arXiv:2611.05206cs.CVNov 2026

Manuscript Offprint

arXiv:2611.05206

Diffusion Plug-in Priors for Self-Supervised Ultrasound Video Restoration

Chu Chen, Mingduo He, Yining Li, Yinhao Wu, Wei Tang, Yiwen Luo, Yixuan Chen, Graham Treece, Pasquale Cascarano, Kangning Cui

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Chu Chen1,∗^{1,*} Mingduo He2,∗^{2,*} Yining Li3,∗^{3,*} Yinhao Wu4^{4} Wei Tang5,6^{5,6}

Yiwen Luo7^{7} Yixuan Chen5^{5} Graham Treece1^{1} Pasquale Cascarano8^{8} Kangning Cui9,10,†^{9,10,\dagger}

1^{1}Department of Engineering, University of Cambridge, Cambridge, UK

2^{2}Department of Biomedical Engineering, School of Life Science and Technology,

Huazhong University of Science and Technology, Wuhan, China

3^{3}Department of Intelligent Medical Engineering, School of Medicine, Nankai University, Tianjin, China

4^{4}University of Texas at Arlington, Arlington, TX, USA

5^{5}Department of Engineering Science, University of Oxford, Oxford, UK

6^{6}Oxford Suzhou Centre for Advanced Research, Suzhou, China

7^{7}Department of Electrical Engineering, City University of Hong Kong, Hong Kong SAR

8^{8}Department of the Arts, University of Bologna, Bologna, Italy

9^{9}Department of Data Science, City University of Hong Kong (Dongguan), Dongguan, China

10^{10}City University of Hong Kong, Hong Kong SAR

*Equal contribution, listed in alphabetical order. †Corresponding author: kangning.cui@cityu-dg.edu.cn

ABSTRACT

Objective: Ultrasound videos are limited by hardware-constrained spatial resolution and signal-dependent speckle, while paired low- and high-resolution acquisitions for supervised restoration are rarely available. We aim to jointly super-resolve and despeckle ultrasound videos without paired training data or network retraining. Methods: We propose UltraDiff, which uses a frozen pre-trained diffusion model (DM) as a plug-in prior and restores each frame by optimizing the latent seed of the DM sampler under a range-constrained maximum a posteriori formulation. We derive a speckle-aware data-fidelity term from a Rayleigh scale-family model and characterize its relative-residual and variance-adaptive weighting properties. We further introduce a stabilized fidelity that is bounded below and strictly convex in log intensity for positive observations in its unclamped form. A total-variation regularizer complements the DM prior, and a temporal seed update warm-starts each frame from the optimized seed of its predecessor. Results: On EchoNet-LVH videos with simulated speckle and additive noise, UltraDiff with a natural-image prior improves PSNR by 1.24 dB over the strongest baseline, and ultrasound-related priors improve it further. On real clinical echocardiography videos, UltraDiff reduces the mean absolute error of zero-shot ejection fraction (EF) prediction from 7.31 to 6.37 EF points relative to DUP, the strongest baseline. Conclusion: Combining a speckle-aware fidelity with frozen diffusion priors enables ground-truth-free ultrasound video restoration that benefits downstream measurement. Significance: UltraDiff needs neither paired data nor retraining and is not tied to a specific diffusion checkpoint. Code associated with this work will be made publicly available upon acceptance.

Keywords ultrasound · video super-resolution · diffusion model · self-supervised learning · despeckling · inverse problems

1 Introduction

Ultrasound (US) imaging is widely used in cardiology [1–3], obstetrics [4,5], and musculoskeletal imaging [6] because it is real-time, non-invasive, and cost-effective. Compared with static US images, US videos capture dynamic tissue motion, which is essential for applications such as breast lesion assessment [7,8] and cardiovascular monitoring [9–11]. In echocardiography, ejection fraction (EF) estimation depends on clear cardiac structures throughout the cardiac cycle.

Figure

Figure 1: Motivating comparison of ultrasound video restoration. We compare reconstructed frames from LR ultrasound sequences with HR references and representative methods, including EDSR, ZSSR-Cycle, and UltraDiff. The zoom-in regions highlight structural details and tissue texture: UltraDiff suppresses noise while better preserving anatomical structures and the tissue echotexture.

Despite these advantages, the quality of US videos is inherently constrained by the physics of acoustic imaging. Spatial resolution is limited by the frequency-penetration trade-off of transducer design, while image quality is further affected by signal-dependent speckle noise caused by the interference of backscattered waves [12]. Classical despeckling methods reduce these fluctuations [12, 13], but must balance noise suppression against the loss of tissue echotexture, which itself carries diagnostic information. These degradations reduce boundary visibility and can compromise downstream measurements such as automated EF prediction. Super-resolution (SR) offers a computational route beyond hardware-limited resolution [14]. However, robust US video restoration remains challenging: paired low-resolution (LR) and high-resolution (HR) US videos are rarely available, acquisition conditions vary across devices and operators, and US noise statistics differ substantially from natural-image degradations. As illustrated in Fig. 1, representative SR baselines either over-smooth cardiac structures or fail to recover realistic tissue texture.

References (45)