Modeling Fat-shift for Improved Head Segmentation from MRI Scans using a Probabilistic Model

Merle Diedrichsen, Koen Van Leemput, Douglas N. Greve, Oula Puonti, Axel Thielscher

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original. This text is shared under the same licence.

ABSTRACT

Personalized computational head models for biophysical simulations rely on accurate whole-head segmentations from T1-weighted (T1w) magnetic resonance imaging (MRI) scans. While T1w scans provide excellent contrast for intracranial anatomy, extracerebral tissues have partly almost no signal (compact bone) and also suffer from the so-called chemical shift artifact, which affects the fatty tissues in MRI and causes them to spatially shift in the frequency encoding direction of the scan. This artifact occurs primarily in two structures of the head: the spongy bone, a fatty compartment inside the compact bone, and the subcutaneous fat, located directly underneath the skin. The frequency-encoding direction is often set in the superior-inferior direction, causing the fatty tissues to shift down and, as a result, making the skull appear thinner than it actually is. Existing segmentation methods do not model this artifact, consequently leading to inaccurate labeling of the skull and scalp, which introduces a bias in biophysical simulations. The direction and magnitude of the fat-shift can be determined from the scan parameters, thus making it possible to explicitly model the shift and to recover the correct anatomy. This study introduces a probabilistic model that uses variational inference to segment head and brain structures from a T1w scan while accounting for the fat-shift artifact. The proposed Fat-shift-informed Label Optimization of the Whole head (FLOW) method reconstructs extracerebral anatomy more accurately than a fat-shift-agnostic segmentation approach while maintaining high segmentation accuracy in all other structures. FLOW-based fat-shift corrected segmentations significantly reduce bias in electric field simulations compared to a segmentation method that does not model the shift.

Keywords Medical Image Segmentation · Bayesian Inference · MRI · Brain Stimulation

1 Introduction

Automated segmentation of the head and brain anatomy from magnetic resonance imaging (MRI) scans is a necessary first step in many neuroimaging analysis pipelines and required for biophysical simulations relying on subject-specific models of the head anatomy (hereinafter called head models). An important example application is transcranial brain stimulation (TBS), including transcranial electric and magnetic stimulation (TES and TMS). TBS is used to modulate neuronal activity non-invasively to study brain function and as therapy for psychiatric diseases such as depression ([1, 2, 3]). In order to understand the individual variability of TBS effects and to tailor patient-specific treatment protocols, the anatomical accuracy of the underlying head models is critical as it has a strong influence on the spatial distribution and magnitude of the simulated electric field (e-field) [4]. The extracerebral anatomy plays an important role in shaping the e-field distribution, in particular for TES where the current flows between the anode and the cathode, and has to pass through the low-conducting skull to reach the brain [5].

Automated whole-head segmentation methods [6, 7, 8, 9, 10, 11] typically rely on a T1-weighted (T1w) input image for segmentation, although some tools can take advantage of multiple input images [6, 7, 12]. While T1w scans provide excellent soft tissue contrast, they contain almost no bone signal making the skull appear dark. Additionally, T1w scans suffer from the so-called fat-shift artifact, which causes signal from the fatty tissues to appear spatially shifted in the frequency-encoding direction due to the resonance frequency difference between fat and water. The shift can be mitigated by increasing the readout bandwidth, although at the cost of a lower signal-to-noise ratio (SNR), or by using fat suppression, which nulls the signal from fat tissues. However, many research studies and large open-access neuroimaging datasets, such as ADNI [13], UK Biobank [14], OASIS-3 [15] and IXI [16], have acquired T1w scans without fat suppression and with a moderate readout bandwidth, which results in about 1-3 voxel shift in the readout direction. Typically, the frequency encoding direction is chosen to be superior-inferior (SI), meaning that the fatty tissues shift towards the feet in the T1w scans. In scans acquired at high MRI field strength (3T), the artifact is worsened because of a bigger frequency difference between fat and water [17].

The two structures most affected by the fat-shift are subcutaneous fat and a partially fatty compartment within the skull, the spongy bone. The subcutaneous fat is located under the skin and shortly above the skull, which appears bright in non-fat-suppressed T1w scans (see Figure 1). Given the typical fat-shift direction (SI), the subcutaneous fat signal overlaps with the dark skull compartment below it, making the skull appear thinner than it actually is. Similarly, the bright appearing spongy bone, which is a layer of trabecular bone and marrow tissue enclosed in the compact bone of the skull, shifts down and overlays with the inner skull border, effectively blurring the separation between skull and the intracranial space. A shift of a few millimeters of the skull border can result in large changes in the simulated e-field magnitude, which can be up to 30% for TES and 10% for TMS [6]. Thus, the fat-shift effects, when not accounted for, can significantly impact the accuracy of e-field simulations.

Figure

(a) Cryosectional Image

(b) MRI: T1w

Figure 1: An anatomical view of the subcutaneous fat and spongy bone, shown on a cryosectional image (left) and a corresponding T1w MRI scan (right), graphics from the Visible Human Project [18]. The photograph shows the anatomically accurate tissue distribution, with the subcutaneous fat layer surrounding the skull and the spongy bone as an inner compartment of the compact bone. In the T1w scan, which is a 2D acquisition with a fat-shift in the AP direction (back to front), the compact bone borders are blurred by the shifting signal from subcutaneous fat and spongy bone.

To the best of our knowledge, there exists no previous work on modeling and correcting the fat-shift artifact in head segmentations apart from our own previous work [19]. It has been shown that the detrimental bias of the fat-shift on e-field simulations can be alleviated by using a combination of a fat-suppressed T1w scan and high-bandwidth T2w, where the T2w mainly helps with pinning down the inner border of the skull [6]. However, as mentioned above, this combination is not often available as the T1w scans are typically acquired without fat suppression. Dedicated fat segmentation models do exist [20], but these are applied on so-called Dixon MRI scans, which are specifically developed for separating fat, and water signal and do not suffer from the fat-shift artifact. Here, we present the first general purpose modeling pipeline for fat-shift corrected whole-head segmentation, which works with any T1w scan without requiring specific sequence settings. Only the sequence parameters need to be known in order to compute the fat-shift direction and amount in pixels. We extend our previous work presented at the SPIE Medical Imaging conference [19] in several aspects:

  • We extend the initial 2D model to process true 3D MRI data with an updated optimization strategy.

  • We quantify the segmentation performance of brain and non-brain structures on 55 scans from 46 subjects from two different data sets.

  • We quantify the effect of the fat-shift on TES e-field simulations and show that fat-shift corrected segmentations improve the simulation accuracy.