel; Equivalence testing; Benchmarking, Reporting guideline; Clinical prediction
1. Introduction
Machine learning is now embedded in clinical research and practice [1,2]. Noisy intermediate-scale quantum (NISQ) hardware [3] has prompted parallel interest in quantum machine learning (QML), in which a parameterised quantum circuit serves as a feature map or kernel [4–6]. The quantum support vector machine (QSVM) was proposed with a logarithmic-runtime claim [7], and the exponentially large Hilbert space has been argued to offer expressive power unavailable to classical models [8,9]. For clinical prediction the question is practical: whether a quantum model discriminates better than a well-tuned classical one, at a cost a health system could bear. Overstated claims can divert research effort and funding from methods that already work.
The evidence has not followed. A 2025 systematic review identified 4,915 records (2015 to June 2024), evaluated 46 studies of QML for digital health in detail after excluding many for insufficient rigour, found that only 16 tested algorithms under realistic conditions (quantum hardware or noisy circuits), and concluded that there is not yet clear evidence of an empirical advantage [10]. A benchmark of 12 QML models on 160 datasets found that out-of-the-box classical models outperformed the quantum classifiers [11], earlier reviews were similarly cautious [12], and dequantisation results show that classical algorithms can often match proposed quantum speed-ups or trained quantum models [13,14]. Independent benchmarks from 2025 and 2026 point the same way: quantum-kernel SVMs on nine tabular datasets, validated on IBM hardware, showed no significant advantage in any of 29 comparisons [15], and a multi-modal oncology benchmark found no evidence of quantum advantage [16]. Applied medical studies nevertheless continue to appear, on hardware [17] and in simulation [18], and recent reviews document highly heterogeneous methods [19].
Several mechanisms behind these results are now understood. Quantum fidelity kernels concentrate exponentially with qubit count [20]; performance depends strongly on a bandwidth hyperparameter [21,22], and once that bandwidth is tuned the kernels become close to classical RBF or low-order polynomial kernels [23]; and concentration and spread effects inflate the number of measurement shots that kernel estimation requires [24]. These results come mostly from physics and machine-learning benchmarks. What is missing for clinical prediction is evidence of three kinds: whether quantum and classical models are equivalent, rather than merely “not significantly different”, under identical inputs and splits; how large the shot cost is on clinical data once bandwidth is tuned; and how far implementation choices alone can move the conclusion. Our contributions are: (i) a synthesis of seven reasons why medical QML advantage claims are fragile; (ii) QML-Health-READY, an eight-domain reporting and readiness framework aligned with TRIPOD+AI, CLAIM and FUTURE-AI [25–27]; (iii) a matched, paired, equivalence-tested benchmark on six clinical datasets with a kernel-matched classical comparator; (iv) an empirical quantification of the finite-shot penalty and of its interaction with bandwidth tuning; and (v) an implementation-sensitivity experiment showing how plausible configuration faults reverse the conclusion.
Quantum models are kernel methods (domain A). Supervised QML models that embed data in Hilbert space and measure a linear observable are kernel methods [5,28]. Whether a quantum kernel beats an RBF or polynomial kernel is an empirical, data-dependent question, and expressive power depends on the encoding [29,30].
Advantage depends on data structure (domain R). A quantum learning advantage requires a large geometric difference between quantum and classical kernels on the data at hand [31]; without such an analysis an advantage claim has no theoretical basis.
Dequantisation (domain Y). Quantum-inspired classical algorithms have matched several proposed speed-ups [13], random-Fourier-feature models can approximate trained quantum kernel and variational models under stated conditions [14], and the regimes in which quantum and classical models make different predictions are being characterised [32].
Benchmarking practice (domain A). Results are highly sensitive to experimental design [11,33]. A tuned quantum model compared with an untuned classical model, or one given different inputs, yields uninformative results.
Trainability and noise (domain R). Variational circuits can exhibit barren plateaus [34,35], noise induces similar effects [36], and many models that provably avoid barren plateaus can be simulated classically once data are collected from the device [37].
Data loading and clinical realism (domain D). Amplitude encoding of an n-dimensional vector into qubits needs on the order of n gates — exponential in the number of qubits — which removes logarithmic speed-ups [38]. Angle encoding is tractable but forces strong dimensionality reduction, so classical comparators must receive the same reduced inputs or the asymmetry must be reported.
Kernel scaling, bandwidth and concentration (domain E). Fidelity kernels concentrate exponentially with qubit count, making Gram matrices nearly diagonal [20]. Performance depends strongly on a bandwidth hyperparameter [21,22]; at the small bandwidths that generalise well, quantum kernels become close to RBF or low-order polynomial kernels [23,39], and estimating nearly constant kernel entries demands many measurement shots [24]. Untuned encodings can therefore produce spurious failures, and tuned encodings can produce results that are strong but classically approximable and costly to measure.
3. The QML-Health-READY framework
QML-Health-READY has eight domains (R, E, A, D, Y; R, E, Y), each mapped to the failure modes of Section 2 (Table 1). Items are answered Yes, Partial, No or Not applicable with a one-line justification. Studies meeting all Core items (†) are READY-Reportable; readiness tiers are defined in Supplementary Table S1, and our own self-assessment is in Supplementary Table S6. Meeting the Core items is necessary for credible reporting and does not imply clinical usefulness. Section 5.9 reports, for each domain, an effect measured in this study that the corresponding items would have detected.
Table 1. QML-Health-READY domains. † Core item.
| Domain | Name | Items |
|---|---|---|
| R† | Rationale | Hypothesised mechanism for advantage; data-complexity analysis (geometric difference, kernel alignment) [31,40]. |
| E† | Encoding | Encoding, feature scaling, kernel bandwidth and its selection procedure (checking grid edges), dimensionality reduction fitted within training folds, qubit count [21,23]. |
| A† | Algorithm & baselines | ≥ 4 tuned classical baselines including a kernel-matched classical model, given the same inputs and tuning budget; entanglement-ablated quantum model [11]. |
| D† | Data & splits | Provenance, sample size, class balance, subject-level splitting, leakage audit (including post-baseline predictors). |
| Y† | Yield | Repeated nested cross-validation with identical splits for all models; paired tests corrected for split dependence [41,42]; equivalence testing with a pre-specified margin when parity is claimed [43,44]; multiplicity control. |
| R† | Robustness | Explicit noise model (verified to be active) and finite-shot estimation; hardware-calibrated noise or real hardware where feasible [20,36]. |
| E | Evaluation in context | Calibration, threshold-dependent metrics, decision-curve analysis, external validation; alignment with TRIPOD+AI, CLAIM and FUTURE-AI [25–27]. |
| Y | Yardstick for cost | Wall-clock time, circuit executions and shots per fit versus classical baselines; data-access assumptions; dequantisation check [13,14]. |
4. Methods
The study is a matched, paired benchmark of two quantum classifiers against five tuned classical models on six public clinical datasets, with all quantum results obtained by classical simulation. Sections ??–?? describe the data, models, statistical analysis and kernel diagnostics.
4.1 Datasets
We used six public datasets (Table 2): Breast Cancer Wisconsin (benign coded as class 1, as distributed; AUROC is invariant to this choice); Heart Disease Cleveland (processed UCI file, incomplete rows removed, any disease positive); Pima Indians Diabetes (zero values for glucose, blood pressure, skin thickness, insulin and BMI treated as missing and median-imputed within each training fold); Heart Failure Clinical Records [45] with follow-up time removed because it is recorded after baseline; TCGA-BRCA oestrogen-receptor status [46,47] from Illumina HiSeq expression percentiles, restricted to primary tumours with one sample per patient (all 780 ER-labelled samples met this criterion) and to the 200 highest-variance genes, a label-free filter; and NHANES 2017–18 adults [48], with diabetes defined as HbA1c ≥ 6.5% or a physician diagnosis and HbA1c excluded from the predictors to avoid target leakage (a stratified random sample of 2,000 of 4,483 eligible adults with complete data; survey weights not applied).
Table 2. Datasets. Prevalence is the fraction of class 1, the positive class for AUROC.
| Dataset | Domain | Source | n | Predictors | Class 1 | Prevalence |
|---|---|---|---|---|---|---|
| Breast Cancer Wisconsin | Oncology | scikit-learn / UCI | 569 | 30 | benign tumour | 63% |
| Heart Disease Cleveland | Cardiology | UCI | 297 | 13 | any heart disease | 46% |
| Pima Indians Diabetes | Metabolic | UCI (mirror) | 768 | 8 | diabetes | 35% |
| Heart Failure | Cardiology | UCI | 299 | 11 | death during follow-up | 32% |
| TCGA-BRCA | Genomic oncology | UCSC Xena | 780 | 200 | ER-positive | 77% |
| NHANES 2017–18 | Epidemiology | CDC NHANES | 2,000 | 6 | diabetes | 18% |
4.2 Models
Within each outer training fold we fitted median imputation, standardisation, principal component analysis (PCA) to 4 components and re-standardisation of the components; all models received exactly these four inputs, and the classical models were additionally fitted on all standardised predictors to quantify the cost of the reduction. Classical models (L2 logistic regression, support vector machines (SVMs) with radial basis function (RBF) and polynomial kernels, random forest, gradient boosting) were tuned by 3-fold inner grid search on AUROC [49] (grids in Supplementary Table S5).
The QSVM uses the ZZ feature map [4] with 2 repetitions on a linear chain: Hadamard and on each qubit, then , where are the standardised components and is a bandwidth [21,22]. The fidelity kernel was computed by exact state-vector simulation in PennyLane 0.45.1 [50]. Bandwidth (0.005, 0.01, 0.02, 0.05, 0.1, 0.2, 0.5, 1.0) and C (0.1, 1, 10) were tuned by 3-fold inner cross-validation on the AUROC of the SVM decision function, and the SVM was refitted on the full training fold. The product-state ablation removes the CNOT blocks. The noisy QSVM applies a depolarising channel (p = 0.01) to every qubit acted on by every gate (density-matrix simulation) and uses as the kernel, re-tuning and ; a finite-shot arm additionally estimates every kernel entry from 1,024 shots and projects the training Gram matrix onto the positive semidefinite cone. Shots were modelled as binomial draws with success probability equal to the exact kernel value; this is exact for the noiseless compute-uncompute estimator but only approximate for the noisy kernel, and two-qubit gates received independent single-qubit channels rather than a two-qubit channel. Because global depolarising noise maps the kernel to a , which an SVM with a bias term and re-tuned C largely absorbs, exact noisy kernels are expected to change AUROC little; finite-shot estimation is the more demanding test [20]. A noise sweep (p = 0–0.1) used the first seed's folds at the bandwidth and C selected for the noiseless QSVM, as did a shot sweep.
The VQC applies AngleEmbedding (Rx) and 3 StronglyEntanglingLayers [34,51,52], reads out on all qubits through a trainable linear layer, and was trained by full-batch Adam (learning rate 0.05, 100 epochs, cross-entropy); its number of layers and learning rate were tuned by 3-fold inner cross-validation over , as for the QSVM, and the fixed configuration (3 layers, learning rate 0.05) is reported as a sensitivity analysis. Its ablation replaces the entangling layers with single-qubit rotations; with all-qubit readout this removes entanglement only.
To quantify implementation sensitivity we re-ran the QSVM with three cumulative configuration faults, all present in an earlier version of our own pipeline and plausible elsewhere: bandwidth fixed at 1; plus unscaled principal components as circuit inputs; plus a CZ–Rz–CZ entangling block, which equals a single-qubit Rz because diagonal gates commute, so the circuit creates no entanglement. We also ran a widely used tutorial-style configuration, with inputs min-max scaled to on each training fold and no bandwidth. A qubit-scaling experiment (4, 8 and 12 qubits; first-seed folds) on TCGA-BRCA and breast cancer compared the QSVM with an RBF SVM on the same components and tracked kernel concentration at bandwidth 1.
4.3 Statistical analysis
Five seeds 5-fold stratified cross-validation gave 25 outer splits per dataset, identical for every model, so all comparisons are paired. The primary metric is the area under the receiver operating characteristic curve (AUROC). Because overlapping training sets make the 25 differences dependent, we used the corrected resampled t-test (variance inflated by ) [41,42] and, for parity claims, two one-sided tests (TOST) [43,44] with the same variance at margins of , and AUROC. Within each comparison family, p-values across the six datasets were Holm-adjusted [53]. A comparison is Equivalent at a margin if its adjusted TOST p < 0.05, Worse or Better if its adjusted t-test p < 0.05, and otherwise Inconclusive. To summarise across datasets, the per-dataset differences and their corrected standard errors were pooled with a random-effects model (DerSimonian-Laird heterogeneity; Hartung-Knapp-Sidik-Jonkman confidence interval with k - 1 degrees of freedom) [54,55], and pooled equivalence was declared when the 90% confidence interval lay inside the margin. With six datasets these pooled estimates summarise the datasets studied rather than all clinical prediction tasks. The primary QSVM comparison is with the RBF SVM, which differs only in the kernel and, like the QSVM, was scored by its decision function; comparisons with the best classical model per dataset (selected post hoc, which favours the classical side) and for the VQC are secondary. Accuracy, macro-F1, balanced accuracy and the Matthews correlation coefficient (MCC) are reported in Supplementary Table S4; thresholds differ between models (probability 0.5 versus decision-function sign), so these are descriptive only.
The analysis was not pre-registered, and parts of it were revised after an initial analysis of an earlier version of the pipeline (Supplementary Table S8). The margin was specified before any results were seen. The and margins, the designation of the RBF SVM as the primary comparator, and the finite-shot, all-predictor, implementation-sensitivity and qubit-scaling analyses were added afterwards. All margins are conventional rather than clinically derived, and all comparisons that were run are reported. Because this is a methodological benchmark rather than the development of a clinical prediction tool, we do not claim TRIPOD+AI compliance; the items it covers that apply here (data sources, outcome and predictor definitions, missing data, validation design and performance measures) are reported in Sections 4.1–4.3. A complete independent re-run of the benchmark reproduced every per-split AUROC exactly except those of SVMs scored with Platt-scaled probabilities, which rely on an internal random split and differed by at most 0.001 per split; this is why the kernel-matched comparison scores the RBF SVM by its decision function.
4.4 Kernel and data-complexity analysis
On a stratified sample of up to 300 observations we computed the maximum per-feature Fisher ratio, 1-nearest-neighbour label agreement, centred kernel-target alignment [40] for the quantum, product-state and RBF kernels, and the geometric difference [31] from trace-normalised kernels with regularisation (and to as a sensitivity analysis), together with the centred alignment between the quantum kernel and the best-matching RBF kernel. is used as a reference scale: Huang et al. relate a potential advantage to g approaching , but g is not bounded by under regularisation. Provable speed-ups in supervised learning require data-access assumptions that clinical datasets do not satisfy [38].
5. Results
We first report discrimination for all models on identical four-component inputs (5.1), then the paired and pooled comparisons with equivalence tests (5.2), which form the primary analysis: the QSVM against the kernel-matched RBF SVM, with comparisons against the best classical model and the VQC as secondary. We then examine whether entanglement matters (5.3), how noise and finite shots affect the QSVM (5.4), and the kernel regime and data complexity that explain the results (5.5). The remaining subsections report implementation sensitivity (5.6), the effect of dimensionality reduction (5.7), computational cost (5.8) and the measured effect behind each QML-Health-READY domain (5.9).
5.1 Discrimination
Discrimination varied widely across datasets (Table 3; Figure 1). The best classical model reached AUROC 0.736 (Heart Failure) to 0.994 (Breast Cancer Wisconsin), and no single classical model was best everywhere (SVM (RBF) on 3; logistic regression on 2; SVM (polynomial) on 1). The noiseless QSVM ranged from 0.700 to 0.990 and tracked the classical models closely on every dataset except NHANES 2017–18. Among four-component models, a quantum variant had the highest mean AUROC on Pima Indians Diabetes and NHANES 2017–18 (QSVM (product-state kernel), VQC), but by at most 0.001 AUROC over the best classical model, far inside the confidence intervals.
Table 3. AUROC, mean ± 95% CI over 25 paired splits (CIs treat splits as independent and are therefore optimistic). Bold: highest mean per dataset among four-component models. The last row gives the best classical model on all predictors.
| Model | Breast Cancer Wisconsin | Heart Disease Cleveland | Pima Indians Diabetes | Heart Failure | TCGA-BRCA | NHANES 2017–18 |
|---|---|---|---|---|---|---|
| Logistic regression | 0.993 ± 0.002 | 0.898 ± 0.022 | 0.815 ± 0.013 | 0.710 ± 0.029 | 0.954 ± 0.009 | 0.777 ± 0.012 |
| SVM (RBF) | 0.994 ± 0.002 | 0.892 ± 0.022 | 0.820 ± 0.013 | 0.736 ± 0.028 | 0.952 ± 0.010 | 0.731 ± 0.015 |
| SVM (polynomial) | 0.993 ± 0.004 | 0.889 ± 0.022 | 0.817 ± 0.014 | 0.712 ± 0.019 | 0.958 ± 0.008 | 0.712 ± 0.020 |
| Random forest | 0.985 ± 0.004 | 0.880 ± 0.023 | 0.812 ± 0.014 | 0.709 ± 0.027 | 0.946 ± 0.011 | 0.773 ± 0.012 |
| Gradient boosting | 0.985 ± 0.004 | 0.870 ± 0.022 | 0.812 ± 0.014 | 0.664 ± 0.025 | 0.944 ± 0.008 | 0.770 ± 0.012 |
| QSVM | 0.990 ± 0.003 | 0.884 ± 0.024 | 0.807 ± 0.014 | 0.708 ± 0.028 | 0.956 ± 0.010 | 0.700 ± 0.016 |
| QSVM (noisy, p = 0.01) | 0.987 ± 0.003 | 0.878 ± 0.024 | 0.804 ± 0.014 | 0.710 ± 0.032 | 0.956 ± 0.010 | 0.704 ± 0.017 |
| QSVM (noisy + 1,024 shots) | 0.942 ± 0.008 | 0.808 ± 0.040 | 0.738 ± 0.021 | 0.630 ± 0.031 | 0.918 ± 0.015 | 0.611 ± 0.011 |
| QSVM (product-state kernel) | 0.993 ± 0.002 | 0.897 ± 0.023 | 0.821 ± 0.013 | 0.735 ± 0.026 | 0.953 ± 0.010 | 0.728 ± 0.018 |
| VQC | 0.991 ± 0.002 | 0.873 ± 0.022 | 0.809 ± 0.013 | 0.686 ± 0.027 | 0.954 ± 0.010 | 0.778 ± 0.013 |
| VQC (no entanglement) | 0.988 ± 0.004 | 0.883 ± 0.024 | 0.810 ± 0.013 | 0.727 ± 0.027 | 0.953 ± 0.010 | 0.772 ± 0.013 |
| VQC (tuned) | 0.991 ± 0.002 | 0.872 ± 0.022 | 0.807 ± 0.013 | 0.682 ± 0.026 | 0.955 ± 0.010 | 0.777 ± 0.012 |
| SVM (RBF), decision-function score | 0.994 ± 0.002 | 0.892 ± 0.022 | 0.820 ± 0.013 | 0.736 ± 0.028 | 0.952 ± 0.009 | 0.731 ± 0.015 |
| Best classical, all predictors | 0.996 (SVM (polynomial)) | 0.901 (Random forest) | 0.845 (SVM (polynomial)) | 0.781 (Random forest) | 0.961 (Random forest) | 0.787 (Random forest) |

Figure 1. AUROC (mean ± 95% CI, 25 splits) for classical (blue) and quantum (red) models on identical four-component inputs. Dashed line: best classical model on all predictors.
5.2 Paired comparisons and equivalence
Table 4. Paired AUROC differences (quantum-classical) with corrected 95% CIs, Holm-adjusted p-values for the corrected t-test and for equivalence (TOST) at ±0.02 and ±0.05, and verdicts at each margin (E = equivalent, I = inconclusive, W = worse, B = better).
| Dataset | Comparison | Δ AUROC [95% CI] | p(t) | p(TOST ±0.02) | p(TOST ±0.05) | Verdict ±0.02 / ±0.05 |
|---|---|---|---|---|---|---|
| Breast Cancer Wisconsin | QSVM-SVM (RBF) | -0.004 [-0.011, +0.003] | 0.923 | <0.001 | <0.001 | E / E |
| Breast Cancer Wisconsin | QSVM-best (SVM (RBF)) | -0.004 [-0.011, +0.003] | 0.569 | <0.001 | <0.001 | E / E |
| Breast Cancer Wisconsin | VQC (tuned)-best (SVM (RBF)) | -0.003 [-0.006, +0.001] | 0.473 | <0.001 | <0.001 | E / E |
| Heart Disease Cleveland | QSVM-SVM (RBF) | -0.007 [-0.034, +0.019] | 1.000 | 0.658 | 0.004 | I / E |
| Heart Disease Cleveland | QSVM - best (Logistic regression) | -0.013 [-0.034, +0.007] | 0.569 | 0.750 | 0.002 | I / E |
| Heart Disease Cleveland | VQC (tuned) - best (Logistic regression) | -0.026 [-0.047, -0.004] | 0.136 | 1.000 | 0.029 | I / E |
| Pima Indians Diabetes | QSVM - SVM (RBF) | -0.012 [-0.029, +0.004] | 0.626 | 0.658 | <0.001 | I / E |
| Pima Indians Diabetes | QSVM - best (SVM (RBF)) | -0.012 [-0.029, +0.004] | 0.499 | 0.693 | <0.001 | I / E |
| Pima Indians Diabetes | VQC (tuned) - best (SVM (RBF)) | -0.013 [-0.029, +0.003] | 0.473 | 0.526 | <0.001 | I / E |
| Heart Failure | QSVM - SVM (RBF) | -0.027 [-0.054, -0.001] | 0.259 | 1.000 | 0.087 | I / I |
| Dataset | Comparison | Δ AUROC [95% CI] | p(t) | p(TOST ±0.02) | p(TOST ±0.05) | Verdict ±0.02 / ±0.05 |
|---|---|---|---|---|---|---|
| Heart Failure | QSVM - best (SVM (RBF)) | -0.027 [-0.054, -0.001] | 0.213 | 1.000 | 0.087 | I / I |
| Heart Failure | VQC (tuned) - best (SVM (RBF)) | -0.053 [-0.110, +0.003] | 0.323 | 1.000 | 0.546 | I / I |
| TCGA-BRCA | QSVM - SVM (RBF) | +0.004 [-0.008, +0.016] | 1.000 | 0.031 | <0.001 | E / E |
| TCGA-BRCA | QSVM - best (SVM (polynomial)) | -0.002 [-0.014, +0.011] | 0.777 | 0.016 | <0.001 | E / E |
| TCGA-BRCA | VQC (tuned) - best (SVM (polynomial)) | -0.003 [-0.016, +0.010] | 1.000 | 0.027 | <0.001 | E / E |
| NHANES 2017-18 | QSVM - SVM (RBF) | -0.031 [-0.083, +0.021] | 0.923 | 1.000 | 0.229 | I / I |
| NHANES 2017-18 | QSVM - best (Logistic regression) | -0.076 [-0.121, -0.031] | 0.011 | 1.000 | 0.880 | W / W |
| NHANES 2017-18 | VQC (tuned) - best (Logistic regression) | +0.001 [-0.018, +0.019] | 1.000 | 0.089 | <0.001 | I / E |
No quantum model was significantly better than a classical comparator, and the quantum point estimate exceeded the classical one in only 1 of 12 secondary comparisons. Against the kernel-matched RBF SVM, the QSVM was equivalent within ±0.05 on 4 datasets (Breast Cancer Wisconsin, Heart Disease Cleveland, Pima Indians Diabetes and TCGA-BRCA) and within ±0.02 on 2 (Breast Cancer Wisconsin and TCGA-BRCA), and was not significantly worse on any dataset. Against the best classical model, the QSVM was equivalent within ±0.05 on 4 and within ±0.02 on 2 datasets and significantly worse on NHANES 2017-18; the VQC was equivalent to the best classical model on 5 datasets at ±0.05 and on 2 at ±0.02. Equivalence within ±0.01 held in only 1 of the 18 comparisons. Dataset by dataset, parity therefore holds at the conventional ±0.05 margin but is rarely established at tighter margins.
Pooled across the six datasets (Figure 2, bottom rows), the QSVM differed from the kernel-matched RBF SVM by -0.006 AUROC (95% CI -0.017 to +0.004; τ = 0.005, I² = 32%), equivalent within ±0.02. Its pooled difference from the best classical model was -0.013 AUROC (95% CI -0.033 to +0.006; τ = 0.011, I² = 67%), equivalent within ±0.05 but not ±0.02, and the tuned VQC differed from the best classical model by -0.007 AUROC (95% CI -0.019 to +0.004; τ = 0.006, I² = 48%), equivalent within ±0.02. No pooled difference significantly favoured a quantum model, and every pooled point estimate was negative.
Tuning the VQC changed its AUROC by -0.003 to +0.001 relative to the fixed configuration. The fixed-configuration VQC was equivalent to the best classical model within ±0.05 on 5 of 6 datasets, against 5 for the tuned VQC, so the VQC conclusions do not depend on tuning.
The largest deficit against the best classical model, on NHANES 2017-18 (-0.076), shrank to -0.031 and was not significant against the RBF SVM. Every SVM performed poorly on this dataset relative to logistic regression, so the deficit appears to reflect the learner more than the quantum kernel.

Figure 2. Paired AUROC differences with corrected 95% CIs for each dataset; diamonds show random-effects pooled estimates with Hartung-Knapp 95% CIs. Shaded bands: ±0.02 and ±0.05 equivalence margins.
5.3 Entanglement and the product-state kernel
Removing entanglement did not significantly change QSVM AUROC on any dataset; the product-state kernel had the higher or equal point estimate on 5 of 6. This kernel is a product of single-qubit overlaps and is trivially computed classically, yet it came within 0.01 AUROC of the best classical model on 5 of 6 datasets (Breast Cancer Wisconsin, Heart Disease Cleveland, Pima Indians Diabetes, Heart Failure and TCGA-BRCA). The QSVM's performance on these data therefore did not depend on entanglement. With all-qubit readout, removing entanglement from the VQC did not significantly reduce AUROC on any dataset, and the unentangled VQC had the higher or equal point estimate on 3 of 6. Details are in Supplementary Table S2.
5.4 Noise and finite shots
Depolarising noise at p = 0.01 changed QSVM AUROC by at most 0.007 (not significant on any dataset), as expected from the near-affine effect of depolarising noise on the kernel. Larger noise reduced AUROC by up to 0.131 at p = 0.1 (NHANES 2017–18) (Figure 3A). With 1,024 shots per kernel entry on top of p = 0.01 noise, the QSVM changed by -0.090 to -0.038 AUROC relative to the noiseless QSVM, and was equivalent to the best classical model within ±0.05 on none of the six datasets (Figure 3B shows the shot sweep).

Figure 3. Change in QSVM AUROC relative to the noiseless kernel (first-seed folds, bandwidth and C fixed at the noiseless selection). A: per-gate depolarising probability. B: shots per kernel entry.
5.5 Kernel regime and data complexity
Inner cross-validation chose the grid minimum (0.005) in 7% of QSVM fits, a bandwidth of 0.02 or less in 41%, and never 0.5 or more. At the modal bandwidth (0.05) the quantum kernel had lower alignment with the labels than the RBF kernel on all six datasets, with the lowest alignment on Heart Failure; the geometric difference was 2.42–4.15 at , small relative to the reference scale (17.2–17.3), and the quantum kernel's centred alignment with the best-matching RBF kernel was 0.75–0.82 (Figure 4; Supplementary Table S3). Alignment and g were computed at the modal bandwidth and a fixed RBF of 1/4, not at each fold's selected settings, so they are descriptive. The tuned quantum kernels thus operated in the smooth, small-bandwidth regime in which they approximate classical kernels [22,23], which is consistent with parity and indicates that a classical kernel can match the quantum one on these data [31].
Increasing the number of qubits reproduced exponential concentration of the untuned kernel [20]: Breast Cancer Wisconsin: off-diagonal kernel variance at bandwidth 1 fell from (4 qubits) to (12 qubits), and tuned QSVM AUROC was 0.989 versus 0.994 for the RBF SVM at 12 qubits; TCGA-BRCA: off-diagonal kernel variance at bandwidth 1 fell from (4 qubits) to (12 qubits), and tuned QSVM AUROC was 0.954 versus 0.954 for the RBF SVM at 12 qubits (Supplementary Figure S2).

Figure 4. A: centred kernel-target alignment. B: geometric difference ( ) with the reference scale (not an upper bound).
5.6 Implementation sensitivity
Fixing the bandwidth at 1 reduced QSVM AUROC from 0.70–0.99 to 0.48–0.59; adding unscaled inputs and the non-entangling CZ–Rz–CZ block left it at 0.48–0.52 (Figure 5). The tutorial-style configuration (min–max scaling to , no bandwidth) was less extreme but still poor, at 0.56–0.89, between 0.02 and 0.24 AUROC below the tuned QSVM on every dataset. A study using the faulty settings would conclude that quantum models fail, and one using the tutorial-style settings that they lag behind classical models on most datasets, whereas the corrected pipeline gives the results in Table 3; the difference comes from implementation, not from quantum computing, which is why the Encoding and Robustness domains of QML-Health-READY are Core items.

Figure 5. QSVM AUROC under cumulative implementation faults (mean ± 95% CI, 25 splits). Dotted line: chance.
5.7 Effect of dimensionality reduction
Classical models on all predictors changed AUROC by +0.002 to +0.046 relative to four components (not significant on any dataset after Holm adjustment). Against the best all-predictor model, the QSVM was equivalent within ±0.05 on 2 of 6 datasets.
5.8 Computational cost
Per outer split, including tuning, the noiseless QSVM took 0.7–4.2 s and the noisy QSVM 18–140 s of simulation, versus 0.11–0.25 s for logistic regression. Simulation time understates hardware cost: bandwidth tuning on one outer split requires 339,673–15,366,400 distinct kernel-entry circuits (|grid| × [n(n+1)/2 training + n_test · n test entries]), each executed for hundreds to thousands of shots, whereas every classical model fits in seconds.
5.9 Empirical support for the framework domains
Each QML-Health-READY domain corresponds to an effect measured in this study, and several were large enough to change a conclusion (Table 5). The heart-failure comparison is a clean test of the leakage-audit item: version 2 of our pipeline (Supplementary Table S8) used the same splits and models but kept follow-up time as a predictor, and every classical model scored 0.09–0.12 AUROC higher than in the reported analysis. These observations support the framework's items; they do not replace the consensus and inter-rater validation that a reporting guideline requires.
Table 5. Effects measured in this study that each QML-Health-READY domain would detect.
| Domain | Item tested | Measured effect in this study |
|---|---|---|
| R† Rationale | Data-complexity analysis | Geometric difference 2.4–4.2 against a scale of ≈17, and lower quantum than RBF kernel-target alignment on all six datasets: no data-driven advantage was expected, and none was seen. |
| E† Encoding | Bandwidth tuning and input scaling | Fixing the bandwidth at 1 lowered QSVM AUROC by 0.18–0.45, to near chance. |
| A† Algorithm & baselines | Kernel-matched comparator; entanglement ablation | The NHANES deficit was -0.076 against the best classical model but -0.031 (not significant) against the RBF SVM; the product-state kernel matched the entangling one. |
| D† Data & splits | Leakage audit (post-baseline predictors) | Including heart-failure follow-up time inflated classical AUROC by 0.09–0.12. |
| Y† Yield | Pre-specified equivalence margin | QSVM–RBF SVM equivalence held on 4 of 6 datasets at ±0.05 but 2 at ±0.02 and 0 at ±0.01. |
| R† Robustness | Explicit noise and finite shots | Exact depolarising noise (p = 0.01) changed AUROC by at most 0.007; 1,024 shots lowered it by a pooled 0.054. |
| Domain | Item tested | Measured effect in this study |
|---|---|---|
| E Evaluation in context | Threshold-dependent metrics | On NHANES the QSVM reached AUROC 0.70 but MCC 0.002 and balanced accuracy 0.50: at its default threshold it predicted almost only the majority class. |
| Y Yardstick for cost | Circuit executions per fit | 0.34–15.4 million kernel-entry circuits per tuned outer split, each repeated for many shots. |
6. Discussion
The study explored if quantum classifiers predicted clinical outcomes any better given the identical inputs, splits and tuning budgets as conventional models. They didn't. In six datasets, well-constructed quantum models were competitive with tuned classical models to within a standard margin but were never better and lost that competitive edge when kernel entries were calculated from a reasonable number of measurements.
Principal finding: In a matched, paired design, correctly configured quantum classifiers approached tuned classical models but did not exceed them, and parity was supported only at the conventional ±0.05 margin. Three observations are consistent with this. First, inner cross-validation drove the quantum kernel to small bandwidths, where it behaves like an RBF or low-order polynomial kernel [22,23]. Second, the classically trivial product-state kernel performed as well as the entangling kernel. Third, the geometric difference was small, so Huang et al.'s necessary condition for a data-driven advantage was not met [31].
Relation to previous work: Our results agree with recent independent benchmarks: Kakavand et al. found no significant advantage in 29 comparisons and quantum-kernel spectra that were too flat or too concentrated, with the one competitive configuration costing about 2,000 times more computation [15]; Leither et al. found no advantage on oncological data [16]; and Schnabel and Roth showed, across more than 20,000 quantum-kernel models, how strongly hyperparameters drive performance [33]. Several of our mechanistic findings were anticipated by theory or by benchmarks outside medicine: the classical character of bandwidth-tuned kernels [23], exponential concentration [20] and the shot cost of kernel estimation [24]. What this study adds is their confirmation on clinical data under a matched, equivalence-tested design; a kernel-matched comparison showing that apparent quantum deficits can belong to the learner rather than the kernel; a measured shot penalty and its interaction with bandwidth tuning; and an experiment showing how far configuration faults alone move the conclusion.
Measurement cost: Finite-shot estimation, not depolarising noise, was the binding constraint. Exact noise at p = 0.01 changed AUROC by at most 0.007, whereas adding 1,024 shots per kernel entry lowered it by 0.038–0.090. The penalty in the shot sweep was largest on the datasets whose tuned kernels were most compressed (Heart Failure, NHANES 2017–18 and Pima Indians Diabetes; off-diagonal standard deviation 0.005–0.070), where, at the bandwidth selected without shot noise, even 8,192 shots left AUROC 0.05–0.07 below the noiseless value. When bandwidth was re-tuned under shots, as in the main finite-shot arm, inner cross-validation chose a larger bandwidth than in the noiseless case in 75% of fits, recovering part of the loss. This is consistent with a trade-off between bandwidth and measurement cost: the small bandwidths that help quantum kernels generalise leave differences between kernel entries that finite sampling must resolve [20,22,24]. Exact state-vector simulation hides this cost, so finite-shot evaluation belongs in the Robustness domain of any QML benchmark.
Comparator choice and implementation sensitivity: The comparison with the kernel-matched RBF SVM matters. Against the best of five classical models, a quantum kernel can appear inferior because SVMs as a class are unsuited to a dataset, as on NHANES 2017–18, where logistic regression and both tree ensembles beat every SVM. We recommend that QSVM studies report both comparisons. The implementation-sensitivity experiment shows that an untuned bandwidth or unscaled inputs alone produce near-chance results, so published reports of quantum models failing should be read with the encoding and bandwidth in mind. Because configuration choices also determine which classical comparators look strong, the same caution applies to reported successes.
Scope and clinical implications: These conclusions apply to 4-qubit simulations of small, public tabular datasets (with a 12-qubit check on two datasets). They say nothing about barren plateaus, which such small circuits cannot exhibit [35,37], or about fault-tolerant devices. Where quantum methods may help is summarised in Supplementary Table S7 and Figure S1: molecular simulation is the most plausible long-term application, high-dimensional omics a possible one requiring per-dataset complexity analysis, and routine tabular risk prediction and imaging unlikely beneficiaries in the NISQ era. Clinical use of any QML model would also be subject to the principles of trustworthy healthcare AI [27] and to medical-device regulation, and quantum infrastructure is concentrated in a few high-income settings.
Recommendations and future: Authors should give quantum and classical models identical inputs, splits and tuning budgets; report a kernel-matched classical comparator; report and check bandwidth selection; verify that noise channels are active and model finite shots; use split-corrected paired tests with equivalence margins; and complete the QML-Health-READY checklist. Reviewers should request it, and funders should prioritise multi-site and molecular-simulation studies over further single-dataset classification.
Four extensions would test how far these findings generalise. The first is evaluation on quantum hardware with calibrated noise and error mitigation, where shot budgets are real rather than simulated. The second is a larger collection of clinical datasets, including electronic health record cohorts with external validation, which would allow cross-dataset inference rather than per-dataset tests. The third is higher-dimensional omics data with more qubits, the setting our triage rates as most plausible for a data-driven advantage. The fourth is validation of QML-Health-READY itself, through a Delphi consensus process and independent dual-rater application to published studies.
7. Limitations
All quantum results come from classical simulation of 4-qubit circuits (12 qubits in a secondary experiment). Noise was generic depolarising noise with a binomial shot model that is exact only for the noiseless estimator, and the noise, shot and qubit-scaling sweeps used the first seed's folds only; hardware-calibrated noise, readout error and real hardware were not studied. The analysis was not pre-registered, and several analyses were added after an initial analysis of an earlier pipeline. Equivalence margins are conventional rather than clinically derived, the best classical model was selected post hoc, and single-model confidence intervals treat dependent splits as independent. Restricting every model to four principal components ensures a matched comparison but is clinically artificial, although all-predictor classical results are reported for context.
The datasets are small public sets without external validation, calibration or decision-curve analysis, and NHANES survey weights were not applied. The VQC used one initialisation per split and a small tuning grid (four configurations), and its entanglement ablation used the fixed configuration. The bandwidth grid was searched down to 0.005; 7% of fits chose the minimum, so for those fits the optimum may lie below the grid. Finally, the literature synthesis relies on published reviews and benchmarks rather than a new systematic search, and QML-Health-READY has not been validated for inter-rater reliability, so a Delphi process and pilot application to published studies are needed. These limitations mean the findings should be read as evidence about small, simulated, tabular clinical settings, not as a verdict on quantum machine learning in medicine. The above limitations indicate that the results should be interpreted as insights pertaining to minor, simulated, tabular clinical environments, rather than as a conclusive judgment on the application of quantum machine learning in healthcare.
8. Conclusion
On six clinical datasets, correctly configured quantum classifiers matched tuned classical models within a conventional margin but never outperformed them, and their performance did not depend on entanglement. Their main practical cost was measurement: estimating kernel entries from a realistic number of shots erased the parity seen in exact simulation. Implementation choices, not quantum effects, determined whether they appeared to fail or to succeed. QML-Health-READY sets out the reporting needed to tell these apart.
Future QML studies in health should report matched inputs, a kernel-matched classical comparator, finite-shot estimation and equivalence-tested results, and validation on quantum hardware and larger clinical cohorts is the necessary next step.
Declarations
Declaration of competing interest: The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
Data availability: All datasets used in this study are publicly available: UCI Machine Learning Repository (archive.ics.uci.edu), UCSC Xena (xenabrowser.net), and CDC NHANES (www.n.cdc.gov/Nchs/Data/Nhanes/).
Code availability: The source code and per-split experimental results supporting this study are publicly available on GitHub at https://github.com/sirajbb/qml-health-ready. An archived version (v3.0.0) is available through Zenodo at https://doi.org/10.5281/zenodo.23572398.
Disclosure of Using AI Tools: During the preparation of this work the authors used Claude (Anthropic) to assist with code development, code review and drafting of the manuscript. After using this tool, the authors reviewed and edited the content as needed and take full responsibility for the content of the published article.
Ethics statement: Only public, de-identified data were used; ethics approval was not required.
Acknowledgements: N/A.
Funding: N/A.
References
-
Topol EJ. High-performance medicine: the convergence of human and artificial intelligence. Nat Med. 2019;25(1):44-56. doi:10.1038/s41591-018-0300-7.
-
Obermeyer Z, Emanuel EJ. Predicting the future — big data, machine learning, and clinical medicine. N Engl J Med. 2016;375(13):1216-1219. doi:10.1056/NEJMp1606181.
-
Preskill J. Quantum computing in the NISQ era and beyond. Quantum. 2018;2:79. doi:10.22331/q-2018-08-06-79.
-
Havlíček V, Córcoles AD, Temme K, Harrow AW, Kandala A, Chow JM, Gambetta JM. Supervised learning with quantum-enhanced feature spaces. Nature. 2019;567(7747):209-212. doi:10.1038/s41586-019-0980-2.
-
Schuld M, Killoran N. Quantum machine learning in feature Hilbert spaces. Phys Rev Lett. 2019;122(4):040504. doi:10.1103/PhysRevLett.122.040504.
-
Schuld M, Petruccione F. Machine Learning with Quantum Computers. 2nd ed. Cham: Springer; 2021. doi:10.1007/978-3-030-83098-4.
-
Rebentrost P, Mohseni M, Lloyd S. Quantum support vector machine for big data classification. Phys Rev Lett. 2014;113(13):130503. doi:10.1103/PhysRevLett.113.130503.
-
Biamonte J, Wittek P, Pancotti N, Rebentrost P, Wiebe N, Lloyd S. Quantum machine learning. Nature. 2017;549(7671):195-202. doi:10.1038/nature23474.
-
Ciliberto C, Herbster M, Ialongo AD, Pontil M, Rocchetto A, Severini S, Wossnig L. Quantum machine learning: a classical perspective. Proc R Soc A. 2018;474(2209):20170551. doi:10.1098/rspa.2017.0551.
-
Gupta RS, Wood CE, Engstrom T, Pole JD, Shrapnel S. A systematic review of quantum machine learning for digital health. npj Digit Med. 2025;8:237. doi:10.1038/s41746-025-01597-z.
-
Bowles J, Ahmed S, Schuld M. Better than classical? The subtle art of benchmarking quantum machine learning models. arXiv preprint arXiv:2403.07059. 2024. doi:10.48550/arXiv.2403.07059.
-
Dunjko V, Briegel HJ. Machine learning & artificial intelligence in the quantum domain: a review and a roadmap. Rep Prog Phys. 2018;81(7):074001. doi:10.1088/1361-6633/aab406.
-
Tang E. A quantum-inspired classical algorithm for recommendation systems. In: Proc 51st Annual ACM Symposium on Theory of Computing (STOC 2019). New York: ACM; 2019. p. 217-228. doi:10.1145/3313276.3316310.
-
Sahebi M, Barthe A, Suzuki Y, Holmes Z, Grossi M. On dequantization of supervised quantum machine learning via random Fourier features. arXiv preprint arXiv:2505.15902. 2025. doi:10.48550/arXiv.2505.15902.
-
Kakavand S, Strohmeyer C, Schlotter M. Benchmarking quantum kernel support vector machines against classical baselines on tabular data: a rigorous empirical study with hardware validation. arXiv preprint arXiv:2604.18837. 2026. doi:10.48550/arXiv.2604.18837.
-
Leither S, Lubinski T, Kubal M, Johri S. Benchmarking quantum and classical machine learning models on oncological data. arXiv preprint arXiv:2608.11373. 2026. doi:10.48550/arXiv.2608.11373.
-
Liu H, Zhang Z, Zheng K, Liang Z, Chen CS, Carothers C, Hahn J. Quantum machine learning for biomedical classification problems: a feasibility study on real quantum hardware. Ann Biomed Eng. 2026. doi:10.1007/s10439-026-04204-8.
-
Priyadharshini M, Raju BD, Banu AF, Kumar PJ, Murugesh V, Rybin O. A quantum machine learning framework for predicting drug sensitivity in multiple myeloma using proteomic data. Sci Rep. 2025;15(1):26553. doi:10.1038/s41598-025-06544-2.
-
Setiawan AE, Rustad S, Syukur A, Soeleman MA, Shidik GF, Mahargya IL, et al. A systematic literature review of quantum machine learning for medical: trends, datasets, topics, and methods. Int J Cogn Comput Eng. 2026;7:609-630. doi:10.1016/j.ijcce.2026.05.002.
-
Thanasilp S, Wang S, Cerezo M, Holmes Z. Exponential concentration in quantum kernel methods. Nat Commun. 2024;15:5200. doi:10.1038/s41467-024-49287-w.
-
Shaydulin R, Wild SM. Importance of kernel bandwidth in quantum machine learning. Phys Rev A. 2022;106(4):042407. doi:10.1103/PhysRevA.106.042407.
-
Canatar A, Peters E, Pehlevan C, Wild SM, Shaydulin R. Bandwidth enables generalization in quantum kernel models. Trans Mach Learn Res. 2023. arXiv:2206.06686.
-
Flórez-Ablan R, Roth M, Schnabel J. On the similarity of bandwidth-tuned quantum kernels and classical kernels. Quantum Sci Technol. 2025;10(3):035051. doi:10.1088/2058-9565/ade7ad.
-
Miroszewski A, Fellous Asiani M, Mielczarek J, Le Saux B, Nalepa J. In search of quantum advantage: estimating the number of shots in quantum kernel methods. arXiv preprint arXiv:2407.15776. 2024. doi:10.48550/arXiv.2407.15776.
-
Collins GS, Moons KGM, Dhiman P, Wynants L, Myint PK, Majeed A, et al. TRIPOD+AI statement: updated guidance for reporting clinical prediction models that use regression or machine learning methods. BMJ. 2024;385:e078378. doi:10.1136/bmj-2023-078378.
-
Mongan J, Moy L, Kahn CE Jr. Checklist for Artificial Intelligence in Medical Imaging (CLAIM): a guide for authors and reviewers. Radiol Artif Intell. 2020;2(2):e200029. doi:10.1148/ryai.2020200029.
-
Lekadir K, Frangi AF, Porras AR, Glocker B, Cintas C, Langlotz CP, et al. FUTURE-AI: international consensus guideline for trustworthy and deployable artificial intelligence in healthcare. BMJ. 2025;388:e081554. doi:10.1136/bmj-2024-081554.
-
Schuld M. Supervised quantum machine learning models are kernel methods. arXiv preprint arXiv:2101.11020. 2021.
-
Abbas A, Sutter D, Zoufal C, Lucchi A, Figalli A, Woerner S. The power of quantum neural networks. Nat Comput Sci. 2021;1(6):403-409. doi:10.1038/s43588-021-00084-1.
-
Schuld M, Sweke R, Meyer JJ. Effect of data encoding on the expressive power of variational quantum-machine-learning models. Phys Rev A. 2021;103(3):032430. doi:10.1103/PhysRevA.103.032430.
-
Huang HY, Broughton M, Mohseni M, Babbush R, Boixo S, Neven H, McClean JR. Power of data in quantum machine learning. Nat Commun. 2021;12(1):2631. doi:10.1038/s41467-021-22539-9.
-
Thabet S, Monbroussou L, Mamon EZ, Landman J. When quantum and classical models disagree: learning beyond minimum norm least square. npj Quantum Inf. 2026;12(1):81. doi:10.1038/s41534-026-01217-y.
-
Schnabel J, Roth M. Quantum kernel methods under scrutiny: a benchmarking study. Quantum Mach Intell. 2025;7(1):58. doi:10.1007/s42484-025-00273-5.
-
Cerezo M, Arrasmith A, Babbush R, Benjamin SC, Endo S, Fujii K, et al. Variational quantum algorithms. Nat Rev Phys. 2021;3(9):625-644. doi:10.1038/s42254-021-00348-9.
-
McClean JR, Boixo S, Smelyanskiy VN, Babbush R, Neven H. Barren plateaus in quantum neural network training landscapes. Nat Commun. 2018;9(1):4812. doi:10.1038/s41467-018-07090-4.
-
Wang S, Fontana E, Cerezo M, Sharma K, Sone A, Cincio L, Coles PJ. Noise-induced barren plateaus in variational quantum algorithms. Nat Commun. 2021;12(1):6961. doi:10.1038/s41467-021-27045-6.
-
Cerezo M, Larocca M, García-Martín D, Díaz NL, Braccia P, Fontana E, et al. Does provable absence of barren plateaus imply classical simulability? Nat Commun. 2025;16(1):7907. doi:10.1038/s41467-025-63099-6.
-
Liu Y, Arunachalam S, Temme K. A rigorous and robust quantum speed-up in supervised machine learning. Nat Phys. 2021;17(9):1013-1017. doi:10.1038/s41567-021-01287-z.
-
Kübler J, Buchholz S, Schölkopf B. The inductive bias of quantum kernels. Adv Neural Inf Process Syst. 2021;34:12661-12673.
-
Cortes C, Mohri M, Rostamizadeh A. Algorithms for learning kernels based on centered alignment. J Mach Learn Res. 2012;13:795-828.
-
Nadeau C, Bengio Y. Inference for the generalization error. Mach Learn. 2003;52(3):239-281. doi:10.1023/A:1024068626366.
-
Bouckaert RR, Frank E. Evaluating the replicability of significance tests for comparing learning algorithms. In: Advances in Knowledge Discovery and Data Mining (PAKDD 2004). Lecture Notes in Computer Science, vol 3056. Berlin: Springer; 2004. p. 3-12. doi:10.1007/978-3-540-24775-3_3.
-
Schuirmann DJ. A comparison of the two one-sided tests procedure and the power approach for assessing the equivalence of average bioavailability. J Pharmacokinet Biopharm. 1987;15(6):657-680. doi:10.1007/BF01068419.
-
Lakens D. Equivalence tests: a practical primer for t tests, correlations, and meta-analyses. Soc Psychol Personal Sci. 2017;8(4):355-362. doi:10.1177/1948550617697177.
-
Chicco D, Jurman G. Machine learning can predict survival of patients with heart failure from serum creatinine and ejection fraction alone. BMC Med Inform Decis Mak. 2020;20(1):16. doi:10.1186/s12911-020-1023-5.
-
Cancer Genome Atlas Network. Comprehensive molecular portraits of human breast tumours. Nature. 2012;490(7418):61-70. doi:10.1038/nature11412.
-
Goldman MJ, Craft B, Hastie M, Repecká K, McDade F, Kamath A, et al. Visualizing and interpreting cancer genomics data via the Xena platform. Nat Biotechnol. 2020;38(6):675-678. doi:10.1038/s41587-020-0546-8.
-
National Center for Health Statistics. National Health and Nutrition Examination Survey (NHANES) 2017-2018 Data Files. Hyattsville, MD: US Department of Health and Human Services, Centers for Disease Control and Prevention; 2019. www.cdc.gov/nchs/nhanes.
-
Pedregosa F, Varoquaux G, Gramfort A, Michel V, Thirion B, Grisel O, et al. Scikit-learn: machine learning in Python. J Mach Learn Res. 2011;12:2825-2830.
-
Bergholm V, Izaac J, Schuld M, Gogolin C, Ahmed S, Ajith V, et al. PennyLane: automatic differentiation of hybrid quantum-classical computations. arXiv preprint arXiv:1811.04968. 2018.
-
Benedetti M, Lloyd E, Sack S, Fiorentini M. Parameterized quantum circuits as machine learning models. Quantum Sci Technol. 2019;4(4):043001. doi:10.1088/2058-9565/ab4eb5.
-
Farhi E, Neven H. Classification with quantum neural networks on near term processors. arXiv preprint arXiv:1802.06002. 2018.
-
Holm S. A simple sequentially rejective multiple test procedure. Scand J Stat. 1979;6(2):65-70.
-
DerSimonian R, Laird N. Meta-analysis in clinical trials. Control Clin Trials. 1986;7(3):177-188. doi:10.1016/0197-2456(86)90046-2.
-
IntHout J, Ioannidis JPA, Borm GF. The Hartung-Knapp-Sidik-Jonkman method for random effects meta-analysis is straightforward and considerably outperforms the standard DerSimonian-Laird method. BMC Med Res Methodol. 2014;14:25. doi:10.1186/1471-2288-14-25.