arXiv:2611.06791cs.HCNov 2026

Manuscript Offprint

arXiv:2611.06791

A Frame-Level View and Image-Quality Annotation Tool for Fetal Echocardiography: Comparison with Spreadsheet Annotation

Mohamed Azzam, Ziyang Xu, Quinlan Couch, Zoe Keese, Andrea Cadlo, Christine Sedze-DeWolf, Micaiah Uhrmacher, Madelyn Graff, Catherine Fox, Lauren Vatter, Paige Jeffryes, Jason Christensen, Neil Hamill, Shibiao Wan, Ling Li, Jieqiong Wang

Mohamed Azzam¹ | Ziyang Xu¹ | Quinlan Couch² | Zoe Keese² | Andrea Cadlo² | Christine Sedze-DeWolf² | Micaiah Uhrmacher² | Madelyn Graff² | Catherine Fox² | Lauren Vatter² | Paige Jeffryes² | Jason Christensen³,⁴,⁵ | Neil Hamill² | Shibiao Wan⁶ | Ling Li³,⁴,⁵ | Jieqiong Wang¹

¹Department of Neurological Sciences, University of Nebraska Medical Center, Omaha, NE 68198, USA | ²Department of Obstetrics and Gynecology, University of Nebraska Medical Center, Omaha, NE 68198, USA | ³Department of Pediatrics, University of Nebraska Medical Center, Omaha, NE 68198, USA | ⁴Criss Heart Center, Children's Nebraska, Omaha, NE 68114, USA | ⁵Child Health Research Institute, Omaha, NE 68198, USA | ⁶Department of Genetics, Cell Biology and Anatomy, University of Nebraska Medical Center, Omaha, NE 68198, USA

Correspondence: Jieqiong Wang (jiwang@unmc.edu)

Keywords: fetal echocardiography | congenital heart disease | image annotation | standard views | image quality | artificial intelligence

ABSTRACT

Objective: To develop the Cardiologist Annotation Tool (CAT) for frame-level cardiac view and image-quality annotation in fetal echocardiography and compare it with spreadsheet-based annotation.

Methods: CAT provides cine playback, frame navigation, and keyboard-based labeling without manual frame-range entry. Experts annotated 25 studies using both methods, and spreadsheet annotations were audited for predefined data-entry errors. In a randomized crossover study, six medical students annotated two normal studies, one with each method, against an expert reference.

Results: Among 1,746 spreadsheet-annotated files, 6.2% contained major or critical data-entry errors, more frequently in congenital heart disease than normal studies (10.9% vs 3.4%). CAT yielded more annotated view segments per clip (3.6 vs 1.5). Rates of labeled and correctly labeled frames per minute were 1.77 and 1.68 times those with spreadsheets, respectively (both P = 0.031), with gains in all six students. No detectable difference in view-label accuracy was observed.

Conclusion: CAT eliminates manual frame-range entry and enables finer-grained, structured annotation of fetal echocardiography, providing a practical approach to preparing datasets for AI research.

Key points

References (40)