Manuscript Offprint

arXiv:2608.23190

Toward a Foundation Plug-and-Play Prior for Computed Tomography Reconstruction via a Multimodal Diffusion Model

Haley Duba-Sullivan, Patxi Fernandez-Zelaia, Obaidullah Rahman, Amirkoushyar Ziabari

Haley Duba-Sullivan

Oak Ridge National Laboratory

Oak Ridge, TN, USA

sullivanhe@ornl.gov

Obaidullah Rahman

Oak Ridge National Laboratory

Oak Ridge, TN, USA

rahmano@ornl.gov

Patxi Fernandez-Zelaia

Oak Ridge National Laboratory

Oak Ridge, TN, USA

fernandezzep@ornl.gov

Amirkoushyar Ziabari

Oak Ridge National Laboratory

Oak Ridge, TN, USA

ziabariak@ornl.gov

Abstract—Computed tomography (CT) throughput is limited by scan time, which grows with both the number of projections acquired and the detector integration time for each. Reconstructing high-quality volumes from sparse-view or low-dose measurements therefore depends on an informative prior, typically a neural network trained for one specific scan setting and retrained whenever the modality, geometry, or material changes. We investigate whether a single diffusion model trained across several imaging domains can instead serve as a prior for many CT problems simultaneously. We evaluate the proposed method using the same frozen model on three datasets that differ in modality, beam geometry, material, and degradation type, spanning flaw analysis in additively manufactured metal parts imaged with cone-beam X-ray CT and concrete microstructure imaged with parallel-beam neutron CT. Our proposed method out-performs analytic reconstructions in all three cases, providing a step toward a reusable foundation prior for heterogeneous CT reconstruction problems.

Index Terms—computed tomography, plug-and-play priors, diffusion models, foundation models, inverse problems

I. INTRODUCTION

COMPUTED tomography (CT) is a critical tool for non-destructive characterization in materials science, from flaw and porosity analysis in additively manufactured (AM) metal parts to neutron characterization of irradiated concrete [1]-[3]. The quality of projections, however, is bounded by acquisition budget as much as by physics. Scan time depends on both the number of projections acquired and the detector integration time spent on each one. These two factors can be reduced independently. Acquiring fewer projections leaves the reconstruction problem ill-posed, creating streaking artifacts in reconstructions from analytic methods such as filtered backprojection (FBP) [4] and Feldkamp-Davis-Kress (FDK) [5]. Shortening the integration time decreases the number of photons recorded in each projection, which reduces the signal-to-noise ratio of the measured data. High-throughput characterization depends on reconstruction methods that are accurate under both sparse-view and low-dose measurements.

Model-based reconstruction methods address this ill-posedness by introducing strong prior models paired with a data-fidelity term [6]–[9]. Recent work has shown that diffusion models are particularly strong priors [10]–[14]. However, these learned priors are often trained for one specific CT scan setting (e.g., modality, scan geometry, and object material), and reconstructions generally degrade significantly when the scan settings change. A common solution is to retrain a prior for each new problem or adapt the prior to the new distribution at test time [15], [16]. Either option is too expensive for practical use at characterization facilities that must image many sample types across several instruments.

In this paper, we work toward a foundation prior model that can be used across a wide variety of CT scan settings without retraining or fine-tuning. Specifically, we use a diffusion vision transformer (ViT) trained across eight imaging domains, ranging from metal AM parts to cell microscopy scans. We analyze plug-and-play (PnP) reconstructions using this prior model on three distinct CT datasets that differ in modality (X-ray and neutron), scan geometry (cone- and parallel-beam), material (nickel and steel AM parts, and concrete microstructure), and degradation type (sparse view and short integration time). The same frozen weights and algorithmic hyperparameters are used for every reconstruction, so only the forward operator changes between problems. Since these factors vary together across the three problems, our experiments establish transfer under their

This manuscript has been authored by UT-Battelle, LLC, under contract DE-AC05-00OR22725 with the US Department of Energy (DOE). The US government retains and the publisher, by accepting the article for publication, acknowledges that the US government retains a nonexclusive, paid-up, irrevocable, worldwide license to publish or reproduce the published form of this manuscript, or allow others to do so, for US government purposes. DOE will provide public access to these results of federally sponsored research in accordance with the DOE Public Access Plan (https://www.energy.gov/doe-public-access-plan).

combined change.

References (44)

  • Enabling rapid X-ray CT characterisation for additive manufacturing using CAD models and deep learning-based reconstruction
  • Using 2.5D super-resolution to improve flaw detection in metal additive manufacturing parts
  • A mesoscale 3d model of irradiated concrete informed via a 2.5 u-net semantic segmentation
  • The Fourier reconstruction of a head section
  • Practical cone-beam algorithm
  • Plug-and-Play priors for model based reconstruction
  • Plug-and-Play ADMM for Image Restoration: Fixed Point Convergence and Applications
  • Plug-and-Play Methods for Integrating Physical and Learned Models in Computational Imaging: Theory, algorithms, and applications
  • Plug-and-Play with 2.5D Artifact Reduction Prior for Fast and Accurate Industrial Computed Tomography Reconstruction
  • Diffusion models as plug-and-play priors
  • Principled probabilistic imaging using diffusion models as plug-and-play priors
  • Plug-and-Play Priors as a Score-Based Method
  • Denoising Diffusion Models for Plug-and-Play Image Restora-tion
  • Cross-Modal Guidance for Fast Diffusion-Based Computed Tomography
  • Deep diffusion image prior for efficient ood adaptation in 3d inverse problems
  • Steerable conditional diffusion for out-of-distribution adaptation in medical image reconstruction
  • Distributed Optimization and Statistical Learning via the Alternating Direction Method of Multipliers
  • Image Denoising by Sparse 3-D Transform-Domain Collaborative Filtering
  • Plug-and-Play Image Restoration with Deep Denoiser Prior
  • Plug-and-Play Methods Provably Converge with Properly Trained Denoisers
  • Denoising diffusion probabilistic models
  • Score-Based Generative Modeling through Stochastic Differential Equations
  • Improved denoising diffusion probabilistic models
  • Elucidating the design space of diffusion-based generative models
  • Solving inverse problems in medical imaging with score-based generative models (opens arXiv in a new tab)
  • Diffusion prior regularized iterative reconstruction for low-dose ct (opens arXiv in a new tab)
  • Solving 3D Inverse Problems Using Pre-Trained 2D Diffusion Models
  • Regularizing INR with Diffusion Prior for Self-Supervised 3D Reconstruction OF Neutron Computed Tomography Data
  • Towards reconstructing experimental sparse-view x-ray ct data with diffusion models (opens arXiv in a new tab)
  • Inversebench: Benchmarking plug-and-play diffusion priors for inverse problems in physical sciences
  • Reconstruct Anything Model: a lightweight foundation model for computational imaging
  • Tomographic Foundation Model—FORCE: Flow-Oriented Reconstruction Conditioning Engine
  • Scalable Diffusion Models with Transformers
  • An Image is Worth 16x16 Words: Transformers for Image Recognition at Scale
  • Denoising Diffusion Implicit Models
  • Beam hardening artifact reduction in x-ray ct reconstruction of 3d printed metal parts leveraging deep learning and cad models
  • Yolo2u-net: Detection-guided 3d instance segmentation for microscopy
  • System and method for artifact reduction of computed tomography reconstruction leveraging artificial intelligence and a priori known model for the object of interest
  • Technical Note: SpekPy v2.0—a software toolkit for modeling x-ray tube spectra
  • A validation of SpekPy: A software toolkit for modelling X-ray tube spectra
  • Differentiable forward projector for x-ray computed tomography (opens arXiv in a new tab)
  • A three-dimensional statistical approach to improved image quality for multislice helical CT
  • Image quality assessment: From error visibility to structural similarity
  • Mr image reconstruction from highly undersampled k-space data by dictionary learning