arXiv:2611.04219cs.CVNov 2026

Manuscript Offprint

arXiv:2611.04219

Reliability-Role Collaborative Learning for Semi-Supervised Cardiac Image Segmentation

Zhongrui Xie, Wenfeng Zhang, Wei Hu, Ruitao Xie, Wenjie Wang, Zhouyun Xie, Yi Zhang, Tao Jia

Zhongrui Xie 1,∗^{1,*}, Wenfeng Zhang 1,∗^{1,*}, Wei Hu 1^{1}, Ruitao Xie 2^{2}, Wenjie Wang 3^{3}, Zhouyun Xie 1^{1}, Yi Zhang 1,†^{1,\dagger}, Tao Jia 1,†^{1,\dagger}

1^{1}College of Computer and Information Science,

Research Center of Biomimetic Intelligence and Computational Biomedicine,

Chongqing Normal University, Chongqing, China

2^{2}Shenzhen University of Advanced Technology, Shenzhen, China

3^{3}Wuwei Tumour Hospital of Gansu Province, Wuwei, China

Abstract—Semi-supervised cardiac image segmentation aims to exploit abundant unlabeled images together with limited annotations, but the reliability of pseudo-label supervision is highly uneven across spatial regions. In a peer dual-network collaborative setting, interior regions are usually more stable, whereas boundary regions, low-confidence areas, and confidence-discrepant regions between the two peer networks are more likely to introduce noisy supervision. However, despite this spatial reliability heterogeneity, existing methods typically impose uniform supervision on all unlabeled pixels, overlooking reliability differences across regions and consequently limiting discriminative learning in challenging areas. To address this issue, we propose R2CL (Reliability-Role Collaborative Learning), a reliability-role collaborative learning framework for semi-supervised cardiac image segmentation. R2CL first performs reliability-role modeling based on confidence relationships between two networks, assigning different training roles to unlabeled regions: mutually uncertain regions are used for entropy regularization, confidence-discrepant regions for directional knowledge transfer, and mutually confident regions as reliable supervision anchors. Based on this formulation, Reliability-Role Mixed Cross Learning (RR-MCL) operationalizes these learning roles through region-mixed training, directional cross-network supervision, and entropy regularization over mutually uncertain regions. Subsequently, Reliability-Transition Prototype Contrastive Learning (RT-PCL) constructs query features from foreground-adjacent reliability-transition regions and learns network-specific class prototypes from mutually confident regions, thereby enhancing feature discriminability around ambiguous boundaries and difficult regions. Meanwhile, High-confidence Context Refinement (HCR) further exploits reliable interior pixels and trusted dense blocks within mutually confident regions to complement stable contextual supervision. R2CL achieves stable improvements in region-overlap and boundary-related metrics across multiple datasets, with more evident advantages on the foreground-sparse MVAA-CT dataset.

Index Terms—cardiac segmentation, semi-supervised learning, contrastive learning, mitral valve segmentation

I. INTRODUCTION

Medical image segmentation supports computer-aided diagnosis, quantitative image analysis, and clinical planning. CNN-based models such as U-Net [1] and nnU-Net [2], together with Transformer architectures including TransUNet [3] and Swin UNETR [4], have advanced anatomical segmentation. However, their performance relies heavily on expert pixel-wise annotations, which are particularly costly for volumetric images. Semi-supervised learning alleviates this burden by exploiting abundant unlabeled data alongside limited annotations.

Existing semi-supervised learning approaches include pseudo-label learning [5], Mean Teacher [6], and cross pseudo supervision [7], often combined with consistency regularization [8] and data mixing [9]. In medical image segmentation, representative methods such as UAMT [11], MC-Net [10], BCP [12], and ALHVR [13] further incorporate uncertainty estimation, perturbation consistency, copy-paste mixing, and high-value region utilization to alleviate annotation scarcity. Nevertheless, these methods to some extent implicitly assume homogeneous supervision across unlabeled pixels, thereby overlooking differences in reliability and learning roles among spatial regions.

However, the reliability of unlabeled predictions is inherently heterogeneous across spatial regions. Interior regions of anatomical structures generally exhibit stable predictions, whereas boundary regions, low-confidence areas, and disagreement regions between dual networks are more susceptible to class ambiguity and noisy pseudo-label supervision. This issue is particularly pronounced in cardiac MRI and mitral valve CT segmentation, where local false positives, structural discontinuities, and boundary deviations may compromise downstream clinical analyses, including ventricular volume estimation [14], [15], biventricular quantification [16], valve geometry assessment, and shape continuity analysis. More importantly, existing semi-supervised segmentation methods often implicitly assume that all unlabeled pixels contribute equally to model optimization and therefore impose uniform

This work was supported by the National Key Research and Development Program of China under Grant 2025YFC2708700, in part by the BrainGain Plan of New Chongqing Foundation under Grant CSTB2024YCJH-KYXM0108, in part by the Natural Science Foundation of Chongqing under Grant CSTB2025NSCQ-GPX1037, in part by the Natural Science Foundation Innovation and Development Joint Fund Project of Chongqing under Grant CSTB2023NSCQ-LZX0148, in part by the Science and Technology Research Program of Chongqing Municipal Education Commission under Grants KJQN202500532 and KJQN202500511, and in part by Wuwei Tumour Hospital of Gansu Province under Grant WW25Z01SF075.

Zhongrui Xie and Wenfeng Zhang contributed equally to this work.

Corresponding authors: Yi Zhang (zhangyi@cqnu.edu.cn); Tao Jia (tjia@cqnu.edu.cn).

consistency regularization or pseudo-label supervision across all regions. Such a homogeneous supervision assumption overlooks the heterogeneous reliability characteristics of different spatial regions. In contrast, different unlabeled regions naturally assume distinct learning roles: some are suitable for uncertainty suppression, some facilitate directional knowledge transfer, while others provide reliable supervisory signals. Therefore, unlabeled learning should not merely be formulated as a uniform consistency regularization problem, but rather as a reliability-role learning problem.

Peer-network confidence relationships provide a basis for identifying different learning roles. Inspired by complementary supervision in co-training [17], mutually uncertain regions can be used for entropy regularization, confidence-discrepant regions for directional knowledge transfer, and mutually confident regions as candidates for reliable supervision. This role-based formulation allows different unlabeled regions to provide distinct training signals rather than relying solely on a single uniform supervisory objective.

Motivated by the above observations, we propose R2CL (Reliability-Role Collaborative Learning), a reliability-role collaborative learning framework for semi-supervised cardiac image segmentation. R2CL first performs reliability-role modeling based on dual-network confidence relationships, assigning distinct learning roles to unlabeled regions. RR-MCL then operationalizes these roles through region-mixed training, directional cross-network supervision, and entropy regularization. Moreover, RT-PCL focuses on foreground-adjacent reliability-transition regions, where query features are contrasted against network-specific class prototypes to enhance feature discrimination around ambiguous structures. HCR further exploits reliable interior pixels and trusted dense blocks within mutually confident areas to provide stable contextual supervision. Together, these components integrate complementary supervisory signals from different reliability roles into a unified collaborative framework, enabling role-specific exploitation of heterogeneous unlabeled supervision.

Our main contributions are as follows:

• We propose R2CL, a reliability-role collaborative learning framework for semi-supervised cardiac image segmentation. R2CL introduces a reliability-role modeling strategy that reformulates unlabeled learning as a reliability-role learning problem based on dual-network confidence relationships. By assigning distinct learning roles to unlabeled regions, it avoids uniform supervision across all unlabeled pixels.

• We develop a role-specific collaborative learning mechanism that exploits complementary supervisory signals from different reliability roles through uncertainty suppression, reliability-transition learning, and high-confidence context refinement. This mechanism is instantiated by three complementary components, namely RR-MCL, RT-PCL, and HCR, enabling role-specific exploitation of heterogeneous unlabeled supervision.

• Experiments on the ACDC and MVAA-CT datasets demon-

strate improvements in region-overlap and boundary-related metrics, with particularly evident advantages in foreground-sparse mitral valve CT segmentation.

References (28)