Halley: A Predictive Control Plane for Optical AI Data Center Networks

Manav Mishra, Krishna M. Sivalingam

Manav Mishra 1^{1} and Krishna M. Sivalingam 2^{2}

1^{1}Prompeteer.ai, Los Angeles, CA 90066, USA

2^{2}Department of Computer Science and Engineering, Indian Institute of Technology Madras, Chennai, India

Emails: manav@prompeteer.com, skrishnam@cse.iitm.ac.in

CORRESPONDING AUTHOR: Manav Mishra.

Abstract—A frontier AI model is trained in an AI data center, on tens of thousands of accelerators joined by a dedicated network, and every training step ends with all of them exchanging data at once. Between racks, that network is optical, and each of its four layers, from lasers to switches, runs a fixed or after-the-fact policy. Lasers sharing an enclosure, cooling, and power can fail together. At a fixed spare ratio, correlated failure provably caps a pool's availability however large it grows. In this paper, we present a comprehensive predictive control plane framework, called Halley, that reads each resource's next state and acts before the failure occurs. It has four components, each carrying a formal guarantee: LightReserve that sizes the laser pool to provide a coverage bound, FoldFit that schedules the switch within 11/9 of the optimal, ThermaLead that holds a microring with one-step-ahead control, and TriageGuard that protects the highest-risk modules first. Halley gives each layer a predictive controller that defers to the deployed policy when unsure. Composed from simulations at that point, effective goodput, the share of ideal throughput kept, rises from 65.2% to 76.5% if a window that exhausts its spares is lost. If only the dark channels' bandwidth is lost, it reaches 67.4%. Per megawatt, that is up to 1.03–1.17 times the training; for the same training, up to 3.3–14.7% less data center capacity. Halley's fallback circuits are formally verified and are shown to achieve close timing on a commercial FPGA, and pass a 130 nm signoff.

Index Terms—Co-packaged optics, common-cause failure, data center networks, distributed training, microring modulators, optical circuit switching, optical interconnects, predictive control, reliability

I. INTRODUCTION

A frontier AI training run usually occupies a single cluster in an AI data center, where a dedicated network moves data among tens of thousands of accelerators. Between racks, copper cannot carry that data within its power and reach budget, so the network is optical [1], and the industry is now moving the optics onto the package itself, next to the switch or accelerator silicon, an arrangement known as co-packaged optics (CPO).

This network, the fabric, has an optical data plane of four layers, each managed on its own today. A shared pool of external lasers supplies light to many photonic engines, the on-package optical transceivers of CPO. An optical circuit switch (OCS) joins those engines to one another by connecting whole light paths instead of forwarding individual packets. Microring modulators, ring resonators a few microns in radius, encode the data onto each wavelength. The lasers arrive in field-replaceable modules that are swapped in service.

At hundred-thousand-accelerator scale, reliability, network topology, and checkpointing have become first-order design constraints [1]. Each layer faces an online allocation decision under a hard service constraint: how many spare lasers the pool should hold, which circuits the switch should hold and for how long, where each ring's heater should be set, and which modules receive the few hot spares, each wired to its module in advance. The deployed policies this paper replaces, which we call reactive for short, either fix each answer once in advance or make it only after the event it should have anticipated. Training is bulk-synchronous: every training step ends in a collective, a phase in which all accelerators communicate at once and which also acts as a barrier, so the step finishes only when its slowest link does. A drifted ring, a failed laser, or a late switch reconfiguration therefore leaves every accelerator idle at that barrier.

Software-defined networking provisioned for a separate control plane from the data plane. Production optical fabrics use that approach for provisioning. For example, Google's Jupiter fabric routes on a predicted traffic matrix [2] and TPUv4 reconfigures its optical circuit switches to ride through outages [3], [4]. Similarly, Ironwood TPU's 9,216-chip superpods use them to route around interruptions, the MixNet research system reconfigures ahead of a predicted all-to-all [5]. The Opus system reconfigures photonic rails at the boundaries between parallelism phases [6]. Failure prediction for pluggable optical transceivers is now validated on production data [7], [8]. We observed that existing control planes do not forecast the co-packaged optical hardware itself, a laser's failure or a ring's drift, and hence do not act before the failure or drift arrives.

Proposed Halley framework: This work presents Halley, a control plane that provides these necessary features. The system has multiple components as described below. The Halley framework provides every layer with a component of its own. LightReserve sizes the laser pool to a coverage bound instead of a fixed ratio: a floor on the chance that its spares absorb every failure in a window, valid for the assumed failure rate and correlation. FoldFit schedules the OCS so that, under stated conditions, a schedule's total dwell time, the time its circuits are held, stays within 11/9 of the shortest possible, a bound that leaves out switching delay. ThermaLead sets each microring's heater ahead of the drift. TriageGuard steers a limited budget of hot spares to the modules most likely to fail. Each component predicts its layer's next state and acts before it arrives. Each steps aside to the reactive system that it replaces when its forecast is stale or unsure. Hence, for such a forecast the result is no worse than current systems, though a confident but wrong forecast has no such floor yet.

Adding spares is the usual way to keep a shared laser pool lit. In a co-packaged pool the lasers are unlikely to fail independently. NVIDIA's external laser module holds eight lasers in one temperature-controlled enclosure [9]. Hence, the lasers of a module share its heat and often one power supply, and a thermal or power fault that stresses one laser stresses its neighbors as well. Failures that arrive together can exhaust the spares. Growing the pool at the same spare ratio, the share of the pool held as spares, does not spread that risk away, since the next burst of failures is correlated too.

At a fixed spare ratio, availability converges as the pool grows to a closed-form ceiling A∗<1A^{*} < 1 that depends on the failure correlation ρ\rho and the per-laser failure probability but not on the pool's size. Raising the spare ratio does lift availability, but past a certain point so slowly that a high target needs a pool larger than any operator would deploy. The limit itself is classical. When exchangeable failures are positively correlated, the failed fraction of a large pool converges to a random level instead of to its mean [10]. Common-cause models in reliability engineering bound redundant systems the same way [11], [12]. What this paper adds is its consequence for a pooled laser supply: where the cap binds, what it costs in spares, and the cheaper alternative. However, correlation can be controlled. Separating the lasers into distinct thermal and power domains and sourcing them from diverse batches raises the ceiling, which redundancy cannot.

Technical contributions: The main contributions are:

  • First, it carries the classical exchangeable limit over to pooled laser supplies and proves that in a pool of many modules the correlation between modules, more than within them, sets the cap. Under a stated cost model, it also finds that decorrelating before buying spares is the cheaper path across the range of correlations considered plausible.

  • Second, it builds the proposed Halley control plane framework, that has four major components. Three of its four components carry a formal guarantee, stated in idealized form later. The novel aspect is the design for the failure physics of the AI data center.

  • Third, it composes the components into effective cluster goodput under two readings of a spare shortfall, couples the laser and thermal losses through a shared common cause, reports the tail as well as the mean, and proves a closed form for the correlation-driven part of that tail.

  • Fourth, it synthesizes, places, and routes the fallback circuits for a commercial field-programmable gate array, carries the same sources through signoff as a SkyWater 130 nm layout, and formally verifies their register-transfer design, the part of Halley that can be built today.

The paper also reports a detailed performance study of the proposed mechanisms, based on simulation and mathematical modeling, and their circuit-level realization: an FPGA build and a signed-off SkyWater 130 nm layout. The software implementation of these components and the hardware design are available at [13].

Important Results: At the correlation we assume for a well-built package and the stress failure rate of Section III-III-B, a pool with one spare per active laser, the 2×2\times budget cap we assume throughout, cannot pass 99.670% availability however large it grows. A reserve of four spares for 32 channels, the proportion an analyst reports for a related shipping part, reaches only 86.3%. Availability of 99.999% is then out of reach for any spare ratio within that cap. For a 32-channel pool at that correlation, 99.999% stays out of reach within the 2×2\times cap whenever a laser's failure probability per restock window exceeds about 2.4×10−42.4 \times 10^{-4}. At 50 failures per billion hours (50 FIT), the Optical Internetworking Forum (OIF) target for a laser source, which we apply to each laser, a laser crosses that probability once the restock window exceeds about 200 days.

With the spare count held at the 23 lasers our sizing rule returns for a 99% target, cutting the correlation from ρ=0.15\rho = 0.15 to ρ=0.03\rho = 0.03 moves availability from about 99% to just past 99.999%. Under a stated cost model at the stress rate, reaching 99.999% by separating the pool first and then sizing its spares costs 44,100 in all, against 234,000 for spares alone.

The overall figure of merit is effective cluster goodput, defined as the fraction of the cluster's ideal throughput that survives the losses of the fabric. At the stress setting, composing the simulated components lifts it from 65.2% to 76.5%, a 17.3% relative gain. That figure counts every window whose failures exhaust the spares as lost, which we call the coverage reading. On the lit-share reading, in which only the dark channels' bandwidth is lost, goodput rises from the same 65.2% baseline to just 67.4%. Most of the gain thus comes from a provisioning decision: the larger spare pool that LightReserve sizes for the correlation a static reserve ignores. Holding that pool to the 2×2\times cap costs only 0.2 points, and where no spare count within the cap reaches a target, LightReserve determines the decorrelation it needs. ThermaLead's simple forecast does slightly worse than the deployed dither lock on the stress trace; gated to fall back to that lock whenever its recent error is the larger of the two, it has 2.1% fewer lock losses. At 50 FIT and a 90-day restock the fixed reserve already covers nearly every window, so the composed relative gain falls to about 1.3%; with yearly restocks, 99.999% still exceeds the 2×2\times cap at 50 FIT.

Within each reading, the stress-case gain is an upper bound on the useful compute freed from the same silicon and power, because it treats fabric stall as the only recoverable loss. This bound matters because power and local approval now limit how fast new AI data centers are built. A new grid connection can take five to ten years [14]. Around 45 US data center projects worth $68 billion were blocked or delayed at the local level between April and June 2026 [15]. Every point of goodput that the fabric loses is capacity that was built and powered but did no useful work. At the bound, what Halley recovers means up to 14.7% fewer new megawatts to site and connect for a given training target, or up to 1.17 times as much training from the power already in place, with no wait for a new grid connection. On the lit-share reading the figures are 3.3% and 1.03 times. Energy per unit of training falls too, though by less, since a waiting accelerator draws less than full power.

Figure

Fig. 1. The CPO data plane. Top: its four layers, each with the decision it must make and the policy deployed today. Bottom: the light path. External laser modules supply light to each photonic engine, microring modulators in the engine encode data onto it, and the OCS switches the modulated signals between engines [schematic].

The remainder of the paper is organized as follows. Section II presents the background material and related work. Section III presents the impact of failure correlation on various metrics such as availability. Section IV presents the control plane framework and the four mechanisms proposed in this paper. Section V presents a detailed performance study of the proposed mechanisms based on simulation and mathematical modeling studies. Section VI presents the circuit-level realization of the proposed mechanisms, built for a commercial FPGA and signed off as a SkyWater 130 nm layout. Section VII presents a detailed discussion of the proposed framework including its limitations. Section VIII concludes the paper.