arXiv:2611.06664cs.CVNov 2026

Manuscript Offprint

arXiv:2611.06664

CardioDrift: Automatic Cardiac Motion Tracking on a 3D Atlas Mesh via Shape-aware Coherent Point Drift with Slice Shift Correction

Reza Akbari Movahed, Abuzar Rezaee, Shatha Alamri, Edmond S. L. Ho, Fani Deligianni, Ali Gooya

Reza Akbari Movahed, Abuzar Rezaee, Shatha Alamri, Edmond S.L. Ho, Fani Deligianni, Ali Gooya

Abstract—Automatic cardiac motion tracking from cine cardiac magnetic resonance (CMR) imaging is essential for quantifying myocardial motion abnormalities associated with cardiovascular disease. Existing methods fall into two groups: those that represent motion without anatomical correspondence across subjects and therefore limit inter-subject motion assessment; and those that represent motion with globally corresponding points, which typically require a time-consuming and error-prone semi-automatic step to fit a cardiac atlas to the subject space. To address these limitations, this study proposes CardioDrift, a fully automatic, atlas-based probabilistic framework that represents subject-specific cardiac motion on a 3D atlas mesh with globally corresponding points. The Coherent Point Drift (CPD) formulation is generalised to jointly register the atlas surfaces of multiple cardiac regions to the anatomically corresponding contours extracted from cine CMR segmentation maps throughout the cardiac cycle. Slice-shift correction is embedded in the same probabilistic model, estimating slice-wise translations that suppress the misalignment artefact limiting atlas-fitting accuracy. Evaluation on 1,301 randomly selected UK Biobank subjects and the M&M dataset, CardioDrift attains Dice similarity coefficients (DSCs) of 92.23±8.70%, 82.11±7.56%, and 88.69±4.13% for the left ventricle (LV), myocardium (Myo), and right ventricle (RV), exceeding the strongest baseline on every distance and overlap metric of both datasets.

Index Terms—Cardiac motion tracking, cine CMR, point-set registration, coherent point drift, slice misalignment.

I. INTRODUCTION

CARDIAC motion assessment plays a central role in the early detection of cardiovascular diseases, a leading cause of mortality worldwide [1]. It is typically performed through visual assessment of cine cardiac magnetic resonance (CMR) imaging [2], a process that is subjective, poorly reproducible, and time-consuming [3], motivating considerable effort to automate tracking and quantify motion abnormalities.

Automated methods face two obstacles. Those operating in the image domain represent motion in a subject-specific coordinate space, establishing no anatomical correspondence across individuals and precluding the population-level comparison that assessing pathological motion depends on. Those using a cardiac atlas mesh achieve such correspondence but require a semi-automatic step to fit the atlas to the subject's space, a process that is error-prone and time-consuming. Moreover, these methods first extract cardiac motion in image space, where it may include motion fields unrelated to the heart, and only then interpolate the motion fields from the image domain onto the mesh, attenuating them in the process.

This work addresses these obstacles with CardioDrift, a non-learning-based point set registration framework formulated using the Coherent Point Drift (CPD) approach [4] that automatically fits a cardiac atlas mesh into the subject's cardiac space and propagates it over the cardiac cycle, using only contour points from cine short-axis (SAX) segmentation maps. A rigid stage first aligns the atlas at the end-diastolic (ED) frame while estimating per-slice translations to correct slice misalignment. A non-rigid stage then deforms the aligned atlas to the slice-shift-corrected contours at each subsequent frame through a shared deformation field. While previous methods lack global correspondence in the derived motion, rely on semi-automatic atlas fitting, capture irrelevant motion through image-domain motion extraction, and attenuate motion through interpolation, CardioDrift automatically fits a cardiac atlas to the subject space accurately and propagates it precisely throughout the cardiac cycle. The main contributions are:

  • Developing a probabilistic point-set registration framework for tracking cardiac motion on a 3D atlas mesh that provides anatomical correspondence across subjects, requiring only cine SAX segmentation maps as input.
  • Generalising CPD to jointly register the left-ventricular endocardium (Endo), left-ventricular epicardium (Epi), and right-ventricular (RV) atlas surfaces to their corresponding contours using a single shared transformation.
  • Embedding slice-shift correction in the rigid stage by estimating SAX-slice translations within the same probabilistic model to suppress inter-slice misalignment and improve atlas-fitting performance.
  • Evaluating the framework on the UK Biobank and Multi-Centre, Multi-Vendor and Multi-Disease (M&M) datasets, demonstrating more accurate atlas fitting and propagation than existing methods, without manual alignment to the subject space.

This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may no longer be accessible.

This study used the UK Biobank Resource under application number 71392. The authors sincerely thank Dr Rona Strawbridge, School of Health and Wellbeing, University of Glasgow, for granting access to the dataset and for her valuable guidance on data usage and interpretation.

Reza Akbari Movahed, Abuzar Rezaee, Shatha Alamri, Edmond S.L. Ho, Fani Deligianni, and Ali Gooya are with the School of Computing Science, University of Glasgow, Glasgow, United Kingdom (e-mail: 2919485a@student.gla.ac.uk; 3128738R@student.gla.ac.uk, 3071412A@student.gla.ac.uk, Shu-Lim.Ho@glasgow.ac.uk; Fani.Deligianni@glasgow.ac.uk; Ali.Gooya@glasgow.ac.uk)

References (31)