arXiv:2611.05925cs.CVNov 2026

Manuscript Offprint

arXiv:2611.05925

3D Banff Glomerulitis Scoring for Kidney Transplant Pathology: Feasibility Study for Volumetric Quantification

Yanfan Zhu, Junchao Zhu, Ruining Deng, Shilin Zhao, Yu Wang, Yaohong Wang, Yuechen Yang, Chongyu Qu, Zhengyi Lu, Juming Xiong, Mengmeng Yin, Yihan Wang, Andrew J. Rauch, Haichun Yang, Yuankai Huo

ABSTRACT

Quantifying glomerular inflammation in kidney-transplant biopsies is traditionally performed on single whole-slide sections using the Banff "most-severe section" rule, despite the inherently three-dimensional nature of lesion distribution. This 2D based assessment might lead to instability when inflammation varies across slices. This paper reports a feasibility study examining the technical feasibility and clinical relevance of extending Banff scoring into three dimensions. To this end, we propose a 3D Banff lesion-scoring framework that aligns serial sections, reconstructs glomerular identities across depth, and integrates inflammatory-cell counts in 3D under three scoring strategies: Compatible, Volumetric, and Deduplicated Volumetric. In the experiments, glomerulitis (g-scores) was used as an example Banff metric and applied to multi-section renal allograft biopsies. Our findings indicate that 3D Banff g-scores are more consistent across sections and, under the semi-automatic setting, the Volumetric strategy correlates more strongly with clinical biomarkers than traditional 2D scores. These results show that 3D volumetric quantification offers promising added value, underscoring the potential benefit of 3D-aware Banff scoring for kidney transplant pathology.

Keywords: Banff Classification, Kidney Transplant Pathology, Deep Learning, Digital Pathology

1. INTRODUCTION

Renal allograft biopsy is fundamental to diagnosing rejection and determining post-transplant management. The Banff Classification of Allograft Pathology provides the international standard for evaluating renal transplant biopsies, using a set of semiquantitative lesion scores—including interstitial inflammation (i), tubulitis (t), peritubular capillaritis (ptc), intimal arteritis (v), and glomerulitis (g)—to diagnose and grade rejection. 1−3^{1-3} Although a single biopsy block is routinely cut into 20–30 serial sections, each representing a slightly different tissue depth, current clinical practice assigns the g-score using only one two-dimensional (2D) histology section—the slice showing the most severe inflammation. This worst-section approach aims to avoid underestimating rejection but is inherently sensitive to sampling variation, sectioning depth, and local tissue distortion. Clinically, glomerular inflammation is a three-dimensional (3D) biological phenomenon, yet its scoring relies on a single 2D snapshot. This mismatch between disease geometry and the evaluation protocol leads to variability in diagnosis and reduces interpretability for both pathologists and clinicians. 4,5^{4,5}

Recent advances in computational pathology have produced accurate models for segmenting glomeruli 6−9^{6-9} and detecting inflammatory cells 10,11^{10,11} on whole slide images (WSIs). 12,13^{12,13} However, nearly all existing systems operate strictly in 2D: each WSI is processed independently; predictions are not aligned or reconciled across serial sections; and case-level scoring still selects the single most severe slice, replicating the clinical worst-section paradigm. 14−16^{14-16} These approaches fail to reconstruct the 3D topology of injury, do not assign consistent glomerulus identity across depth, and cannot quantify volumetric inflammatory distribution. From a clinical

Further author information: (Send correspondence to Yuankai Huo)

E-mail: yuankai.huo@vanderbilt.edu

Figure

Figure 1: 2D Banff scoring vs. 3D Banff scoring. Upper panel: the 2D Banff pipeline analyzes each section independently and assigns the final g-score based on the most severe single section. This “worst-section” rule is sensitive to sampling variability and ignores cross-section correspondence. Lower panel: the proposed 3D Banff framework aligns serial sections and integrates information across depth for volumetric g-score computation.

standpoint, this limits robustness, explainability, and trustworthiness, all essential for adoption of AI tools in routine transplant workflows.

We propose a shift from 2D slice-based evaluation to biopsy-level 3D volumetric scoring. Our framework aligns serial histology sections, reconstructs glomeruli in 3D, aggregates inflammatory-cell detections, and produces a biopsy-level Banff g-score derived from the full depth of the tissue block. This requires addressing several technical challenges: nonlinear distortions and missing sections that hinder registration; substantial variation in staining and section quality; identity tracking of glomeruli across levels; and designing an interpretable and clinically grounded method for compatible and volumetric aggregation. To overcome these challenges, we developed a unified computational pipeline that integrates robust 2D feature extraction, serial-section registration, glomerulus identity tracking, and 3D g-score computation (Figure 1). Our contributions are as follows:

  • This paper presents a feasibility study examining the technical feasibility and clinical relevance of extending Banff scoring from 2D to 3D.
  • We propose a computational framework for the quantitative measurement of the widely used Banff g-score, further extending it to 3D through the integration of AI-based section detection, glomerular segmentation, inflammatory-cell detection, and structural alignment across serial histological sections.
  • We formulate three biopsy-level 3D Banff g-scoring strategies—Compatible, Volumetric, and Deduplicated Volumetric—that capture different aspects of the 3D inflammatory distribution, and benchmark their performance against 2D Banff scoring.

References (20)