arXiv:2611.06028cs.RONov 2026

Manuscript Offprint

arXiv:2611.06028

The Effectiveness of Sliding Mode Control for Robust Vision Stabilization under the Plant-Binding Condition

Sooyeun Yang, Jongseong Brad Choi, Seung Bok choi

Sooyeun Yang1,2^{1,2}, Jongseong Brad Choi1,2,3^{1,2,3} and Seung Bok Choi1,2∗^{1,2*}

1^{1}Department of Mechanical Engineering, SUNY Korea, Incheon, Republic of Korea

2^{2}Department of Mechanical Engineering, Stony Brook University, NY, USA

3^{3}Department of Computer Science, SUNY Korea, Incheon, Republic of Korea

  • Corresponding author

Abbreviations: CI: Confidence Interval; FOV: Field of View; LOO-CV: Leave-One-Out Cross-Validation; LPF: Low-Pass Filter; OIS: Optical Image Stabilization; ORB: Oriented FAST and Rotated BRIEF; PID: Proportional–Integral-Derivative; PTZ: Pan–Tilt–Zoom; RMS: Root Mean Square; SMC: Sliding Mode Control.

Abstract: Boundary-layer Sliding Mode Control (SMC) has been applied to vision-based stabilization, but identifying its activation condition against simpler causal baselines (LPF, PID) has been elusive. The operational condition is plant binding: the disturbance velocity approaches or exceeds the actuator slew limit, so the bounded per-step actuation budget binds. We validate this in two independent vision domains: handheld translation stabilization (12 1080p clips; LPF, PID, SMC, L1L^1) and angular re-framing against a virtual slew-rate-limited pan–tilt–zoom (PTZ) plant. Outside binding, leave-one-out cross-validation makes SMC and LPF on translation statistically indistinguishable, and PID beats SMC on the angular 99th-percentile pointing offset by 5.85° (95% CI clear of zero); inside binding — reached only by sweeping the simulated slew limit, as both captured datasets land outside it — the translation gap stays a tie and SMC beats PID on the angular worst case (Cohen's dd up to +0.83). The PTZ plant's 100°/s default sits on the cross-over, which explains a small-margin PID result previously reported in the angular setting. A complementary ablation shows raising the SMC reaching gain kk costs mean tracking outside a narrow window.

Keywords: sliding mode control; video stabilization; pan–tilt–zoom control; plant saturation; boundary-layer control; activation regime.

1. INTRODUCTION

Boundary-layer Sliding Mode Control (SMC) [1], [2] is a natural candidate for vision-based stabilization: the per-frame stabilizing warp can be cast as a virtual unit-mass plant disturbed by an unknown but bounded shake signal, and the boundary-layer reaching law of Slotine and Li [2], [3] drives the sliding variable into a tunable layer in finite time. Yet across recent practical work, SMC variants have produced mixed and often negative comparisons against simpler causal baselines such as causal low-pass filtering (LPF) and PID. Our own prior single-domain experiments are no exception: handheld translation stabilization placed SMC behind LPF by 2.67 px above-cutoff residual on 11 test clips, and active angular re-framing placed SMC behind PID by 5.85° at the 99th-percentile pointing offset on a virtual PTZ plant. Both first-draft conclusions read as “SMC underperforms” without identifying the regime in which the bounded-disturbance robustness actually becomes load-bearing.

An explanation draws on three separate literatures. SMC's robustness to bounded matched disturbances is classical [1], [4], and practical deployment guides caution that the discontinuous machinery pays for itself only against a genuinely binding uncertainty [5]. Software video stabilization spans causal filtering through offline optimal-path methods [10], [11], [12], but comparisons run on an unconstrained (software-warp) actuator.

PTZ platforms carry an explicit mechanical pan–tilt rate limit [14], and the saturation literature treats bounded actuation as the central design obstacle [15], [16]. To our knowledge, the point at which that constraint activates SMC's advantage over simpler laws in a vision loop has not been isolated experimentally.

This paper resolves both negatives with a single observation. The boundary-layer machinery activates only when the disturbance velocity approaches or exceeds the actuator's slew limit — i.e. when a bounded per-step actuation budget binds against a near-binding disturbance. We call this the plant-binding regime and show across two independent vision-control domains that it is the operational activation condition for boundary-layer SMC. Fig. 1 (Sec. 2) summarizes the unified per-axis control loop in which the claim is tested.

Primary contributions. (1) An operational binding condition for boundary-layer SMC on vision-control tasks. We identify and empirically validate the binding regime: it is stated as a normalised binding ratio (Sec. 2) and verified directly by sweeping the plant slew limit through the crossing in both domains (Sec. 3.5); the sweep is simulated, and Sec. 4.3 scopes the claim accordingly. (2) Robust vision stabilization inside binding. Once the plant binds, boundary-layer SMC uses its provable insensitivity to the matched shake disturbance and to plant uncertainty to improve worst-case stabilization over PID (Cohen's dd up to +0.83) while staying at least as good on the mean. On the present simulation evidence, SMC is therefore the stronger controller inside this actuation-constrained regime; the hardware demonstration is future work. (3) A two-domain unification. The same binding condition governs SMC activation in translation stabilization and in angular re-framing against a slew-limited plant. The 100∘/s100^{\circ}/s default of the angular PTZ plant sits on the cross-over, so earlier draft comparisons that read SMC as “no better than PID” were taken at an unbinding operating point, not a structural SMC deficiency.

Supporting contributions. (4) A disclosed bandwidth Pareto for the translation σty\sigma_{ty} metric. SMC and LPF tie under leave-one-out cross-validation (+0.050 px, CI crosses zero); the residual gap at the conservative operating point c=25 is a bandwidth choice (Sec. 3.4), not an SMC deficiency. (5) A “higher gain is not free” ablation. We confirm the binding gap is closed by the plant, not by gain inflation: pushing the SMC reaching gain k from 50 to 400 over-actuates and gives no broad improvement, so the tuned boundary-layer SMC is already the right robust design.

Sec. 2 unifies the two-domain model and the boundary-layer design; Sec. 3 presents the harness, the disclosed Pareto trade-off, and the binding cross-over; Sec. 4 gives the ablations and limitations; Sec. 5 concludes.