arXiv:2611.04604eess.IVNov 2026

Manuscript Offprint

arXiv:2611.04604

Sparse-View 3D Coronary Reconstruction from Vessel Segmentations Using a Diffusion Prior

Tianyuan Wang, Kenan Niu, Stefano Stramigioli

Tianyuan Wang, Kenan Niu, and Stefano Stramigioli, Fellow, IEEE

Abstract—Reconstructing three-dimensional (3D) coronary anatomy from sparse angiographic views could support percutaneous coronary intervention, but limited angular coverage and imperfect vessel segmentations introduce substantial geometric ambiguity. We propose a vessel-specific reconstruction framework combining a learned 3D diffusion prior, visual-hull initialization, and projection-based data consistency. The unconditional diffusion model is trained on coronary vessel masks without paired 2D–3D data and reused across different view counts without retraining. During inference, a scaled visual hull initializes reconstruction, while projection-based updates constrain diffusion refinement using patient-specific vessel observations. We evaluated the framework on simulated angiograms derived from ImageCAS computed tomography angiography volumes using two, four, and eight views at two contrast levels. Across 50 evaluation coronary-tree cases, the proposed method achieved higher mean Dice and clDice than visual hull, deep image prior (DIP), and hash-grid implicit neural representation (INR) at all view counts under reduced contrast. With eight views, improvements over DIP, the best-performing baseline at lower contrast, were approximately 0.13 in Dice and 0.22 in clDice. At higher contrast, performance remained competitive with hash-grid INR, the best-performing eight-view baseline. The preferred diffusion starting timestep depended on observation quality and view count, with excessive refinement reducing accuracy at higher contrast. Projection guidance improved both metrics across all conditions. Averaging stochastic reconstructions further improved accuracy, while sample disagreement localized errors with average-precision gains of 0.14–0.21 over error prevalence. These findings support diffusion-prior reconstruction from sparse vessel observations, although clinical validation remains necessary.

Index Terms—Coronary artery reconstruction, diffusion priors, percutaneous coronary intervention, stochastic reconstructions, vessel segmentation, X-ray angiography.

I. INTRODUCTION

PERCUTANEOUS coronary intervention (PCI) is primarily performed under two-dimensional (2D) X-ray angiography and fluoroscopy, where the interventionalist navigates guidewires and catheters through a complex three-dimensional (3D) coronary anatomy based on projected images [1]. Although the C-arm can be rotated to acquire the coronary tree from different viewing angles, each projection inevitably loses depth information and may suffer from vessel overlap and foreshortening. In clinical practice, these ambiguities are largely resolved through the operator's experience and by acquiring additional projections when necessary. Similar ambiguities pose an even greater challenge for image-guided robotic PCI, where a robotic system must infer the spatial relationship between the device and vascular anatomy from limited 2D observations. Since different viewing angles are already accessible with a rotational C-arm, an attractive alternative is to exploit a small number of angiographic views to recover a 3D representation of the coronary vasculature, thereby providing more explicit spatial information for either human or robotic navigation.

Unlike conventional computed tomography (CT), PCI guidance does not necessarily require reconstruction of the full attenuation distribution within the imaged volume. For navigation, the primary structures of interest are the coronary vessels themselves. This motivates a task-specific reconstruction formulation in which vessel-related information is first extracted from a small number of X-ray projections through segmentation and subsequently used to infer the corresponding 3D coronary geometry [2]. Such a formulation focuses reconstruction on vascular structures, but recovering a complex vascular tree from only a few segmented projections remains severely ill-posed. In particular, multiple 3D vessel configurations may produce similar 2D segmented observations, and distal branches or overlapping vessels may not be uniquely resolved from the available views. Anatomical prior knowledge can therefore help constrain the reconstruction and reduce these ambiguities.

Generative models provide a promising mechanism for incorporating such prior knowledge [3]. In particular, diffusion models can learn the distribution of anatomically plausible 3D coronary structures from a population of vessel geometries and can therefore constrain sparse-view reconstruction toward realistic vascular anatomies. From an inverse-problem perspective, the reconstruction can be regarded as balancing two sources of information [4]: patient-specific observations derived from the acquired X-ray images and a learned anatomical prior provided by the diffusion model. A strong prior can compensate for information that is absent from sparse projections, but it must remain sufficiently constrained by the observations to preserve the patient-specific vessel geometry. The appropriate balance between these two components therefore becomes a central issue in diffusion-prior reconstruction.

This research was financed by the EFRO OOST fund.

Tianyuan Wang, Kenan Niu, and Stefano Stramigioli are with the Robotics and Mechatronics group, University of Twente, 7500 AE Enschede, The Netherlands (e-mail: tianyuan.wang@utwente.nl, k.niu@utwente.nl, s.stramigioli@utwente.nl).

IEEE TRANSACTIONS ON MEDICAL IMAGING

This balance becomes particularly important when the observations themselves are uncertain. In a vessel-specific reconstruction pipeline, the X-ray projections are first converted into vessel observations by a segmentation model. However, segmentation quality depends strongly on the visibility of the vessels in the original angiographic images. Reduced vessel contrast, noise, overlap, or weak visualization of small branches may lead to missing vessels, inaccurate boundaries, or false-positive structures. If these imperfect segmentations are imposed as strong deterministic constraints, their errors can directly propagate into the reconstructed 3D vessel tree and prevent the learned prior from correcting them. Conversely, if the observations are weighted too weakly, the reconstruction may follow the learned population prior while losing important patient-specific information.

In this work, we investigate sparse-view coronary reconstruction by combining a pretrained 3D anatomical diffusion prior with soft visual-hull initialization and projection-based data consistency. Rather than treating segmented vessels as exact geometric constraints throughout reconstruction, the visual hull provides an initial spatial estimate, while projection-based updates encourage agreement with the observed vessel structures during diffusion refinement. We systematically vary vessel contrast and the number of projection views to investigate how observation quality and angular sparsity affect reconstruction performance and the preferred diffusion starting timestep. This allows us to examine the tradeoff between preserving measurement-derived geometry and allowing refinement by the learned anatomical prior. The proposed framework aims to recover patient-specific 3D coronary geometry from a small number of angiographic views, with potential applications in human or robotic PCI guidance.

The main contributions of this work are as follows:

  1. We formulate sparse-view coronary reconstruction as a vessel-specific inverse problem and introduce a framework that combines a learned anatomical diffusion prior with soft visual-hull initialization and projection-based data consistency.

  2. We systematically investigate how vessel contrast and the number of projection views affect the reconstruction performance of the proposed method and baseline approaches when using imperfect vessel segmentations.

  3. We demonstrate that averaging reconstruction samples generated using different noise realizations improves accuracy relative to single-sample reconstruction, while disagreement among samples provides a spatial indicator of potentially unreliable regions.

References (25)