arXiv:2611.01261cs.CLOct 2026

Manuscript Offprint

arXiv:2611.01261

MedAstra: ASR-less Speech Retrieval with Diagnostic Grounding for Medical QA

Elahe Khatibi, Ziyu Wang, Amir M. Rahmani

Abstract

Spoken medical question answering can fail when automatic speech recognition (ASR) corrupts a clinically important term before retrieval. We present MEDASTRA, a framework that maps frozen WavLM speech representations through a lightweight adapter into a frozen E5 text embedding space. This enables a dense retrieval path that accepts a waveform without a query transcript. Retrieved passages and speech-linked textual metadata support answer generation with entity alternatives, diagnostic contrasts, relation heuristics, and bounded retrieval refinement. ASR-less refers to the initial speech retrieval interface; lexical retrieval, string-based entity correction, and the text generator require textual inputs. The deterministic speech embedding does not constitute a calibrated model of acoustic uncertainty. Reported retrieval results reach 87.6 Recall@10 for the speech-only retriever and 90.4 for the hybrid configuration, compared with 81.0 for transcript-first dense retrieval. Medical QA and ablations provide descriptive system comparisons, with input-provenance and evaluation limitations stated explicitly. We distinguish controlled synthetic acoustic tests from real clinical speech, qualify component attribution, and specify the remaining comparisons needed to assess speech-only QA and clinical generalization.

1 Introduction

Speech offers an accessible interface to medical information, but transcript-first retrieval introduces a consequential decision before evidence selection. An ASR system may replace a rare entity, abbreviation, or near-homophone with a familiar term, after which a text retriever searches for the wrong concept. Clinical transcription errors and their effects on retrieval motivate examining this interface separately from final-answer accuracy (Zhou et al., 2018; Sidiropoulos et al., 2022; Wang et al., 2020).

A fluent answer cannot recover information that is absent from its evidence. Figure 1 illustrates this motivation.

MEDASTRA connects speech-to-evidence alignment with medical evidence grounding. Frozen WavLM features (Chen et al., 2022) are projected into a frozen E5 space (Wang et al., 2022); the speech embedding can search both aligned speech items and text passages. A text-based generator consumes readable evidence and optional entity, diagnostic, and relation context. The modular design separates the acoustic retrieval interface from downstream generation.

Two boundaries are essential. First, bypassing a query transcript is not equivalent to eliminating text throughout the system. Speech-linked evidence requires associated text for the current generator, while BM25, text reranking, and edit distance require a text query. Second, a single embedding and a ranked evidence set do not model or calibrate acoustic uncertainty. We therefore describe the system as retaining an acoustic retrieval path and exposing alternative evidence, without claiming probabilistic uncertainty preservation.

Our contributions are (i) a lightweight speech-to-evidence interface between frozen encoders; (ii) an explicit contract between dense speech retrieval and text-dependent grounding; and (iii) an analysis of reported retrieval, acoustic robustness, medical QA, and ablation results with their evidential limits. The study does not establish a fully speech-only medical QA pipeline, clinical safety, or generalization to patient populations. Its clearest empirical question is whether the speech retrieval path can recover evidence that a single ASR transcript misses.

Medical QA also requires evidence that preserves the queried entity and distinguishes plausible answers. A passage about a similar disease may be topically relevant yet lack the decisive contrast. We therefore examine three decisions: which evidence the waveform retrieves, which en-

Figure

Figure 1: Motivation for waveform-based medical evidence retrieval. Crohn's/crown's illustrates a possible ASR substitution, not a recorded benchmark case. The right panel depicts design goals, not established clinical reliability.

tity and diagnostic alternatives reach the prompt, and whether the answer is supported by that visible context. Acoustic retrieval misses, inappropriate term replacements, and unsupported generated claims require different remedies. The targeted entity and diagnosis suites complement broad QA benchmarks by examining these dependencies.

References (32)