Abstract— Improving situational awareness within the Smart Grid is an effective preventive measure to detect potential anomalies, and avoid their adverse consequences. A wide area measurement system (WAMS) based Phasor Measurement Unit (PMU) can assist in improving visibility within the grid by collecting relevant measurements including magnitude, phase angle, frequency, voltage, and current, with a precise GPS-based timestamp. So far, there are more than 2500 PMUs deployed in the North American power grid, where each of which generates between 30 and 60 samples/s, roughly 1.5 TB/month of streamed data. Thus, processing such large PMU streams requires expensive computational resources and faster algorithms. This paper provides state-of-the-art cyber and physical anomalies in the WAMS and analyses their impact on the integrity and availability of the system. Next, it investigates the current anomaly detection approach in historical and streaming PMU data, including conventional machine learning and hybrid approaches, and assesses their advantages and main drawbacks. Lastly, it sheds light on the importance of handling missing PMU data and concept drifts.

Index Terms— WAMS, PMUs, Cyber and Physical anomalies, Machine leaning, Missing data, Concept Drift, Streaming PMU data.

I. INTRODUCTION

In 2015, the Ukraine power system has experienced an outage for several hours impacting 225 000 utility customers. One year later, another cyber-attack was reported on a power control system in another city in Ukraine shutting down substations that controlled 200 megawatts of capacity [1]. These two succeeding events illustrate the threats posed by cyber-attacks and their malicious ability in disturbing the power system and making a negative social-economic impact. One of the reasons behind these cyber-attacks and several major blackouts, especially in North America, is the lack of system awareness and reliable measurements [2].

Smart Grid harnesses the power of information technology to deliver intelligently the power to the end customer and meet wisely the environmental requirements. It allows two-way communications between the end-user and the utility and facilitate the integration of renewable technology. Smart Grid is a distributed, interconnected, and interdependent system. Thus, an event in one part of the grid could impact operations elsewhere. It could also go beyond the grid to affect other system that relies on stable power. Thus, time-synchronized measurements is needed to obtain an accurate real-time estimation of the state of the grid and react quickly to the suspicious events [3].