Manuscript Offprint

arXiv:2608.23014

AnaDiffusion: Anatomically CompositionalLatent Diffusion for Controllable 3D Brain MRI Generation

Huiwen Han, Lulin Liu, Bangya Liu, Yuanhao Cai, Nuo Chen, Xiaoqing Wang, Ziqian Xie, Chenyu You, Shuiwang Ji, Degui Zhi, Zhiwen Fan

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Huiwen Han1,2,†^{1,2,\dagger}, Lulin Liu2,3,†^{2,3,\dagger}, Bangya Liu4^{4}, Yuanhao Cai5^{5}, Nuo Chen2^{2}, Xiaoqing Wang2^{2}, Ziqian Xie6^{6}, Chenyu You7^{7}, Shuiwang Ji2^{2}, Degui Zhi6^{6}, Zhiwen Fan2^{2}

1^{1}Stanford University, 2^{2}Texas A&M University, 3^{3}University of Minnesota, 4^{4}University of Wisconsin-Madison, 5^{5}Johns Hopkins University, 6^{6}UTHealth Houston, 7^{7}Stony Brook University †^{\dagger}Equal contribution

3D brain MRI generation has made significant advances in medical imaging, simulation, and controllable anatomical analysis. However, existing generative models typically synthesize 3D volumes monolithically, often overlooking regional anatomical structures and limiting local controllability. To address these limitations, we introduce AnaDiffusion, an anatomically compositional latent diffusion framework that factorizes the generation process into distinct, anatomically meaningful regions, followed by part-to-whole assembly and global refinement. Our approach first trains part diffusion models to capture local structural priors. We then inject an assembled anatomical composite of the parts into the whole-brain latent representation and continue denoising. This mechanism enables the model to resolve global context while preserving the injected anatomy. As a result, AnaDiffusion produces both explicit part assets and a globally coherent volume, thereby enabling controllable part editing without requiring subject-specific dense segmentation maps at inference time while maintaining consistent part-to-whole brain structure. On the subject-disjoint ADNI test split, AnaDiffusion achieves the lowest FID across the whole brain, left and right hemispheres, cerebellar-brainstem complex, and seam regions. It also achieves the best cerebellar and second-best ventricular and brainstem absolute Cohen's d values among the evaluated methods. In localized editing experiments, paired MS-SSIM demonstrates high target transfer and off-target preservation, supporting controllable part replacement with minimal unintended anatomical alterations.

Date: August 25, 2026

Code: https://github.com/phai-lab/AnaDiffusion.git

Project Page: https://anadiffusion.github.io/

Affiliation Note: Huiwen Han and Lulin Liu were visiting students at Texas A&M University during this work.

PHAI

1 Introduction

High-fidelity 3D brain MRI generation has become increasingly fundamental for medical imaging problems, where large-scale volumetric data are often costly to acquire, difficult to annotate, and limited by privacy and lack of paired anatomical segmentation. The current synthesis has already benefited a wide range of downstream applications, including cross-modality translation (Kim and Park, 2024), super-resolution (Wang et al., 2023; Khateri et al., 2025), and disease progression simulation (Peng et al., 2023; Dhinagar et al., 2024; Puglisi et al., 2024; Fu et al., 2025). While recent diffusion models (Ho et al., 2020; Rombach et al., 2022) have demonstrated remarkable success in synthesizing globally plausible volumetric data, generating anatomically accurate local structures remains a persistent challenge. Whole-brain samples that appear realistic at a macroscopic scale can exhibit localized anatomical failures—such as blurred tissue interfaces, topological inconsistencies in the cortex, and unnatural asymmetries—as shown in Figure 1. These localized artifacts compromise the downstream utility of the generated data. In practice, they are often exposed by automated segmentation pipelines, which reveal incomplete or structurally inconsistent local anatomy in synthesized volumes (Wu et al., 2024; Deo et al., 2025; Jafrasteh et al., 2025).

These observations highlight the need for 3D MRI generation models that preserve fine-grained anatomical

Figure

Figure 1 AnaDiffusion for anatomically compositional 3D brain MRI generation. Unlike monolithic baselines (left) that may suffer from left-right inconsistency, inter-part discontinuity, and boundary collapse, AnaDiffusion generates part-specific anatomical assets and refines their assembled scaffold into a coherent whole-brain volume. The resulting model generates better regional and global anatomy across FID and SynthSeg-based metrics.

structure, rather than only producing globally plausible brain volumes. Prior methods have introduced explicit structural constraints to improve anatomical plausibility: Geometry-driven approaches utilize deformation fields or surface meshes to encourage globally plausible shapes (Wang et al., 2025; Wu et al., 2025; Wilms et al., 2022; Bongratz et al., 2026; Rusak et al., 2022). Alternatively, a common strategy employs segmentation masks, either as conditioning signals or via supervised objectives, to ensure the generated volumes adhere to a prescribed spatial layout (Wan et al., 2026; Konz et al., 2024; Fernandez et al., 2024). While mask conditioning provides spatial control, it relies on the dense input annotations to dictate structural coherence. The model learns to render intensities within provided boundaries rather than capturing the intrinsic structural relationships and dependencies between adjacent regions. Fundamentally, both mask-conditioned and unconditioned generative strategies typically remain monolithic: they encode and generate the entire volume via a single, entangled latent representation. This uniform treatment struggles with the brain's spatial heterogeneity, where distinct regions (e.g., the highly folded cerebral cortex versus the densely structured cerebellum) exhibit vastly different morphological complexities (Fischl et al., 2002). Consequently, monolithic models often suffer from capacity limits that average out fine-scale, region-specific details, creating a need for a framework that explicitly factorizes local structures while ensuring their coherent integration.

Recognizing this gap, we introduce AnaDiffusion, an anatomy-informed compositional sampling and refinement framework for 3D brain MRI synthesis. Our contribution lies in how explicit regional generators are coupled to an ongoing whole-brain generative trajectory. To this end, we first train part-specific latent diffusion models, allowing the model to devote generative capacity to anatomically heterogeneous regions. For bilateral structures, we further employ a symmetry-aware hemisphere model with canonicalized weight sharing, which encourages anatomically consistent left-right generation while improving data efficiency. Building on these local anatomical priors, we then address the central challenge of part-to-whole integration. We construct an anatomical composite from the generated parts and use it to guide a global whole-brain diffusion process, which harmonizes regional details into a coherent volume. To preserve structural consistency, we train the whole-brain denoiser to resume reverse sampling from assembled composite latents reintroduced at intermediate noise levels. Together, these designs enable AnaDiffusion to preserve high-fidelity local anatomy while maintaining global coherence. AnaDiffusion also produces explicit part-level assets, enabling controllable part replacement at inference time. We summarize our contributions as follows:

• We introduce AnaDiffusion, a compositional latent diffusion framework for controllable 3D brain MRI generation. AnaDiffusion decomposes synthesis into anatomical parts and a whole-brain latent integration process, modeling heterogeneous brain structures more effectively than monolithic whole-volume generation.

  • We propose a part-to-whole latent refinement that integrates independently generated anatomical parts into a coherent whole-brain volume. This supports controllable part replacement while keeping the non-edited brain regions stable and maintaining consistent part-to-whole anatomy.

• Motivated by the functional and structural bilateral symmetry of the human brain, we design a hemisphere generator shared across both hemispheres by employing left-right canonicalization and side-indicator conditioning.

  • We demonstrate that, relative to the compared baselines, AnaDiffusion improves the evaluated synthesis metrics on held-out subjects from a subject-disjoint ADNI test split. It achieves stronger regional distributional fidelity and segmentation-based anatomical alignment, while enabling localized part replacement with high target transfer and limited off-target drift, without requiring subject-specific dense segmentation maps at inference time.

References (50)