Manuscript Offprint
arXiv:2611.01974MUPAS: Multimodal Unified Perception with Asymmetric Attention for Stress Assessment
MUPA²S: Multimodal Unified Perception with Asymmetric Attention for Stress Assessment
Stefanos Gkikas
Honda Research Institute Japan
Wako City, Japan
stefanos.gkikas@jp.honda-ri.com
Thomas Kassiotis
Department of Electronic Engineering
Hellenic Mediterranean University
Chania, Greece
Yu Fang
Honda Research Institute Japan
Wako City, Japan
Christian Arzate Cruz
Honda Research Institute Japan
Wako City, Japan
christian.arzate@jp.honda-ri.com
Miao Cheng
Research Institute of Electrical Communication
Tohoku University
Sendai, Japan
Zongyi Jiang
University of Canberra
Canberra, Australia
Zacharias Kamarianakis
Department of Electronic Engineering
Hellenic Mediterranean University
Chania, Greece
Houshyar Asadi
College of Science & Engineering
Flinders University
Adelaide, Australia
houshyar.asadi@flinders.edu.au
Randy Gomez
Honda Research Institute Japan
Wako City, Japan
Raul Fernandez Rojas
BioSIS (Biosensing & Intelligent Systems) Lab
Centre for Intelligent Computing and Systems
University of Canberra
Canberra, Australia
raul.fernandezrojas@canberra.edu.au
Giorgos Giannakakis
Department of Electronic Engineering
Hellenic Mediterranean University
Chania, Greece
Abstract—Stress is a leading contributor to long-term physical and mental health decline. The automatic assessment of stress is a promising approach for continuous monitoring and mitigating human biases. However, the development of automated systems remains challenging due to the heterogeneity of physiological and behavioral signals. This paper presents MUPA²S, a multimodal framework for automatic stress assessment that combines facial video and ECG signals within a unified perception architecture. Both modalities are mapped into a shared token representation without modality-specific components, and processed through asymmetric attention comprising segment-local cross-attention and global self-attention across segment states. Experiments on a newly collected 58-subject stress dataset, evaluated under a stratified subject-level protocol, show that facial video achieves 69.44% test accuracy, while ECG-only performance remains close to chance under the proposed representation. Unified Video–ECG fusion achieves a test accuracy of 69.58% at approximately half the number of parameters of feature-level fusion, with negligible additional computational cost. Feature-level fusion does not exceed the video-only baseline, while unified input-level integration provides a parameter-efficient mechanism for jointly processing the two modalities.
Index Terms—Stress recognition, mental health, affective computing, electrocardiography, transformer
Stress is a growing global health concern. Analysis of nationally representative surveys across 146 countries found that the likelihood of stress reporting doubled over 18 years, with increasing disparities across gender, age, and income groups [4]. Furthermore, psychosocial work exposures contribute substantially to cardiovascular disease and depression across 28 European countries [5]. In settings requiring continuous or unobtrusive monitoring, conventional stress assessment remains limited. Self-reports may be impractical, delayed, or biased, whereas contact-based wearable systems face compliance, motion-artifact, and scalability challenges [6]. Moreover, naturalistic deployments reveal persistent issues with data quality and signal integrity [7]. These limitations motivate automated, non-intrusive systems capable of passively and objectively recognizing stress from readily available signals [8].
Stress recognition has been studied across physiological and behavioral modalities. ECG and EDA reflect autonomic arousal, although inter-individual variability limits generalization [9]. Facial behavior offers a contact-free alternative through eye, mouth, and head activity [10] or Facial Action Units [11], [12]. Deep learning [13] and multimodal fusion [14] have further improved recognition. Facial video and biosignals were recently combined for driver stress estimation [15], using 3D facial descriptors with cross-modal attention. In contrast, the present study maps facial video frames and ECG into a shared representation processed by a single asymmetric-attention backbone without modality-specific encoders, and is evaluated across multiple stress-induction conditions rather than a driving protocol.
II. RELATED WORK
Early work on video-based stress recognition relied on handcrafted facial cues, including eye activity, mouth movements, head-motion parameters, and camera-derived heart rate information, demonstrating that these cues can distinguish stressed and anxious states from neutral or relaxed ones [10]. The adoption of deep learning shifted video-based stress recognition toward learned face- and action-level representations, outperforming handcrafted feature-engineering approaches on a video-based stress dataset [16]. Spatiotemporal deep architectures have been proposed to improve facial image-based stress recognition by modeling facial information across regions and over time [17]. Facial Action Units provide an interpretable intermediate representation for stress recognition; AU-based models have been applied to distinguish stressed from neutral states in a contact-free manner [11]. More recently, the integration of explainable AI techniques into AU-based stress recognition has enabled identification of the specific AUs that drive predictions, improving both model transparency and physiological interpretability [18].
Physiological signals provide complementary indices of stress-related autonomic activity and are less directly dependent on overt facial behavior [8]. Heart rate variability derived from ECG has been widely studied as a marker of autonomic stress regulation [8]; pairwise transformations and feature-selection strategies applied to HRV features have been used to improve stress classification performance [19]. ECG has also been studied in biometric recognition under different psychological stress states, showing that stress-related changes in cardiac dynamics affect subject-specific ECG representations and motivate identity-aware modeling [20]. Multi-signal approaches combining EEG and ECG highlight the challenge of inter-individual variability in physiological stress responses and motivate personalized machine learning strategies for more generalizable models [9]. Despite high accuracy in controlled
settings, wearable affect-monitoring systems face challenges in unconstrained environments, where motion artifacts and signal quality degradation limit deployment in practice [21].
Given the limitations of each modality considered in isolation, multimodal approaches have attracted growing interest as fusion frameworks can exploit complementary physiological and behavioral information for stress recognition. A hybrid deep learning and handcrafted-feature fusion system that combines ECG and EDA signals has been shown to outperform unimodal baselines in a leave-one-out cross-validation on the WESAD dataset [22]. Deep learning architectures fusing ECG, facial expressions, and voice have demonstrated that matrix eigenvector-based cross-modal fusion captures acute stress dynamics more effectively than individual streams [14]. In a simulated office environment, the combination of cardiac, mouse, and keyboard features with interpretable machine learning has enabled multi-level stress detection, showing that behavioral interaction signals carry stress-related information beyond physiological channels alone [23]. The fusion of facial video and cardiovascular signals has recently been explored for stress estimation in diverse scenarios, including driving, where cross-modal attention mechanisms align temporal facial and physiological dynamics during distracted-driving stressors [15]. Comprehensive surveys of deep learning for stress detection identify multimodal fusion as a prominent direction for improving robustness and performance across heterogeneous datasets and protocols [13].
Regarding the modeling of stress, early approaches relied predominantly on classical machine learning, where statistical, temporal, and frequency-domain features were extracted from the signals and fed to classifiers such as Decision Trees, Random Forests, AdaBoost, and Linear Discriminant Analysis [24], while the recognized physical activity of the user has been incorporated as context to distinguish psychological stress from similar physiological arousal in daily-life settings [25]. With the adoption of deep learning, end-to-end architectures based on convolutional and recurrent layers have been employed to learn representations directly from raw physiological signals, achieving results comparable to or better than feature-based pipelines while removing the need for manual feature engineering [26]. Furthermore, self-supervised learning has been introduced to reduce the dependence on labeled data, with networks pre-trained to recognize transformations applied to unlabeled ECG signals and subsequently transferred to the classification of stress and other affective states [27]. More recently, transformer-based architectures have been utilized, either combining convolutional layers with a transformer encoder to detect stress directly from ECG [28], or employing a shared transformer encoder pre-trained in a self-supervised manner to capture correlations within and across multiple wearable signals [29].
III. METHODOLOGY
A. Unified Perception
The framework maps heterogeneous inputs into a shared token representation without modality-specific architectures, enabling a single model to process both behavioral and physiological signals. For a video sequence of frames, each frame is a RGB image. Rather than processing frames sequentially, the temporal dimension is folded into the channel dimension—a step referred to as axis folding—creating a tensor of shape . This preserves the spatial structure of each frame while packing the temporal structure into a single 2D representation. For ECG, the 1D waveform is first mean-centered and standardized, min-max normalized to , represented as a grid, and bilinearly interpolated to , yielding a single-channel 2D representation. The two representations are concatenated along the channel dimension:
where denotes the batch size and . Geometric information is incorporated by encoding each spatial position using Fourier features. The model uses frequency bands and a maximum frequency . Since the input has spatial axes, the Fourier encoding adds positional features. The encoding is:
where spans . The spatial axes are flattened into a sequence of tokens, with data channels and positional features concatenated per token to form the token matrix:
where denotes the number of spatial axes. Since and , the token dimension becomes:
The token sequence is partitioned into contiguous segments of length . These settings are fixed across all experiments. Fourier features preserve spatial-position information after flattening the representation, while divides the 50176 tokens into four equal groups of 12544 tokens for local cross-attention before global interaction among the segment states. The ECG interpolation maps the 1D waveform to the same domain as the folded video, enabling direct channel-level integration within a single shared architecture. The tokens of segment are denoted . Similar approaches of unified perception fusing heterogeneous modalities via interpolation can be found [30], [31], showing their efficacy and efficiency for human state recognition.
B. Asymmetric Attention
The model processes the segmented token sequence through four layers, each comprising a cross-attention block followed by self-attention blocks. A single latent state is associated with each segment, instantiated at runtime by replicating a shared initialization vector derived from a set of learnable global parameters :
where . These segment states are not independently learnable; segment-specific representations emerge through the attention updates [32], [33].
Cross-attention. At each layer , each segment state aggregates information exclusively from its corresponding token subset through cross-attention:
where provides the queries and provides the keys and values. This operation is asymmetric: the query side consists of a single vector of dimension , while the key-value side spans token vectors of dimension . The resulting attention matrix is , not square, and the query and key-value spaces differ in both size and dimensionality. All segments are processed in parallel by packing into the batch dimension, without altering the underlying computation. Cross-attention uses a single head at all layers, with per-layer head dimensions of .
Self-attention. After cross-attention, all segment states are stacked to form the segment-state matrix . Self-attention is applied across all segment states, enabling global information exchange:
repeated times per layer for . Self-attention uses multi-head attention with per-layer head counts of and per-layer head dimensions of .
Hierarchical segment-state compression. Across the four layers, the segment-state dimensionality decreases progressively as . At each layer transition, the segment representations are projected to the new dimensionality through a linear transformation when required. In the segmented-parallel configuration, the number of segment states remains fixed at , with one state associated with each token segment. After the final layer, the final segment states are averaged across segments and passed through a linear classification head. Both attention operations use pre-layer normalization and residual connections, with attention and feedforward dropout of 0.10 applied uniformly.
IV. EXPERIMENTAL EVALUATION & RESULTS
This section presents the experimental evaluation of MUPA S across unimodal and multimodal configurations. All experiments are evaluated under a binary classification setting. Validation performance is reported using macro-averaged accuracy, precision, and F1 score. Test performance is reported using macro-averaged accuracy. All models are trained for 190 epochs using AdamW with a learning rate of , weight decay of 0.05, batch size 4, and a cosine learning-rate schedule with 20 warmup epochs. Cross-entropy loss with label smoothing of 0.15 is used during training.

Fig. 1: Overview of the proposed unified perception framework. The video sequence is folded along the channel axis to form a tensor, while the ECG waveform is interpolated to a grid. The two modalities are concatenated into a input, flattened into 50176 spatial tokens, augmented with 26 Fourier positional features, and segmented into four token groups before being processed by the asymmetric attention model.
A. Data Collection
In this study, a multimodal stress dataset comprising 58 adults (24 men, 34 women) aged years was collected. The experimental protocol was designed to investigate facial and physiological responses under stress through four induction categories: social exposure, emotional recall, mental workload, and stressful stimuli. Each participant completed 11 tasks of 120 sec each: social exposure (neutral reference, baseline description, and interview), emotional recall (neutral reference and recall of a stressful event), mental workload (reading reference, Stroop Colour-Word Test, and Paced Auditory Serial Addition Test (PASAT)), and stressful stimuli (relaxing video, adventure video, and psychological pressure). The interview, recall, Stroop, PASAT, adventure video, and psychological pressure tasks were stress-inducing, while the reference and description tasks were neutral. The relaxing video served as a physiological recovery baseline and was grouped with the neutral conditions for binary classification. The stress induction was validated both physiologically and subjectively, as heart rate increased significantly during the stress-inducing tasks (), while the Self-Assessment Manikin ratings indicated elevated arousal and reduced valence in the stress phases compared with the neutral ones. It should be noted that the neutral tasks were administered at the beginning of each phase, and therefore the stress labels are partially aligned with task order. Moreover, the interview, recall, and PASAT tasks require the participants to speak, whereas the video stimuli do not. Consequently, part of the information learned from facial video may relate to speech-related facial activity, and
the present design does not allow these factors to be fully separated. A detailed description of the protocol is provided in [34]. The study received approval from the Research Ethics Committee (approval no. 155/12-09-2022). All participants provided informed consent. The dataset is available upon request for academic research purposes . Facial video and ECG were synchronously acquired during each task, with each sample comprising the paired Video–ECG recordings from the same experimental task. The facial video was recorded at 60 fps and subsampled to 30 fps with a resolution of pixels, while ECG was recorded continuously on a single channel at 1 kHz.
From the recorded video frames, the face region was detected by [35] and resized to before input to the model, providing a fixed spatial resolution for tokenization and matching the spatial domain used by the interpolated ECG representation in the unified fusion configuration. No additional ECG filtering is applied; each ECG waveform is mean-centered, standardized, min–max normalized to , and bilinearly interpolated to a representation. Binary classification is applied to distinguish neutral from stress conditions. Subjects are partitioned into training, validation, and testing sets at the subject level, ensuring no participant appears in more than one set. To avoid performance inflation due to subject-difficulty imbalance, a stratified split protocol is used. Leave-one-subject-out cross-validation is first conducted across all recorded modalities to estimate per-subject classification difficulty, providing a modality-independent ranking. Subjects
https://github.com/ggian/stress_dataset are ranked by the combined z-score of these difficulty estimates and assigned to four quartile-based groups. The final split comprises 38 training, 8 validation, and 12 testing subjects, corresponding to 414, 83, and 132 synchronized Video–ECG samples, respectively. The class distributions are 188/226, 37/46, and 60/72 neutral/stress samples for training, validation, and testing, respectively, with each set containing subjects from all four groups in proportion. Because the difficulty stratification is derived from preliminary LOSO estimates across the full cohort, we additionally evaluate the unified Video–ECG model using full LOSO across all 58 participants, providing a complementary subject-independent evaluation that does not depend on the fixed train/validation/test partition.
B. Unimodal Video
For video, temporal stride denotes uniform frame subsampling, where every -th frame is retained; thus, an original sequence of frames produces retained frames. Table II reports performance and computational cost across five temporal stride configurations. Test accuracy ranges from 60.56% at stride 5 to 69.44% at stride 15, with stride 15 achieving the highest test performance. The validation peak occurs at stride 20 (70.42%), showing that validation and test performance do not peak at the same temporal resolution. GFLOPs decrease substantially with stride, from 70.46 at stride 5 to 12.48 at stride 30, reflecting the reduction in the folded video-channel dimension as fewer frames are retained, while the spatial token count remains fixed at . Parameters also decrease slightly across configurations, from 6.39M to 5.82M, as the number of input channels scales with the number of frames and directly affects the size of the cross-attention projection matrices. The results show that test accuracy varies across temporal strides, with the best performance obtained at stride 15, indicating that retaining more frames does not necessarily improve performance. The stride analysis nevertheless shows that intermediate temporal sampling provides a favorable trade-off between predictive performance and computational cost. Notably, at stride 5 the model processes 720 frames as a single complete input tensor without any external windowing. This highlights that the architecture can natively handle full-length video inputs via its internal token segmentation mechanism.
C. Unimodal ECG
Table III reports performance and computational cost across seven stride configurations for the ECG modality. Test accuracy ranges from 51.81% to 53.33% across all configurations, remaining close to the chance level throughout. Stride 15 achieves the marginally highest test accuracy (53.33%), though the differences across strides are negligible. Unlike the video modality, both GFLOPs and parameter count are identical across all stride configurations at the reported precision (1.12 and 5.84M, respectively), as the 1D ECG token sequences are short and the computational differences across strides are negligible at two decimal places. Under the proposed unified representation, ECG-only performance remains close to chance,
indicating limited discriminative performance for the ECG modality within the present modeling configuration.
D. Multimodal Video & ECG
Two fusion strategies are evaluated and compared against the unimodal baselines reported in Sections IV-B and IV-C. The first is a feature-level approach, in which video and ECG are processed independently by two instances of the same model architecture. The final latent features from the two branches are pooled and concatenated, and the resulting joint representation is passed through a classification fusion head. The second is the unified approach described in Section III, where both modalities are combined at the input level through channel concatenation and processed by a single shared model. These two strategies are evaluated to compare the accuracy and efficiency of using separate model instances against a single unified model. For all multimodal configurations, the ECG stride is fixed at 1. Since the ECG waveform is projected onto a fixed spatial grid through bilinear interpolation before tokenization, the ECG input size remains fixed regardless of the original signal length. The stride notation in Table IV denotes the video stride and the ECG stride .
Table IV and Fig. 2(c) report the results for both fusion strategies across five video stride configurations. Feature-level fusion achieves test accuracies between 67.22% and 68.78%, with the highest test performance obtained at stride 20 (68.78%). Compared with the video-only results, feature-level fusion improves performance when we use low strides, with the largest gain at stride 5 where test accuracy increases from 60.56% to 68.61%, a gain of approximately 8 percentage points. However, feature-level fusion does not improve over the best video-only configuration (69.44% at stride 15), indicating that combining independently trained representations provides robustness at configurations where video-only performance is lower. The number of parameters for feature-level fusion ranges from 11.53M to 12.11M, reflecting the cost of maintaining two model instances.
The unified fusion strategy achieves test accuracies between 65.69% and 69.58%, with the highest test performance obtained at stride 15 (69.58%). The unified model uses approximately half as many parameters as feature-level fusion across all strides (5.82M to 6.39M), since it processes both modalities within a single shared backbone. GFLOPs for the unified approach remain nearly identical to the corresponding video-only configurations, since the ECG channel adds only one additional input channel after interpolation and contributes negligible computational overhead. Feature-level fusion adds approximately 0.91 GFLOPs over its video-only counterpart across all stride configurations. Overall, unified fusion achieves the highest test accuracy with the lowest parameter count among multimodal configurations, while feature-level fusion yields more consistent performance across stride configurations at approximately twice the parameter cost.
TABLE I: Subject-level split by difficulty group. Subjects are ranked by combined z-score and assigned to four quartile-based groups (Q1 = hardest, Q4 = easiest).
| Split | Difficulty Group | |||
|---|---|---|---|---|
| Q1 – Hard | Q2 – Med-Hard | Q3 – Med-Easy | Q4 – Easy | |
| Training (38) | P017, P018, P022, P026, P034, P035, P042, P045, P050, P056 | P001, P002, P003, P007, P012, P021, P033, P040, P048 | P004, P014, P016, P032, P036, P046, P047, P052, P053, P054 | P005, P010, P020, P028, P029, P037, P039, P041, P057 |
| Validation (8) | P038, P055 | P009, P023 | P006, P013 | P019, P030 |
| Testing (12) | P008, P025, P044 | P011, P024, P043 | P015, P031, P058 | P027, P051, P059 |
Q1: ; Q2: ; Q3: ; Q4: .
TABLE II: Performance and computational cost using the video modality.
| Input | Computational Cost | Validation | Testing | ||||
|---|---|---|---|---|---|---|---|
| Modality | Stride | Params (M) | GFLOPs | Accuracy | Precision | F1 | Accuracy |
| Video | 5 | 6.39 | 70.46 | 68.80 | 69.39 | 67.39 | 60.56 |
| Video | 10 | 6.05 | 35.67 | 66.39 | 66.20 | 66.14 | 63.75 |
| Video | 15 | 5.93 | 24.07 | 67.77 | 68.33 | 67.89 | 69.44 |
| Video | 20 | 5.87 | 18.27 | 70.42 | 71.86 | 68.45 | 65.97 |
| Video | 30 | 5.82 | 12.48 | 68.60 | 69.91 | 68.72 | 64.86 |
TABLE III: Performance and computational cost using the ECG modality.
| Input | Computational Cost | Validation | Testing | ||||
|---|---|---|---|---|---|---|---|
| Modality | Stride | Params (M) | GFLOPs | Accuracy | Precision | F1 | Accuracy |
| ECG | 1 | 5.84 | 1.12 | 50.00 | 27.71 | 35.66 | 51.81 |
| ECG | 2 | 5.84 | 1.12 | 54.32 | 68.85 | 45.81 | 52.50 |
| ECG | 5 | 5.84 | 1.12 | 55.93 | 66.83 | 49.70 | 52.50 |
| ECG | 10 | 5.84 | 1.12 | 55.67 | 70.89 | 48.21 | 52.64 |
| ECG | 15 | 5.84 | 1.12 | 53.23 | 61.90 | 45.07 | 53.33 |
| ECG | 20 | 5.84 | 1.12 | 55.67 | 70.89 | 48.21 | 52.64 |
| ECG | 30 | 5.84 | 1.12 | 54.58 | 64.66 | 47.43 | 52.78 |
Reported GFLOPs are identical across all stride configurations at the displayed precision. The 1D ECG token sequences are short relative to the video representation, and the GFLOP differences across strides are negligible at two decimal places.
TABLE IV: Performance and computational cost using the video and ECG modalities.
| Input | Computational Cost | Validation | Testing | |||||
|---|---|---|---|---|---|---|---|---|
| Modality | Stride | Fusion | Params (M) | GFLOPs | Accuracy | Precision | F1 | Accuracy |
| Video-ECG | 5-1 | feature-level | 12.11 | 71.37 | 69.36 | 69.27 | 68.67 | 68.61 |
| Video-ECG | 10-1 | feature-level | 11.76 | 36.58 | 70.48 | 70.74 | 70.57 | 67.22 |
| Video-ECG | 15-1 | feature-level | 11.65 | 24.99 | 71.27 | 71.02 | 70.98 | 68.33 |
| Video-ECG | 20-1 | feature-level | 11.59 | 19.19 | 67.74 | 67.54 | 67.39 | 68.78 |
| Video-ECG | 30-1 | feature-level | 11.53 | 13.39 | 68.57 | 68.41 | 68.45 | 67.22 |
| Video-ECG | 5-1 | unified | 6.39 | 70.49 | 66.13 | 66.00 | 66.02 | 65.69 |
| Video-ECG | 10-1 | unified | 6.05 | 35.70 | 66.92 | 66.84 | 66.26 | 66.94 |
| Video-ECG | 15-1 | unified | 5.93 | 24.11 | 65.83 | 65.83 | 65.03 | 69.58 |
| Video-ECG | 20-1 | unified | 5.87 | 18.31 | 69.33 | 71.01 | 67.16 | 68.47 |
| Video-ECG | 30-1 | unified | 5.82 | 12.51 | 67.98 | 69.25 | 66.02 | 68.47 |
The stride notation denotes the video stride and the ECG stride . ECG stride is fixed at 1 across all configurations, as the waveform is projected onto a fixed spatial grid through bilinear interpolation regardless of its original length.

(b) ECG
(c) Video-ECG Fusion: Feature-level vs. Unified
Fig. 2: Comparison of test accuracy and computational cost across unimodal and multimodal configurations. Panels (a) and (b) report video-only and ECG-only performance across stride values, together with the corresponding GFLOPs. Panel (c) compares feature-level and unified Video-ECG fusion across video strides, with ECG stride fixed to 1. Unified fusion achieves an overall test accuracy similar to feature-level fusion while using approximately half as many parameters.
E. Overall Analysis & Discussion
Across unimodal configurations, facial video reaches 69.44% test accuracy at stride 15, while ECG ranges from 51.81% to 53.33%; these results characterize performance within the proposed framework rather than intrinsic modality informativeness. Unified Video–ECG fusion achieves 69.58% test accuracy at stride 15, compared with 68.78% for feature-level fusion, while requiring approximately half the parameters. To complement the fixed hold-out protocol, unified Video–ECG fusion (video stride 15, ECG stride 1) was evaluated using LOSO across all 58 participants, achieving accuracy, precision, and F1 score, independently of the difficulty-based partition. Table V compares MUPA S with three approaches evaluated on the same 58-subject dataset. Under stratified hold-out, EDA-based representation fusion achieves 70.97% test accuracy, followed by MUPA S (69.58%) and [36] (69.44%); under LOSO, MUPA S reaches , close to the reported in [34]. Although the best unified and video-only configurations differ by only 0.14 percentage points, unified fusion improves over video alone by 5.13, 3.19, 0.14, 2.50, and 3.61 points at matched strides of 5, 10, 15, 20, and 30, respectively. While these results do not establish a statistically significant advantage over ECG, they suggest that its integration can preserve or improve performance across the evaluated configurations while providing complementary sensing redundancy for health-related assessment in clinical environments.
TABLE V: Comparison with previous approaches evaluated on the same 58-subject stress dataset.
| Study | Modality | Protocol | Accuracy |
|---|---|---|---|
| [37] | EDA | Hold-out | 70.97 |
| [36] | Video | Hold-out | 69.44 |
| MUPA S | Video-ECG | Hold-out | 69.58 |
| [34] | Video | LOSO | 80.04 10.86 |
| MUPA S | Video-ECG | LOSO | 80.30 11.63 |
Hold-out denotes the same stratified subject-level evaluation protocol. LOSO results are reported as mean accuracy standard deviation.
V. CONCLUSION
This paper presented MUPA S, a multimodal unified perception framework for automatic stress assessment combining facial video and ECG signals. The framework maps both modalities into a shared representation and processes them through asymmetric attention, enabling heterogeneous inputs to be handled within a single architecture without modality-specific components. Experiments on a newly collected 58-subject stress dataset show that facial video reaches 69.44% test accuracy, while unified Video–ECG fusion achieves the highest observed test accuracy of 69.58% with approximately half the parameters of feature-level fusion. Complementary LOSO evaluation achieves accuracy, precision, and F1 score. We emphasize that the present study is based on a single controlled dataset, and in real-world settings this could be limited. We suggest that future work should evaluate additional datasets, either stress-based or other internal human states [38] that can influence stress sensation or manifestation, while exploring richer physiological representations [39] and complementary modalities [40] to improve generalization and sensing reliability in health-related applications [41], such as diagnostic systems or companion robots [42] in healthcare settings.
ACKNOWLEDGMENTS
The authors used large language model (LLM)-based tools for language editing and improvement. All scientific content, results, and conclusions are solely the work of the authors.
REFERENCES
[1] D. S. Goldstein, “Stress and the autonomic nervous system,” Autonomic Neuroscience, vol. 247, p. 103096, 2023.
[2] S. Cohen, T. Kamarck, and R. Mermelstein, “A global measure of perceived stress,” Journal of Health and Social Behavior, vol. 24, no. 4, pp. 385–396, 1983.
[3] S. Shiffman, A. A. Stone, and M. R. Hufford, “Ecological momentary assessment,” Annual Review of Clinical Psychology, vol. 4, pp. 1–32, 2008.
[4] E. F. Canaletti, P. Lun, L. D. Stutzman, M. Chan, and F. Cheung, “Rising tide of stress: Global trends and structural predictors over 18 years,” Wellbeing, Space and Society, vol. 10, p. 100319, 2026.
[5] H. Sultan-Taieb, T. Villeneuve, J.-F. Chastang, and I. Niedhammer, “Burden of cardiovascular diseases and depression attributable to psychosocial work exposures in 28 European countries,” European Journal of Public Health, vol. 32, no. 4, pp. 586–592, 2022.
[6] M. Hosseini, R. Gottumukkala, R. Bhupatiraju, A. Maida, and H. Chu, "Wearable-based stress detection for real-world data: Perspective on challenges and recommendations," 2026, JMIR Preprints, Preprint ID: 93741.
[7] P. Neigel, A. Vargo, B. Tag, and K. Kise, “Unobtrusive stress detection using wearables: application and challenges in a university setting,” Frontiers in Computer Science, vol. 7, p. 1575404, 2025.
[8] G. Giannakakis, D. Grigoriadis, K. Giannakaki, O. Simantiraki, A. Roniotis, and M. Tsiknakis, “Review on psychological stress detection using biosignals,” IEEE Transactions on Affective Computing, vol. 13, no. 1, pp. 440–460, 2022.
[9] L. Gonzalez-Carabarin, E. A. Castellanos-Alvarado, P. Castro-Garcia, and M. A. Garcia-Ramirez, “Machine learning for personalised stress detection: inter-individual variability of EEG-ECG markers for acute-stress response,” Computer Methods and Programs in Biomedicine, vol. 209, p. 106314, 2021.
[10] G. Giannakakis, M. Pediaditis, D. Manousos, E. Kazantzaki, F. Chiarugi, P. G. Simos, K. Marias, and M. Tsiknakis, “Stress and anxiety detection using facial cues from videos,” Biomedical Signal Processing and Control, vol. 31, pp. 89–101, 2017.
[11] G. Giannakakis, M. R. Koujan, A. Roussos, and K. Marias, “Automatic stress detection evaluating models of facial action units,” in 2020 15th IEEE International Conference on Automatic Face and Gesture Recognition (FG 2020), 2020, pp. 728–733.
[12] T. Kassiotis, S. Gkikas, N. Smyrnis, and G. Giannakakis, “Explainable graph attention network for stress recognition (StressGAT) via differential action units,” in 2026 14th International Conference on Affective Computing and Intelligent Interaction (ACII). IEEE, 2026.
[13] M. Kyrou, I. Kompatsiaris, and P. C. Petronakakis, “Deep learning approaches for stress detection: a survey,” IEEE Transactions on Affective Computing, vol. 16, no. 2, pp. 499–517, 2025.
[14] J. Zhang, H. Yin, J. Zhang, G. Yang, J. Qin, and L. He, “Real-time mental stress detection using multimodality expressions with a deep learning framework,” Frontiers in Neuroscience, vol. 16, p. 947168, 2022.
[15] P. Valergaki, V. C. Nicodemou, I. Oikonomidis, A. Argyros, and A. Roussos, “Combining facial videos and biosignals for stress estimation during driving,” 2026.
[16] H. Zhang, L. Feng, N. Li, Z. Jin, and L. Cao, “Video-based stress detection through deep learning,” Sensors, vol. 20, no. 19, p. 5552, 2020.
[17] T. Jeon, H. B. Bae, Y. Lee, S. Jang, and S. Lee, “Deep-learning-based stress recognition with spatial-temporal facial information,” Sensors, vol. 21, no. 22, p. 7498, 2021.
[18] G. Giannakakis, A. Roussos, C. Andreou, S. Borgwardt, and A. I. Korda, “Stress recognition identifying relevant facial action units through explainable artificial intelligence and machine learning,” Computer Methods and Programs in Biomedicine, vol. 259, p. 108507, 2025.
[19] G. Giannakakis, K. Marias, and M. Tsiknakis, “A stress recognition system using HRV parameters and machine learning techniques,” in 2019 8th International Conference on Affective Computing and Intelligent Interaction Workshops and Demos (ACIIW), 2019, pp. 269–272.
[20] R. Zhou, C. Wang, P. Zhang, X. Chen, L. Du, P. Wang, Z. Zhao, M. Du, and Z. Fang, “ECG-based biometric under different psychological stress states,” Computer Methods and Programs in Biomedicine, vol. 202, p. 106005, 2021.
[21] A. Alkurdi, M. He, J. Cerna, J. Clore, R. Sowers, E. T. Hsiao-Wecksler, and M. E. Hernandez, “Extending anxiety detection from multimodal wearables in controlled conditions to real-world environments,” Sensors, vol. 25, no. 4, p. 1241, 2025.
[22] L. Zhao, X. Niu, L. Wang, J. Niu, X. Zhu, and Z. Dai, “Stress detection via multimodal multitemporal-scale fusion: a hybrid of deep learning and handcrafted feature approach,” IEEE Sensors Journal, vol. 23, no. 22, pp. 27817–27827, 2023.
[23] M. Naegelin, R. P. Weibel, J. I. Kerr, V. R. Schinazi, R. La Marca, F. von Wangenheim, C. Hoelscher, and A. Ferrario, “An interpretable machine learning approach to multimodal stress detection in a simulated office environment,” Journal of Biomedical Informatics, vol. 139, p. 104299, 2023.
[24] P. Schmidt, A. Reiss, R. Duerichen, C. Marberger, and K. Van Laerhoven, “Introducing WESAD, a multimodal dataset for wearable stress and affect detection,” in Proceedings of the 20th ACM International Conference on Multimodal Interaction (ICMI), 2018, pp. 400–408.
[25] M. Gjoreski, M. Lüstrek, M. Gams, and H. Gjoreski, “Monitoring stress with a wrist device using context,” Journal of Biomedical Informatics, vol. 73, pp. 159–170, 2017.
[26] M. Dzieżyc, M. Gjoreski, P. Kazienko, S. Saganowski, and M. Gams, "Can we ditch feature engineering? End-to-end deep learning for affect recognition from physiological sensor data," Sensors, vol. 20, no. 22, p. 6535, 2020.
[27] P. Sarkar and A. Etemad, “Self-supervised ECG representation learning for emotion recognition,” IEEE Transactions on Affective Computing, vol. 13, no. 3, pp. 1541–1554, 2022.
[28] B. Behinaein, A. Bhatti, D. Rodenburg, P. Hungler, and A. Etemad, “A transformer architecture for stress detection from ECG,” in Proceedings of the 2021 ACM International Symposium on Wearable Computers (ISWC), 2021, pp. 132–134.
[29] Y. Wu, M. Daoudi, and A. Amad, “Transformer-based self-supervised multimodal representation learning for wearable emotion recognition,” IEEE Transactions on Affective Computing, vol. 15, 2024.
[30] S. Gkikas, C. A. Cruz, V. Becchetti, M. U. Khan, A. Giuseppi, and R. Fernandez Rojas, “A unified tokenization framework for pain recognition using heterogeneous 3d modalities,” ser. ICMI '26. New York, NY, USA: Association for Computing Machinery, 2026, p. 1234–1243.
[31] S. Gkikas, C. Arzate Cruz, C. Joseph, G. Giannakakis, and R. Fernandez Rojas, “Towards a unified modality-agnostic multimodal framework for cognitive workload assessment,” in 2026 14th International Conference on Affective Computing and Intelligent Interaction (ACII). Puebla, Mexico: IEEE, 2026.
[32] S. Gkikas, Y. Guo, G. Li, R. F. Rojas, G. Giannakakis, and R. Gomez, “A multi-scale temporal framework with dynamic fusion for eeg-based emotion recognition,” in 2026 9th International Conference on Pattern Recognition and Artificial Intelligence (PRAI). IEEE, 2026.
[33] S. Gkikas, E. Nichols, C. A. Cruz, and R. Gomez, “MUPA2E: Multimodal unified perception with asymmetric attention for emotion assessment,” in 11th Workshop and Competition on Affective and Behavior Analysis in-the-Wild (ABAW), European Conference on Computer Vision (ECCV). Springer, 2026.
[34] S. Gkikas, C. A. Cruz, E. Nichols, G. Giannakakis, and R. Gomez, “UNWIND: Any-length facial video for stress detection without temporal windowing,” in 11th Workshop and Competition on Affective and Behavior Analysis in-the-Wild (ABAW), European Conference on Computer Vision (ECCV). Springer, 2026.
[35] V. Bazarevsky, Y. Kartynnik, A. Vakunov, K. Raveendran, and M. Grundmann, “BlazeFace: Sub-millisecond neural face detection on mobile GPUs,” arXiv preprint arXiv:1907.05047, 2019.
[36] S. Gkikas, T. Kassiotis, Y. Guo, G. Li, and G. Giannakakis, “FUSE: Frame-unified stress estimation from facial video,” in 2026 9th International Conference on Pattern Recognition and Artificial Intelligence (PRAI). IEEE, 2026.
[37] S. Gkikas, T. Kassiotis, Y. Guo, G. Li, E. Nichols, H. Asadi, N. Smyrnis, and G. Giannakakis, “Beyond the raw waveform: Fusing visual representations of eda for stress detection,” in 2026 9th International Conference on Pattern Recognition and Artificial Intelligence (PRAI). IEEE, 2026.
[38] S. Gkikas, Y. Fang, C. A. Cruz, M. U. Khan, and R. F. Rojas, “ReFace: Reorganizing Facial Spatiotemporal Representations for Improved Pain Assessment,” in 2026 14th International Conference on Affective Computing and Intelligent Interaction (ACII). IEEE, 2026.
[39] I. Kyprakis, S. Gkikas, E. Nichols, Y. Fang, and M. Tsiknakis, “An Exploratory Analysis of Pain Localization via Explainable Computational Modeling,” in 2026 14th International Conference on Affective Computing and Intelligent Interaction (ACII). IEEE, 2026.
[40] C. A. Cruz, S. Gkikas, and H. Asadi, “Efficient and Interpretable Body-Based Emotion Recognition with Lightweight Temporal Convolutional Networks,” in 2026 14th International Conference on Affective Computing and Intelligent Interaction (ACII). IEEE, 2026.
[41] S. Gkikas, C. A. Cruz, Y. Fang, L. Cao, M. U. Khan, T. Kassiotis, G. Giannakakis, R. F. Rojas, and R. Gomez, “A lightweight transformer for pain recognition from brain activity,” in 2026 7th International Conference in Electronic Engineering & Information Technology (EEITE), 2026, pp. 1–7.
[42] E. C. Montiel-Vazquez, C. A. Cruz, S. Gkikas, T. Kassiotis, G. Giannakakis, and R. Gomez, “Efficient emotion-aware iconic gesture prediction for robot co-speech,” in 2026 7th International Conference in Electronic Engineering & Information Technology (EEITE), 2026, pp. 1–5.