Gait assessment supports the diagnosis, monitoring, and prognosis of diverse movement-related conditions, such as neurological and musculoskeletal disorders. Recent advances in deep learning using everyday wearable inertial measurement units (IMUs) offer an accessible and low-cost approach to automated gait assessment. However, IMU measurements vary substantially across individuals, body locations, and device configurations, while existing deep learning models are typically developed using small, homogeneous datasets for specific clinical tasks, limiting their robustness and generalizability in diverse real-world contexts. Here we present GaitFM, a cross-modal foundation model for gait assessment using IMU sensors. GaitFM improves the generalizability of gait assessment by transferring knowledge from large vision models and pretraining on unlabeled IMU sensor data. We pretrain GaitFM on a large curated dataset comprising about 4,000 participants and 1.23 million gait windows across diverse clinical and daily conditions, sensor modalities, and body locations. GaitFM demonstrates strong performance across 18 gait-related tasks, including 3 gait parameter estimation tasks, 14 disease and gait abnormality detection tasks, and 1 clinical outcome prediction task. Furthermore, GaitFM generalizes across different sensor configurations and body locations, including those commonly used in clinical settings and everyday wearable devices. These findings demonstrate the effectiveness of transferring visual knowledge in improving sensor-based gait assessment performance, offering a new promising pathway for addressing data scarcity in the sensor and medical domains.
Introduction
Neurological and musculoskeletal disorders pose a growing global health burden. Current projections indicate that Parkinson's disease (a neurological disorder) will affect more than 14 million people worldwide by 2040¹, while the number of osteoarthritis cases (a musculoskeletal disorder) is expected to increase by 49–95% by 2050². Among individuals with these conditions, alterations in the characteristic pattern of movement during walking, i.e., gait impairment, are a common clinical manifestation and can be among their most disabling and distressing features³⁻¹¹. In addition, evidence indicates that gait patterns evolve with symptom severity¹²,¹³ and can provide information about future clinical risks¹⁴,¹⁵. Therefore, quantitative gait assessment, which objectively characterizes fine-grained walking patterns, has become an important clinical tool for detecting and evaluating disorders³⁻¹⁰, monitoring disease progression¹⁶,¹⁷, and predicting adverse clinical outcomes¹⁸,¹⁹.
Conventional gait assessment typically relies on either observational clinical scales or instrumented laboratory analysis. In the former, patients perform standardized tasks in a hospital or clinic, and trained assessors visually evaluate and score their movements²⁰⁻²². Although readily accessible, these assessments are inherently subjective and can vary across observers²³⁻²⁵. Instrumented gait analysis provides more detailed and objective measurements of gait kinematics and kinetics, but generally requires specialized facilities, expensive systems such as optical motion-capture platforms, and trained personnel²⁶,²⁷. These examinations are time-consuming and can be particularly burdensome for individuals with limited mobility. More importantly, both approaches capture only brief snapshots of gait under controlled conditions and can therefore miss subtle, intermittent or context-dependent abnormalities that emerge during daily life¹⁹.
Data-driven deep learning (DL) models offer a path towards automated gait assessment by learning clinically relevant patterns directly from gait-related data, thereby reducing reliance on manual evaluation and complex analytical pipelines. Existing DL-based methods have leveraged sensing modalities such as vision²⁷,²⁸ and floor sensors²⁹ to characterize gait patterns. However, vision-based measurements can be sensitive to environmental conditions³⁰, whereas floor-based systems restrict assessment to instrumented spaces. Wearable sensors, such as force sensors , electromyography (EMG) sensors , and inertial measurement units (IMUs) , offer opportunities for continuous gait monitoring in daily life . Among these modalities, IMUs are particularly suitable for scalable gait assessment because they are widely integrated into everyday consumer devices and can capture fine-grained body movement at low cost . However, existing IMU-based gait studies typically rely on heterogeneous datasets that vary in sensing devices, body locations, sensor combinations, and acquisition protocols . As a result, models developed for specific sensor configurations and clinical tasks often exhibit limited generalizability . Realizing the potential of IMU-based gait assessment therefore requires a unified framework that can learn generalizable representations across diverse sensor configurations and gait-related tasks.
Foundation models offer a promising solution to addressing this challenge by learning robust and generalizable representations through self-supervised pretraining on large-scale datasets, which can then be reused across diverse sensor configurations, body locations, and downstream tasks. The success of this paradigm has been demonstrated by large language models (LLMs) and large vision models (LVMs) , with growing applications in medical domains such as pathology , radiology , spatial proteomics , and sleep medicine . However, its application to IMU-based gait assessment is constrained by the scarcity of sufficiently large and diverse gait data for pretraining. This scarcity is partly attributable to the sensitive nature of IMU sensor data, as stringent privacy regulations and requirements for protecting health information complicate data collection, management and sharing . Cross-modal knowledge transfer offers a promising solution to this challenge. Previous studies have demonstrated the effectiveness of transferring knowledge from data-rich to data-scarce modalities in alleviating data scarcity and substantially improving downstream task performance . Against this background, we investigate the potential of transferring knowledge learned from natural images to IMU-based gait assessment tasks.
Here we introduce GaitFM, a foundation model that transfers knowledge from the image modality to the sensor modality, for robust gait assessment in both clinical and everyday settings. GaitFM employs a Transformer-based masked autoencoder (MAE) architecture . To address the scarcity of gait IMU data, GaitFM designs cross-modal knowledge transfer by first pretraining on a large-scale natural image dataset and then continually pretraining on a gait IMU dataset curated from about 4,000 participants. Across tasks spanning gait parameter estimation, disease and abnormality diagnosis, and clinical outcome prediction, we show that GaitFM consistently benefits from visual pretraining and outperforms conventional end-to-end models. Notably, GaitFM demonstrates strong generalizability to external datasets not encountered during sensor pretraining. Beyond these performance gains, GaitFM accommodates varying numbers and placements of sensors, allowing a single model to operate across heterogeneous consumer and clinical wearable devices, thereby enhancing its adaptability for low-cost gait assessment in daily environments. We further show that visual representations provide a powerful source of transferable knowledge to mitigate sensor-data scarcity, support learning local gait patterns and relationships between sensor modalities, improve downstream data efficiency, and enable sensor representation learning to benefit from scaling advances in the vision domain.
A foundation model for gait monitoring
GaitFM employs a cross-modality transfer learning framework designed to leverage pretrained knowledge from the data-rich visual domain to alleviate data scarcity in IMU sensing and learn generalizable gait representations. We initialize the Transformer-based MAE architecture with weights pretrained via masked image reconstruction on the large-scale ImageNet-1K dataset , which contains about 1.28 million natural images spanning 1,000 classes (Fig. 1a). To bridge the structural differences between images and sensor data, we introduce a sensor-to-image embedder that transforms raw IMU data into image-like representations compatible with the pretrained visual encoder (Fig. 1b). We then continue pretraining the model through masked sensor reconstruction on a curated gait IMU dataset comprising approximately 4,000 participants and more than 1.23 million gait windows recorded across diverse body locations (Fig. 1b, d).

Figure 1. Overview of the GaitFM framework. a, GaitFM adopts a masked autoencoder (MAE) architecture initialized with weights pretrained on ImageNet-1K, comprising approximately 1.28 million natural images across 1,000 classes. b, A sensor-to-image embedder enables continued MAE pretraining on a curated gait dataset comprising approximately 4,000 participants and 1.23 million IMU gait windows from seven heterogeneous datasets. c, Fine-tuning of GaitFM for downstream gait assessment tasks. GaitFM accommodates varying sensor placements and modality combinations, supporting flexible gait assessment across clinical and daily settings. The downstream tasks encompass gait parameter estimation, disease and abnormality diagnosis, and clinical outcome prediction. d, Distribution of samples across sensor placements.
For downstream tasks, the sensor-to-image embedder and the pretrained MAE encoder are retained, whereas the decoder is discarded and replaced with task-specific layers (Fig. 1c). For gait parameter estimation tasks, the latent embeddings produced by the pretrained encoder are processed by a residual network (ResNet)-based prediction head before regression. For disease and abnormality diagnosis and clinical outcome prediction tasks, the encoder embeddings are fed into lightweight multilayer perceptron (MLP) heads for classification or prediction. The sensor-to-image embedder and MAE encoder independently process each body-location input to generate latent embeddings, which are subsequently aggregated and passed to the downstream layers. We randomly sample subsets of body locations and sensor modalities as model inputs during fine-tuning, allowing GaitFM to generalize across dynamic sensor combinations and input configurations without retraining.
GaitFM generalizes across diverse healthcare tasks
We systematically benchmark GaitFM on 18 downstream tasks across seven internal (included in pretraining) and four external datasets (not included in pretraining). These tasks span three application domains: gait parameter estimation (including gait speed, step length, and step time estimation), disease and abnormality diagnosis a

b
C
d
e
f
g
Figure 2. GaitFM achieves strong performance across diverse gait assessment tasks and benefits from pretrained visual knowledge. a,b, Comparison of gait parameter estimation tasks on the internal Mobilise-D dataset and the external GaitPrint dataset. a, Coefficient of determination ( ) for identical model architectures with and without visual pretraining, demonstrating the benefits of pretrained visual knowledge on gait parameter estimation tasks. b, Mean absolute error (MAE) comparison across three gait parameter estimation tasks. c,d, Area under the receiver operating characteristic curve (AUROC) for disease and gait abnormality diagnosis tasks on six internal datasets (ClinicalGait, FoGContest, Mobilise-D, mPower, COMPWALK-ACL and WearGait-PD) and two external datasets (FoG-STAR and StrokeRehabilitation). c, Performance comparison across disease and gait abnormality diagnosis tasks. d, Comparison of identical model architectures with and without visual pretraining, demonstrating the benefits of pretrained visual knowledge on disease and gait abnormality diagnosis tasks. e, t-SNE visualization of learned representations for frailty diagnosis in the GSTRIDE dataset. GaitFM achieves a higher silhouette score than end-to-end models and its counterpart without visual pretraining, indicating improved separation between classes. f,g, AUROC for clinical outcome prediction task on the internal GSTRIDE dataset and the external LTMM dataset. f, Performance comparison on clinical outcome prediction task. g, Comparison of identical model architectures with and without visual pretraining, demonstrating the benefits of pretrained visual knowledge on clinical outcome prediction task. Error bars denote 95% confidence intervals (CIs) obtained from 1,000 bootstrap resamples. P values are calculated using paired bootstrapping (b) and two-sided Wilcoxon signed-rank tests (c and f).
(including disease classification and grading, episode detection, and progression assessment), and clinical outcome prediction (including fall risk prediction). Gait parameter estimation is formulated as regression task, whereas disease and abnormality diagnosis and clinical outcome prediction are formulated as classification task.
Across all tasks, we compare GaitFM with GaitFM (Scratch), an architecture-matched MAE model that undergoes the same sensor pretraining but is randomly initialized rather than from vision pretrained weights. This comparison isolates the contribution of cross-modal vision knowledge transfer. For regression, we additionally compare GaitFM with end-to-end fully convolutional network (FCN) , ResNet and Transformer . For classification, the baseline models include DeepConvLSTM , Informer , and Non-stationary Transformer .
Gait parameter estimation. We evaluate gait parameter estimation tasks on the internal Mobilise-D dataset and the external GaitPrint dataset , using gait speed, step length, and step time as regression targets. Mobilise-D provides accelerometer and gyroscope measurements from a sensor worn on the lower back, whereas GaitPrint provides measurements from five locations: the head, both wrists and both thighs.
Compared with GaitFM (Scratch), GaitFM increases by 0.234 ( ), 0.149, and 0.191 ( ) for the three respective targets on Mobilise-D (Fig. 2a). The corresponding improvements on GaitPrint are 0.059, 0.354, and 0.023 ( ). These gains indicate that visual knowledge can be effectively transferred to improve gait parameter estimation tasks. GaitFM also outperforms the conventional end-to-end regression models (Fig. 2b). Compared with the best-performing conventional baseline, it reduces MAE by 0.031 ( ), 0.059 ( ) and 0.016 ( ) for gait speed, step time and step length, respectively, on Mobilise-D. In addition, GaitFM maintains strong performance on the external GaitPrint dataset, highlighting its ability to generalize gait parameter estimation across independent cohorts.
Disease and abnormality diagnosis. We evaluate GaitFM on six internal datasets (ClinicalGait , Mobilise-D , mPower , COMPWALK-ACL , FoGContest and WearGait-PD ) and two external datasets (FoG-STAR and StrokeRehabilitation ). For neurological and musculoskeletal disease diagnosis, ClinicalGait provided accelerometer and gyroscope measurements from the head, waist and both feet for seven tasks: hip osteoarthritis, knee osteoarthritis, anterior cruciate ligament injury, cerebrovascular accident, Parkinson's disease, peripheral neuropathy and leukoencephalopathy. Mobilise-D provided lower-back accelerometer and gyroscope measurements for four tasks: Parkinson's disease, multiple sclerosis, chronic obstructive pulmonary disease or congestive heart failure. mPower provides accelerometer and gyroscope measurements from a smartphone carried in the trouser pocket for Parkinson's disease diagnosis. COMPWALK-ACL contained accelerometer and gyroscope measurements from seven lower-body locations, comprising the waist, both thighs, both shins and both feet, for anterior cruciate ligament injury diagnosis. WearGait-PD provided accelerometer and gyroscope measurements from the head, both wrists and both thighs for Parkinson's disease diagnosis. For disease episode detection, we evaluate freezing-of-gait (FoG) detection using back-mounted accelerometer data from FoGContest and accelerometer and gyroscope data from the wrist, lower back and both ankles in FoG-STAR. For post-disease recovery assessment, accelerometer data collected from both feet, both wrists and the sacral region in the StrokeRehabilitation dataset were used to evaluate recovery following stroke.
For disease diagnosis, GaitFM improves mean AUROC over the best-performing conventional baseline by 0.078 (P < 0.01) on ClinicalGait and 0.104 (P < 0.01) on Mobilise-D, with results averaged across seven and four diagnostic tasks, respectively. It further improves AUROC by 0.112 (P < 0.001) on mPower, 0.078 (P < 0.001) on COMPWALK-ACL and 0.121 (P < 0.001) on WearGait-PD. For episode detection of FoG, GaitFM improves AUROC by 0.063 (P < 0.001) on FoGContest and 0.149 (P < 0.001) on the external FoG-STAR dataset. For recovery assessment, we evaluate post-stroke functional recovery on the external StrokeRehabilitation dataset. GaitFM achieves an AUROC of 0.816, outperforming the best-performing conventional baseline by 0.214 (P < 0.001). We then examine the contribution of vision-pretrained weights to disease and abnormality diagnosis. Across all eight datasets, cross-modal visual knowledge increases AUROC by 0.025-0.683 (P < 0.001) compared with GaitFM (Scratch) (Fig. 2d). These consistent improvements demonstrate the effectiveness of transferring visual knowledge to disease and abnormality diagnosis tasks. To assess representation quality, we visualize the embeddings learned for frailty diagnosis on GSTRIDE using t-distributed stochastic neighbour embedding (t-SNE, Fig. 2e). GaitFM achieves the highest silhouette coefficient (0.74 versus 0.67 for the second-best model), indicating better separation between classes in the learned representation space. Moreover, compared with GaitFM (Scratch), GaitFM also yields clearer separation between normal and abnormal gait (0.74 versus 0.37), indicating that visual knowledge improves their discriminability.
Clinical outcome prediction. We use the fall-risk prediction task to evaluate GaitFM for clinical outcome prediction under two settings. In the internal GSTRIDE dataset, foot-mounted accelerometer and gyroscope measurements were used to predict falls within one year. In the external LTMM dataset, one-year fall risk was predicted from lower-back accelerometer measurements.
GaitFM achieves the highest AUROC in both settings, outperforming the best-performing conventional end-to-end baseline by 0.051 on GSTRIDE () and 0.018 on LTMM (Fig. 2f). Vision-pretrained weights increase AUROC from 0.777 to 0.847 () on GSTRIDE and from 0.357 to 0.589 on LTMM, corresponding to absolute gains of 0.071 and 0.232, respectively (Fig. 2g). These gains indicate that visual knowledge can be effectively transferred to improve performance on the clinical outcome prediction task.
GaitFM generalizes across dynamic sensor combinations
Sensor configurations vary substantially in their number, anatomical placement and sensing modality across real-world settings. A robust gait foundation model should therefore accommodate this variability without retraining or architectural modification . We assess GaitFM across dynamic combinations of sensor locations and modalities within a unified framework. We further examine the feasibility of accessible, low-cost gait assessment using sensor placements corresponding to everyday wearable devices.
Performance under dedicated sensor location settings. We first evaluate the ability of GaitFM to accommodate varying numbers and combinations of dedicated gait-analysis IMU sensors. The evaluation comprises ClinicalGait (7 diagnostic tasks and dynamic combinations of 4 sensor locations), COMPWALK-ACL (ACL diagnosis and combinations of 7 lower-limb locations), FoG-STAR (FoG detection and combinations of 4 locations) and StrokeRehabilitation (post-stroke recovery assessment and combinations of 5 locations). ClinicalGait, COMPWALK-ACL and FoG-STAR provide both accelerometer and gyroscope measurements, whereas StrokeRehabilitation provides accelerometer measurements only. Across these datasets, GaitFM outperforms conventional end-to-end models under varying numbers and configurations of sensor locations (Fig. 3a). Performance generally improves as additional locations are incorporated, indicating that GaitFM effectively integrates complementary information across body locations without retraining or architectural modification. Furthermore, as shown in Fig. 3b, vision-pretrained knowledge consistently improves performance across all sensor-location combinations, demonstrating its effective transfer to diverse sensor configurations.
Performance under daily sensor location settings. We further investigate the potential of IMU data collected from locations corresponding to everyday wearable devices for gait analysis. We select five body locations from WearGait-PD and GaitPrint: bilateral wrist recordings serve as proxies for smartwatches, bilateral upper-thigh recordings as proxies for smartphones, and head-mounted recordings as proxies for ear-worn devices or smart glasses. GaitFM maintains strong performance across these sensor configurations for PD diagnosis on WearGait-PD and gait parameter estimation on GaitPrint (Fig. 3c), supporting the feasibility of gait assessment using everyday consumer devices. Moreover, vision-pretrained knowledge consistently improves performance across all combinations of daily sensor locations (Fig. 3d), demonstrating that cross-modal visual knowledge remains transferable across daily sensor configurations.
Knowledge transfer from vision models enhances IMU-based gait learning
Traditional foundation models typically require large-scale datasets to learn robust and generalizable representations that can adapt to diverse scenarios and downstream tasks. However, this requirement is difficult to apply to

b
C
d
Step time estimation GaitPrint dataset (n=8)
Step length estimation GaitPrint dataset (n=8)
Figure 3. GaitFM accommodates dynamic sensor-location configurations without retraining. a, Performance on disease and abnormality diagnosis tasks across dynamic combinations of dedicated sensor locations in ClinicalGait, COMPWALK-ACL, FoG-STAR and StrokeRehabilitation. b, Contribution of vision-pretrained knowledge under dynamic combinations of dedicated sensor locations. c, PD diagnosis on WearGait-PD and gait-parameter estimation on GaitPrint across different combinations of simulated sensor placements representative of everyday wearable devices (left and right trouser pockets, left and right wrists, and head). d, Contribution of vision-pretrained knowledge to PD diagnosis and gait parameter estimation, under dynamic combinations available in everyday wearable devices.
IMU-based gait assessment because large-scale gait data remain scarce. We demonstrate that visual pretraining provides a powerful source of transferable knowledge that substantially improves sensor data understanding, thereby reducing the model's dependence on large-scale sensor datasets and labeled downstream data.
Visual knowledge provides a powerful source of modality knowledge for mitigating sensor-data scarcity. To evaluate the effectiveness of visual knowledge as a source for IMU-based gait assessment tasks, we compared GaitFM with foundation models pretrained on other modalities: (1) BioPM , pretrained on daily-life IMU data, (2) Chronos , pretrained on general time-series data, and (3) NormWear , pretrained on physiological data. Each model was initialized with its original pretrained weights and further pretrained on the same gait training set as GaitFM, following its respective pretraining strategy. As shown in Fig. 4a, we evaluated the models on four downstream tasks: FoG episode detection (FoGContest), Parkinson's disease diagnosis (mPower), fall-risk prediction (GSTRIDE), and step-length estimation (Mobilise-D). GaitFM achieves performance comparable to or better than that of these models across tasks, supporting the effectiveness of visual knowledge as a source of transferable knowledge for IMU-based gait assessment.
Visual knowledge helps model capture local gait patterns and cross-modal relationships. To assess how visual knowledge affects GaitFM's ability to understand sensor data, we evaluated masked sensor image reconstruction under three input settings: accelerometer and gyroscope data (acc + gyro, Fig. 4b left), accelerometer data only (acc only, Fig. 4b middle), and gyroscope data only (gyro only, Fig. 4b right). The reconstruction MSE is shown

b
C
d
e
f
FoG detection task
FoGContest dataset (n=13)

PD diagnosis task mPower dataset (n=620)
Fall risk assessment task GSTRIDE dataset (n=32)
Step length estimation Mobilise-D dataset (n=21)
Figure 4. Visual knowledge transfer enhances IMU-based gait representation learning and data efficiency. a, Performance comparison of GaitFM with foundation models pretrained on other modalities: general time-series data (Chronos ), wearable physiological data (NormWear ), and daily-life IMU data (BioPM ). Each model was initialized with its original pretrained weights and then further pretrained on the same gait training set used for GaitFM. GaitFM achieves performance comparable to or better than that of these models, demonstrating the transferability of visual knowledge to sensor-data modeling. b, Representative examples of masked sensor image reconstruction with accelerometer and gyroscope data (acc + gyro, left), accelerometer data only (acc only, middle), and gyroscope data only (gyro only, right). c, Reconstruction loss of GaitFM with and without visual knowledge (Scratch). Visual knowledge reduces reconstruction loss across all three input settings, suggesting that it helps GaitFM capture local sensor patterns and cross-modality correlations. d,e, Effect of model scale on classification and regression tasks, evaluated using the Tiny, Base, Large, and Huge variants of the LVM. Validation loss is shown as a function of model size for FoG episode detection (FoGContest) and Parkinson's disease diagnosis (mPower, d), as well as gait-speed, step-length, and step-time estimation (Mobilise-D, e). f, Data efficiency of GaitFM and GaitFM (Scratch) when fine-tuned with 5%, 10%, 20%, 50%, and 100% of the downstream training data. Across FoG episode detection (FoGContest), Parkinson's disease diagnosis (mPower), fall-risk prediction (GSTRIDE), and step-length estimation (Mobilise-D), GaitFM with visual knowledge consistently achieves better performance, demonstrating improved data efficiency through visual knowledge transfer.
in Fig. 4c. In the acc + gyro setting, GaitFM reduces the MSE from 0.909 to 0.462 compared with GaitFM (Scratch), suggesting that visual knowledge helps the model capture local patterns in sensor data. In the acc-only and gyro-only settings, the MSE decreases from 0.910 to 0.726 and from 0.975 to 0.764, respectively. These reductions suggest that visual knowledge also helps GaitFM capture relationships between accelerometer and gyroscope data. Taken together, these results demonstrate the effectiveness of visual knowledge in improving models' understanding of IMU sensor data.
Gait assessment tasks benefit from the scaling behavior of LVMs. To examine how the scale of the visual model affects its ability to model IMU sensor data, we evaluated GaitFM variants built on Tiny, Base, Large, and Huge LVM backbones. As shown in Fig. 4d, validation loss decreases with increasing model size for both FoG episode detection (FoGContest) and Parkinson's disease diagnosis (mPower). Fig. 4e shows a similar trend for the regression tasks on Mobilise-D: validation loss decreases with model size for gait-speed, step-length, and step-time estimation. These results suggest that sensor-based gait assessment tasks can benefit from scaling LVMs, highlighting the potential of transferring visual knowledge to mitigate the scarcity of gait IMU data.
Visual knowledge improves downstream data efficiency of gait assessment tasks. To evaluate how visual knowledge affects performance when labeled downstream data are limited, we fine-tuned GaitFM and GaitFM (Scratch) using 5%, 10%, 20%, 50%, and 100% of the training data for each task. As shown in Fig. 4f, GaitFM with visual knowledge consistently outperforms GaitFM (Scratch) across FoG episode detection (FoGContest), Parkinson's disease diagnosis (mPower), fall-risk prediction (GSTRIDE), and step-length estimation (Mobilise-D). This advantage, including at smaller training-data fractions, demonstrates that visual knowledge improves the data efficiency of IMU-based gait assessment.
Discussion
Implications
Most existing IMU-based gait analysis models learn representations tailored to specific sensor configurations, body locations, or tasks, resulting in a fragmented landscape that limits their robustness and generalizability in diverse real-world settings. Here, we introduce GaitFM, a unified foundation model specifically designed for IMU-based gait analysis. GaitFM learns generalizable representations that transfer across tasks, sensor placements, and modalities, supporting gait assessment in settings ranging from clinical care to everyday life. Evaluated on 18 gait-related tasks (3 gait parameter estimation tasks, 14 disease and gait abnormality detection tasks, and 1 clinical outcome prediction task) across 11 heterogeneous datasets, GaitFM outperforms end-to-end task-specific models. GaitFM also supports flexible combinations of sensor inputs from different body locations and outperforms conventional models that rely on fixed sensor configurations. In summary, GaitFM offers a promising approach to addressing fragmentation in current digital health systems and therefore advancing the field.
Our experiments further suggest that general representation priors learned from the data-rich vision modality can be transferred to IMU data when an appropriate interface between the domains is established. In GaitFM, sensor-to-image representations and continued MAE pretraining enable visual knowledge to support gait assessment. Specifically, our results show that visual knowledge (1) provides powerful and transferable priors that help address sensor-data scarcity, (2) helps GaitFM capture local gait patterns and cross-modal relationships, and (3) improves the data efficiency of downstream gait-assessment tasks. We also show that (4) gait-assessment performance benefits from the scaling behavior of LVMs. These findings point to a complementary strategy for alleviating sensor-data scarcity and improving generalization: identifying broadly reusable knowledge and developing effective ways to transfer it across modalities, beyond collecting large datasets. This strategy may also provide a useful blueprint for other areas of sensor-based research, where physiological and behavioral sensing face similar constraints, such as limited labeled data and heterogeneous scenarios and devices.
Clinically, GaitFM may be particularly valuable in resource-limited settings and for remote assessment. Compared with clinician-administered observational scales and instrumented gait analysis in laboratory settings, an IMU-based foundation model offers a unified framework for low-cost, automated gait assessment that may be more accessible to primary-care facilities and underserved communities. Moreover, smartphones, smartwatches, and earbuds are also more widely available than instrumented walkways, motion-capture systems, and professional wearable platforms. Our evaluation of these everyday devices for gait assessment points to the potential for remote, at-home monitoring, particularly for patients whose gait impairments make travel to clinical facilities difficult.
Limitations
This study has several limitations. First, the curated dataset does not cover the full spectrum of gait-related disorders. The included cohorts also differ in population characteristics, acquisition protocols, sensor hardware, and clinical definitions. Although this heterogeneity enables more comprehensive evaluation, it may introduce dataset-specific confounders and result in uneven representation across diseases and demographic groups. Future work should include additional neurological, musculoskeletal, and age-related disorders, with more balanced representation across age, sex, ethnicity, disease severity, and comorbidities. Second, the mechanisms underlying cross-modal transfer remain incompletely understood. It is not yet clear which visual priors are transferred to sensor representations or why they are beneficial. Future studies can improve the interpretability of the transfer process and identify the visual knowledge that contributes to sensor-data understanding. Despite this uncertainty, our complementary analyses provide initial evidence from multiple perspectives that visual knowledge can improve the understanding of IMU data, laying a foundation for further research. Third, this study provides an early proof of concept and establishes the technical feasibility of GaitFM. Clinical translation will require prospective studies to evaluate its performance and utility in real-world settings.
Despite these limitations, this study represents a notable advance in IMU-based human gait analysis by improving performance across gait-related tasks, enabling flexible use of sensor configurations, and reducing reliance on large-scale sensor datasets. These contributions may help advance gait assessment technologies and potentially support more accessible, reliable, and low-cost remote gait assessment.
Methods
Dataset and preprocessing
We curated 11 IMU-based gait datasets comprising 3,973 participants. The datasets were heterogeneous in sensor modality (accelerometer only or accelerometer and gyroscope), recorded gait activities (differing in walking types), device type (research-grade IMUs and IMUs embedded in consumer electronics), sensor placement combinations (1-14 locations), populations (differing in age, sex, and health status), and acquisition protocol (free-living, predefined tasks, and controlled lab settings).
To harmonize data across datasets, all signals were resampled to 50 Hz, divided into non-overlapping 5-s windows and standardized using z-score normalization. This preprocessing yielded approximately 1.23 million single-location windows. For datasets containing simultaneous recordings from multiple locations, we enumerated all available combinations of sensor locations. For datasets providing both accelerometer and gyroscope measurements, we randomly masked the gyroscope channels with a probability of 0.5 during pretraining and training, exposing the model to both accelerometer-only and multimodal inputs. These procedures exposed the model to varying numbers and placements of sensors, allowing it to accommodate different sensor configurations without retraining.
Participants were assigned to training, validation and test sets in a 6:2:2 ratio, with all samples from each participant restricted to a single partition to prevent data leakage. The training partitions of the seven internal datasets were used for both model pretraining and downstream fine-tuning. For the four external datasets, the training partitions were used only for downstream fine-tuning.
GaitFM architecture and pretraining
Sensor-to-Image embedder. We first transform each raw IMU window into an image-like representation using a sensor-to-image embedder. Let denote an IMU window, where and represent the number of sensor channels and sequence length, respectively. Each sensor channel is treated as an independent univariate sequence by reshaping the input from to .
A shared one-dimensional convolution is then applied independently to each sensor channel. The convolution uses s = 10 for both its kernel size and stride and produces 3s output channels. Its weights are constrained to be non-negative and to sum to one along the temporal dimension. Specifically,
where denotes the same-padded input, indexes the convolutional output channels, and indexes the temporal segments, with . The resulting temporal embedding is denoted by . Because the convolutional filters are shared across all sensor channels, the same temporal transformation is applied to each channel. We then rearrange into a three-channel image tensor :
The resulting representation is bilinearly resized to , independently min-max normalized within each image channel and mapped to the range .
Sensor-masked pretraining. We continue pretraining a Vision Transformer (ViT) initialized with ImageNet-1K-pretrained weights using the sensor-derived images. Each sensor image is divided into non-overlapping patches, of which 75% are randomly masked, leaving only the visible tokens to be processed by the encoder. This high masking ratio limits reliance on locally redundant information and encourages the model to reconstruct the missing content by learning complex dependencies among the visible tokens. Moreover, processing only 25% of the tokens substantially reduces the computational cost of pretraining.
Sensor encoder. The patch-embedding layer flattens each image patch and maps it through a shared linear projection into a -dimensional token embedding. Positional embeddings are added to each token to preserve its spatial position within the sensor image. Following masking, a learnable classification token is prepended to the visible token sequence, which is then processed by a stack of Transformer encoder blocks. Each block comprises multi-head self-attention and a feed-forward network with residual connections and layer normalization, allowing the encoder to capture dependencies across sensor channels and temporal regions. The encoder produces a classification token and a set of sensor tokens .
Sensor decoder. The sensor decoder reconstructs the masked sensor-image patches from the encoded visible tokens. It first maps the encoder output into the decoder embedding space through a linear projection. A learnable mask token is then inserted at each masked position, and the complete token sequence is restored to its original spatial order. Positional embeddings are added to the reordered tokens, which are subsequently processed by a stack of Transformer decoder blocks followed by layer normalization. A final linear projection maps each decoded sensor token to a predicted patch , where is the number of pixel values within a patch. The classification token is excluded from patch prediction.
For each target patch , we normalize its elements using the patch-specific mean and variance . The reconstruction loss is computed only over the set of masked patches :
where denotes the stop-gradient operation and is a small constant for numerical stability. The sensor decoder is used only during pretraining.
Adaptation to downstream tasks
Two key capabilities of foundation models are (i) learning generalizable representations from raw data that can be transferred across downstream tasks and (ii) accommodating flexible input formats. To evaluate these capabilities, we assess the pretrained GaitFM across multiple clinical applications and dynamic sensor inputs.
Dynamic-input fine-tuning. For downstream evaluation, we discard the sensor decoder and retain the pretrained sensor-to-image embedder and sensor encoder, both of which are updated through full-parameter fine-tuning. Each available sensor location is processed independently by the shared sensor-to-image embedder and sensor encoder. A task-specific location representation is extracted from the encoder outputs and combined with a learnable location embedding to preserve anatomical information. The resulting representations are assigned to fixed slots according to their sensor locations, while slots corresponding to unavailable locations are filled with zeros. A binary availability mask indicates which slots contain valid inputs. The fixed-slot representations are flattened and concatenated with to form a fixed-dimensional representation , which is passed to the corresponding task-specific prediction head. This design accommodates different numbers and combinations of sensor locations within a unified architecture.
Task-specific adaptation of pretrained models. We consider downstream tasks spanning three clinical application domains: gait parameter estimation, disease and abnormality diagnosis, and clinical outcome prediction. Gait parameter estimation is formulated as a regression task, whereas disease and abnormality diagnosis and clinical outcome prediction are formulated as classification tasks. We use distinct task-specific adaptation strategies for these two task categories, as described below.
Classification tasks. For classification tasks, the CLS token from each sensor location serves as its location representation . The resulting dynamic input representation is passed to a multilayer perceptron (MLP) classifier to produce class logits. The sensor-to-image embedder, sensor encoder, location embeddings and MLP classifier are jointly optimized using the cross-entropy loss.
Regression tasks. For regression tasks, the sensor tokens from each sensor location are processed by a residual neural network (ResNet) to obtain the corresponding location representation . The fused dynamic-input representation is then used to produce a continuous prediction . The sensor-to-image embedder, sensor encoder, location embeddings and ResNet regressor are jointly optimized using the smooth loss.
Experimental settings
Implementation of pretraining. GaitFM is pretrained for 5 epochs on NVIDIA RTX PRO 6000 GPUs using the Adam optimizer with a global batch size of 2048. The initial learning rate is set to and decayed by a factor of 0.5 according to the type-1 learning-rate schedule. We use and no weight decay.
Implementation of downstream tasks. For regression tasks, the end-to-end baseline models use a learning rate of and a batch size of 64. GaitFM uses separate learning rates of for the sensor-to-image embedder and sensor encoder and for the regression head, with a batch size of 128. For classification tasks, the end-to-end baseline models use a learning rate of and a batch size of 128. GaitFM uses learning rates of for the sensor-to-image embedder and sensor encoder and for the MLP classification head and location embeddings, with a batch size of 128. All models are optimized with AdamW and trained on NVIDIA RTX PRO 6000 GPUs.
Evaluation metrics
For classification tasks, we evaluate performance using the area under the receiver operating characteristic curve (AUROC) at the subject level. For FoGContest, we use sample-level AUROC to reflect symptom-event monitoring. We also use sample-level AUROC for FoG-STAR and StrokeRehabilitation because these datasets include few subjects. For regression tasks, we report sample-level mean absolute error (MAE) and the coefficient of determination (). Error bars denote 95% CIs.
Statistical analysis
The 95% CIs were estimated using non-parametric bootstrapping with 1,000 resamples. For regression tasks, pairwise differences between models were assessed using paired bootstrap tests with 1,000 resamples. For classification tasks, pairwise differences were assessed using two-sided Wilcoxon signed-rank tests. Values of were considered statistically significant, with thresholds of and reported where applicable.
Data availability
The ImageNet-1K dataset used for vision pretraining is available online (https://huggingface.co/datasets/ILSVRC/imagenet-1k). The sensor pretraining and internal validation datasets, GSTRIDE (https://zenodo.org/records/17052815), FoGContest (https://zenodo.org/records/10959560), COMPWALK-ACL (https://zenodo.org/records/15624356), mPower (https://www.synapse.org/Synapse:syn4993293/wiki/), WearGait-PD (https://www.synapse.org/Synapse:syn52540892/wiki/623751), Mobilise-D (https://zenodo.org/records/13899386), and ClinicalGait (https://doi.org/10.6084/m9.figshare.28806086) are all available online. The external validation datasets LTMM (https://physionet.org/content/ltmm/1.0.0/), FoG-STAR (https://zenodo.org/records/17838806), StrokeRehabilitation (https://zenodo.org/records/10534055), and GaitPrint (https://springernature.figshare.com/articles/dataset/NONAN_GaitPrint_An_IMU_gait_database_of_healthy_middle-aged_adults/29371796) are all available online as well.
Code availability
The source code and pretrained model are available on GitHub at https://github.com/saiketa/GaitFM.
References
[1] V Tabar, H Sarva, AM Lozano, A Fasano, SK Kalia, KKH Yu, C Brennan, Y Ma, S Peng, D Eidelberg, et al. Phase i trial of hes cell-derived dopaminergic neurons for parkinson's disease. Nature, 641(8064):978–983, 2025.
[2] Jaimie D Steinmetz, Garland T Culbreth, Lydia M Haile, Quinn Rafferty, Justin Lo, Kai Glenn Fukutaki, Jessica A Cruz, Amanda E Smith, Stein Emil Vollset, Peter M Brooks, et al. Global, regional, and national burden of osteoarthritis, 1990–2020 and projections to 2050: a systematic analysis for the global burden of disease study 2021. The Lancet Rheumatology, 5(9):e508–e522, 2023.
[3] Anat Mirelman, Paolo Bonato, Richard Camicioli, Terry D Ellis, Nir Giladi, Jamie L Hamilton, Chris J Hass, Jeffrey M Hausdorff, Elisa Pelosin, and Quincy J Almeida. Gait impairments in parkinson's disease. The Lancet Neurology, 18(7):697–708, 2019.
[4] Yohann Thenaisie, Kyuhwa Lee, Charlotte Moerman, Stefano Scafa, Andrea Gálvez, Elvira Pirondini, Morgane Burri, Jimmy Ravier, Alessandro Puiatti, Ettore Accolla, et al. Principles of gait encoding in the subthalamic nucleus of people with parkinson's disease. Science translational medicine, 14(661):eabo1800, 2022.
[5] Christopher Buckley, Lisa Alcock, Ríona McArdle, Rana Zia Ur Rehman, Silvia Del Din, Claudia Mazzà, Alison J Yarnall, and Lynn Rochester. The role of movement analysis in diagnosing and monitoring neurodegenerative conditions: insights from gait and postural control. Brain sciences, 9(2):34, 2019.
[6] TF Winters, JR Gage, and R Hicks. Gait patterns in spastic hemiplegia in children and young adults. J Bone Joint Surg Am, 69(3):437–441, 1987.
[7] Kathryn Mills, Michael A Hunt, and Reed Ferber. Biomechanical deviations during level walking associated with knee osteoarthritis: a systematic review and meta-analysis. Arthritis care & research, 65(10):1643–1665, 2013.
[8] Kenton R Kaufman, Christine Hughes, Bernard F Morrey, Michael Morrey, and Kai-Nan An. Gait characteristics of patients with knee osteoarthritis. Journal of biomechanics, 34(7):907–915, 2001.
[9] Harvi F Hart, Adam G Culvenor, Natalie J Collins, David C Ackland, Sallie M Cowan, Zuzana Machotka, and Kay M Crossley. Knee kinematics and joint moments during gait following anterior cruciate ligament reconstruction: a systematic review and meta-analysis. British journal of sports medicine, 50(10):597–612, 2016.
[10] Nicolas de l'Escalopier, Cyril Voisard, Mona Michaud, Albane Moreau, Sylvain Jung, Brian Tervil, Nicolas Vayatis, Laurent Oudre, and Damien Ricard. Evaluation methods to assess the efficacy of equinovarus foot surgery on the gait of post-stroke hemiplegic patients: a literature review. Frontiers in Neurology, 13:1042667, 2022.
[11] Arjun Balachandar, Gianluca Sorrento, Eduardo M Moraud, Marco Bonizzato, and Alfonso Fasano. Neuromodulation for gait disorders. Nature Reviews Bioengineering, pages 1–17, 2026.
[12] Yingcheng Liu, Guo Zhang, Christopher G Tarolli, Rumen Hristov, Stella Jensen-Roberts, Emma M Waddell, Taylor L Myers, Meghan E Pawlik, Julia M Soto, Renee M Wilson, et al. Monitoring gait at home with radio waves in parkinson's disease: A marker of severity, progression, and medication response. Science Translational Medicine, 14(663):eadc9669, 2022.
[13] Brook Galna, Sue Lord, David J Burn, and Lynn Rochester. Progression of gait dysfunction in incident parkinson's disease: impact of medication and phenotype. Movement Disorders, 30(3):359–367, 2015.
[14] Stephanie Studenski, Subashan Perera, Kushang Patel, Caterina Rosano, Kimberly Faulkner, Marco Inzitari, Jennifer Brach, Julie Chandler, Peggy Cawthon, Elizabeth Barrett Connor, et al. Gait speed and survival in older adults. Jama, 305(1):50–58, 2011.
[15] Joe Verghese, Roee Holtzer, Richard B Lipton, and Cuiling Wang. Quantitative gait markers and incident fall risk in older adults. Journals of Gerontology Series A: Biomedical Sciences and Medical Sciences, 64(8): 896–901, 2009.
[16] Sandra J Olney and Carol Richards. Hemiparetic gait following stroke. part i: Characteristics. Gait & posture, 4(2):136–148, 1996.
[17] Amit Salomon, Eran Gazit, Pieter Ginis, Baurzhan Urazalinov, Hirokazu Takoi, Taiki Yamaguchi, Shuhei Goda, David Lander, Julien Lacombe, Aditya Kumar Sinha, et al. A machine learning contest enhances automated freezing of gait detection and reveals time-of-day effects. Nature Communications, 15(1):4853, 2024.
[18] Brian E Maki. Gait changes in older adults: predictors of falls or indicators of fear? Journal of the American geriatrics society, 45(3):313–320, 1997.
[19] Kevin Albert Kasper, Ryan Thien, Tucker Stuart, John Kim, Aman Bhatia, and Philipp Gutruf. Wearable ai for on-device frailty assessment. Nature Communications, 2025.
[20] Christopher G Goetz, Barbara C Tilley, Stephanie R Shaftman, Glenn T Stebbins, Stanley Fahn, Pablo Martinez-Martin, Werner Poewe, Cristina Sampaio, Matthew B Stern, Richard Dodel, et al. Movement disorder society-sponsored revision of the unified parkinson's disease rating scale (mds-updrs): scale presentation and clinimetric testing results. Movement disorders: official journal of the Movement Disorder Society, 23(15):2129–2170, 2008.
[21] T Schmitz-Hubsch, S Tezenas Du Montcel, L Baliko, J Berciano, S Boesch, Chantal Depondt, P Giunti, C Globas, J Infante, J-S Kang, et al. Scale for the assessment and rating of ataxia: development of a new clinical scale. Neurology, 66(11):1717–1720, 2006.
[22] Femke Hulzinga, Alice Nieuwboer, Bauke W Dijkstra, Martina Mancini, Carolien Strouwen, Bastiaan R Bloem, and Pieter Ginis. The new freezing of gait questionnaire: unsuitable as an outcome in clinical trials? Movement disorders clinical practice, 7(2):199–205, 2020.
[23] Mark A Albanese, William R Clarke, Harold P Adams Jr, and Robert F Woolson. Ensuring reliability of outcome measures in multicenter clinical trials of treatments for acute ischemic stroke. the program developed for the trial of org 10172 in acute stroke treatment (toast). Stroke, 25(9):1746–1751, 1994.
[24] Christopher G Goetz and Glenn T Stebbins. Assuring interrater reliability for the updrs motor section: utility of the updrs teaching tape. Movement Disorders, 19(12):1453–1456, 2004.
[25] SH Subramony, W May, D Lynch, C Gomez, K Fischbeck, M Hallett, P Taylor, R Wilson, and T Ashizawa. Measuring friedreich ataxia: interrater reliability of a neurologic rating scale. Neurology, 64(7):1261–1262, 2005.
[26] Tian Tan, Tom Van Wouwe, Keenon F Werling, C Karen Liu, Scott L Delp, Jennifer L Hicks, and Akshay S Chaudhari. Gaitdynamics: A generative foundation model for analyzing human walking and running. Nature Biomedical Engineering, pages 1–13, 2026.
[27] Yasunori Yamada, Masatomo Kobayashi, Kaoru Shinkawa, Erhan Bilal, James Liao, Miyuki Nemoto, Miho Ota, Kiyotaka Nemoto, and Tetsuaki Arai. Utility of synthetic musculoskeletal gaits for generalizable healthcare applications. Nature Communications, 16(1):6188, 2025.
[28] Łukasz Kidziński, Bryan Yang, Jennifer L Hicks, Apoorva Rajagopal, Scott L Delp, and Michael H Schwartz. Deep neural networks enable quantitative movement analysis using single-camera videos. Nature communications, 11(1):4054, 2020.
[29] Qiongfeng Shi, Zixuan Zhang, Tianyiyi He, Zhongda Sun, Bingjie Wang, Yuqin Feng, Xuechuan Shan, Budiman Salam, and Chengkuo Lee. Deep learning enabled smart mats as a scalable floor monitoring system. Nature communications, 11(1):4609, 2020.
[30] Jairo H Migueles, Cristina Cadenas-Sanchez, Ulf Ekelund, Christine Delisle Nyström, Jose Mora-Gonzalez, Marie Löf, Idoia Labayen, Jonatan R Ruiz, and Francisco B Ortega. Accelerometer data collection and processing criteria to assess physical activity and other outcomes: a systematic review and practical considerations. Sports medicine, 47(9):1821–1845, 2017.
[31] Jinmei Liu, Fanyu Zhang, Jiongyao Xu, Shengyang Jia, Nuanyang Cui, Rusen Yang, Weiwei Wang, and Long Gu. Unveiling the synergistic mechanism of cf and c-cl bonds in enhancing the triboelectric performance of fluorinated polymers. Nature Communications, 2026.
[32] Kyun Kyu Kim, Tomasz J Zaluska, Six Skov, Yeongjun Lee, Hyunchang Park, Donglai Zhong, Muhammad Khatib, Yuya Nishio, Yuanwen Jiang, Scott L Delp, et al. A simplified wearable device powered by a generative emg network for hand-gesture recognition and gait prediction. Nature Sensors, 1(1):27–38, 2026.
[33] Steve Nguyen, Andrea Z LaCroix, Kathleen M Hayden, Chongzhi Di, Priya Palta, Marcia L Stefanick, JoAnn E Manson, Stephen R Rapp, Michael J LaMonte, and John Bellettiere. Accelerometer-measured physical activity and sitting with incident mild cognitive impairment or probable dementia among older women. Alzheimer's & Dementia, 19(7):3041–3054, 2023.
[34] Balasundaram Kadirvelu, Constantinos Gavriel, Sathiji Nageshwaran, Jackson Ping Kei Chan, Suran Nethisinghe, Stavros Athanasopoulos, Valeria Ricotti, Thomas Voit, Paola Giunti, Richard Festenstein, et al. A wearable motion capture suit and machine learning predict disease progression in friedreich's ataxia. Nature medicine, 29(1):86–94, 2023.
[35] Ann-Kathrin Schalkamp, Kathryn J Peall, Neil A Harrison, and Cynthia Sandor. Wearable movement-tracking data identify parkinson's disease years before clinical diagnosis. Nature medicine, 29(8):2048–2056, 2023.
[36] Lorenzo Brognara, Pierpaolo Palumbo, Bernd Grimm, and Luca Palmerini. Assessing gait in parkinson's disease using wearable motion sensors: a systematic review. Diseases, 7(1):18, 2019.
[37] Lu Bai, Matthew G Pepper, Yong Yan, Sarah K Spurgeon, Mohamed Sakel, and Malcolm Phillips. Quantitative assessment of upper limb motion in neurorehabilitation utilizing inertial sensors. IEEE Transactions on Neural Systems and Rehabilitation Engineering, 23(2):232–243, 2014.
[38] Rishi Bommasani, Drew A Hudson, Ehsan Adeli, Russ Altman, Simran Arora, Sydney von Arx, Michael S Bernstein, Jeannette Bohg, Antoine Bosselut, Emma Brunskill, et al. On the opportunities and risks of foundation models. arXiv preprint arXiv:2108.07258, 2021.
[39] Hanwen Xu, Naoto Usuyama, Jaspreet Bagga, Sheng Zhang, Rajesh Rao, Tristan Naumann, Cliff Wong, Zelalem Gero, Javier González, Yu Gu, et al. A whole-slide foundation model for digital pathology from real-world data. Nature, 630(8015):181–188, 2024.
[40] Richard J Chen, Tong Ding, Ming Y Lu, Drew FK Williamson, Guillaume Jaume, Andrew H Song, Bowen Chen, Andrew Zhang, Daniel Shao, Muhammad Shaban, et al. Towards a general-purpose foundation model for computational pathology. Nature medicine, 30(3):850–862, 2024.
[41] Xiyue Wang, Junhan Zhao, Eliana Marostica, Wei Yuan, Jietian Jin, Jiayu Zhang, Ruijiang Li, Hongping Tang, Kanran Wang, Yu Li, et al. A pathology foundation model for cancer diagnosis and prognosis prediction. Nature, 634(8035):970–978, 2024.
[42] Chaoyi Wu, Xiaoman Zhang, Ya Zhang, Hui Hui, Yanfeng Wang, and Weidi Xie. Towards generalist foundation model for radiology by leveraging web-scale 2d&3d medical data. Nature Communications, 16(1):7866, 2025.
[43] Johann Wenckstern, Eeshaan Jain, Benedikt von Querfurth, Yexiang Cheng, Kiril Vasilev, Matteo Pariset, Phil F Cheng, Petros Liakopoulos, Olivier Michielin, Andreas Wicki, et al. The virtual tissues foundation model resolves spatial proteomics across scales. Nature, pages 1–11, 2026.
[44] Rahul Thapa, Magnus Ruud Kjaer, Bryan He, Ian Covert, Hyatt Moore IV, Umaer Hanif, Gauri Ganjoo, M Brandon Westover, Poul Jennum, Andreas Brink-Kjaer, et al. A multimodal sleep foundation model for disease prediction. Nature Medicine, 32(2):752–762, 2026.
[45] Petru-Daniel Tudosiu, Walter HL Pinaya, Pedro Ferreira Da Costa, Jessica Dafflon, Ashay Patel, Pedro Borges, Virginia Fernandez, Mark S Graham, Robert J Gray, Parashkev Nachev, et al. Realistic morphology-preserving generative modelling of the brain. Nature Machine Intelligence, 6(7):811–819, 2024.
[46] Zelin Qiu, Xi Wang, Zhuoyao Xie, Juan Zhou, Yu Wang, Lingjie Yang, Xinrui Jiang, Juyoung Bae, Moo Hyun Son, Qiang Ye, et al. Large-scale multi-sequence pretraining for generalizable mri analysis in versatile clinical applications. Nature Biomedical Engineering, pages 1–13, 2026.
[47] Zhongxu Zhuang, Biao Xue, Qiang An, Hui Chu, Yue Zhang, Rui Chen, Jing Xu, Ning Ding, Xiaochuan Cui, E Wang, et al. Advancing sleep health equity through deep learning on large-scale nocturnal respiratory signals. Nature Communications, 16(1):9334, 2025.
[48] Zhen He, Shuofeng Hu, Yaowen Chen, Sijing An, Jiahao Zhou, Runyan Liu, Junfeng Shi, Jing Wang, Guohua Dong, Jinhui Shi, et al. Mosaic integration and knowledge transfer of single-cell multimodal data with midas. Nature Biotechnology, 42(10):1594–1605, 2024.
[49] Yulin Sun, Xiaopeng Si, Runnan He, Xiao Hu, Peter Smielewski, Wenlong Wang, Xiaoguang Tong, Wei Yue, Meijun Pang, Kuo Zhang, et al. An automated classifier of harmful brain activities for clinical usage based on a vision-inspired pre-trained framework. npj Digital Medicine, 8(1):768, 2025.
[50] Kaiming He, Xinlei Chen, Saining Xie, Yanghao Li, Piotr Dollár, and Ross Girshick. Masked autoencoders are scalable vision learners. In Proceedings of the IEEE/CVF conference on computer vision and pattern recognition, pages 16000–16009, 2022.
[51] Jia Deng, Wei Dong, Richard Socher, Li-Jia Li, Kai Li, and Li Fei-Fei. Imagenet: A large-scale hierarchical image database. In 2009 IEEE conference on computer vision and pattern recognition, pages 248–255. IEEE, 2009.
[52] Zhiguang Wang, Weizhong Yan, and Tim Oates. Time series classification from scratch with deep neural networks: A strong baseline. In 2017 International joint conference on neural networks (IJCNN), pages 1578–1585. IEEE, 2017.
[53] Alexander Katrompas, Theodoros Ntakouris, and Vangelis Metsis. Recurrence and self-attention vs the transformer for time-series classification: A comparative study. In International Conference on Artificial Intelligence in Medicine, pages 99–109. Springer, 2022.
[54] Francisco Javier Ordóñez and Daniel Roggen. Deep convolutional and lstm recurrent neural networks for multimodal wearable activity recognition. Sensors, 16(1):115, 2016.
[55] Haoyi Zhou, Shanghang Zhang, Jieqi Peng, Shuai Zhang, Jianxin Li, Hui Xiong, and Wancai Zhang. Informer: Beyond efficient transformer for long sequence time-series forecasting. In Proceedings of the AAAI conference on artificial intelligence, volume 35, pages 11106–11115, 2021.
[56] Yong Liu, Haixu Wu, Jianmin Wang, and Mingsheng Long. Non-stationary transformers: Exploring the stationarity in time series forecasting. In Alice H. Oh, Alekh Agarwal, Danielle Belgrave, and Kyunghyun Cho, editors, Advances in Neural Information Processing Systems, 2022.
[57] Claudia Mazzà, Lisa Alcock, Kamiar Aminian, Clemens Becker, Stefano Bertuletti, Tecla Bonci, Philip Brown, Marina Brozgol, Ellen Buckley, Anne-Elie Carsin, et al. Technical validation of real-world monitoring of gait: a multicentric observational study. BMJ open, 11(12):e050785, 2021.
[58] Tyler M Wiles, Seung Kyeom Kim, Madhur Mangalam, Joel H Sommerfeld, Kolby J Brink, Alli Grunkemeyer, Marilena Kalaitzi Manifrenti, Anaelle E Charles, Narges Shakerian, Mehrnoush Haghighatnejad, et al. Nonan gaitprint: An imu gait database of healthy older adults. Scientific Data, 12(1):143, 2025.
[59] Cyril Voisard, Rémi Barrois, Nicolas de l'Escalopier, Nicolas Vayatis, Pierre-Paul Vidal, Alain Yelnik, Damien Ricard, and Laurent Oudre. A dataset of clinical gait signals with wearable sensors from healthy, neurological, and orthopedic cohorts. Scientific Data, 12(1):1674, 2025.
[60] Brian M Bot, Christine Suver, Elias Chaibub Neto, Michael Kellen, Arno Klein, Christopher Bare, Megan Doerr, Abhishek Pratap, John Wilbanks, E Dorsey, et al. The mpower study, parkinson disease mobile data collected using researchkit. Scientific data, 3(1):160011, 2016.
[61] Tomer Yona, Bezalel Peskin, and Arielle Fischer. the compwalk-acl: a dataset of multi-pace imu gait kinematics in adolescents, adults, and acl injured patients. Scientific Data, 13(1):4, 2025.
[62] Anthony J Anderson, David Eguren, Michael A Gonzalez, Naima Khan, Sophia Watkinson, Michael Caiola, Siegfried S Hirczy, Cyrus P Zabetian, Kelly Mills, Emile Moukheiber, et al. Weargait-pd: An open-access wearables dataset for gait in parkinson's disease and age-matched controls. medrxiv, pages 2024–09, 2024.
[63] Luigi Borzi, Florenc Demrozi, Ruggero Angelo Bacchin, Cristian Turetta, Michele Tebaldi, Luis Sigcha, Samaneh Zolfaghari, Domiziana Rinaldi, Giuliana Fazzina, Giulio Balestro, et al. A multi-level annotated sensor dataset of gait freezing manifestations and severity in parkinson's disease. Scientific Data, 2026.
[64] Lin Zhou, Torsten Rackoll, Lennard Ekrod, Mircea-Gheorghe Balc, Fabian Klostermann, Bert Arnrich, and Alexander H. Nave. Dataset for monitoring and visualizing stroke rehabilitation progress using wearable sensors (imu), January 2024. URL https://doi.org/10.5281/zenodo.10534055.
[65] Xiao Gu, Wei Tang, Jinpei Han, Veer Sangha, Fenglin Liu, Shreyank N Gowda, Antonio H Ribeiro, Patrick Schwab, Kim Branson, Lei Clifton, et al. Cardiac health assessment across scenarios and devices using a multimodal foundation model pretrained on data from 1.7 million individuals. Nature Machine Intelligence, 8(2):220–233, 2026.
[66] Yizhou Bian, Shichao Ding, Catherine R Jutzeler, Sheng Xu, Noé Brasier, and Joseph Wang. Improving multimodal wearable sensing for healthcare with artificial intelligence. Nature Biotechnology, pages 1–4, 2026.
[67] Abdul Fatir Ansari, Lorenzo Stella, Ali Caner Turkmen, Xiyuan Zhang, Pedro Mercado, Huibin Shen, Oleksandr Shchur, Syama Sundar Rangapuram, Sebastian Pineda Arango, Shubham Kapoor, Jasper Zschiegner, Danielle C. Maddix, Hao Wang, Michael W. Mahoney, Kari Torkkola, Andrew Gordon Wilson, Michael Bohlke-Schneider, and Bernie Wang. Chronos: Learning the language of time series. Transactions on Machine Learning Research, 2024. ISSN 2835-8856.
[68] Yunfei Luo, Yuliang Chen, Asif Salekin, and Tauhidur Rahman. Toward foundation model for multivariate wearable sensing of physiological signals. ACM Transactions on Computing for Healthcare, 7(3):1–43, 2026.
[69] Prithviraj Tarale, Kiet Chu, Abhishek Varghese, Kai-Chun Liu, Maxwell A Xu, Mohit Iyyer, and Sunghoon Lee. Bio-inspired self-supervised learning for wrist-worn accelerometer data. In Forty-third International Conference on Machine Learning, 2026.
[70] Guillermo García-Villamil Neira, Marta Neira Álvarez, Elisabet Huertas-Hoyas, Luisa Ruiz-Ruiz, Sara García-de Villa, Antonio J Del-Ama, María Cristina Rodríguez Sánchez, and Antonio R Jiménez Ruiz. Gstride: A database of frailty and functional assessments with inertial gait data from elderly fallers and non-fallers populations. 2022.
[71] Aner Weiss, Marina Brozgol, Moran Dorfman, Talia Herman, Shirley Shema, Nir Giladi, and Jeffrey M Hausdorff. Does the evaluation of gait quality during daily life provide insight into fall risk? a novel approach using 3-day accelerometer recordings. Neurorehabilitation and neural repair, 27(8):742–752, 2013.