arXiv:2611.04257cs.CVNov 2026

Manuscript Offprint

arXiv:2611.04257

ProGeo-RC: Prototype-guided Semantic Reliability and Geometric Error Calibration for Semi-supervised Cardiac Image Segmentation

Yunfei Zhu, Wenfeng Zhang, Pan Zeng, Xin Huang, Tao Jia, Weiting Shao, Wei Hu, Jianming Hu

Yunfei Zhu 1∗^{1*}, Wenfeng Zhang 1∗^{1*}, Pan Zeng 1^{1}, Xin Huang 1^{1}, Tao Jia 1^{1}, Weiting Shao 2^{2}, Wei Hu 1†^{1\dagger}, Jianming Hu 3†^{3\dagger}

1^{1}College of Computer and Information Science,

Research Center of Biomimetic Intelligence and Computational Biomedicine,

Chongqing Normal University

2^{2}School of Educational Sciences, Chongqing Normal University

3^{3}School of Physics and Electrical Engineering, Chongqing Normal University

Chongqing, China

Abstract—Semi-supervised medical image segmentation aims to train reliable segmentation models using limited labeled data and abundant unlabeled data. However, existing methods typically rely on prediction confidence or model consistency to estimate pseudo-label reliability, but these criteria are insufficient to characterize both semantic reliability and geometric plausibility. To address this issue, we propose ProGeo-RC, a prototype-guided semantic reliability and geometric error calibration framework for semi-supervised medical image segmentation. ProGeo-RC consists of two key modules: Prototype-guided Semantic Reliability Estimation (PSRE) and Structured Semantic-Geometric Error Calibration (S-SGEC). PSRE uses probabilistic class prototypes to estimate the semantic reliability of unlabeled predictions and calibrate pixel-wise teacher pseudo labels, while S-SGEC introduces signed-distance-field-based geometric constraints to refine ambiguous boundaries and suppress spurious foreground responses outside target structures. Experiments on the ACDC and MVAA-CT datasets show that ProGeo-RC achieves better performance compared with representative semi-supervised segmentation methods. Under the 10% labeled setting on ACDC, ProGeo-RC improves DSC and Jaccard by 0.37% and 0.49% over the corresponding second-best results, while reducing 95HD and ASD by 0.61 and 0.21, respectively. These results indicate that joint semantic reliability estimation and geometric error calibration can provide more reliable pseudo supervision for semi-supervised medical image segmentation.

Index Terms—Semi-supervised Learning, Cardiac Image Segmentation, Prototype Learning, Geometric Calibration

I. INTRODUCTION

Computer-aided diagnosis systems rely on accurate anatomical segmentation for disease assessment, treatment planning,

and postoperative follow-up. In cardiac image analysis, reliable segmentation supports ventricular volume quantification, ejection fraction estimation, valve morphology analysis, and personalized treatment planning. Deep learning networks, including U-Net, V-Net, 3D U-Net, and nnU-Net, have achieved strong performance in medical image segmentation [1]–[4] and cardiac segmentation [5]–[9]. However, they usually require extensive pixel-level annotations, which are labor-intensive, time-consuming, and clinically demanding. Learning from limited labeled data and abundant unlabeled data therefore remains a key challenge in semi-supervised cardiac image segmentation.

Existing semi-supervised segmentation methods mainly exploit unlabeled data through pseudo-label learning, consistency regularization, teacher-student frameworks, and cross pseudo supervision [10]–[13]. Although these methods have demonstrated the effectiveness of exploiting unlabeled data, their performance largely depends on the reliability of pseudo supervision. Common strategies assess pseudo-label reliability using prediction confidence or model consistency, either by selecting high-confidence regions or by enforcing consistency across perturbations, branches, or teacher-student models [11], [12]. However, these criteria are imperfect surrogates for true reliability. High-confidence predictions may still deviate from the semantic distributions of their predicted classes [14], while consistent predictions do not necessarily guarantee geometrically plausible structures [15]–[17]. Therefore, the key challenge in semi-supervised cardiac image segmentation lies not only in exploiting unlabeled data, but also in identifying reliable pseudo supervision from unlabeled predictions.

This work was supported by the National Key Research and Development Program of China under Grant 2025YFC2708700, in part by BrainGain Plan of New Chongqing Foundation under Grant CSTB2024YCJH-KYXM0108, in part by Natural Science Foundation of Chongqing under Grant CSTB2025NSCQ-GPX1037, in part by Natural Science Foundation Innovation and Development Joint Fund Project of Chongqing under Grant CSTB2023NSCQ-LZX0148, in part by Science and Technology Research Program of Chongqing Municipal Education Commission under Grant KJQN202500532 and KJQN202500511.

This challenge motivates assessing pseudo-supervision reliability from both semantic and geometric perspectives. Semantically, models may produce overconfident errors, where high-confidence pixels do not match the feature distribution of the predicted class [14], [18], [19]; agreement between two models also does not necessarily imply feature-space reliability. Geometrically, cardiac structures exhibit anatomical continuity and clear boundaries, making confidence-based

∗^{*}Co-first authors contributed equally to this work.

†^{\dagger}Corresponding authors: Wei Hu (wei369.workstation@cqnu.edu.cn); Jianming Hu (hujianming@cqnu.edu.cn).

filtering insufficient for boundary ambiguity, isolated false positives, and spurious responses outside target structures [20]–[22]. Although prototypes, intra-class distribution modeling, boundary-aware learning, and distance-based constraints can improve semantic discrimination and structural plausibility, they are usually used as auxiliary regularization or representation learning constraints. These observations suggest that reliable pseudo supervision should jointly consider feature-space semantic consistency and image-space geometric plausibility.

To this end, we propose ProGeo-RC, a prototype-guided semantic reliability and geometric error calibration framework for semi-supervised cardiac image segmentation. Unlike methods relying mainly on prediction confidence or model consistency, ProGeo-RC assesses pseudo-supervision reliability from two complementary aspects: whether pixel features match the predicted class distribution in feature space and whether predicted regions are geometrically plausible in image space. By jointly modeling semantic consistency and geometric plausibility, ProGeo-RC provides more reliable pseudo supervision and reduces the accumulation of erroneous pseudo labels.

Our main contributions are summarized as follows:

  • We propose ProGeo-RC, a prototype-guided framework for semi-supervised cardiac image segmentation that jointly models pseudo-supervision reliability from complementary semantic and geometric perspectives, thereby mitigating the accumulation of unreliable pseudo labels during training.

  • We develop Prototype-guided Semantic Reliability Estimation (PSRE) and Structured Semantic-Geometric Error Calibration (S-SGEC) to improve pseudo-supervision quality. PSRE evaluates unlabeled predictions using class-wise probabilistic prototypes, while S-SGEC uses signed distance fields to calibrate boundary ambiguity and suppress structurally implausible foreground responses.

  • Extensive experiments on the ACDC and MVAA-CT datasets demonstrate that ProGeo-RC consistently outperforms representative semi-supervised segmentation methods under different annotation settings. Ablation studies and qualitative visualizations further verify the effectiveness and generalizability of the proposed framework.

References (32)