arXiv:2611.04405cs.CVNov 2026

Manuscript Offprint

arXiv:2611.04405

DR-LiteNet: A Lightweight Explainable Hybrid CNN Framework for Imbalanced Diabetic Retinopathy Grading via Adaptive SMOTE Fusion

Nishi Kanta Paul, Md Shihabul Islam Shovo, Audrija Chowdhury, Israt Jahan Esha

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Nishi Kanta Paul

NIMISHES Lab

Dhaka, Bangladesh

nishikantapaul108@gmail.com

Md Shihabul Islam Shovo

NIMISHES Lab

Dhaka, Bangladesh

shihabul900@gmail.com

Audrija Chowdhury

Brac University

Dhaka, Bangladesh

audrija.chowdhury@g.bracu.ac.bd

Israt Jahan Esha

Brac University

Dhaka, Bangladesh

israt.jahan.esha@g.bracu.ac.bd

Abstract

Automated diabetic retinopathy (DR) grading from colour fundus photographs is held back by two compounding challenges: severe class imbalance across five severity grades and the heavy computational cost of large scale architectures in resource constrained clinical settings. We introduce DR-LiteNet, a dual branch hybrid convolutional neural network that tackles both problems at once. The CNN branch extracts 1,280 dimensional deep features through EfficientNetB0, while the handcrafted (HC) branch produces a compact 51 dimensional lesion descriptor capturing vessel density, exudate intensity, texture entropy, and HSV colour histograms. Concatenating both branches yields a 1,331-d hybrid embedding, on which Adaptive SMOTE (ADASYN) is applied during training to synthesise minority class feature vectors, correcting distributional skew without touching the image space. A two phase training protocol first warms up the classification head on balanced features, then fine tunes the full network end to end. Grad CAM saliency maps deliver post-hoc clinical explainability. Tested on APTOS 2019 under five fold stratified cross validation, DR-LiteNet reaches 88.77% ± 0.61 accuracy, a quadratic weighted kappa (QWK) of 0.884 ± 0.010, and a macro F1 of 0.792 ± 0.008 with only 4.69 M parameters beating ResNet50 (23.5 M) by ΔQWK = 0.022 while staying practical on a single Google Colab T4 GPU. The source code of this project is available at: https://github.com/Nishi-Kanta-Paul/DR-LiteNet.

Keywords: Diabetic retinopathy, class imbalance, ADASYN, EfficientNet, hybrid feature fusion, Grad CAM, explainable AI, fundus photography.

I Introduction

Despite extensive global medical efforts, diabetic retinopathy (DR) remains one of the leading preventable causes of blindness, threatening over 100 million people living with diabetes [1]. Grading disease severity into five stages (No DR, Mild, Moderate, Severe, and Proliferative) from colour fun-

dus photographs is essential for timely clinical intervention, yet manual grading is inconsistent and wholly impractical at the population scale demanded by under resourced teleophthalmology services [2].

Deep learning technologies have completely changed how automated DR grading occurs. The research conducted by Gulshan et al. [2] shows that CNNs trained at scale can accurately screen for DR compared to specialists, while more recent studies managed to get past a QWK score of 0.90 for APTOS 2019 based on efficient architecture and multi tasking models [9] and by using ensembling approaches [10]. However, there are two major issues preventing effective usage of deep learning models in practice. First, public DR datasets are extremely unbalanced because severe and proliferative grades make up only 13% of the entire sample size in APTOS 2019. Second, high quality architectures with millions of parameters require significant computational power to train and run beyond GPU limits in poor countries.

We present DR-LiteNet, which addresses both barriers through three coordinated contributions:

  1. Hybrid dual branch fusion: EfficientNetB0 deep features are concatenated with hand engineered retinal lesion descriptors, merging data driven representations with explicit clinical biomarker knowledge.

  2. Feature level ADASYN: Adaptive synthetic oversampling in the fused embedding space generates minority class samples along the true lesion feature manifold, outperforming both image level augmentation and class weighted loss baselines.

  3. Integrated Grad CAM: Gradient weighted class activation maps localise pathological regions, providing interpretable evidence to support clinician trust and regulatory compliance.

DR-LiteNet reaches QWK = 0.884 with only 4.69 M parameters, surpassing ResNet50 (23.5 M) by 0.022 QWK under rigorous five fold cross validation, and trains in ≈55 GPU minutes per fold on a single NVIDIA T4.

The remainder of this article is organized as follows. Section II reviews related work on deep learning based diabetic retinopathy grading, class imbalance handling, hybrid CNN and handcrafted feature fusion, and explainability in clinical AI. Section III details the proposed DR-LiteNet methodology, including the CNN and handcrafted lesion feature branches, feature level ADASYN fusion, the classification head and loss function, Grad CAM explainability, and the two phase training protocol. Section IV describes the experimental setup, covering the dataset and splits, baseline models, and evaluation metrics and implementation. Section V presents the quantitative results, ablation study, ROC analysis, and per class comparison across baselines. Finally, Section VI concludes the paper and outlines directions for future work.

References (23)