Abstract

User simulators generate responses in place of human participants, allowing researchers to estimate the result of a study. To use these estimates before collecting human responses, researchers need a way to assess their reliability. We test whether disagreement among simulators can identify unreliable estimates of a group's response proportions and of differences between groups. We evaluate this signal using 6 language-model simulators and existing GlobalOpinionQA responses for 60 questions in 12 countries. Disagreement predicts invalidity more accurately for differences between two groups than for a single group's response proportions (AUC 0.87 versus 0.71). Errors shared by the simulators remain invisible to this signal. When such an error affects both groups equally, it cancels in the comparison, helping explain the stronger result for group differences. We test this explanation by estimating the shared bias using one set of groups and subtracting it from predictions for a separate set. This correction reduces prediction error without changing disagreement among the simulators. In a retrospective analysis, we simulate referring the 20% of group comparisons with the greatest disagreement for human assessment. Among the remaining comparisons with a conclusive validity judgment, 54.8% are judged invalid, compared with 63.7% before referral.¹

1 Introduction

Researchers use language models to generate responses on behalf of study participants and estimate how a population would respond. This silicon-sampling approach (Argyle et al., 2023; Santurkar et al., 2023) can reduce the work of collecting human responses, provided the simulated estimates support the conclusions researchers would draw from human data. We focus on survey respondents, complementing work on simulated users of search, recommender, and dialogue systems (Zhou et al., 2026; Chen, 2026; Zerhoudi et al., 2026b). A survey study may estimate the proportion choosing an option in one population, which we call a level, or the difference in that proportion between two populations, a contrast.

Existing evaluations show why these estimates need checking. Simulators for agentic tasks are more cooperative and more uniform in style than human participants, overstating measured agent performance (Zhou et al., 2026). Similar differences appear in purchase decisions, where simulated shoppers reproduce buyers' decisions more closely than non-buyers' decisions (Chen, 2026). HumanStudy-Bench assesses simulator fidelity at the study level by comparing simulated estimates and effect sizes with reconstructed human studies while accounting for sampling uncertainty (Liu et al., 2026). Each comparison uses an available human reference to measure simulator error.

For a new study, researchers may need to decide which simulated estimates require human assessment before that reference is available. Disagreement among several simulators could identify unreliable

¹Code and simulator outputs: https://github.com/searchsim-org/neurips26-wrong-together

40th Conference on Neural Information Processing Systems (NeurIPS 2026). Workshop: Grounded User Simulation for Model Evaluation and Training.

estimates, although agreement can conceal an error shared by all models. Can simulator disagreement predict invalid estimates, and does its usefulness differ between levels and contrasts?

We examine this question using 60 GlobalOpinionQA questions (Durmus et al., 2023), 12 countries, and 6 simulators. Disagreement predicts invalidity more accurately for contrasts than for levels. The error decomposition identifies a component shared across simulators and constant across countries, which cancels when two countries are compared.

We define invalidity using an equivalence margin and uncertainty from both human samples and simulator draws (Section 3). We test the shared-error explanation by estimating a question-specific bias on calibration countries and correcting level estimates on separate test countries (Section 5.2). This correction uses human calibration data, while the disagreement score itself uses simulator outputs alone. We then evaluate whether referring high-disagreement contrasts reduces invalidity among the estimates retained for simulation (Section 5.3). All evaluations use existing survey responses.

References (34)