arXiv:2611.00497cs.LGOct 2026

Manuscript Offprint

arXiv:2611.00497

Where Does EEG Help Wearable Freezing of Gait Detection?

Chuntian Chi, Lifang He, Huajie Shao, Gang Zhou

Chuntian Chi*, Lifang He†, Huajie Shao*, Gang Zhou*

*Department of Computer Science, William & Mary, Williamsburg, VA, USA

†Department of Computer Science, Lehigh University, Bethlehem, PA, USA

Email: {cchi05, hshao, gzhou}@wm.edu, lih319@lehigh.edu

Abstract—Freezing of gait (FoG) detectors built on inertial measurement units (IMUs) are accurate while the legs move, but they become unreliable when the legs are nearly still, which is exactly when akinetic freezing, voluntary stopping, and standing must be told apart. Electroencephalography (EEG) captures motor-planning activity that leg sensors cannot, but EEG is impractical for daily use. We ask where EEG helps: as an input at inference time, or only during pretraining, so that the deployed detector still needs only IMUs. We assemble a pretraining corpus of synchronized EEG and IMU recordings (5 datasets, 184 people, about 94 hours) and compare six settings that differ only in the modalities used for pretraining and as model input, each with tuned hyperparameters and five independent pretraining runs. On the BXHC FoG dataset (leave-one-patient-out, 10 patients with FoG), adding EEG as input raises FoG F1 from 0.663 to 0.740 (9 of 10 patients improve), and the gain in ranking performance is confined to the quartile of windows with the least leg movement (AUROC +0.063). Pretraining the IMU encoder jointly with EEG improves an IMU-only detector both within the cohort (FoG F1 0.663 to 0.705) and when it is trained on a small cohort and tested on another (FoG F1 +0.083, all 10 test patients improve). Repeating the study with PD-only and healthy-only pretraining corpora, each with its own hyperparameter search, shows that IMU-based detection is robust to the corpus, whereas the benefit of aligning EEG with IMU requires both. Cross-cohort analysis further shows that detectors trained without annotated voluntary stops classify nearly all stops as freezing. Finally, on PD versus non-PD classification in three external datasets, joint EEG+IMU pretraining improves PD detection from walking EEG over EEG-only pretraining (AUROC 0.750 vs. 0.683), while IMU-based detection does not depend on the pretraining.

I. INTRODUCTION

Freezing of gait is a brief, episodic absence of effective stepping despite the intention to walk [1]. It causes falls and loss of independence in people with Parkinson's disease (PD), and real-time cueing can shorten episodes, provided that a detector recognizes them reliably [2], [3]. Most detectors use IMUs on the legs or trunk [2], [4], [5], [3], [6]. They work well when freezing changes leg movement, for example the 3–8 Hz trembling of the legs captured by the freezing index [2]. They work less well when the legs are nearly still: akinetic freezing, a voluntary stop, standing, and a slow pivot turn produce similar leg signals, and misclassified turns are a main source of false alarms [3].

EEG adds information that leg sensors lack. Freezing is preceded and accompanied by changes in cortical activity [7], and EEG-based detectors perform well in the laboratory [8]. However, EEG needs a cap and skin contact, which makes

it impractical for daily monitoring [3]. This raises a practical question: if EEG is available only in the laboratory, can it still improve a detector that uses IMUs alone? One route is to use EEG only during pretraining, as privileged information [9], [10]: the IMU encoder learns representations that agree with the simultaneous EEG, and the deployed model needs only IMUs.

In this paper, we compare the two routes under controlled conditions. We study six settings that differ only in which modalities are used for pretraining and which are given to the detector (Table II), using the same data, folds, and evaluation for all of them. Our contributions are:

  • A pretraining corpus of synchronized EEG and IMU recordings from five public datasets (184 people, two PD cohorts with labeled FoG), and a controlled comparison of six pretraining and input settings with tuned hyperparameters and five independent pretraining runs per setting.

  • We show that EEG as model input improves FoG detection mainly in windows with little leg movement, and that this pattern holds when the detector is trained on both PD cohorts.

  • We show that EEG used only during pretraining improves an IMU-only detector, most strongly when it is trained on a small cohort and applied to a different one.

  • We repeat the comparison with PD-only and healthy-only pretraining corpora and show which effects depend on the corpus.

  • We extend the comparison to PD versus non-PD classification on three external datasets with IMU or EEG.

  • We analyze why detectors fail across cohorts: annotated voluntary stops, freezing subtypes, and label conventions differ between datasets.

References (28)