Microdroplet Generator Surrogate Enhancement and Inverse Design Through an Uncertainty-Guided Framework

David Gabriel Harispe, Matías Gerard, Pablo A. Kler

Abstract

Microfluidic droplet generation is critical for many applications, yet efficient device design in high-dimensional parameter spaces remains computationally prohibitive due to complex multiphase flow dynamics. This work presents a unified methodology that couples adaptive surrogate enhancement with simulation-driven inverse design. High-fidelity Volume-of-Fluid simulations provide ground-truth data, while neural network ensembles predict flow regimes and droplet diameters. Ensemble-based uncertainty quantification identifies epistemic uncertainty using consensus levels for regime classification and the coefficient of variation for diameter prediction, revealing that uncertainty concentrates near regime transition boundaries where physics is highly sensitive to parameter perturbations.

A physics-informed enrichment strategy targets these critical zones and addresses class imbalances by deploying additional targeted simulations and retraining the surrogates forming the ensembles. A framework that integrates Particle Swarm Optimization for constrained inverse design, balancing accuracy with predictive confidence and physical consistency is therefore proposed. Validation on independent test datasets demonstrates that the enriched ensembles achieve higher accuracy, with the fraction of predictions within the 0–3% error range on droplet diameter nearly doubling, and high-error cases (above 10%) dropping substantially. The inverse design procedure reliably identifies physically realizable configurations meeting target droplet sizes. This approach significantly reduces computational costs while ensuring reliable predictions, offering a framework with potential applicability to the optimization of a broad range of microfluidic systems.

1 Introduction

The precise control and characterization of droplet formation in microfluidic systems are fundamental to a wide array of applications, ranging from single-cell analysis and drug delivery to the synthesis of advanced materials (Li et al., 2025; Wang et al., 2024; Wu et al., 2024). In these microscale devices, the physics of multiphase flows is governed by complex interfacial dynamics, where the viscous forces, inertial effects, and surface tension interact to produce known formation patterns, such as dripping or jetting (Sheng et al., 2022; Bourega et al., 2023).

A central challenge in modern microfluidic engineering is the ability to efficiently navigate vast design spaces and operating conditions to optimize droplet formation. While semi-empirical correlations can provide rapid means of estimating droplet and flow regime characteristics (Sontti and Atta, 2023; Mu et al., 2021; Sang et al., 2017), they often lack adaptability to new architectures and fluid properties resulting in costly and repetitive recalibration processes (Wang and Zhang, 2025; Da Ling et al., 2022; Yu et al., 2022). High-fidelity numerical simulations using Computational Fluid Dynamics (CFD) methods have been widely adopted for bypassing these empirical limitations, facilitating the study of these multi-phase systems while reducing

*Corresponding author: kler@cimec.unl.edu.ar manpower and material costs (Tsitouridou et al., 2025; Wu et al., 2023; Soroor et al., 2021). Specifically, the Volume of Fluid (VOF) approach provides high precision in capturing the interface dynamics inherent to multiphase flows (Mardani et al., 2023; da Silva and Lisboa-Filho, 2025; Yin and Kuhn, 2022; Malakshah et al., 2024). However, resolving critical phenomena like neck thinning and pinch-off demands extremely fine spatial and temporal resolutions, making extensive parameter sweeps over large design spaces computationally prohibitive.

To address this, machine learning (ML)-based surrogate modeling has emerged as an innovative tool, offering the ability to approximate complex, non-linear mappings between operational parameters (such as flow rates, viscosities, and capillary radius) and physical outputs like droplet diameter and regime types (Harispe and Kler, 2026). However, many ML models struggle to maintain accuracy in unexplored parameter regions or near regime transitions where the underlying physics becomes highly sensitive (Lu et al., 2021). A key challenge in building reliable models is distinguishing between two types of uncertainty: epistemic uncertainty, arising from limited data and model-inherent flaws, and aleatoric uncertainty, arising from the system's intrinsic, complex stochastic behavior. Without a rigorous uncertainty quantification strategy, design decisions risk relying on erroneous surrogate predictions, particularly in regions exhibiting sharp non-linearities or abrupt behavioral shifts (Hüllermeier and Waegeman, 2021).

In microfluidic applications, such inaccuracies may result in failed experimental campaigns or economic consequences, such as the inefficient use of expensive chemical or biological reagents, the propagation of critical downstream errors within the microfluidic system, and challenges in scaling these architectures for industrial production. While existing models provide valuable insights, they often lack the inherent mechanisms, like an unified error quantification or uncertainty-guided refinement, required to identify and correct inaccuracies in challenging regions before they lead to such failures (Harispe and Kler, 2024).

While recent studies have advanced individual components of such frameworks, be it adaptive surrogate enhancement, ML-assisted design, or ML-assisted predictive modeling in microfluidic devices (Bae et al., 2024; Liu et al., 2025; Solanki et al., 2022; Hong et al., 2020; Manekar et al., 2025; Lashkaripour et al., 2024, 2021), the present work introduces a unified, simulation-driven methodology. Prior works, such as (Lashkaripour et al., 2024, 2021), have achieved impressive design automation for microdroplet generators by leveraging large experimental databases. However, these approaches are inherently constrained to the parameter space and device configurations covered by prior experiments. Additionally, existing methods lack a unified framework for prediction error detection. The methodology proposed here integrates ensemble-based uncertainty quantification with physics-guided error detection, facilitating the continuous enrichment of the training dataset through targeted VOF simulations.

In this work, a fully adaptive surrogate-optimization pipeline, that is both uncertainty- and physics-guided, is proposed and validated. The pipeline is specifically tailored for computationally expensive CFD problems. Our methodology moves beyond simple statistical uncertainty estimation by employing a dual-layered approach to identify and improve predictions on regions of limited confidence.

First, ensemble learning is used to extract specific variance-based uncertainty metrics, and then, those metrics are complemented by statistical diagnostic tools. By projecting these estimates onto the operational parameter space, genuine epistemic uncertainty can be isolated from the system's intrinsic stochastic behavior. Second, our approach employs a physics-informed enrichment strategy. The decision of where to deploy additional high-fidelity VOF simulations is not driven by statistics alone, but by engineering knowledge regarding the system's operational behavior and flow regime transition boundaries, to ensure robustness where these flow regimes change (Mao et al., 2020).

The true value of this high-fidelity surrogate lies in its application to complex design problems. For many end-users, manual optimization of microfluidic devices is a daunting task because even subtle fluctuations in operational parameters can drastically alter droplet morphology. To address this, the model refinement was included into an user-oriented workflow by integrating it with a constrained optimization algorithm for reliable inverse device design. This allows for the identification of specific operational settings that yield droplets with desired physical properties while exploring the parameter space under user-defined constraints, such as fixed values or allowable ranges for fluid viscosity, velocity, and capillary radius. By leveraging neural surrogates for instantaneous evaluation, our framework can efficiently explore the parameter space under user-defined constraints, such as maintaining a strictly dripping regime while simultaneously targeting specific droplet diameter requirements. Such workflow is illustrated in Fig. 1.

The primary contribution of this work is thus a unified computational methodology that couples adaptive surrogate refinement with simulation-based optimization. This framework enables efficient, constrained, and simulation-driven design of microfluidic droplet generators while significantly reducing the computational cost

Figure

Figure 1: Schematic of the proposed optimization and inverse design framework. Operational requirements (1) are processed via an optimization algorithm to generate parametric configurations (2). Neural network ensembles evaluate these to provide feedback on droplet and flow regimes (3) to guide the optimization loop, to output eventually the operational parameters (4) for the microfluidic device. The framework also enables parameter customization (5) to achieve the target dripping regime (6).

associated with exhaustive high-fidelity simulations.

Although the methodology is demonstrated using a specific type of micro-droplet generator, its underlying principles are broadly applicable to other microfluidic systems and, more generally, to computationally intensive multiphase CFD problems. Despite variations in governing physics, geometry, or numerical solvers across applications, the same methodology can be adopted to systematically enhance surrogate fidelity and enable efficient design exploration.

The following sections present the physical characteristics and governing equations of the coaxial micro-droplet generator. The computational methodology that couples high-fidelity volume-of-fluid simulations with baseline neural network surrogates is then outlined. An adaptive surrogate enhancement pipeline is subsequently detailed, utilizing ensemble-based uncertainty quantification and physics-informed data enrichment to systematically improve predictive accuracy. Finally, the refined surrogates are applied in a constrained inverse design workflow, demonstrating the efficient identification of optimal microfluidic configurations through an optimization algorithm presented in the methodology.

References (46)