arXiv:2608.22965cs.CVAug 2026

Manuscript Offprint

arXiv:2608.22965

Simplified Cross-Modal Calibration for Heterogeneous Event-RGB Stereo Systems

Nico Hessenthaler, Adam T. Müller, Nicolaj C. Stache

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Abstract

Accurate extrinsic calibration between event-based and frame-based cameras remains a practical bottleneck for heterogeneous stereo systems. Existing approaches often require sensor or target motion, precise synchronization, or computationally expensive event-to-image reconstruction. We propose a simple, motion-free cross-modal calibration framework that uses a temporally modulated, blended ChArUco target presented on standard consumer displays. By alternating between the original pattern and a partially blended version, the target reliably triggers events while remaining continuously observable to a frame-based camera, avoiding blank frames and reducing synchronization constraints to a coarse, trigger-based alignment. We discretize events into frames coarsely aligned with the RGB images, apply lightweight denoising, and perform ChArUco-based intrinsic and stereo extrinsic calibration. Extensive experiments assess robustness to blending opacity, display brightness, external illumination, viewing angle, and handheld acquisition. Compared to the strongest motion-based reference (E2Calib + Kalibr) and a non-motion-based reference (Plasberg et al.), our approach reduces the mean reprojection error by 44% and 6%, respectively, while substantially simplifying the calibration procedure. Finally, we demonstrate practical utility in a robotic eye-to-hand calibration case study, showing consistent transformations and stable downstream geometric measurements even under partial occlusions. Code is publicly available at https://github.com/nhessenthaler/simple-evrgb-cal.

1 Introduction

Accurate cross-modal calibration remains a bottleneck for the effective integration of event-based and frame-based cameras in heterogeneous sensor systems [6,2][6, 2]. Similar to monocular event camera calibration [5][5], cross-modal approaches can generally be categorized into motion-based and non-motion-based (static) methodologies.

Motion-based techniques [18,2][18, 2] trigger events through physical movement, but frequently demand computationally expensive neural image reconstructions or intricate algorithms to mitigate inherent motion blur. Conversely, static methods [13,19][13, 19] generate events

© 2026. The copyright of this document resides with its authors. It may be distributed unchanged freely in print or electronic forms.

by modulating light intensity, thus avoiding motion blur. However, these approaches typically rely on specialized hardware and require strict temporal synchronization to prevent the frame-based camera from losing tracking features during blank display cycles [1]. Overcoming these practical complexities is highly motivated by dynamic application scenarios [2], such as robotic hand-eye calibration [3]. These systems require robust and continuous geometric references even when the target is partially occluded by a robotic manipulator.

To address these limitations, we introduce a straightforward, motion-free calibration framework that utilizes a shared, temporally modulated visual stimulus. By continuously alternating a ChArUco [☐] calibration pattern with a partially blended state on a standard consumer monitor, our method reliably induces the log-intensity changes necessary for event generation. Crucially, the target remains continuously visible to the RGB sensor throughout the cycle. This overlay methodology requires only a coarse, trigger-based alignment rather than strict hardware-level synchronization, while eliminating blank frame management, or computationally expensive event-to-image reconstructions. This substantially simplifies the calibration procedure for real-world deployment.

Our main contributions are as follows: (1) A novel cross-modal calibration methodology based on temporal image blending that eliminates the need for specialized hardware and complex image reconstruction, while reducing the synchronization requirement to a coarse alignment. (2) Comprehensive experimental validation demonstrating high statistical stability and robustness against varying display brightness, external illumination disturbances, viewing angle, and handheld acquisition, while reducing the mean reprojection error by 44% and 6% compared to the strongest evaluated motion-based and non-motion-based approaches, respectively. (3) A practical demonstration of the framework's utility in a robotic eye-to-hand calibration case study, achieving stable geometric measurements and consistent spatial transformations even in the presence of partial occlusions.

References (29)