arXiv:2611.04002eess.IVNov 2026

Manuscript Offprint

arXiv:2611.04002

Evaluating the Impact of Nonlinear Registration on Longitudinal PET Analysis in a Rodent Stroke Model

Haytham Ziani, El Mostafa Kalmoun, Zohaib Atif, Hyuk-Sang Kwon

Haytham Ziani¹, El Mostafa Kalmoun¹, Zohaib Atif², and Hyuk-Sang Kwon²

¹ School of Science and Engineering, Al Akhawayn University in Ifrane, Morocco h.ziani@auli.ma

² 3D-BIT Lab, Department of Biomedical Science and Engineering, Gwangju Institute of Science and Technology, Gwangju 61005, South Korea

Abstract. Longitudinal rodent positron emission tomography (PET) studies of stroke and neuromodulation rely on accurate registration to a common atlas space to detect group-level effects. Prior work applying ultra-high frequency low-intensity magnetic stimulation (UHF-LiMS) to a rat model of chronic capsule infarct used affine normalization to a Sprague Dawley MRI template without evaluating that choice [1]. We compare a two-stage (affine and nonlinear) pipeline against an affine-only one for rat PET-to-atlas alignment on the same dataset. Across 32 longitudinal [¹⁸F]-FDG PET scans (8 rats, 4 timepoints), the nonlinear stage gave a higher Dice similarity coefficient on every scan, and the gain was significant at the rat level. Jacobian determinants showed no folding on the sampling grid. Group-level linear mixed-effects maps of change from baseline (AFNI 3dLME), computed identically under both pipelines, differ in the size, number and location of their suprathreshold clusters. In this dataset, the registration pipeline is therefore a variable that can change the interpretation of downstream group-level analyses.

Keywords: Image registration · PET · rodent stroke model · nonlinear registration.

1 Introduction

Longitudinal small-animal positron emission tomography (PET) imaging is a standard tool for tracking disease progression and treatment response over time. A critical step in such studies is registration: aligning each scan, often acquired weeks apart under variable noise and motion conditions, into a common atlas space. The spatial accuracy of this step directly affects the reliability of subsequent group-level statistics across subjects and timepoints.

In rodent PET studies, registration is often treated as a routine step rather than as a methodological variable [2]. A single affine transformation to a template is commonly applied and followed directly by group-level analysis, without quantifying registration accuracy or comparing alternative alignment strategies [3]. Given the small size of rodent brains, their susceptibility to motion and

H.Ziani et al.

the limited resolution of small-animal PET, residual misalignment after affine-only registration can bias quantitative outcomes [2, 4]. The study that introduced ultra-high-frequency, low-intensity magnetic stimulation (UHF-LiMS) for chronic capsular infarct in rats [1] illustrates this gap. Its longitudinal PET scans were normalized to a Sprague Dawley magnetic resonance imaging (MRI) template by affine registration alone, and no registration accuracy was reported.

On that same dataset, we evaluate a two-stage pipeline: affine registration followed by nonlinear Symmetric Normalization (SyN). Registration quality is assessed with the Dice similarity coefficient and Jacobian determinant maps. The downstream effect is assessed with group-level linear mixed-effects maps computed under both pipelines.