Manuscript Offprint
arXiv:2611.00247Taurus: LLM-in-the-Loop CT Annotation Matches Coding Agents at Half the Cost
ABSTRACT
Dense labels of the aorta in CT are slow to draw, and the public aortic CT datasets that could stand in for them each label different structures under their own conventions. Large language model (LLM) agents can now write code and read images. We asked whether such a model labels these scans better as a free-form agent that writes its own segmentation code, or inside a harness, where an automated pass labels the scan and the model reviews the result. We built a harness, Taurus, and compared it with free-form agents by blind label recovery: we withheld the human labels of six public datasets (939 volumes) and scored every approach against each dataset's own classes. In the first version of Taurus, the model's review raised the primary metric on only two of six datasets, by less than the noise between two reviews of the same case. A free-form agent running Claude Opus 5.5 scored higher on most datasets. Moving what the free-form agents did well into the automated pass then carried most of the gain on 38 held-out cases. The final version smooths the label surfaces with a fixed rule and checks for the large errors the automated pass tends to make, such as an aneurysm drawn to half its size. Each check that fires puts a multiple-choice question to the model, with candidate corrections drawn on the scan. It matched the surface smoothness of the human references, and in the primary metric we found no difference from the free-form Opus agent, at under half its cost, 2.71 per case. Most of what made Taurus competitive came from the harness and its automation rather than from the language model itself. Taurus shows that this kind of annotation can be automated, so that expert time can move from drawing labels to checking them.
Keywords Annotation · Large language models · Agents · Aortic CT · Segmentation · Quality control
1 Introduction
Dense labels of the aorta and its branches are the input to aneurysm sizing, endograft planning and the training of segmentation models, but they are slow to draw. Public datasets help less than their number suggests, because each one labels a different subset under its own conventions, from 23 named vessels and zones [1] to a single binary lumen tree [2] (Table 1) [3–6]. Combining them means relabeling them under one label contract, which in this study has four tissue classes (lumen, calcium, thrombus and wall) and 27 vessel labels for the ten aortic zones and the named branches (Section 3.1).
Supervised and promptable segmentation models [7–9] produce good masks for the classes they know, but someone still has to check the output and decide what to fix. Large language model (LLM) agents can now run code, call tools and read images [10, 11], so a model could take over both the labeling and its checking, in one of two ways (Figure 2). A free-form agent receives the scan and

Figure 1: Taurus-hybrid ends the cost-accuracy front on the 38 held-out cases: median primary metric, pooled for description only, against model cost per case.
PREPRINT

Figure 2: Two ways to let a language model label a CT scan. (a) The free-form agent loops through looking, writing code, running it and rendering until it writes the labels and a verdict. (b) The Taurus reviewer (Taurus-hybrid shown) starts from the automated label and works through harness calls, each re-rendering the case, until it records a verdict. (c) What the reviewer sees; the question card offers three outlines of the aneurysm sac (A 121, B 114, C 113 mL), and the reviewer chose B.
a programming environment and writes its own segmentation code. A harness, here our system Taurus, runs an automated pass and then gives the model renders and edit commands, and this model, the Taurus reviewer, decides what is wrong, how to fix it and whether the case needs a human. When the automated pass meets a decision it cannot settle, or one of its checks finds a likely error, the harness puts a multiple-choice question to the reviewer, which we call a question card. For example, a card may show one slice of an aneurysm with three candidate outlines of the sac (121, 114 and 113 mL), and the reviewer answers with a letter that the harness then applies, so the model chooses among prepared fixes instead of drawing them (Figure 2c). We ask which of the two labels better and at what cost, and whether the model's verdict tells a human where to look. Because we had no new expert labels, we used blind label recovery: each approach sees only the CT and is scored against the hidden human labels of six public datasets. These datasets label different structures, so before scoring we convert every output to the classes of the dataset at hand, which we call its label space.
We built three versions of the harness and compared each with free-form agents running the same models. Taurus-base uses fixed thresholds and lets the reviewer only correct what the pass drew, and Taurus-tuned moves the steps with which the free-form agents won into the automated pass. Taurus-hybrid adds a surface regularization, a fixed step that smooths the label surfaces and places the lumen edge at a set fraction of the blood's brightness. It also lets the reviewer refine edges with short programs, and it checks the scored classes for gross errors, each of which it turns into a question card. Most of what made Taurus competitive turned out to be deterministic: the free-form agent's winning steps, once automated, carried most of the held-out gain, and a deterministic regularization made the boundaries as smooth as the references. Given these cards, the model raised the held-out median from 0.65 to 0.81 and left no detectable difference
PREPRINT
Table 1: The six datasets label different structures, from 23 vessel ids to a single envelope mask, and each is scored against its own classes. The reference image shows the human label on one design-set case, and contrast is given over the reviewed cases.
| Reference | Dataset | Human label (type) | Field of view | Contrast | Volumes / reviewed / free-form / held-out | Primary metric |
|---|---|---|---|---|---|---|
| AortaSeg24 [1] | 23 vessel ids (zones 0–9, branches) (voxel label map) | whole body; type-B dissections | CTA | 100 / 100 / 5 / 4 | abdominal vessel macro Dice | |
| Siriapisith AAA/EVAR [3] | envelopea (voxel label map) | 80 mm abdominal crops, 256 × 256 × 64; incl. EVAR | CTA; 10 NC | 520 / 160 / 6 / 12 | outer Dice | |
| AVT [2] | one binary arterial-tree lumen (voxel segmentation) | thorax–pelvis arterial tree | CTA; 1 NC | 55 / 24 / 5 / 4 | tree Dice | |
| VMR [6] | lumen per named vessel (lofted surface models, voxelized) | abdomen (± chest); 16 AAA, 1 healthy | CTA | 17 / 17 / 4 / 4 | per-vessel macro Dice | |
| Jamshidian 4D-CTA [5] | thrombus, sac and wall meshes (finite-element surface meshes, voxelized) | aneurysm-sac crops | CTA | 149b / 39 / 5 / 6 | thrombus Dice | |
| not shown: ND licencec | MosMedData AAA [4, 12] | lumen, calcium (thrombus on 4) (voxel label map) | abdominal aortic segment (104–209 mm) | CTA | 98 / 98 / 5 / 8 | lumen + calcium mean Dice |
| Total | 939 / 438 / 30 / 38 | |||||
<sup>a</sup>the envelope is one mask that covers the whole aneurysm, lumen, thrombus and wall, out to its outer surface. <sup>b</sup>cardiac phases of 20 patients, scored per phase. <sup>c</sup>the no-derivatives (ND) term of its CC BY-NC-ND 3.0 licence does not allow transformed images. Reviewed = cases with a Taurus-base verdict (main experiment); free-form = main cases run by the free-form agents; held-out = the evaluation cases of the held-out comparison. NC = non-contrast among the reviewed cases. VMR image data © Stanford University, the Regents of the University of California, Open Source Medical Software Corporation, and other parties.
from the free-form agent, at under half its cost (Figure 1). Its verdict, however, was a weak signal of failure, and models trained on labels from Taurus-base fell well short of models trained on human labels.
SWE-agent showed that the interface an agent works through changes how well a fixed model solves a task [11], and a harness is such an interface for annotation. In medicine, vision-language models answer questions about images [30, 31], agents call imaging tools [32–34], and language models serve as annotators and judges [35, 36]. Recent agents also drive promptable segmenters directly [37, 38], whereas we study a model that reviews and edits the output of a deterministic labeler and compare it with an agent that writes its own code. The closest evaluation asks multimodal models whether 2D segmentation overlays are acceptable [39], and we know of no study that gives an agent dense 3D CT labeling end to end and measures it against independent human labels together with its cost. Segmentation quality can also be predicted without ground truth [40–42], and we test the reviewer's verdict as such a prediction.
3 Method
Taurus runs an automated pass, which proposes the vessels, grows the trunk and sac, assigns the tissue classes, names the branches and zones and raises quality flags, and then renders its labels for the Taurus reviewer. This reviewer is an LLM session that edits the labels only through a fixed set of edit commands and closes each case with one of three verdicts: ok, fixed or issue, the last meaning that the case needs a human (Figure 2b). Reviewers read the harness guide (Section G) and see only the images that harness commands return.
PREPRINT
Table 2: The harness toolkit and the Taurus versions that have each tool (✓: yes; (✓): in limited form; -: no).
| Tool | What it does | Taurus-base | Taurus-tuned | Taurus-hybrid |
|---|---|---|---|---|
| Automated pass | ||||
| Proposal | AI segmentation models (vessel model, whole-body organ model) or a bright core propose the aorta and branches | ✓ | ✓ | ✓ |
| Trunk and sac growth | grows the trunk and sac; Taurus-tuned and Taurus-hybrid add a trunk tracker and a contour out to the aneurysm's outer surface, where its wall meets the surrounding fat; Taurus-hybrid re-seeds the trunk when the labeled lumen is implausibly small or a brighter tube is left unlabeled, and checks the sac against a polar edge finder | ✓ | ✓ | ✓ |
| Tissue classes | lumen, calcium, thrombus and wall from thresholds, which are fixed in Taurus-base and measured on the case in Taurus-tuned and Taurus-hybrid; Taurus-hybrid drops calcium that lies on the vertebral cortex | ✓ | ✓ | ✓ |
| Branches, zones, flags | traces branches from the wall, names them and the aortic zones, raises quality warnings; Taurus-hybrid adds warnings for a rebuilt trunk, an under-sized sac, calcium specks and a header orientation that contradicts the anatomy | ✓ | ✓ | ✓ |
| What the reviewer sees | ||||
| Renders | review image, vessel map, branch strips, zoomed slices; attenuation probes from Taurus-tuned on | ✓ | ✓ | ✓ |
| Dossier and cards | measurements as text; decisions posed as candidate masks to choose from; Taurus-hybrid adds cards for the sac extent, calcium specks, a rebuilt trunk and the orientation, each stating its stake in the dataset's scored classes | - | ✓ | ✓ |
| Edit commands | ||||
| Paint, erase, clear | local corrections of any class, removal of detached pieces | ✓ | ✓ | ✓ |
| AI outer growth | click-seeded growth of the outer boundary with the interactive 3D segmenter | ✓ | ✓ | ✓ |
| Lumen threshold | case-wide lower lumen threshold and lumen growth from a seed | ✓ | ✓ | ✓ |
| Sac growth, exclusion | grows the sac out to the surrounding fat, interpolates between slices, excludes drawn regions | - | ✓ | ✓ |
| Trunk rebuild | re-tracks the trunk from a seed | - | ✓ | ✓ |
| Branch edits | add, extend, remove and rename vessels | ✓ | ✓ | ✓ |
| Regularization | when the case is claimed, moves the lumen edge to 0.6 times blood attenuation, smooths the outer surface and redraws the wall as a thin ring | - | - | ✓ |
| Prepared and own programs | prepared programs, written and tested in advance, such as mask smoothing, edge refinement, branch tracing or the polar sac finder (19 in Taurus-hybrid), or the reviewer's own short programs | - | (✓) | ✓ |
| Undo and verdict | undo any edit; ok, fixed or issue with codes; reference-disagreement notes in Taurus-hybrid | ✓ | ✓ | ✓ |
3.1 Taurus: LLM-in-the-Loop Annotations
Taurus comes in three versions, Taurus-base, Taurus-tuned and Taurus-hybrid, which share the automated-pass stages, the renders, the verdict and the segmentation models. A version's name alone denotes its reviewed output, and "(auto)" marks the automated pass alone, as in Taurus-base (auto). In Taurus-base, the automated pass uses fixed thresholds, and the reviewer can only correct what the pass drew, by painting or erasing a region, growing the outer boundary from a click, editing branches or lowering the lumen threshold, but cannot re-run the sac growth or the trunk tracking. We built Taurus-tuned by moving what the free-form agents did well into the automated pass: it measures blood attenuation for its thresholds, draws the aneurysm contour out to its outer surface, tracks the trunk from a seed, and poses decisions as question cards with candidate masks.
Taurus-tuned labeled accurately but drew stair-stepped surfaces, and its reviewer wrote code of its own only 4 times in 38 cases. We built Taurus-hybrid in two steps, the first of which kept the automated pass of Taurus-tuned and changed the review to close this surface gap at low cost. When the reviewer claims a case, a deterministic regularization moves the lumen edge to 0.6 times the measured blood attenuation, smooths the outer surface and redraws the wall as a thin ring. We chose the 0.6 level on references outside the held-out set only. In a second review phase, the reviewer inspects the edges on zoomed slices and may refine them with prepared programs, most of which were distilled from code that Free-form Opus wrote, or with short programs of its own (Table 2). After every edit the reviewer compares the same zoomed slice before and after and undoes the edit if the edge did not move closer to the CT boundary, while the harness itself refuses only edits that remove too much.
The first build matched the references' smoothness but trailed Free-form Opus on the held-out cases. The gap sat in a few gross errors in the scored classes, a trunk placed on the spine, sacs drawn to half their extent and calcium specks on calcium-free scans (Section 4.2). The second build, the Taurus-hybrid of this paper, adds automated checks for these errors and turns each into a question card with a candidate fix. All three checks were ported from what Free-form Opus had done in its transcripts. Each card states its stake in the dataset's scored classes, and the guide tells the reviewer to check those classes at the gross level before any edge work. The budget was raised to about 60 turns, 32 image opens and 28 edits to match what Free-form Opus spent per case. Table 2 lists the toolkit of each version, and Figure 2c shows what the reviewer is given to see.
PREPRINT

Figure 3: Example labels from the design set, one case per dataset among the 30 free-form cases. Rows show the human reference, Free-form Opus, Taurus-tuned (auto) (Taurus-tuned was not reviewed on these cases) and Taurus-hybrid on the CT, with the reference contour as a white line, vessel ids in segment colors and each case's primary metric in the corner. AortaSeg24, AVT and VMR are shown as a coronal projection with an axial slice through the trunk and its branches. The Siriapisith AAA/EVAR reference is an envelope, one mask that covers the whole aneurysm, lumen, thrombus and wall, out to its outer surface. For AortaSeg24 and Jamshidian 4D-CTA we show the case with the median primary metric of the first hybrid build, and for Siriapisith AAA/EVAR, AVT and VMR the case with its largest margin over Free-form Opus. The Free-form Opus label volumes of the other design-set cases were not kept, so the cases of the first build are shown. MosMedData AAA is not shown, because its licence (CC BY-NC-ND 3.0) does not allow transformed images. VMR data © Stanford University, the Regents of the University of California, Open Source Medical Software Corporation, and other parties.
3.2 Blind Label Recovery
To keep every approach blind, we built for each dataset a copy that holds only the CT volumes, while the human labels stay with the scorer. The starting vessels come from our nnU-Net [7] vessel model, applied out-of-fold on AortaSeg24 where it was trained, or from TotalSegmentator [8] (Section A). Every approach writes two maps under one label contract: a tissue map with lumen, calcium, thrombus and a generated wall shell, and a vessel map with 27 labels, the ten aortic zones and the named branches (Section A).
Datasets. We used six public datasets, AortaSeg24, the Aortic Vessel Tree (AVT), Siriapisith AAA/EVAR, MosMed-Data AAA, Jamshidian 4D-CTA and the Vascular Model Repository (VMR), whose sources and full names are given in Table 1 and Section A. Their human labels cover different structures, from 23 named vessels and zones in AortaSeg24 to a single envelope in Siriapisith AAA/EVAR, one mask that covers the whole aneurysm, lumen, thrombus and wall, out to its outer surface.
Held-out design. We tested Taurus-tuned on 38 held-out cases that its development never touched, fixed before we read any transcript: 26 hard cases, on which Taurus-base scored in the bottom quartile of its primary metric on that dataset, and 12 typical cases from its 40th–60th percentile. Development used the 30 free-form cases, 8 learning cases and one in-house scan (Section A), and the sessions that extracted what worked from the transcripts saw no held-out case. Because the hard cases were chosen for a low Taurus-base score, we re-ran and re-reviewed Taurus-base on them as a paired control. Taurus-tuned and the first hybrid build start from the same frozen Taurus-tuned (auto) labels.
PREPRINT
Table 3: On the held-out cases, Taurus-hybrid was ahead of both free-form agents on five of six datasets, and Free-form Sonnet led on AVT, where the automated pass found no usable trunk. Median primary metric per dataset (each in its own metric, so the pooled column is descriptive) and over all 38 cases, and model cost and minutes per case; for Taurus the minutes include the vessel proposal and the automated pass (Section E). Bold marks the highest median of the column, and asterisks mark medians that rest on two near-empty labels and on the calcium scoring convention (Section 4.2). Spreads, the hard and typical cases and turns are in Table 6.
| Approach | Primary metric per dataset | All | Per case | ||||||
|---|---|---|---|---|---|---|---|---|---|
| AortaSeg24 (4) | Siriapisith AAA/EVAR (12) | MosMedData AAA (8) | AVT (4) | VMR (4) | Jamshidian 4D-CTA (6) | all (38) | $ | min | |
| Taurus-base (auto) | 0.572 | 0.496 | 0.021 | 0.027 | 0.490 | 0.002 | 0.321 | – | 0.7 |
| Taurus-base | 0.579 | 0.496 | 0.024 | 0.432 | 0.492 | 0.004 | 0.410 | 0.20 | 1.5 |
| Taurus-tuned (auto) | 0.732 | 0.783 | 0.462 | 0.437 | 0.464 | 0.534 | 0.620 | – | 1.0 |
| Taurus-tuned | 0.732 | 0.871 | 0.462 | 0.437 | 0.466 | 0.572 | 0.704 | 0.75 | 6.4 |
| Taurus-hybrid (auto) | 0.734 | 0.791 | 0.468 | 0.454 | 0.468 | 0.587 | 0.647 | – | 1.1 |
| Taurus-hybrid | 0.733 | 0.897 | 0.853 | 0.442 | 0.483 | 0.732 | 0.805 | 1.22 | 6.4 |
| Free-form Sonnet | 0.307 | 0.802 | 0.773* | 0.823* | 0.226 | 0.430 | 0.677 | 0.18 | 1.3 |
| Free-form Opus | 0.629 | 0.892 | 0.837 | 0.466* | 0.446 | 0.715 | 0.802 | 2.71 | 16.1 |
Free-form Sonnet and Free-form Opus ran on all 38 cases. Taurus-hybrid, however, is not a blind test: we designed its first build after seeing the held-out results of Taurus-tuned, and its second build after reading the held-out transcripts of the first build and of Free-form Opus to find where they differed. We tuned the checks and cards on development cases only, and the held-out cases were run once. Its held-out results therefore show what such guidance can achieve rather than how a fixed design generalizes.
3.3 Evaluations
Outputs are converted to each dataset's classes, its label space, and scored with one primary metric per dataset (Table 1), and the study plan fixed these metrics and the scored region before the first run. Four datasets are scored within a margin of the human label, so that structures the reference never covered do not count as errors (Section A). On MosMedData AAA, the mean of lumen and calcium Dice skips a class absent from both maps, so a few calcium voxels in a calcium-free case halve it.
Metrics. The Dice coefficient [43] measures the overlap of two masks, from 0 when they share no voxel to 1 when they are identical, and macro Dice averages it over the classes present in either mask. Because Dice is insensitive to boundary errors on large structures, we also report the normalized surface distance (NSD) at 1 mm [44], the mean surface distance (MSD) and the 95th-percentile Hausdorff distance (HD95) [45] over the primary-metric classes. The terracing index, the mean deviation of each axial slice's contour from the mean of its two neighbors, measures slab-like steps in a surface. The lumen edge level is the attenuation at which a label places the lumen boundary, as a fraction of blood attenuation, and we compute both measures on the reference too.
To judge the verdict, we call a case failed when its primary metric is below the 25th percentile of the dataset's Taurus-base values. We report the area under the ROC curve (AUROC) [46] of the binary issue verdict, of the harness ranking and of the quality flags alone. Cohen's [47] compares two reviews of the same case, and a replay scores every saved label version, counting an edit as an improvement or a harm when the primary metric moves by at least 0.005.
Statistics and cost. Paired comparisons use the Wilcoxon signed-rank test [48] with bootstrap 95 % confidence intervals (CI) over 1,000 resamples [49]. Tests in the main experiment stay within a dataset and are Holm-adjusted [50], while held-out tests pool the 38 cases and are unadjusted, and medians pooled over datasets are descriptive only. Two reviews of the same case by the same model tier differ with a standard deviation of 0.020, so we treat per-case differences below 0.040 as run-to-run noise and call 0.040 the noise floor. Costs are model costs per case in US dollars, computed from the token counts of each run as described in Section E.
4 Results
We report the main experiment and the held-out comparison, with the paired statistics in Table 4. In a third experiment, segmentation models trained on Taurus-base labels reached a primary metric of 0.699 on Siriapisith AAA/EVAR and 0.522 on MosMedData AAA, against 0.975 and 0.804 when trained on human labels (Section F).
PREPRINT

g held-out, hard cases (n = 26)
h held-out, typical cases (n = 12)

Figure 4: Review raised Taurus-base on two datasets by small amounts; on the held-out cases Taurus-tuned (auto) carried the gain of Taurus-tuned, and the cards that of Taurus-hybrid. Primary metric per approach. (a–f) Main experiment per dataset (marker: median, bar: interquartile range, dots: cases), including Taurus-hybrid on the 30 free-form cases, which are design-set cases for it. Each panel uses its dataset's own metric and label space, so values are not comparable across panels. (g, h) Held-out hard and typical cases, each in its own dataset's metric and pooled for description only. Horizontal bars and numbers are medians.
Free-form Baseline. The free-form agent uses the same models without the harness: Claude Sonnet 5.5 for Free-form Sonnet and Claude Opus 5.5 for Free-form Opus. It works in a sandbox that holds the CT, the label contract and a task description, but no harness code, no trained model and no other case (Section G). Each case gets one scored run, a run without valid output scores zero, and since only Taurus has trained models, the comparison is also one of tools.
In the main experiment, Taurus-base (auto) ran on all 939 volumes and Taurus-base on 438 sampled cases. The free-form agents ran on 30 of these, four to six per dataset, and Taurus-hybrid later reviewed the same 30 cases with its final guide, which makes them design-set cases for it (Figure 3). Reference-seeded (not blind), which runs Taurus with the dataset's own labels as priors, bounds the loss that comes from mapping between label spaces.
4.1 LLM-in-the-Loop Annotation Review
Review raised the median primary metric of Taurus-base on two of six datasets by small but consistent amounts, 0.013 in outer Dice on Siriapisith AAA/EVAR and 0.022 in tree Dice on AVT, both below the noise floor for a single case (Figure 4). Free-form Opus did better than Taurus-base on most cases of four datasets, tied on VMR and did worse on all five AortaSeg24 cases, but with four to six cases per dataset no difference survived Holm correction (Table 5). Most other losses of Taurus-base came from 17 of 98 MosMedData AAA scans, whose header contradicted the anatomy and put the proposal on the spine, and from under-grown thrombus on the Jamshidian 4D-CTA phases. The automated pass either worked or failed outright, which explains the wide ranges in Figure 4. MosMedData AAA scans with a flipped header, and Siriapisith AAA/EVAR crops where the pass missed the sac or found no aorta, scored near 0, far below the other cases.
On the 30 design-set cases, Taurus-hybrid did better than Free-form Opus, with a paired median lead of 0.027 in the primary metric (21 better, 6 worse; p = 0.001, unadjusted). The lead in NSD at 1 mm was larger, 0.095 (23/6; p < 0.001), and it came at 4.47. It led clearly on AortaSeg24, with an abdominal vessel macro Dice of 0.784 against 0.579, and on the Jamshidian 4D-CTA phases (5/0). It differed little from Free-form Opus on AVT
PREPRINT

bar = median; dashed = the reference's own median; values beyond an axis are drawn at its edge
Figure 5: The regularization smoothed the surfaces. Boundary and surface quality against the human reference on the 38 held-out cases: NSD at 1 mm, MSD (log scale), terracing index and lumen edge level per approach. Bars are medians, dots are cases, and points beyond an axis are drawn at its edge. The dashed lines mark the reference's own median terracing and lumen edge level.
and the Siriapisith AAA/EVAR crops and trailed on MosMedData AAA (2/3), where the gap came from the calcium artifact (Section 3.3).
4.2 Learning Automation from Free-Form Annotations
On the held-out cases, Taurus-tuned (auto) exceeded Taurus-base (auto) by a paired median of 0.258 (Figure 4g–h, Table 3). Review on top of Taurus-tuned (auto) changed only 12 of the 38 cases, and a second review of Taurus-base (auto) also changed 12. In Taurus-tuned the gain therefore came from the automated pass, which applies as fixed rules the steps that the free-form agents had worked out for each dataset. The first hybrid build changed little more: its review moved the paired median by 0.001 and the pooled median from 0.647 to 0.716 (Table 4).
In Taurus-hybrid, by contrast, the review carried the gain, through the cards: the pooled median rose from 0.647 for Taurus-hybrid (auto) to 0.805, with 24 cases improved and 5 worse (paired median +0.025; ; Table 3). The reviewers took the sac finder's contour on 9 cases, cleared the calcium specks on 5 and rebuilt the trunk out of the vertebral canal on the header-flipped MosMedData AAA scan. The largest gains came on MosMedData AAA, where every calcium-free scan was left calcium-free, on the Siriapisith AAA/EVAR crops and on the Jamshidian 4D-CTA phases. Taurus-hybrid was higher than Taurus-tuned by a paired median of 0.021 (26 better, 5 worse; ) and than its first build by 0.009 (21/6; ).
On the held-out cases we found no difference between Taurus-hybrid and Free-form Opus: the pooled medians were 0.805 and 0.802, and the paired difference was +0.006 (20 better, 18 worse; ). The boundary and surface measures did not differ either, except NSD at 1 mm, where Taurus-hybrid led (Table 4). Per dataset, Taurus-hybrid led on five and trailed on AVT (Table 3), with its largest lead on AortaSeg24, where Free-form Opus confuses branch identities. The largest differences in either direction were MosMedData AAA scans, where a few calcium voxels decide the score. Scored on the classes present in the reference only, Free-form Opus reaches a pooled median of 0.846 while Taurus-hybrid stays at 0.805, but the paired difference is (17/21; ), so neither convention separates the two. The lead of Taurus-hybrid on MosMedData AAA under the primary metric comes from the calcium-specks card, which its guide tells the reviewer to check.
The lead of Free-form Sonnet on AVT, marked in Table 3, comes from robustness rather than better segmentation. On two AVT scans without usable contrast for the trunk tools, every Taurus approach scored below 0.04, because the automated pass left an almost empty label. The hard cases were chosen from Taurus-base failures, so they over-represent input failures that a free-form agent, which reads the CT directly, does not share, and in the main experiment Free-form Sonnet never led a case by more than the noise floor. Over all held-out cases, Taurus-hybrid was higher than Free-form Sonnet by a paired median of 0.073 (28/10, ).
PREPRINT

Figure 6: Taurus-base misses the sac or thrombus, Taurus-tuned restores them with slab terraces, and Taurus-hybrid removes the terraces. Mesh-to-mesh comparison with the human reference on three held-out cases: (a) the AortaSeg24 vessel tree, (b) a Siriapisith AAA/EVAR outer envelope, (c) a Jamshidian 4D-CTA thrombus. The upper row shows each approach's surface. The row beneath colors it by signed distance to the reference, blue inside and red outside on a fixed ±3 mm scale, with the reference translucent. The Human column prints the reference's own terracing index, and the others print the primary metric and the MSD.
5 Discussion
The free-form agent and Taurus win on different tasks, and the reasons are mechanical. Where the task is one vessel and its sac, Free-form Opus beat Taurus-base, because it measured blood attenuation before choosing a threshold, traced the sac out to the fat and tracked the trunk from a seed, where Taurus-base used fixed rules. None of these steps needs a language model, and once automated they carried most of the held-out gain. After tuning, Taurus still differed from the free-form agent in terracing and, on AVT, in the lumen edge, which sat at 0.34 times blood attenuation where the references sit at 0.72, and a deterministic regularization removed both differences. What remained were gross errors in the scored classes, and the model fixed them once the harness had found them, shown them on a card and prepared the fix. The same reviewer that changed 12 cases in Taurus-tuned changed 29 in Taurus-hybrid, so the model's contribution is real, but it is the judgment to accept or refuse a candidate rather than the segmentation itself.
As a signal of label quality, the model's judgment was narrower still. The issue verdict separated failed from acceptable labels well only where the failure was gross. Its AUROC was 0.82 on MosMedData AAA, where all 17 header-flipped cases received it, and 0.85 on VMR, but 0.50 to 0.63 on the other four datasets. Two reviews of the same case agreed little across model tiers (, 54 cases) and only fairly within a tier (, 24 cases). A human who checks only the flagged cases would therefore miss most subtle failures. Some disagreements are probably errors in the references: auditing 26 cases outside the held-out set, we found Jamshidian 4D-CTA thrombus meshes on enhanced blood and AortaSeg24 references that leave 2–4 cm above the valve unlabeled (other open failures are listed in Table 8). Every number here treats the reference as the truth, so a label that is better than its reference counts as worse.
Boundary Regularization Improves Performance. The regularization alone made Taurus-tuned (auto) smoother, lowering its terracing from 0.71 to 0.50 mm while the primary metric changed by 0.005, below the noise floor (Figure 5). Taurus-hybrid brought terracing below the reference's own, 0.38 against 0.47 mm, and raised the lumen edge level from 0.52 to 0.60, the references' level by construction (Table 7). The error maps of Figure 6 show the change on a
PREPRINT

Figure 7: Most edits of the Taurus-base reviewers left the primary metric unchanged, and two commands carried the gain. Replay of the Taurus-base edits in the main experiment: for each edit command and dataset, the share of measured edits that raised (blue) or lowered (red) the case's primary metric by at least 0.005. Numbers are measured edits, and faint bars have fewer than five. ai-outer grows the outer boundary with the interactive segmenter, and set-lumen-low lowers the lumen threshold.
Siriapisith AAA/EVAR crop, where Taurus-tuned and the first build lie inside the reference over much of the sac and Taurus-hybrid lies just outside it.
Cost and the Impact of Edits. Free-form Opus cost 4 to 33 times as much as a Taurus-base review, and on the 38 held-out cases Taurus-hybrid cost a median of 2.71 for Free-form Opus, in 40 % of the minutes from scan to label and a third of the turns (Tables 3 and 6). The saving comes from fewer and cheaper turns, because a reviewer answers a few precise questions while a free-form agent writes and debugs a pipeline. Most edits of the Taurus-base reviewers left the primary metric unchanged, and most of the gain came from two edit commands, outer growth with the interactive segmenter on Siriapisith AAA/EVAR and the lower lumen threshold on AVT (Figure 7). Free-form Sonnet was the cheapest approach that uses a language model, at $0.18 and 1.3 minutes per held-out case, and it lies on the cost-accuracy front (Figure 1). It could serve as a cheap first pass or as a fallback where the automated pass fails.
Limitations. No expert adjudicated the outputs, the edits or the reference-disagreement notes, and we did not measure expert correction time, so every gain is measured against the references rather than against clinical acceptability. The free-form comparison is narrow: the free-form agents ran once per case without the trained models that Taurus has, and we did not run a free-form agent with the same tools or Taurus with Sonnet, so the gap in cost and accuracy may be narrower for an agent equipped like the harness. Taurus-hybrid is not a blind test: the paired controls correct for the regression to the mean of the hard cases, but not for the fact that Taurus-tuned and Taurus-hybrid were designed around their failure modes. Analysis choices also shape the results: the AUROC values depend on the relative failure threshold, and the per-dataset scores on the scored region (Section A). Labels from Taurus-tuned and Taurus-hybrid are still untested as training data (Section F). Dollars understate the reviews by 3–6 % and exclude the automated pass and the engineering of the harness, so the cost advantage holds for model cost only (Section E).
6 Conclusion
Moving what the free-form agents did well into the automated pass of Taurus-tuned carried most of the gain. Taurus-hybrid, whose cards point the reviewer at the gross errors that remained, then brought surfaces to the references' own smoothness and showed no difference from Free-form Opus on the 38 held-out cases at under half of its cost. The model's own verdict, however, remained a weak signal of failure. Most of what made Taurus competitive therefore came from the harness, its automation and the tools that speed up the model's work, rather than from the language model itself. Free-form agents are most useful at the start of such a project, where their transcripts show what to automate.
For annotation pipelines, the lesson is to automate what a strong agent does deterministically, to ask the model only what needs judgment, and to let it write code under checks where the tools stop. Built this way, a harness makes relabeling public datasets to one label contract cheap, at about a dollar of model cost per case, but expert time is still needed to adjudicate the recovered labels before models can be trained on them (Section F). Taurus shows that this kind of annotation can be automated, and making its labels good enough to train on is the work that remains.
PREPRINT
Data availability
All six datasets are public, and we used each under its own licence: AortaSeg24 [1], AVT [2], Siriapisith AAA/EVAR [3], the Jamshidian 4D-CTA dataset [5], the Vascular Model Repository (https://www.vascularmodel1.com) [6] and MosMedData AAA [4]. MosMedData AAA was created by Yu. A. Vasilev, M. R. Kodenko, A. V. Solovev, O. V. Omelyanskaya, E. P. Yasakova and D. V. Gatin at the Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Health Care Department (Copyright © 2020), is available at https://mosmed.ai/datasets/ and is licensed under CC BY-NC-ND 3.0 (https://creativecommons.org/licenses/by-nc-nd/3.0/). We report scores on MosMedData AAA but show no images from it. VMR image data in Table 1 and Figure 3 are © Stanford University, the Regents of the University of California, Open Source Medical Software Corporation, and other parties. We do not redistribute any of the datasets, and we do not release labels derived from MosMedData AAA or VMR. The in-house scan used only during development is not public. The harness code, the other derived labels and the result files are available from the authors on reasonable request, subject to the dataset licences.
Acknowledgements
The VMR data used herein was provided in whole or in part with Federal funds from the National Library of Medicine under Grant No. R01LM013120, and the National Heart, Lung, and Blood Institute, National Institutes of Health, Department of Health and Human Services, under Contract No. HHSN268201100035C.
Use of AI tools
Claude language models (Anthropic) are the subject of this study and were also used as tools in it. The authors checked the code, the numbers and the text and take responsibility for the content.
References
[1] Muhammad Imran, Jonathan R. Krebs, Vishal Balaji Sivaraman, Teng Zhang, Amarjeet Kumar, Walker R. Ueland, et al. Multi-class segmentation of aortic branches and zones in computed tomography angiography: The AortaSeg24 challenge. Medical Image Analysis, 113:104188, 2026. doi: 10.1016/j.media.2026.104188. arXiv:2502.05330.
[2] Lukas Radl, Yuan Jin, Antonio Pepe, Jianning Li, Christina Gsaxner, Fen-hua Zhao, and Jan Egger. AVT: Multicenter aortic vessel tree CTA dataset collection with ground truth segmentation masks. Data in Brief, 40:107801, 2022. doi: 10.1016/j.dib.2022.107801.
[3] Thanongchai Siriapisith, Worapan Kusakunniran, and Peter Haddawy. A retrospective study of 3D deep learning approach incorporating coordinate information to improve the segmentation of pre- and post-operative abdominal aortic aneurysm. PeerJ Computer Science, 8:e1033, 2022. doi: 10.7717/peerj-cs.1033.
[4] Yu. A. Vasilev, M. R. Kodenko, A. V. Solovev, O. V. Omelyanskaya, E. P. Yasakova, and D. V. Gatin. MosMedData: CT angiography dataset with signs of calcification, thrombosis, dilatation and aneurysm, with segmentation of the lumen and wall of the abdominal aorta, type VII. Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Health Care Department; database registration certificate No. 2024621990, Russian Federation, 2024. URL https://mosmed.ai/datasets/. Version 1.0.0, released 18 June 2024, CC BY-NC-ND 3.0.
[5] Mostafa Jamshidian, Adam Wittek, Saeideh Sekhavat, Farah Alkhatib, Jens Carsten Ritter, Paul M. Parizel, Donatien Le Liepvre, Florian Bernard, Ludovic Minvielle, Antoine Fondanèche, Jane Police, Christopher Wood, and Karol Miller. 4D-CTA image and geometry dataset for kinematic analysis of abdominal aortic aneurysms. Data in Brief, 61:111797, 2025. doi: 10.1016/j.dib.2025.111797.
[6] Nathan M. Wilson, Ana K. Ortiz, and Allison B. Johnson. The Vascular Model Repository: A public resource of medical imaging data and blood flow simulation results. Journal of Medical Devices, 7(4):040923, 2013. doi: 10.1115/1.4025983.
[7] Fabian Isensee, Paul F. Jaeger, Simon A. A. Kohl, Jens Petersen, and Klaus H. Maier-Hein. nnU-Net: a self-configuring method for deep learning-based biomedical image segmentation. Nature Methods, 18(2):203–211, 2021. doi: 10.1038/s41592-020-01008-z.
PREPRINT
[8] Jakob Wasserthal, Hanns-Christian Breit, Manfred T. Meyer, Maurice Pradella, Daniel Hinck, Alexander W. Sauter, Tobias Heye, Daniel T. Boll, Joshy Cyriac, Shan Yang, Michael Bach, and Martin Segeroth. TotalSegmentator: Robust segmentation of 104 anatomic structures in CT images. Radiology: Artificial Intelligence, 5(5):e230024, 2023. doi: 10.1148/ryai.230024.
[9] Fabian Isensee, Maximilian Rokuss, Lars Krämer, Stefan Dinkelacker, Ashis Ravindran, Florian Stritzke, Benjamin Hamm, Tassilo Wald, Moritz Langenberg, Constantin Ulrich, Jonathan Deissler, Ralf Floca, and Klaus Maier-Hein. nnInteractive: Redefining 3D promptable segmentation, 2025.
[10] Shunyu Yao, Jeffrey Zhao, Dian Yu, Nan Du, Izhak Shafran, Karthik Narasimhan, and Yuan Cao. ReAct: Synergizing reasoning and acting in language models. In International Conference on Learning Representations (ICLR), 2023. arXiv:2210.03629.
[11] John Yang, Carlos E. Jimenez, Alexander Wettig, Kilian Lieret, Shunyu Yao, Karthik Narasimhan, and Ofir Press. SWE-agent: Agent-computer interfaces enable automated software engineering. In Advances in Neural Information Processing Systems, volume 37, pages 50528–50652, 2024. doi: 10.52202/079017-1601. arXiv:2405.15793.
[12] Maria R. Kodenko, Yuriy A. Vasilev, Alexander V. Solovev, Denis V. Gatin, Elena P. Yasakova, Anastasia V. Guseva, and Roman V. Reshetnikov. CT angiography dataset with abdominal aorta segmentation. Digital Diagnostics, 6(1):23–32, 2025. doi: 10.17816/DD635589.
[13] Fabian Isensee, Tassilo Wald, Constantin Ulrich, Michael Baumgartner, Saikat Roy, Klaus Maier-Hein, and Paul F. Jäger. nnU-Net revisited: A call for rigorous validation in 3D medical image segmentation. In Medical Image Computing and Computer Assisted Intervention – MICCAI 2024, volume 15009 of Lecture Notes in Computer Science, pages 488–498, Cham, 2024. Springer. doi: 10.1007/978-3-031-72114-4_47. arXiv:2404.09556.
[14] Bastian Wittmann, Yannick Wattenberg, Tamaz Amiranashvili, Suprosanna Shit, and Bjoern Menze. vesselFM: A foundation model for universal 3D blood vessel segmentation. In Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR), pages 20874–20884, 2025. doi: 10.1109/CVPR52734.2025.01944. arXiv:2411.17386.
[15] Alexander Kirillov, Eric Mintun, Nikhila Ravi, Hanzi Mao, Chloe Rolland, Laura Gustafson, Tete Xiao, Spencer Whitehead, Alexander C. Berg, Wan-Yen Lo, Piotr Dollár, and Ross Girshick. Segment anything. In Proceedings of the IEEE/CVF International Conference on Computer Vision (ICCV), pages 3992–4003, 2023. doi: 10.1109/ICCV51070.2023.00371. arXiv:2304.02643.
[16] Nikhila Ravi, Valentin Gabeur, Yuan-Ting Hu, Ronghang Hu, Chaitanya Ryali, Tengyu Ma, Haitham Khedr, Roman Rädle, Chloe Rolland, Laura Gustafson, Eric Mintun, Junting Pan, Kalyan Vasudev Alwala, Nicolas Carion, Chao-Yuan Wu, Ross Girshick, Piotr Dollár, and Christoph Feichtenhofer. SAM 2: Segment anything in images and videos. In International Conference on Learning Representations (ICLR), 2025. URL https://proceedings.iclr.cc/paper_files/paper/2025/hash/45c1f6a8cbf2da59ebf2c802b4f742cd-Abstract-Conference.html. arXiv:2408.00714.
[17] Jun Ma, Yuting He, Feifei Li, Lin Han, Chenyu You, and Bo Wang. Segment anything in medical images. Nature Communications, 15:654, 2024. doi: 10.1038/s41467-024-44824-z.
[18] Hallee E. Wong, Marianne Rakic, John Guttag, and Adrian V. Dalca. ScribblePrompt: Fast and flexible interactive segmentation for any biomedical image. In Computer Vision – ECCV 2024, Part XL, Lecture Notes in Computer Science, pages 207–229, Cham, 2024. Springer. doi: 10.1007/978-3-031-73661-2_12. arXiv:2312.07381.
[19] Haoyu Wang, Sizheng Guo, Jin Ye, Zhongying Deng, Junlong Cheng, Tianbin Li, Jianpin Chen, Yanzhou Su, Ziyan Huang, Yiqing Shen, Bin Fu, Shaoting Zhang, and Junjun He. SAM-Med3D: A vision foundation model for general-purpose segmentation on volumetric medical images. IEEE Transactions on Neural Networks and Learning Systems, 36(10):17599–17612, 2025. doi: 10.1109/TNNLS.2025.3586694. arXiv:2310.15161.
[20] Yuxin Du, Fan Bai, Tiejun Huang, and Bo Zhao. SegVol: Universal and interactive volumetric medical image segmentation. In Advances in Neural Information Processing Systems, volume 37, pages 110746–110783, 2024. doi: 10.52202/079017-3516. arXiv:2311.13385.
[21] Yufan He, Pengfei Guo, Yucheng Tang, Andriy Myronenko, Vishwesh Nath, Ziyue Xu, Dong Yang, Can Zhao, Benjamin Simon, Mason Belue, Stephanie Harmon, Baris Turkbey, Daguang Xu, and Wenqi Li. VISTA3D: A unified segmentation foundation model for 3D medical imaging. In Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR), pages 20863–20873, 2025. doi: 10.1109/CVPR52734.2025.01943. arXiv:2406.05285.
[22] Andres Diaz-Pinto, Sachidanand Alle, Vishwesh Nath, Yucheng Tang, Alvin Ihsani, Muhammad Asad, Fernando Pérez-García, Pritesh Mehta, Wenqi Li, Mona Flores, Holger R. Roth, Tom Vercauteren, Daguang Xu, Prerna Dogra, Sebastien Ourselin, Andrew Feng, and M. Jorge Cardoso. MONAI Label: A framework for AI-assisted
PREPRINT
interactive labeling of 3D medical images. Medical Image Analysis, 95:103207, 2024. doi: 10.1016/j.media.2024.103207.
[23] Karen López-Linares, Nerea Aranjuelo, Luis Kabongo, Gregory Maclair, Nerea Lete, Mario Ceresa, Ainhoa García-Familiar, Iván Macía, and Miguel A. González Ballester. Fully automatic detection and segmentation of abdominal aortic thrombus in post-operative CTA images using deep convolutional neural networks. Medical Image Analysis, 46:202–214, 2018. doi: 10.1016/j.media.2018.03.010.
[24] Fabien Lareyre, Cédric Adam, Marion Carrier, Carine Dommerc, Claude Mialhe, and Juliette Raffort. A fully automated pipeline for mining abdominal aortic aneurysm using image segmentation. Scientific Reports, 9:13750, 2019. doi: 10.1038/s41598-019-50251-8.
[25] Caroline Caradu, Benedetta Spampinato, Ana Maria Vrancianu, Xavier Bérard, and Eric Ducasse. Fully automatic volume segmentation of infrarenal abdominal aortic aneurysm computed tomography images with deep learning approaches versus physician controlled manual segmentation. Journal of Vascular Surgery, 74(1):246–256.e6, 2021. doi: 10.1016/j.jvs.2020.11.036.
[26] Lucie Derycke, Asmaa Doudouh, Florian Cotte, Abdelmalek Habi, Jean-Noël Albertini, and Antoine Millon. Validation of a deep learning U-Net algorithm for multistructure segmentation of infrarenal abdominal aortic aneurysms including lumen, thrombus, and calcifications. EJVES Vascular Forum, 65:1–10, 2026. doi: 10.1016/j.ejvsvf.2025.11.001. Available online 17 November 2025.
[27] Yuan Jin, Antonio Pepe, Gian Marco Melito, Yuxuan Chen, Gege Ma, Yunsu Byeon, et al. Automatic segmentation and modeling of the aortic vessel tree: Overview of the SEG.A 2023 aorta segmentation challenge. Medical Image Analysis, 115:104324, 2027. doi: 10.1016/j.media.2026.104324. Available online 17 September 2026. Preprint: arXiv:2510.24009.
[28] Mark F. Fillinger, Roy K. Greenberg, James F. McKinsey, and Elliot L. Chaikof. Reporting standards for thoracic endovascular aortic repair (TEVAR). Journal of Vascular Surgery, 52(4):1022–1033.e5, 2010. doi: 10.1016/j.jvs.2010.07.008.
[29] Joseph V. Lombardi, G. Chad Hughes, Jehangir J. Appoo, Joseph E. Bavaria, Adam W. Beck, Richard P. Cambria, Kristofer Charlton-Ouw, Mohammad H. Eslami, Karen M. Kim, Bradley G. Leshnower, Thomas Maldonado, T. Brett Reece, and Grace J. Wang. Society for vascular surgery (SVS) and society of thoracic surgeons (STS) reporting standards for type B aortic dissections. Journal of Vascular Surgery, 71(3):723–747, 2020. doi: 10.1016/j.jvs.2019.11.013.
[30] Chunyuan Li, Cliff Wong, Sheng Zhang, Naoto Usuyama, Haotian Liu, Jianwei Yang, Tristan Naumann, Hoifung Poon, and Jianfeng Gao. LLaVA-Med: Training a large language-and-vision assistant for biomedicine in one day. In Advances in Neural Information Processing Systems (Datasets and Benchmarks Track), volume 36, pages 28541–28564, 2023. doi: 10.52202/075280-1240. arXiv:2306.00890.
[31] Tao Tu, Shekoofeh Azizi, Danny Driess, Mike Schaekermann, Mohamed Amin, Pi-Chuan Chang, et al. Towards generalist biomedical AI. NEJM AI, 1(3):AIOa2300138, 2024. doi: 10.1056/AIOa2300138.
[32] Binxu Li, Tiankai Yan, Yuanting Pan, Jie Luo, Ruiyang Ji, Jiayuan Ding, Zhe Xu, Shilong Liu, Haoyu Dong, Zihao Lin, and Yixin Wang. MMedAgent: Learning to use medical tools with multi-modal agent. In Findings of the Association for Computational Linguistics: EMNLP 2024, pages 8745–8760, 2024. doi: 10.18653/v1/2024.findings-emnlp.510. arXiv:2407.02483.
[33] Adibvafa Fallahpour, Jun Ma, Alif Munim, Hongwei Lyu, and Bo Wang. MedRAX: Medical reasoning agent for chest X-ray. In Proceedings of the 42nd International Conference on Machine Learning (ICML), volume 267 of Proceedings of Machine Learning Research, pages 15661–15676. PMLR, 2025. URL https://proceedings.mlr.press/v267/fallahpour25a.html. arXiv:2502.02673.
[34] Andrew Hoopes, Neel Dey, Victor Ion Butoi, John V. Guttag, and Adrian V. Dalca. VoxelPrompt: A vision agent for end-to-end medical image analysis, 2024. Version 1 (2024) titled “VoxelPrompt: A Vision-Language Agent for Grounded Medical Image Analysis”; version 2 October 2025.
[35] Fabrizio Gilardi, Meysam Alizadeh, and Maël Kubli. ChatGPT outperforms crowd workers for text-annotation tasks. Proceedings of the National Academy of Sciences, 120(30):e2305016120, 2023. doi: 10.1073/pnas.2305016120.
[36] Lianmin Zheng, Wei-Lin Chiang, Ying Sheng, Siyuan Zhuang, Zhanghao Wu, Yonghao Zhuang, Zi Lin, Zhuohan Li, Dacheng Li, Eric P. Xing, Hao Zhang, Joseph E. Gonzalez, and Ion Stoica. Judging LLM-as-a-judge with MT-Bench and Chatbot Arena. In Advances in Neural Information Processing Systems (Datasets and Benchmarks Track), volume 36, pages 46595–46623, 2023. doi: 10.52202/075280-2020. arXiv:2306.05685.
PREPRINT
[37] Anglin Liu, Xu R. Cao, Yifan Shen, Yi Lu, Xiang Li, Qianqian Chen, and Jintai Chen. MedSAM3: Delving into segment anything with medical concepts. arXiv:2511.19046, 2025.
[38] Shengyuan Liu, Liuxin Bao, Qi Yang, Wanting Geng, et al. MedSAM-Agent: Empowering interactive medical image segmentation with multi-turn agentic reinforcement learning. arXiv:2602.03320, 2026.
[39] Jiaxi Sheng, Leyi Yu, Haoyue Li, Yifan Gao, and Xin Gao. Beyond pixel agreement: Large language models as clinical guardrails for reliable medical image segmentation. In 2025 IEEE 7th International Conference on Artificial Intelligence, Computer Science, and Information Processing (AICSIP), pages 1–6, 2025. doi: 10.1109/AICSIP65423.2025.11427241. arXiv:2506.01841.
[40] Timo Kohlberger, Vivek Singh, Chris Alvino, Claus Bahlmann, and Leo Grady. Evaluating segmentation error without ground truth. In Medical Image Computing and Computer-Assisted Intervention – MICCAI 2012, Part I, Lecture Notes in Computer Science, pages 528–536, Berlin, Heidelberg, 2012. Springer. doi: 10.1007/978-3-642-33415-3_65.
[41] Vanya V. Valindria, Ioannis Lavdas, Wenjia Bai, Konstantinos Kamnitsas, Eric O. Aboagye, Andrea G. Rockall, Daniel Rueckert, and Ben Glocker. Reverse classification accuracy: Predicting segmentation performance in the absence of ground truth. IEEE Transactions on Medical Imaging, 36(8):1597–1606, 2017. doi: 10.1109/TMI.2017.2665165.
[42] Robert Robinson, Vanya V. Valindria, Wenjia Bai, Ozan Oktay, Bernhard Kainz, Hideaki Suzuki, Mihir M. Sanghvi, Nay Aung, José Miguel Paiva, Filip Zemrak, Kenneth Fung, Elena Lukaschuk, Aaron M. Lee, Valentina Carapella, Young Jin Kim, Stefan K. Piechnik, Stefan Neubauer, Steffen E. Petersen, Chris Page, Paul M. Matthews, Daniel Rueckert, and Ben Glocker. Automated quality control in image segmentation: application to the UK Biobank cardiovascular magnetic resonance imaging study. Journal of Cardiovascular Magnetic Resonance, 21(1):18, 2019. doi: 10.1186/s12968-019-0523-x.
[43] Lee R. Dice. Measures of the amount of ecologic association between species. Ecology, 26(3):297–302, 1945. doi: 10.2307/1932409.
[44] Stanislav Nikolov, Sam Blackwell, Alexei Zverovitch, Ruheena Mendes, Michelle Livne, Jeffrey De Fauw, et al. Clinically applicable segmentation of head and neck anatomy for radiotherapy: Deep learning algorithm development and validation study. Journal of Medical Internet Research, 23(7):e26151, 2021. doi: 10.2196/26151.
[45] Lena Maier-Hein, Annika Reinke, Patrick Godau, Minu D. Tizabi, Florian Buettner, Evangelia Christodoulou, et al. Metrics reloaded: recommendations for image analysis validation. Nature Methods, 21(2):195–212, 2024. doi: 10.1038/s41592-023-02151-z.
[46] James A. Hanley and Barbara J. McNeil. The meaning and use of the area under a receiver operating characteristic (ROC) curve. Radiology, 143(1):29–36, 1982. doi: 10.1148/radiology.143.1.7063747.
[47] Jacob Cohen. A coefficient of agreement for nominal scales. Educational and Psychological Measurement, 20(1): 37–46, 1960. doi: 10.1177/001316446002000104.
[48] Frank Wilcoxon. Individual comparisons by ranking methods. Biometrics Bulletin, 1(6):80–83, 1945. doi: 10.2307/3001968.
[49] Bradley Efron. Bootstrap methods: Another look at the jackknife. The Annals of Statistics, 7(1):1–26, 1979. doi: 10.1214/aos/1176344552.
[50] Sture Holm. A simple sequentially rejective multiple test procedure. Scandinavian Journal of Statistics, 6(2): 65–70, 1979. URL https://www.jstor.org/stable/4615733.
PREPRINT
A Datasets, sampling and scored region
Datasets. We used six public datasets with 939 volumes (Table 1): 100 whole-body angiograms of type B dissections from the AortaSeg24 challenge dataset with 23 expert vessel ids [1], of which we score the 14 abdominal ids because our thoracic zones are unverified; 520 aneurysm and endograft crops of voxels (about 80 mm across) from the Siriapisith pre- and post-operative AAA CTA set (Siriapisith AAA/EVAR), labeled with the outer envelope [3]; 98 scans of MosMedData abdominal aorta CTA (MosMedData AAA) with lumen and calcium [4, 12]; 55 scans of the Aortic Vessel Tree (AVT) collection from three sources with a binary lumen tree [2]; 17 models of the Vascular Model Repository (VMR) with a lofted lumen per named vessel [6]; and 149 cardiac phases of 20 patients from the 4D-CTA image and geometry dataset of abdominal aortic aneurysms (Jamshidian 4D-CTA) with thrombus and sac meshes [5]. Development also used one in-house scan, AVT Rider R6 with a four-class tissue reference drawn by an expert reviewer. It was among the free-form cases and the pilot of Taurus-hybrid, but because it is a single case we leave it out of all results.
The starting vessels came from our nnU-Net [7] vessel model with a branch refiner on AortaSeg24 (out-of-fold, since it was trained there), MosMedData AAA, AVT and VMR, and from TotalSegmentator 2.13 [8] on Siriapisith AAA/EVAR and the Jamshidian 4D-CTA phases. The 27 vessel labels of the label contract are the ten aortic zones 0–9, the brachiocephalic trunk, left common carotid, left subclavian, celiac trunk, superior and inferior mesenteric arteries, the right and left renal, accessory renal, common iliac, internal iliac and external iliac arteries, and one label for any other aortic branch.
Sampling. Samples were drawn by a salted SHA-1 hash of the case key within strata (for example MosMedData AAA by pathology, Jamshidian by patient) and frozen before any run. Taurus-base labels exist for 438 cases: all AortaSeg24 and MosMedData AAA cases, 160 Siriapisith AAA/EVAR crops, 24 AVT cases, all VMR models and 39 Jamshidian phases (two per patient). Taurus-base (auto) ran on all 939 volumes; it produced no output on 30 (28 Siriapisith AAA/EVAR crops, one Jamshidian 4D-CTA phase, one AVT case) because the proposal found no aorta, and only the phase was in a review sample. Identity accuracy (AortaSeg24) is the share of voxels labeled as vessel in both maps that carry the same id.
Scored region. The study plan described the scored region as the human label restricted to the vessels and zones of our label contract and dilated by 5 mm. The scorer, written the same day and before the first run, implements it per dataset instead: overlap on AortaSeg24 and Siriapisith AAA/EVAR is scored on the whole volume (the AortaSeg24 confusion matrix within 3 mm of either label), on MosMedData AAA within the axial extent of the human label and 15 mm of it, on VMR within the axial extent of the human label and 10 mm of either label, on AVT within the axial extent of our trunk and iliac labels and 10 mm of either label, and on Jamshidian 4D-CTA within the axial extent of the reference sac. No scoring rule changed after the runs began except the VMR id merge: VMR labels the whole aorta with one id, so we merged our trunk zones before scoring, a change made after the first runs and applied to every approach.
B Paired statistics
This appendix gives the paired comparisons behind the main-text results: all main-experiment pairs in Table 5, the held-out medians in Table 6 and all held-out pairs in Figure 8.
PREPRINT
Table 4: Paired comparisons behind the main-text Results: median difference of the first approach minus the second, bootstrap 95 % CI where computed, cases better and worse by more than 0.005 for the first approach, and Wilcoxon p. The two base-review rows of the main experiment are Holm-adjusted, all others unadjusted. Taurus approaches are named Taurus-base, Taurus-tuned and Taurus-hybrid, with (auto) marking the automated pass alone. For MSD, HD95 and terracing, lower is better.
| Comparison | Cases | Metric | Median Δ | 95 % CI | Better/ worse | p |
|---|---|---|---|---|---|---|
| Main experiment | ||||||
| base — base (auto) | Siriapisith AAA/EVAR, 160 | outer Dice | +0.013 | 0.000 to 0.025 | 92/15 | 1.5 × 10⁻¹⁴ |
| base — base (auto) | AVT, 24 | tree Dice | +0.022 | 0.001 to 0.049 | 21/1 | 0.0024 |
| hybrid — Free-form Opus | free-form, 30 | primary metric | +0.027 | — | 21/6 | 0.001 |
| NSD at 1 mm | +0.095 | — | 23/6 | 0.0003 | ||
| MSD (mm) | −0.53 | — | 24/5 | 0.001 | ||
| terracing (mm) | −0.002 | — | 13/12 | 0.65 | ||
| Held-out cases | ||||||
| tuned (auto) — base (auto) | held-out, 38 | primary metric | +0.258 | 0.076 to 0.389 | 32/2 | 8.8 × 10⁻⁷ |
| tuned — tuned (auto) | held-out, 38 | primary metric | +0.000 | 0.000 to 0.001 | 11/1 | 0.019 |
| base — base (auto) | held-out, 38 | primary metric | +0.000 | 0.000 to 0.002 | 11/1 | 0.0032 |
| hybrid (auto) — tuned (auto) | held-out, 38 | primary metric | +0.005 | 0.003 to 0.009 | 19/2 | 3.0 × 10⁻⁵ |
| terracing (mm) | −0.168 | — | 27/4 | 2.2 × 10⁻⁷ | ||
| hybrid — hybrid (auto) | held-out, 38 | primary metric | +0.025 | 0.004 to 0.108 | 24/5 | 0.0001 |
| MSD (mm) | −0.33 | — | 24/4 | 0.0004 | ||
| HD95 (mm) | −0.09 | — | 19/7 | 0.004 | ||
| hybrid — tuned | held-out, 38 | primary metric | +0.021 | 0.006 to 0.041 | 26/5 | 1.9 × 10⁻⁵ |
| NSD at 1 mm | +0.017 | — | 25/9 | 0.0015 | ||
| terracing (mm) | −0.155 | — | 33/2 | 6.0 × 10⁻⁹ | ||
| HD95 (mm) | −0.348 | — | 21/14 | 0.096 | ||
| hybrid — first hybrid build | held-out, 38 | primary metric | +0.009 | 0.001 to 0.017 | 21/6 | 0.0037 |
| hybrid — Free-form Sonnet | held-out, 38 | primary metric | +0.073 | 0.039 to 0.167 | 28/10 | 0.0009 |
| hybrid — Free-form Opus | held-out, 38 | primary metric | +0.006 | −0.022 to 0.045 | 20/18 | 0.36 |
| NSD at 1 mm | +0.046 | — | 23/14 | 0.045 | ||
| MSD (mm) | −0.11 | — | 19/17 | 0.36 | ||
| terracing (mm) | −0.002 | — | 17/16 | 0.85 | ||
| tuned — Free-form Opus | held-out, 38 | primary metric | −0.023 | −0.049 to −0.007 | 11/26 | 0.067 |
PREPRINT
Table 5: Paired comparisons of the primary metric in the main experiment: median difference, bootstrap 95 % interval, Wilcoxon p, Holm-adjusted p and the number of cases better/worse for the first approach. Source: results/tables/T2_pairs.md.
| Comparison | Dataset | n | median Δ | 95 % CI | p | p (Holm) | better/worse |
|---|---|---|---|---|---|---|---|
| Taurus-base – Taurus-base (auto) | AortaSeg24 | 100 | +0.000 | [+0.000, +0.000] | 4.83e-05 | 0.00246 | 45/15 |
| Taurus-base – Taurus-base (auto) | Siriapisith AAA/EVAR | 160 | +0.013 | [+0.000, +0.025] | 2.62e-16 | 1.49e-14 | 92/15 |
| Taurus-base – Taurus-base (auto) | MosMedData AAA | 98 | +0.000 | [+0.000, +0.000] | 0.817 | 1 | 18/16 |
| Taurus-base – Taurus-base (auto) | AVT | 24 | +0.022 | [+0.001, +0.049] | 4.61e-05 | 0.0024 | 21/1 |
| Taurus-base – Taurus-base (auto) | VMR | 17 | +0.000 | [+0.000, +0.002] | 0.0754 | 1 | 8/3 |
| Taurus-base – Taurus-base (auto) | Jamshidian 4D-CTA | 39 | +0.000 | [+0.000, +0.000] | 0.291 | 1 | 10/12 |
| Crossover – Taurus-base (auto) | AortaSeg24 | 10 | +0.000 | [+0.000, +0.000] | 1 | 1 | 0/1 |
| Crossover – Taurus-base (auto) | Siriapisith AAA/EVAR | 10 | +0.216 | [+0.099, +0.487] | 0.00195 | 0.0977 | 10/0 |
| Crossover – Taurus-base (auto) | MosMedData AAA | 10 | +0.000 | [+0.000, +0.000] | 0.5 | 1 | 2/0 |
| Crossover – Taurus-base (auto) | AVT | 8 | +0.000 | [+0.000, +0.000] | — | — | 0/0 |
| Crossover – Taurus-base (auto) | VMR | 6 | -0.000 | [-0.025, +0.000] | 0.25 | 1 | 0/3 |
| Crossover – Taurus-base (auto) | Jamshidian 4D-CTA | 10 | +0.000 | [-0.002, +0.019] | 0.875 | 1 | 2/2 |
| Repeat – Taurus-base (auto) | AortaSeg24 | 5 | +0.005 | [+0.000, +0.021] | 0.25 | 1 | 3/0 |
| Repeat – Taurus-base (auto) | Siriapisith AAA/EVAR | 5 | +0.021 | [+0.000, +0.220] | 0.125 | 1 | 4/0 |
| Repeat – Taurus-base (auto) | MosMedData AAA | 5 | +0.000 | [+0.000, +0.044] | 1 | 1 | 1/0 |
| Repeat – Taurus-base (auto) | AVT | 3 | +0.039 | [+0.000, +0.807] | 0.25 | 1 | 3/0 |
| Repeat – Taurus-base (auto) | VMR | 3 | +0.002 | [+0.000, +0.010] | 0.5 | 1 | 2/0 |
| Repeat – Taurus-base (auto) | Jamshidian 4D-CTA | 3 | +0.229 | [+0.000, +0.402] | 0.5 | 1 | 2/0 |
| Crossover – Taurus-base | AortaSeg24 | 10 | -0.000 | [-0.004, +0.000] | 0.0625 | 1 | 0/5 |
| Crossover – Taurus-base | Siriapisith AAA/EVAR | 10 | +0.110 | [+0.054, +0.243] | 0.00195 | 0.0977 | 10/0 |
| Crossover – Taurus-base | MosMedData AAA | 10 | +0.000 | [-0.000, +0.000] | 1 | 1 | 2/3 |
| Crossover – Taurus-base | AVT | 8 | -0.019 | [-0.045, -0.001] | 0.00781 | 0.375 | 0/8 |
| Crossover – Taurus-base | VMR | 6 | -0.000 | [-0.032, +0.003] | 0.625 | 1 | 1/3 |
| Crossover – Taurus-base | Jamshidian 4D-CTA | 10 | -0.010 | [-0.500, +0.043] | 0.312 | 1 | 3/5 |
| Repeat – Taurus-base | AortaSeg24 | 5 | +0.001 | [-0.010, +0.005] | 0.875 | 1 | 3/1 |
| Repeat – Taurus-base | Siriapisith AAA/EVAR | 5 | +0.000 | [-0.109, +0.041] | 1 | 1 | 2/2 |
| Repeat – Taurus-base | MosMedData AAA | 5 | +0.000 | [+0.000, +0.044] | 1 | 1 | 1/0 |
| Repeat – Taurus-base | AVT | 3 | +0.002 | [-0.000, +0.005] | 0.5 | 1 | 2/1 |
| Repeat – Taurus-base | VMR | 3 | +0.000 | [-0.000, +0.000] | 1 | 1 | 1/1 |
| Repeat – Taurus-base | Jamshidian 4D-CTA | 3 | -0.030 | [-0.042, +0.000] | 0.5 | 1 | 0/2 |
| Taurus-base – Free-form Opus | AortaSeg24 | 5 | +0.080 | [+0.028, +0.184] | 0.0625 | 1 | 5/0 |
| Taurus-base – Free-form Opus | Siriapisith AAA/EVAR | 6 | -0.157 | [-0.462, -0.125] | 0.0312 | 1 | 0/6 |
| Taurus-base – Free-form Opus | MosMedData AAA | 5 | -0.081 | [-0.807, +0.039] | 0.188 | 1 | 1/4 |
| Taurus-base – Free-form Opus | AVT | 5 | -0.063 | [-0.100, -0.012] | 0.0625 | 1 | 0/5 |
| Taurus-base – Free-form Opus | VMR | 4 | +0.003 | [-0.923, +0.021] | 0.875 | 1 | 3/1 |
| Taurus-base – Free-form Opus | Jamshidian 4D-CTA | 5 | -0.223 | [-0.704, +0.021] | 0.312 | 1 | 2/3 |
| Taurus-base – Free-form Sonnet | AortaSeg24 | 5 | +0.381 | [+0.093, +0.667] | 0.0625 | 1 | 5/0 |
| Taurus-base – Free-form Sonnet | Siriapisith AAA/EVAR | 6 | -0.132 | [-0.395, -0.055] | 0.0312 | 1 | 0/6 |
| Taurus-base – Free-form Sonnet | MosMedData AAA | 5 | +0.010 | [-0.465, +0.158] | 0.812 | 1 | 3/2 |
| Taurus-base – Free-form Sonnet | AVT | 5 | +0.172 | [-0.062, +0.275] | 0.125 | 1 | 4/1 |
| Taurus-base – Free-form Sonnet | VMR | 4 | +0.355 | [-0.915, +0.447] | 0.875 | 1 | 3/1 |
| Taurus-base – Free-form Sonnet | Jamshidian 4D-CTA | 5 | +0.004 | [-0.568, +0.260] | 1 | 1 | 3/2 |
| Free-form Opus – Free-form Sonnet | AortaSeg24 | 5 | +0.300 | [+0.065, +0.594] | 0.0625 | 1 | 5/0 |
| Free-form Opus – Free-form Sonnet | Siriapisith AAA/EVAR | 6 | +0.041 | [-0.017, +0.137] | 0.156 | 1 | 5/1 |
| Free-form Opus – Free-form Sonnet | MosMedData AAA | 5 | +0.118 | [+0.019, +0.343] | 0.0625 | 1 | 5/0 |
| Free-form Opus – Free-form Sonnet | AVT | 5 | +0.232 | [+0.023, +0.338] | 0.0625 | 1 | 5/0 |
| Free-form Opus – Free-form Sonnet | VMR | 4 | +0.344 | [+0.009, +0.443] | 0.125 | 1 | 4/0 |
| Free-form Opus – Free-form Sonnet | Jamshidian 4D-CTA | 5 | +0.239 | [+0.000, +0.473] | 0.125 | 1 | 4/0 |
| Taurus-base – B11 alone | AortaSeg24 | 30 | -0.135 | [-0.140, -0.122] | 2.56e-06 | 0.000138 | 0/29 |
| Taurus-base – B11 alone | MosMedData AAA | 39 | +0.191 | [-0.003, +0.260] | 0.0349 | 1 | 22/16 |
| Taurus-base – B11 alone | AVT | 24 | +0.011 | [+0.002, +0.019] | 0.034 | 1 | 18/6 |
| Taurus-base – B11 alone | VMR | 17 | +0.014 | [+0.000, +0.023] | 0.0267 | 1 | 13/4 |
| Taurus-base – TotalSegmentator | Siriapisith AAA/EVAR | 60 | +0.598 | [+0.544, +0.714] | 1.8e-11 | 1.01e-09 | 59/1 |
| Taurus-base (auto) – B11 alone | AortaSeg24 | 30 | -0.140 | [-0.147, -0.124] | 2.56e-06 | 0.000138 | 0/29 |
| Taurus-base (auto) – B11 alone | MosMedData AAA | 39 | +0.000 | [-0.011, +0.243] | 0.162 | 1 | 19/19 |
| Taurus-base (auto) – B11 alone | AVT | 24 | -0.018 | [-0.047, +0.010] | 0.0604 | 1 | 10/14 |
| Taurus-base (auto) – B11 alone | VMR | 17 | +0.009 | [-0.002, +0.022] | 0.0984 | 1 | 12/5 |
| Taurus-base (auto) – TotalSegmentator | Siriapisith AAA/EVAR | 60 | +0.502 | [+0.439, +0.562] | 1.99e-11 | 1.1e-09 | 58/2 |
PREPRINT
Table 6: Full held-out results on the 38 evaluation cases (26 hard, 12 typical), the long form of Table 3: median primary metric per dataset and over all, hard and typical cases (each dataset in its own metric, so the pooled columns are descriptive), and LLM cost, minutes from scan to label (vessel proposal and automated pass, plus the review for the reviewed approaches) and turns per case; ± half the interquartile range beneath each median. Bold marks the highest median of the column, and asterisks mark medians that rest on two cases where an approach left an almost empty label and on the calcium scoring convention. Figure 8 draws the paired differences, and Table 4 in the main text gives those quoted there. Taurus-base (auto) and Taurus-base form the paired control, re-run and re-reviewed on the same cases; Taurus-tuned starts from the frozen Taurus-tuned (auto) labels and Taurus-hybrid from its own automated pass, regenerated from the same proposals; Free-form Opus ran on all 38 cases. Taurus-hybrid was designed after the results of Taurus-tuned and of its own first build were seen, so its comparison is not blind. Source: results/tables/T8_A5.md, T11_v31_eval.md and T11_v31_eval_pairs.md.
| Approach | Primary metric per dataset | All held-out cases / stratum | Cost per case | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| AortaSeg24 (4) | Siriapisith AAA/EVAR (12) | MosMedData AAA (8) | AVT (4) | VMR (4) | Jamshidian 4D-CTA (6) | all (38) | hard (26) | typical (12) | $ | min | turns | |
| Taurus-base (auto) | 0.572 ±0.072 | 0.496 ±0.096 | 0.021 ±0.071 | 0.027 ±0.108 | 0.490 ±0.043 | 0.002 ±0.005 | 0.321 ±0.259 | 0.109 ±0.225 | 0.573 ±0.151 | - | 0.7 ±1.1 | - |
| Taurus-base | 0.579 ±0.076 | 0.496 ±0.096 | 0.024 ±0.076 | 0.432 ±0.405 | 0.492 ±0.037 | 0.004 ±0.004 | 0.410 ±0.260 | 0.144 ±0.222 | 0.640 ±0.146 | 0.20 ±0.44 | 1.5 ±4.2 | 8 ±8 |
| Taurus-tuned (auto) | 0.732 ±0.031 | 0.783 ±0.130 | 0.462 ±0.089 | 0.437 ±0.406 | 0.464 ±0.048 | 0.534 ±0.186 | 0.620 ±0.159 | 0.598 ±0.145 | 0.716 ±0.195 | - | 1.0 ±1.1 | - |
| Taurus-tuned | 0.732 ±0.032 | 0.871 ±0.037 | 0.462 ±0.104 | 0.437 ±0.406 | 0.466 ±0.064 | 0.572 ±0.222 | 0.704 ±0.202 | 0.698 ±0.199 | 0.716 ±0.196 | 0.75 ±0.23 | 6.4 ±4.7 | 16 ±5 |
| Taurus-hybrid (auto) | 0.734 ±0.031 | 0.791 ±0.135 | 0.468 ±0.105 | 0.454 ±0.428 | 0.468 ±0.047 | 0.587 ±0.180 | 0.647 ±0.154 | 0.619 ±0.137 | 0.725 ±0.202 | - | 1.1 ±1.3 | - |
| Taurus-hybrid | 0.733 ±0.026 | 0.897 ±0.022 | 0.853 ±0.104 | 0.442 ±0.455 | 0.483 ±0.073 | 0.732 ±0.043 | 0.805 ±0.114 | 0.818 ±0.110 | 0.762 ±0.115 | 1.22 ±0.45 | 6.4 ±5.0 | 23 ±10 |
| Free-form | 0.307 ±0.071 | 0.802 ±0.045 | 0.773* ±0.177 | 0.823* ±0.099 | 0.226 ±0.126 | 0.430 ±0.262 | 0.677 ±0.195 | 0.714 ±0.150 | 0.441 ±0.372 | 0.18 ±0.04 | 1.3 ±0.8 | 13 ±4 |
| Sonnet | 0.629 ±0.033 | 0.892 ±0.021 | 0.837 ±0.203 | 0.466* ±0.432 | 0.446 ±0.035 | 0.715 ±0.052 | 0.802 ±0.196 | 0.829 ±0.165 | 0.665 ±0.208 | 2.71 ±1.51 | 16.1 ±8.2 | 70 ±25 |
PREPRINT

Figure 8: All paired comparisons of the primary metric on the held-out cases, per stratum (hard, typical, all): median difference with bootstrap 95 % interval, cases better/worse and unadjusted Wilcoxon p. Source: results/tables/T8_A5_pairs.csv and T11_v31_eval_pairs.md.
PREPRINT
C Surface metrics
Terracing is the mean deviation of each axial slice's tracked 2D component from the mean of its two neighbors, in equivalent radius and centroid; roughness is the mean distance of the voxel surface from a Gaussian-smoothed copy ( mm); the signed edge offset is the mean in-plane distance from an approach's boundary to the reference's edge on slices where both exist (clipped at mm, positive outside); and the lumen edge level is the mean of the median attenuation just inside and just outside the boundary on a CT smoothed in-plane at 0.7 mm, divided by blood attenuation (the median of the reference structure eroded twice). Distances are undefined for a class that one side leaves empty, where NSD is 0, and the surface scorer reproduces the primary scorer's Dice and volumes on all 2,111 class rows it was checked on.
PREPRINT
Table 7: Boundary and surface quality on the 38 held-out cases against the human reference. Top and middle: median [IQR] per approach of Dice, NSD at 1 and 2 mm, mean surface distance (MSD), HD95, signed edge offset, lumen edge level, terracing and roughness, with the reference's own edge level, terracing and roughness (n in brackets where a metric is undefined on some cases). Bottom: per-dataset medians of NSD at 1 mm and MSD. Per case each value is the mean over the dataset's primary-metric classes; pooled medians are descriptive. Paired tests: Table 4. Source: results/tables/T9_surface.md (block A) and T11_v31_eval1.md.
| Approach (cases) | Dice | NSD 1 mm | NSD 2 mm | MSD (mm) | HD95 (mm) |
|---|---|---|---|---|---|
| Taurus-base (auto) (38) | 0.321[0.018, 0.536] | 0.118[0.014, 0.366] | 0.233[0.040, 0.490] | 12.73[6.79, 18.68] (37) | 29.9[22.0, 54.5] (37) |
| Taurus-base (38) | 0.410[0.021, 0.542] | 0.153[0.026, 0.432] | 0.290[0.044, 0.575] | 11.43[5.84, 18.51] (37) | 29.2[19.8, 44.5] (37) |
| Taurus-tuned (auto) (38) | 0.620[0.451, 0.769] | 0.393[0.254, 0.560] | 0.588[0.458, 0.747] | 2.59[1.67, 6.51] (37) | 14.4[6.3, 23.5] (37) |
| Taurus-tuned (38) | 0.704[0.450, 0.854] | 0.431[0.276, 0.566] | 0.662[0.477, 0.768] | 2.00[1.43, 5.61] (37) | 9.8[5.5, 20.2] (37) |
| Taurus-hybrid (auto) (38) | 0.647[0.466, 0.773] | 0.402[0.255, 0.577] | 0.582[0.457, 0.756] | 2.42[1.64, 6.26] (37) | 14.1[7.1, 24.1] (37) |
| Taurus-hybrid (38) | 0.805[0.670, 0.899] | 0.494[0.371, 0.702] | 0.761[0.629, 0.860] | 1.58[1.07, 3.20] | 8.0[5.0, 14.0] |
| Free-form | 0.677 | 0.301 | 0.489 | 3.19 | 14.8 |
| Sonnet (38) | [0.417, 0.808] | [0.175, 0.461] | [0.351, 0.679] | [1.45, 7.76] (36) | [6.9, 28.1] (36) |
| Free-form | 0.802 | 0.405 | 0.638 | 2.04 | 6.4 |
| Opus (38) | [0.497, 0.889] | [0.260, 0.600] | [0.504, 0.824] | [0.78, 2.86] (36) | [3.4, 17.4] (36) |
| Approach (cases) | Edge offset (mm) | Edge level (× blood) | Terracing (mm) | Roughness (mm) |
|---|---|---|---|---|
| Taurus-base (auto) (38) | +0.42[−1.72, +1.48] (37) | 0.49[0.23, 0.91] (22) | 0.61[0.41, 0.88] (33) | 0.61[0.47, 1.06] (37) |
| Taurus-base (38) | +0.80[−1.72, +1.74] (37) | 0.33[0.23, 0.51] (22) | 0.48[0.40, 0.93] (32) | 0.56[0.46, 0.88] (37) |
| Taurus-tuned (auto) (38) | +0.60[−0.20, +1.25] (37) | 0.53[0.39, 0.58] (24) | 0.71[0.50, 1.05] (36) | 0.50[0.44, 0.77] (37) |
| Taurus-tuned (38) | +0.63[−0.04, +1.23] (37) | 0.52[0.38, 0.57] (24) | 0.65[0.50, 1.07] (36) | 0.47[0.44, 0.79] (37) |
| Taurus-hybrid (auto) (38) | +0.54[−0.09, +1.14] (37) | 0.60[0.57, 0.62] (25) | 0.50[0.35, 0.73] (37) | 0.43[0.35, 0.78] (37) |
| Taurus-hybrid (38) | +0.76[+0.26, +1.46] | 0.60[0.57, 0.61] (26) | 0.38[0.23, 0.56] | 0.35[0.30, 0.55] |
| Free-form | +0.36 | 0.63 | 0.31 | 0.41 |
| Sonnet (38) | [−0.21, +1.27] (36) | [0.54, 0.68] (26) | [0.20, 0.56] (36) | [0.36, 0.55] (36) |
| Free-form | +1.32 | 0.54 | 0.33 | 0.38 |
| Opus (38) | [+0.23, +2.05] (36) | [0.51, 0.57] (25) | [0.18, 0.48] (36) | [0.29, 0.64] (36) |
| Human reference, itself (38) | 0.59[0.39, 0.74] (26) | 0.47[0.31, 0.65] | 0.40[0.32, 0.52] |
| NSD 1 mmMSD (mm) | Taurus-base (auto) | Taurus-base | Taurus-tuned (auto) | Taurus-tuned | Taurus-hybrid (auto) | Taurus-hybrid | Free-formSonnet | Free-formOpus |
|---|---|---|---|---|---|---|---|---|
| AortaSeg24 (4) | 0.58911.86 | 0.59011.94 | 0.7121.82 | 0.7131.66 | 0.7121.80 | 0.7161.70 | 0.2737.79 | 0.5903.99 |
| Siriapisith AAA/EVAR (12) | 0.1398.24 | 0.1538.24 | 0.3103.30 | 0.3771.97 | 0.2893.34 | 0.4001.59 | 0.2073.19 | 0.2981.91 |
| MosMedData AAA (8) | 0.00743.65 | 0.00743.65 | 0.4620.90 | 0.4620.90 | 0.4830.75 | 0.8490.65 | 0.6840.76 | 0.9420.38 |
| AVT (4) | 0.09718.08 | 0.28310.43 | 0.32710.50 | 0.32710.50 | 0.42031.08 | 0.38712.25 | 0.6411.59 | 0.4121.31 |
| VMR (4) | 0.4909.88 | 0.47810.04 | 0.43210.55 | 0.46010.56 | 0.44710.57 | 0.48110.16 | 0.22011.93 | 0.43010.92 |
| Jamshidian 4D-CTA (6) | 0.00714.45 | 0.02912.25 | 0.3573.13 | 0.3603.10 | 0.3412.38 | 0.4941.38 | 0.1964.82 | 0.3392.17 |
D Harness failure taxonomy
Reviewers reported harness defects in their hand-backs, and the score audits, the edit replay and the reviewers of Taurus-tuned and Taurus-hybrid added more; the first 65 fall into the groups below, and Table 8 lists the ten found with Taurus-hybrid. The largest groups concern trust in the proposal (mirrored or header-flipped orientation, a trunk on the spine or vertebrae), thresholds that fail in opposite directions on poor and bright contrast, an outer boundary that under-grows the sac or leaks into veins, bowel, psoas and the crura, branch identity and zones, and edit tools whose
PREPRINT
reach or guard rails did not fit the task. Others concern latency on whole-body volumes, protocol details (verdicts recorded without opening the latest image, issue codes rejected by the tool), and scoring.
Table 8: Issues found with Taurus-hybrid: 66–68 in the pilot on non-evaluation cases (fixed before the held-out run), 69–75 in the held-out reviews (kept out of the harness design; two generic code faults fixed during the run). Source: results/harness_issues.md.
| # | Found in | Problem | Status |
|---|---|---|---|
| 66 | pilot, Siriapisith AAA/EVAR and Jamshidian 4D-CTA | blood value contaminated by calcium on a 4D phase; end slices refused by interp-outer; card coordinates on the down-sampled grid; broad outer tools overshoot where no fat plane separates the aorta; false branches in crops | fixed (robust blood, end slices, coordinates) |
| 67 | pilot, whole-body | card coordinates relative to the working box; outer-trimming tools strip the wall ring; false arch-branch specks; working box too narrow; coverage warning on by-design lumen-only iliacs | fixed (wall ring, branch cleanup, box report) |
| 68 | pilot, chest scans | root recipes did nothing; card options computed before the regularization; branch-lumen pieces not removable; edits on the largest volume over 10 min | fixed (root tracker, options as differences, branch-remove); latency on the largest volume open |
| 69 | held-out, Siriapisith AAA/EVAR and Jamshidian 4D-CTA | missing or collapsed sac runs; growth tools cap giant sacs, key-slice polygons needed; coverage check reported a gap as complete; vertebral branches survive the cleanup; a very bright phase left the lumen empty; guard rails refused calcium hysteresis and the regularization with an endoleak | open |
| 70 | held-out, Siriapisith AAA/EVAR and Jamshidian 4D-CTA | flat-cut sac ends and truncated trunks; growth over 30 % refused without forcing; new trunk voxels without a vessel id; tracker recipe crashed on its slice range; giant sac or hematoma undecidable | open; id and crash fixed during the run |
| 71 | held-out, MosMedData AAA | collar needs more than 10 % outer removal; side names reversed on header-flipped volumes; lumen on the vertebral body; branch tools refuse clicks inside the trunk; stent graft in a case listed without one | open |
| 72 | held-out, whole-body | tracker fails when the box clips the aorta, when thresholds come from the wrong tissue and on unenhanced scans; unenhanced scan run as enhanced; arch names on far fragments | open |
| 73 | held-out, whole-body | collar on normal-caliber aortas in 4 of 4 cases; wrong vessel names; expected branches not found in 4 of 5; dense calcium missed; command killed at the memory cap | open; cap raised to 16 GB |
| 74 | held-out, VMR | branches stop early (extend_branch fixed them); sides reversed on a header-mirrored case; AI outline unreliable | open |
| 75 | held-out, whole-body | collar; superior mesenteric artery truncated or merged into the trunk; limb names; interleaved lumen and thrombus in a false lumen; memory kills on the largest volume; edit applied but not recorded when its render failed | open; record fixed during the run |
E Cost accounting
All LLM runs were Claude Code sessions under one account, sharing runtime, tools and prompt cache. For every model response, the transcript records the model id, the timestamps and four token counts: fresh input, cache writes, cache reads and output. We price each count at Anthropic's listed token prices for usage as of October 2026 (Table 9), sum the four products for each response and sum the responses of a run to obtain its cost. Claude Code writes one-hour cache entries, which are priced at twice the input rate. A review's cost is its transcript segment plus a share of the session start-up, and it is understated by 3–6 % because some output counts are missing, while free-form cost is the client's own report of the same quantity. Under a subscription these are cost equivalents, not invoices, and the automated pass, which runs on the CPU, is not priced. Review time is active transcript time and free-form time the run's wall time. We timed the preprocessing that precedes a review separately, on the 38 held-out cases, one case at a time on the otherwise idle workstation (AMD Ryzen 9 3900X, RTX 4090): the vessel proposal on the GPU, then each version's automated pass on the CPU. For Taurus-hybrid the two took a median of 25 s per case on Jamshidian 4D-CTA, 26 s on Siriapisith AAA/EVAR, 76 s on MosMedData AAA, 195 s on AortaSeg24, 238 s on VMR and 310 s on AVT, of which the proposal took 9–17 s except on the larger VMR (58 s) and AVT (143 s) scans. The minutes in Tables 3 and 6 add these times to the review time, which makes a median of 6.4 min per case for Taurus-hybrid against 16.1 min for Free-form Opus. A median Opus review of an AortaSeg24 case read 1.58 M cached tokens and wrote 1.4 k output tokens.
PREPRINT
Table 9: Anthropic's listed token prices for usage (October 2026), in US dollars per million tokens.
| Model | Input | Output | Cache read | Cache write (5 min) | Cache write (1 h) |
|---|---|---|---|---|---|
| Claude Opus 5.5 (claude-opus-5-5) | 4.00 | 20.00 | 0.20 | 5.00 | 8.00 |
| Claude Sonnet 5.5 (claude-sonnet-5-5) | 2.00 | 10.00 | 0.20 | 2.50 | 4.00 |
| Claude Sonnet 5 (claude-sonnet-5) | 2.00 | 10.00 | 0.20 | 2.50 | 4.00 |
F Downstream training on recovered labels
To test whether recovered labels can train segmentation models, we trained models on five label sources and evaluated them on held-out human labels of the same dataset. The sources are the human labels (L0), Taurus-base (auto) (L1), Taurus-base (L2), Taurus-base (auto) restricted to the cases that the reviewer did not mark issue (L2-noedit, which separates the value of the verdict from that of the edits), and Reference-seeded (not blind) (L3). MosMedData AAA uses 78 training cases (L2-noedit 40) and 20 locked patients, Siriapisith AAA/EVAR uses 130 reviewed contrast-enhanced crops (L2-noedit 56) and the 40 sealed test crops, and AortaSeg24 uses 89 training cases (L2-noedit 27) and 10 locked cases. The tissue models use one recipe in the dataset's own classes, 250 epochs and three seeds, and 13 of the 78 MosMedData AAA L1 and L2 training labels are orientation failures. The study plan expected L2 ≥ L1, L2 within 0.03 of L0, L2-noedit between L1 and L2, and L3 ≥ L2. Table 10 gives the results for MosMedData AAA and Siriapisith AAA/EVAR, and the AortaSeg24 runs are still in progress. Paired tests compare per-case means over the seeds and are unadjusted.
Models trained on Taurus-base labels fell well short of models trained on human labels. On Siriapisith AAA/EVAR, the outer Dice of the L2 models was 0.699 against 0.975 for L0 (paired median −0.254; 0 better, 40 worse; ), and on MosMedData AAA their primary metric was 0.522 against 0.804 (−0.137; 6/14; ). Review of the training labels helped on Siriapisith AAA/EVAR, where L2 exceeded L1 by a paired median of 0.075 (33/3, ), but not on MosMedData AAA (−0.000, 4/6, ), whose training labels include orientation failures that no edit verb could repair. Dropping the cases marked issue raised the mean on MosMedData AAA from 0.522 to 0.679, although the paired median moved by only +0.002 (10/5, ), while on Siriapisith AAA/EVAR it removed 74 of the 130 training crops and lowered the outer Dice to 0.555 (−0.109, 8/32, ). L3, which starts from the dataset's own labels, matched L0 on Siriapisith AAA/EVAR and reached 0.723 on MosMedData AAA. Of the plan's four expectations, L3 ≥ L2 held on both datasets and L2 ≥ L1 on Siriapisith AAA/EVAR only, while the other two held on neither. These models were trained on Taurus-base labels, so whether labels from Taurus-tuned or Taurus-hybrid, which scored higher in the held-out comparison, close the gap to human labels remains untested.
Table 10: Models trained on Taurus-base labels fell well short of models trained on human labels. Mean over the held-out cases of the dataset's primary metric (MosMedData AAA: mean of lumen and calcium Dice over the classes present; Siriapisith AAA/EVAR: outer Dice), mean ± s.d. over three training seeds, per training label source. The AortaSeg24 runs are still in progress. aTwo seeds; the third is still training.
| Dataset (held-out cases) | L0 human | L1 Taurus-base (auto) | L2 Taurus-base | L2-noedit | L3 reference-seeded |
|---|---|---|---|---|---|
| MosMedData AAA (20) | |||||
| Siriapisith AAA/EVAR (40) |
G Prompts
We summarize the prompts here rather than reproduce them, and the full texts are available from the authors on request. The harness code and the guides call the edit commands verbs and the prepared programs recipes, and the appendices keep these names.
Free-form task. The agent labels one CT volume and works only inside its own directory. It reads a label contract that defines the classes and the vessel ids, and it must write three files on the CT's own grid: a tissue map (background, wall, lumen, calcium, thrombus), a vessel map with one id per labeled voxel, and a verdict file with a status (ok or issue), short issue codes and notes on what it did and what it is unsure about. The wall is a shell of at most 1.5 mm that the agent generates outside aneurysmal sections only. The agent may write and run Python with NumPy, SciPy, scikit-image, nibabel, SimpleITK and Matplotlib and render slices to look at them, but it has no labeling tool and no trained model. It may not read files outside its directory or ask questions, and it must always leave valid output, because an imperfect label scores better than none.
PREPRINT
Reviewer prompts. The three reviewer prompts share one structure. The reviewer reads the harness guide, which is its procedure, claims cases one at a time through the harness, opens the review image (and on whole-body cases the vessel map) before any verdict, and edits only through harness commands. It may read only the guide and the files that harness commands return, so dataset label files and all other folders are off limits. Each case closes with a verdict, issue codes from a fixed list and short factual notes. The prompts differ in budget and procedure. Taurus-base has an edit budget of eight set in the job configuration, and Taurus-tuned adds the dossier and the question cards, with at most 20 turns and 12 image opens per case. Taurus-hybrid allows about 30 turns, 16 image opens and 12 local and 2 global edits, and it adds a second phase of free-form refinement. In that phase the reviewer makes the label follow the half-maximum edge, a smooth surface and the complete extent, and checks each edge on zoomed slices before and after every boundary edit. The Taurus-hybrid prompt prefers the regularization and the prepared recipes to the reviewer's own programs, and it asks for reference-disagreement notes on structures that the CT shows but a lumen-only or trunk-only reference may lack.