arXiv:2611.01512cs.LGNov 2026

Manuscript Offprint

arXiv:2611.01512

Abstention Spends Its Budget on Local Label Variance More Than on Novelty: Auditing Conformal Calibration and Selective Prediction under Molecular Scaffold Shift

Arnav Srivastava, Krishna Kassetty

ABSTRACT

Selective prediction with split conformal calibration is an attractive post-hoc fix for the translation gap in molecular property prediction: abstain on the least reliable compounds, and the retained set should become trustworthy without retraining. The implicit hope is that abstention concentrates on out-of-distribution chemistry. We audit this recipe for a gradient-boosted fingerprint model on one regression (lipophilicity) and one imbalanced classification (BBBP) endpoint under a Bemis–Murcko scaffold split, holding the fitted model and the evaluation molecules fixed while varying only the calibration fold, over 18 replicates. (i) On lipophilicity, whether conformal calibration restores coverage depends on where the calibration fold comes from: calibrating on held-out molecules from the training scaffolds falls below nominal (PICP 0.841 at a target of 0.90), while calibrating on novel-scaffold molecules recovers it (0.904); on BBBP, coverage stays above nominal in every regime. (ii) For split conformalized quantile regression the conformal correction is a constant, so ranking by interval width is ranking by the base model's quantile width; conformalization does not change what is abstained on. (iii) The abstention score (CQR width on lipophilicity; effectively ensemble variance on BBBP) tracks local label variance more than chemical novelty: controlling for local label variance largely explains away the novelty association (partial Spearman 0.067 and 0.047). (iv) At the pre-specified operating point and across an exploratory sweep of 20 budget-threshold settings, gating on interval width or ensemble variance never improves hit precision over ranking by point prediction; a plain novelty gate shows small, uncorrected gains at the smallest budgets. (v) In an exploratory analysis, exact conformal selection with Benjamini–Hochberg exceeds its false discovery rate target at every level under training-scaffold calibration (FDR 0.303 at q=0.2q=0.2) and is statistically consistent with it under novel-scaffold calibration; its contribution is a data-driven batch size with an error guarantee rather than a better ranking. In these experiments, conformalization earns its keep through guarantees whose validity hinges on calibration provenance, not by choosing what to abstain on.

Keywords Conformal prediction · Selective prediction · Uncertainty quantification · Distribution shift · Scaffold split · Molecular property prediction · Drug discovery

1 Introduction

In design–make–test–learn loops, a property predictor that is accurate on a random split but silently overconfident on a new chemical series spends scarce assay budget on wrong predictions it presents as certain. Uncertainty quantification is the standard response [1, 2], and split conformal prediction [3–6] is especially attractive: it wraps any fitted model, requires no retraining, and delivers a finite-sample, distribution-free coverage guarantee under exchangeability. Paired with selective (reject-option) prediction [7, 8], it promises a decision-aware operating point: abstain on the least reliable fraction and the retained set becomes trustworthy. The implicit hope is that abstention concentrates on out-of-distribution chemistry—novel scaffolds a model should not be confident about.

We audit that hope in a controlled setting. On the same fitted model and the same evaluation molecules, we contrast calibration on held-out molecules from the training scaffolds with calibration on molecules from novel scaffolds, which is exchangeable with the evaluation set. We then ask what the abstention signal selects, whether abstaining improves fixed-budget hit finding, and where conformal guarantees do pay off. We find:

(i) Coverage depends on calibration provenance. On lipophilicity, training-scaffold calibration falls below nominal under scaffold shift, while novel-scaffold calibration recovers it, on identical models and molecules; on BBBP, coverage stays above nominal in every regime (§4.1).

(ii) Conformalization does not change the abstention ranking. For split CQR the calibrated interval is the base quantile interval widened by a constant (Remark 1), so width-based abstention inherits the base model's ranking (§4.2).

(iii) The ranking tracks local label variance more than novelty. Its association with novelty is largely explained away by local label variance, a quantity that mixes measurement noise with structure-activity heterogeneity and itself rises with novelty (§4.2).

(iv) Uncertainty gates do not beat point-prediction ranking at fixed budget. At the pre-specified operating point and across an exploratory sweep, width and ensemble-variance gates are never better and usually significantly worse; a novelty gate is better only at the smallest budgets (§4.3).

(v) FDR control in conformal selection depends on calibration provenance (exploratory). Exact conformal selection [9] exceeds its target at every level under training-scaffold calibration and is consistent with it under novel-scaffold calibration (§4.4).

Findings (i) and (v) confirm, in a controlled comparison, what exchangeability predicts and what drift studies on toxicity data have reported [10]; findings (ii)–(iv) concern what abstention actually selects. The scope is one model family, two endpoints and one scaffold split (§5).

References (36)