arXiv:2611.06471cs.CVNov 2026

Manuscript Offprint

arXiv:2611.06471

A 3D foundation model unifying CT interpretation and segmentation

Yulu Xie, Zilong Li, Shen Xu, Yifan Bai, Liuhong Shi, Jiao Chen, Xianglei Kong, Wenchao Zhu, Na Shen, Xianghua Ye, Yang Yan, Jiaju Zheng, Yunsong Peng, Yanzhou Su, Chaohui Yu, Hao Luo, Fan Wang

Yulu Xie¹,², Zilong Li², Shen Xu³,², Yifan Bai², Liuhong Shi⁴, Jiao Chen⁵, Xianglei Kong⁵, Wenchao Zhu⁵, Na Shen⁶, Xianghua Ye⁷, Yang Yan⁸, Jiaju Zheng⁸, Yunsong Peng⁹, Yanzhou Su², Chaohui Yu², Hao Luo²,¹⁰,¹¹,†, Fan Wang²,†

¹Department of Statistics and Data Science, Tsinghua University, Beijing, China ²Alibaba DAMO Academy, Hangzhou, China ³School of Psychological and Cognitive Sciences and Beijing Key Laboratory of Behavior and Mental Health, Peking University, Beijing, China ⁴Department of Head and Neck Surgery, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, China ⁵Department of Radiology, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, China ⁶Department of Otolaryngology-Head & Neck Surgery, Zhongshan Hospital, Fudan University, Shanghai, China ⁷Department of Radiation Oncology, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China ⁸Department of Radiology, The Affiliated Yangming Hospital of Ningbo University, Yuyao, China ⁹Guizhou Province International Science and Technology Cooperation Base for Precision Imaging Diagnosis and Treatment, Key Laboratory of Advanced Medical Imaging and Intelligent Computing of Guizhou Province, Department of Radiology, Guizhou Provincial People's Hospital, Guiyang, China ¹⁰College of Computer Science and Technology, Zhejiang University, Hangzhou, China ¹¹Hupan Laboratory, Hangzhou, China

†Corresponding authors

Radiologists interpret computed tomography (CT) scans by jointly determining what a finding represents and where it lies in three-dimensional (3D) anatomy. However, deep learning models for CT have largely treated CT interpretation and 3D segmentation as separate tasks, leaving textual findings spatially unverifiable and overlooking potential synergy between clinical understanding and spatial perception. Here we present HoloCT, a generalist 3D foundation model unifying CT interpretation and voxel-level segmentation by jointly modelling whole-volume context and fine-grained anatomical detail, performing diverse clinical tasks while providing 3D masks as evidence. To develop and evaluate HoloCT at scale, we curated HoloDATA, comprising 195,921 CT scans from 73 public datasets and six clinical cohorts, with 6.2 million instruction dialogues and 2.8 million CT-mask pairs. Across 346 tasks spanning segmentation, lesion screening, visual question answering, and report generation on 61 internal and 12 external datasets, HoloCT outperformed both specialist and foundation models. In multicentre validation across 11,455 clinical CT scans from five hospitals, HoloCT outperformed competing models in lesion segmentation and report generation by 18.2 and 15.3 points. It also achieved 85.1% mean accuracy in screening thyroid tumours and colon lesions, exceeding all four participating radiologists in a retrospective reader study. Further analyses revealed bidirectional semantic-spatial synergy: language-guided segmentation delineated unseen anatomical structures and lesions as well as diffuse free-text findings, outperforming the leading approach by 22.1 points, whereas prompting the model to generate corresponding 3D masks alongside its textual outputs significantly improved interpretation performance. In summary, HoloCT shows that clinical understanding and spatial perception can be learned together within a single foundation model and offers a path towards more accurate and reliable CT analysis.

Code: https://github.com/alibaba-damo-academy/HoloCT

DAMO TECH TO THE FUTURE

1 Introduction

Computed tomography (CT) provides rapid, high-resolution volumetric imaging for clinical screening, diagnosis, and treatment planning¹. When interpreting a scan, radiologists continuously link what a finding represents to where it lies in three-dimensional (3D) anatomy. Reliable CT interpretation requires both: textual descriptions without anatomical localization are difficult to verify across hundreds of slices, and segmented regions without clinical characterization carry limited diagnostic meaning.

Existing deep learning systems have largely developed these two capabilities in isolation. Segmentation networks delineate organs and abnormalities at the voxel level yet do not interpret their clinical significance 2−5^{2-5}. Conversely, CT vision-language models (VLMs) generate diagnostic text without providing voxel-level localization, making the anatomical basis of their predictions difficult to inspect 6−8^{6-8}. Recent grounded medical models connect language and segmentation at the output level 9−14^{9-14}; however, for 3D scans, existing models route high-resolution spatial features only to the mask decoder rather than the language model, limiting the use of fine-grained spatial information during text generation 12−14^{12-14}. Moreover, despite advances in voxel-level visual encoders 15^{15}, many of these models still rely on 2D slice encoders or coarsely downsampled 3D inputs at the expense of cross-slice continuity or fine spatial detail 12;14^{12;14}. Whether clinical understanding and spatial perception can be learned jointly within a single foundation model and mutually reinforce one another therefore remains an open question.

Here we introduce HoloCT, a generalist 3D foundation model that unifies CT interpretation and 3D segmentation by jointly modelling whole-volume context and fine-grained anatomical detail within a unified vision-language representation (Fig. 1). Specifically, HoloCT couples a dual-scale visual encoding module, a unified multimodal large language model, and a mask decoder. First, each scan is encoded through two parallel branches: a global encoder for whole-volume context and a detailed encoder that preserves fine-grained anatomical detail at standardized isotropic spacing. Second, global tokens and fine-grained spatial tokens from the two encoders are supplied directly to the language model, enabling clinical reasoning to draw on fine-grained spatial features. Third, segmentation tokens emitted by the language model guide the mask decoder for voxel-level delineation. Accordingly, a single HoloCT model performs language-guided segmentation, lesion screening, visual question answering (VQA), and radiology report generation. For grounded interpretation, HoloCT can pair its textual outputs with 3D masks of the corresponding anatomical regions or findings, providing spatial evidence that readers can inspect.

To develop and evaluate HoloCT at scale, we curated HoloDATA by converting segmentation annotations, question-answer pairs, and radiology reports across datasets into a unified instruction-response format, with 3D masks incorporated where available. HoloDATA comprises 195,921 CT scans totalling more than 61 million slices from 73 public datasets and six clinical cohorts at five hospitals, and contains 6.2 million instruction dialogues and 2.8 million CT-mask pairs across 246 anatomical structures and 50 lesion categories.

Evaluated on 346 tasks across 11 task formulations on 61 internal and 12 external datasets, a single HoloCT-8B model outperformed 82 dataset-specific nnU-Net models on internal segmentation benchmarks and surpassed segmentation foundation models in zero-shot external transfer across both seen and unseen categories of anatomical structures and lesions. HoloCT also exceeded task-specific classifiers as well as medical and general-purpose VLMs in lesion screening, VQA, and report generation. In multicentre clinical validation across 11,455 CT scans from six cohorts at five hospitals, HoloCT surpassed competing models in the segmentation of five lesion categories, including laryngeal lesions, lung cancer and thyroid tumours, as well as in zero-shot abdominal and chest CT report generation. In retrospective reader studies of histopathology-confirmed thyroid tumours and colon lesions, HoloCT-8B achieved higher sensitivity and accuracy than all four participating radiologists, including two senior readers.

Beyond benchmark performance, our analyses revealed bidirectional synergy between clinical understanding and spatial perception. During training, adding text-only dialogues improved 3D segmentation accuracy, whereas incorporating mask-paired dialogues improved lesion screening, VQA, and report generation. At inference, language-guided segmentation delineated previously unseen anatomical structures and lesions as well as diffuse free-text findings, outperforming the leading approach by 22.1 points; conversely, prompting HoloCT to generate corresponding 3D masks alongside its textual outputs significantly improved performance across these interpretation tasks while maintaining mask quality. Together, these results demonstrate that unifying clinical understanding and spatial perception within a single foundation model strengthens both capabilities, aligning AI with how radiologists link diagnostic characterization to 3D anatomy when interpreting CT scans.

References (79)