Risk Control Certifies Rates, Not Magnitudes: An Audit of Selective Fetal Biometry

Zhengshuai Yang, Linna Jiang, Changyun Li, Guihu Zhao

Zhengshuai Yang¹, Linna Jiang¹, Changyun Li¹,*, and Guihu Zhao²,★

¹ College of Information and Intelligent Science and Technology, Hunan Agricultural University, Changsha 410128, China yhvguk@stu.hunau.edu.cn, 362330193@qq.com

² National Clinical Research Center for Geriatric Disorders, Xiangya Hospital, Central South University, Changsha 410008, China ghzhao@csu.edu.cn

Abstract. Prenatal ultrasound biometry must return a head circumference (HC) and refuse when the image cannot support one. Selective prediction trades coverage against error, but its finite-sample guarantees bound the rate of gross errors, not their magnitude. We audit a tool-grounded biometry pipeline on two separately pre-registered four-way splits of the 999 labelled HC18 images, retraining the segmenter three times on each. Calibrating the contour-completeness threshold by exact Clopper–Pearson risk control returns a certificate indistinguishable from a hand-set floor, yet the pipeline still emits a 271.3 mm error: a small, geometrically complete ring fitted to an image whose true HC is 324.6 mm. The accepted candidate scores 0.94 completeness, so the score cannot see the failure, and one outlier among ≈150 answers leaves the certified risk bound (α=0.10\alpha=0.10) intact. A second, untouched split reproduces the mechanism on a different image (233.3 mm). Constraining the admissibility region—the anatomical range in which the measurand is defined—removes the family instead: raising the lower bound from 50 to 55 mm costs 0.4 coverage points and cuts the worst-case error on both splits to 11.4 and 11.1 mm, whereas suppressing it through the completeness threshold costs 19.0 and 12.1 points. At an anatomically defined 70 mm the frozen tests give 1.91 and 1.81 mm MAE.

Keywords: selective prediction · distribution-free risk control · fetal ultrasound biometry · head circumference · failure-mode audit.

1 Introduction

An assistant that reports fetal head circumference (HC) from ultrasound must return a physically scaled measurement and refuse when the image cannot support one. HC, a routine indicator of fetal growth, can be estimated from a skull contour and the pixel spacing [11]; inside a vision-language model (VLM) the harder question is not how to compute the value but when it can be trusted.

  • Corresponding authors.

Z. Yang et al.

Producing a reliable numeric measurement and deciding whether to trust it are distinct challenges that expose the limitations of current VLMs. A general end-to-end VLM often struggles with precise geometric biometry; it may omit a measurement, hallucinate a scale from pure visual features, or blindly accept an incorrect external observation. Conversely, a purely geometric tool lacks semantic understanding and can return a mathematically plausible ellipse fitted to the wrong anatomical structure. Consequently, evaluating only measurement error on a selected high-quality subset does not establish reliable biometry across a full clinical cohort.

We study PUMA (Prenatal Ultrasound Multimodal Assistant), a tool-grounded VQA system that separates geometric computation, candidate selection, and anatomical verification into auditable steps. PUMA computes the measurement before generating an answer: a contour segmenter and an ellipse-fitting tool compute HC in millimetres, a completeness gate filters partial candidates, additional views are considered if the initial view fails, and the VLM verifies the accepted observation or abstains. This design exposes an interpretable selection signal, allowing us to evaluate measurement error and the proportion of answered questions—and, as we show, to measure how far a calibrated selection rule can actually be trusted.

In summary, our main contributions are: 1) We audit PUMA, a tool-grounded biometry pipeline, on a curated prenatal benchmark (Sections 3 and 6.1): against 1/96 HC answers for a direct VLM, the delivered configuration answers 66/96 at 1.76 mm MAE, and the paired benchmark with an ablation shows that the geometric gate, not the language model, is the decisive component. 2) Across two pre-registered four-way splits with three retrained seeds each, exact Clopper–Pearson calibration of the completeness threshold is indistinguishable from a hand-set floor—and remains compatible with a 271.3 mm error, because at n≈150n \approx 150 a single outlier barely moves a gross-error rate (Section 6.3). 3) We show that calibrating the anatomical admissibility region, rather than the score threshold, removes this family for 0.4 coverage points instead of 19, and confirm it with one-shot frozen-test evaluations on both splits (Section 6.3).