Manuscript Offprint
arXiv:2611.02027Uncertainty-Aware 3D Position Reconstruction in CZT Drift-Strip Detectors
Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.
Alejandro Valverde Mahou*
Michal Kossakowski†
Selina R. H. Owe†
Rikke S. Klausen†
Irfan Kuvvetli†
Christian A. Naesseth‡
Søren Hauberg*
Abstract
Accurate three-dimensional interaction-position reconstruction is important for CZT drift-strip detectors, but conventional methods can suffer from degraded performance in challenging detector regions, while learned models provide limited information about prediction reliability. We investigate two uncertainty-aware approaches: deep ensembles of point-estimation networks and simulation-based inference (SBI), which estimates a posterior distribution over interaction position. Both approaches are trained on physics-based simulations and evaluated on both synthetic and experimental data. On synthetic data, uncertainty from both methods correlates with positioning error, with SBI showing a substantially stronger relationship. On experimental measurements, the deep ensemble achieves improved z-position resolution, while SBI provides more informative uncertainty estimates that highlight regions of reduced positional information and discrepancies between simulation and the physical detector. These results demonstrate the complementary strengths of ensemble-based reconstruction and posterior inference for uncertainty-aware detector position reconstruction.
1 Introduction
High-energy astrophysics and medical imaging rely on inferring particle interaction properties from detector signals, an inherently ill-posed inverse problem. In the megaelectronvolt (MeV) range, this is particularly challenging due to complex interaction physics, charge transport, and multi-channel signal formation. 3D Cadmium Zinc Telluride Drift Strip Detector (3D CZT DSD) detectors are promising for MeV gamma-ray detection, with applications ranging from space instrumentation to medical imaging [Van Pamelen and Budtz-Jørgensen, 1998b,a, Owe et al., 2022]. In particular, 3D drift-strip architectures provide fine-grained interaction-position information [Kuvvetli and Budtz-Jørgensen, 2005, Kuvvetli et al., 2024].
Position reconstruction is conventionally performed using Pulse-Shape Analysis (PSA), which can achieve submillimeter resolution [Budtz-Jørgensen and Kuvvetli, 2017]. However, reconstruction quality can deteriorate near detector boundaries, producing dead zones and regions of degraded resolution. Deep learning alternatives map from detector waveforms to interaction position. Such models require simulated training data and can achieve accurate point estimates, but provide no direct measure of prediction reliability. Furthermore, discrepancies between the physics-based simulator and the real detector, such as the point-charge approximation of the charge cloud used here, can introduce a sim-to-real gap that deterministic regression cannot quantify [Owe et al., 2026].
*DTU Compute, Technical University of Denmark, Kgs. Lyngby, Denmark.
†DTU Space, Technical University of Denmark, Kgs. Lyngby, Denmark.
‡Informatics Institute, University of Amsterdam, Amsterdam, Netherlands.
40th Conference on Neural Information Processing Systems (NeurIPS 2026). Workshop: Sim2Science.
Uncertainty-aware methods offer a complementary approach. Ensembles quantify variability across independently trained predictors, while Simulation-Based Inference (SBI) estimates a posterior distribution over interaction position conditioned on the measured signal and simulation model [Cranmer et al., 2020]. We compare these approaches for 3D CZT DSD interaction-position reconstruction, examining how their uncertainty estimates relate to localization error and known detector anomalies. We further compare their reconstruction resolution with conventional PSA on experimental data and investigate whether SBI uncertainty reveals discrepancies between simulation and the physical detector.
Interaction positions can be reconstructed using conventional pulse-shape analysis. We use the algorithm of Budtz-Jørgensen and Kuvvetli [2017], with the implementation applied in Hauptmann et al. [2024], as the conventional baseline for comparison. The method combines features of the anode, drift-strip, and cathode signals to estimate the three spatial coordinates.
Training data for the neural-network and SBI approaches are generated using the Advanced Theoretical Detector Model (ATDM) [Owe et al., 2026], a physics-based simulation framework that combines electrostatic and Charge Induction Efficiency (CIE) modelling with signal generation and electronics simulation. Because full-volume CIE simulation for all 69 channels is computationally prohibitive, the detector is represented by a set of precomputed sub-volumes covering the different electrode regions. These sub-volumes are translated across the detector geometry to generate pulse shapes for arbitrary interaction positions. The simulated signals are subsequently passed through the electronics model and converted from CIE to ADC counts. See Appendix A for details.
The resulting synthetic events have the same multi-channel waveform format as the experimental data, with each event associated with a known three-dimensional interaction position. This enables supervised training of the neural networks and simulation-based inference.
Experimental validation (hereafter, real data) used the same 3D CZT DSD module modelled in the ATDM (Detector 2, [Hauptmann et al., 2024, Owe et al., 2026]). The detector was irradiated with a source at 662 keV, matching the simulation energy. Three geometries were used: 0.2 mm slit beams along and to quantify position resolution via the Full-Width-at-Half-Maximum (FWHM), a diagonal slit beam to assess localized reconstruction artifacts, and full illumination to assess global reconstruction behavior.
Events were filtered to isolate single-site interactions, and all output channels were baseline-normalized for consistency. No electrode-response calibration, such as ADC-to-keV conversion or non-linearity correction, was applied, preserving the raw pulse-shapes for the sim-to-real comparison.
3 Methods
We compare two approaches to uncertainty-aware interaction-position reconstruction: a deep ensemble of point-estimation networks and SBI. Both approaches share the same waveform encoder, providing a common signal representation for a direct comparison.
Model architecture. Each event consists of 69 detector waveforms with 500 samples each. A shared one-dimensional convolutional encoder processes each waveform independently and maps it to a 16-dimensional embedding. The 69 embeddings are concatenated and projected to a 32-dimensional latent representation. The resulting representation is passed to either an ensemble member or an SBI inference head. Full architectural details are given in Appendix B.
The encoder is pretrained as a denoising autoencoder: Gaussian noise is added to the input waveforms, while the reconstruction target is the corresponding clean waveform. This encourages the latent representation to retain relevant signal information while being robust to measurement noise. After pretraining, the decoder is discarded and the encoder is used for both approaches.
Deep Ensemble. Each ensemble member maps an input waveform s to a three-dimensional interaction position . We train independently initialized models with different data shuffling. The ensemble prediction is the mean , while epistemic uncertainty is estimated from the sample covariance .
Simulation-based inference. For SBI, we model the conditional position distribution as a diagonal Gaussian, . The inference head predicts and is trained on simulated signal-position pairs using the Gaussian negative log-likelihood . The posterior mean provides the position estimate, while represents coordinate-wise uncertainty conditioned on the assumed simulation model.
The training data are generated using the ATDM [Owe et al., 2026]. Interaction positions are sampled uniformly throughout the detector volume, and the resulting signals are processed through the simulated readout electronics. Events are filtered by requiring an energy deposition of at least 400 Analog-to-Digital Converter (ADC) channels in one anode signal. During training, Gaussian noise is added to the simulated waveforms, with the standard deviation estimated from electronic noise in the experimental data. Training details are provided in Appendix B.
Evaluation. Both approaches are first evaluated on the same synthetic test set using positioning error and its spatial distribution across the detector volume. Their uncertainty estimates are additionally compared with the observed positioning error. The trained models are then applied to real detector data, where positioning resolution is evaluated using slit-beam measurements in the and directions. Diagonal slit-beam and full-illumination measurements provide qualitative assessments of localized and global reconstruction behavior, respectively.

Figure 1: Relationship between predicted uncertainty and positioning error on the synthetic test set for the deep ensemble and SBI. Each point represents an event; the dashed line indicates the 1:1 relationship, while denotes the Pearson correlation coefficient.
4 Results
Synthetic-data uncertainty. Both methods were evaluated on the synthetic test set, where the true interaction position is known. Fig. 2 shows the predicted uncertainty, while Fig. 1 shows the relationship with the corresponding positioning error. Both methods exhibit a positive correlation between predicted uncertainty and positioning error, indicating that uncertainty relates to reliability. This relationship is substantially stronger and more clearly structured for SBI. In particular, the SBI uncertainty increases toward the lower boundary, where the available signal information becomes progressively less informative, and position reconstruction is more ambiguous. The ensemble uncertainty shows a considerably weaker spatial structure.
These results demonstrate that both approaches provide useful information about reconstruction reliability, but capture different aspects of uncertainty. The stronger correspondence between SBI uncertainty and positioning error suggests that its posterior uncertainty more directly reflects the information content of the observed waveform.
Position resolution. Position resolution is measured using slit-beam illumination, for which the reconstructed interaction positions are expected to follow a Gaussian-like distribution. We quantify the resolution using the FWHM of the resulting distribution.
In the -dimension, all three methods achieve comparable resolution (FWHM = 0.58, 0.56, and 0.57 mm for PSA, ensemble, and SBI, respectively), reflecting the strong constraint provided by the drift-strip geometry, as seen in Figure 3 a. The -dimension, which relies on more subtle pulse-shape information, shows a larger separation: the ensemble achieves the best resolution (0.62 mm), improving substantially over PSA (1.01 mm), while SBI achieves 0.88 mm (Figure 3 b). The 2D distributions show that reconstruction becomes less accurate near the anodes, consistent with the reduced signal information in this region.

Figure 2: Uncertainty estimates for synthetic-data events under full illumination across the anode and cathode dimensions. Left: Uncertainty across anodes in the x-y plane; Right: Uncertainty across cathodes in the z-y plane. Top: ensembles; Bottom: SBI. The corresponding full-range uncertainty estimates are shown in Figure 6 and 7.

Figure 3: Reconstruction resolution for the (a) x- and (b) z-dimensions using conventional pulse-shape analysis, an ensemble of point-estimate models, and SBI. Left: pulse-shape analysis; Center: ensemble; Right: SBI. The 1D histograms show the distribution of reconstructed positions, while the 2D histograms show the same reconstructions against the depth of illumination (y-position).
Transfer of uncertainty to real data. The spatial structure observed on synthetic data also appears in the real measurements. Figure 4 shows uncertainty estimates for a full-illumination measurement. For SBI, uncertainty increases toward low y in both x and z, consistent with the reduced signal information in this region. The ensemble uncertainty shows substantially less spatial structure, with high- and low-uncertainty events distributed more uniformly across the detector.
This difference is consistent with the quantities represented by the two methods. The ensemble measures disagreement between independently trained point estimators and therefore primarily reflects epistemic uncertainty, whereas the SBI posterior represents uncertainty in the inferred position conditioned on the observed waveform under the assumed simulation model. The agreement between the synthetic and real-data patterns suggests that the SBI uncertainty captures a physically meaningful limitation of the reconstruction.
Robustness to detector anomalies. The diagonal slit-beam measurement crosses both Faulty C12 and Dead C4, providing a test of detector anomalies that are absent or incompletely represented in the training data. Figure 5 shows that PSA maintains a relatively tight reconstruction through both defect regions, while the ensemble exhibits a modest increase in spread. SBI shows the strongest increase in uncertainty around the defects, accompanied by increased reconstruction spread.
This response is particularly notable for C4, whose detector behavior is not fully represented in the ATDM. The localized increase in SBI uncertainty therefore provides an indication of a discrepancy between the simulated and experimental detector response. While this reduces reconstruction accuracy in the affected region, the corresponding increase in posterior uncertainty provides information about when the model's prediction should be treated with caution.

Figure 4: Uncertainty estimates for real-data events under full illumination across the anode (x-y) and cathode (z-y) dimensions. Left: Uncertainty across anodes in the x-y plane; Right: Uncertainty across cathodes in the z-y plane. Top: Ensemble; Bottom: SBI. Figure 8 and 9

Figure 5: Diagonal slit-beam reconstruction for conventional pulse-shape analysis (first from left), ensemble and its uncertainty (second and third), and SBI and its uncertainty (fourth and fifth), viewed in the x-z plane. The beam crosses both anode and cathode strips, including faulty cathode C12 and dead cathode C4.
5 Discussion and Conclusion
The results demonstrate that uncertainty can provide information beyond point-estimate accuracy. On synthetic data, uncertainty from both approaches correlates with positioning error, with the SBI posterior showing the stronger relationship. This behavior transfers to real measurements, where the SBI uncertainty increases in regions known to provide less positional information and responds to detector anomalies that are absent or incompletely represented in the ATDM. In particular, the increase around the defective C4 electrode suggests that posterior uncertainty can act as a diagnostic signal for discrepancies between the simulated and physical detector.
The current SBI model is nevertheless limited to a single Gaussian posterior with diagonal covariance. This prevents it from representing correlations between spatial coordinates or multimodal position distributions, which may become important for ambiguous signals and multiple interactions. Future work will therefore investigate full covariance modelling and more expressive posterior parameterizations, including deep ensembles of posterior estimators [Lakshminarayanan et al., 2017]. For events containing multiple interactions, mixtures of Gaussians could provide a natural extension by representing multiple plausible interaction positions. More flexible neural density estimators, such as normalizing flows, could further capture non-Gaussian and multimodal posteriors without prescribing their form.
Overall, the ensemble provides improved point-estimate resolution, particularly in the z-dimension, while SBI provides richer information about reconstruction reliability and exposes discrepancies between simulation and experiment. Rather than viewing these approaches as competing solutions, their complementary strengths motivate combining accurate ensemble-based reconstruction with expressive posterior modelling. Such uncertainty-aware reconstruction could provide both improved localization and a practical feedback signal for refining the ATDM and extending the method to multiple energies and interaction types.
Acknowledgments
This work was supported by the i-RASE project, funded by the European Union under the Horizon Europe EIC Pathfinder Open programme (Grant Agreement No. 101130550).
References
James Bradbury, Roy Frostig, Peter Hawkins, Matthew James Johnson, Yash Katariya, Chris Leary, Dougal Maclaurin, George Necula, Adam Paszke, Jake VanderPlas, Skye Wanderman-Milne, and Qiao Zhang. JAX: composable transformations of Python+NumPy programs, 2018. URL http://github.com/jax-ml/jax.
Carl Budtz-Jørgensen and Irfan Kuvvetli. New position algorithms for the 3-d czt drift detector. IEEE Transactions on Nuclear Science, 64(6):1611–1618, 2017.
Kyle Cranmer, Johann Brehmer, and Gilles Louppe. The frontier of simulation-based inference. Proceedings of the National Academy of Sciences, 117(48):30055–30062, May 2020. ISSN 1091-6490. doi: 10.1073/pnas.1912789117. URL http://dx.doi.org/10.1073/pnas.1912789117.
Benjamin N. Hauptmann, Selina R. H. Owe, Irfan Kuvvetli, Denis Tcherniak, Carl Budtz-Jørgensen, Ian Baistow, Brian Harris, Alexander Cherlin, and Ben Cantwell. Performance evaluation of new large area 3D CdZnTe drift strip detectors. In Jan-Willem A. den Herder, Shouleh Nikzad, and Kazuhiro Nakazawa, editors, Space Telescopes and Instrumentation 2024: Ultraviolet to Gamma Ray, volume 13093, page 130931D. International Society for Optics and Photonics, SPIE, 2024. doi: 10.1117/12.3015044. URL https://doi.org/10.1117/12.3015044.
Patrick Kidger and Cristian Garcia. Equinox: neural networks in JAX via callable PyTrees and filtered transformations. Differentiable Programming workshop at Neural Information Processing Systems 2021, 2021.
M Kolstein, G Ariño, M Chmeissani, and G De Lorenzo. Simulation of charge transport in pixelated CdTe. Journal of Instrumentation, 9(12):C12027, December 2014. ISSN 1748-0221. doi: 10.1088/1748-0221/9/12/C12027. URL https://doi.org/10.1088/1748-0221/9/12/C12027.
I Kuvvetli, SRH Owe, and C Budtz-Jørgensen. Advancements in cdznte detectors with the drift strip method. CdTe and CdZnTe Materials: Material Properties and Applications, pages 51–70, 2024.
Irfan Kuvvetli and Carl Budtz-Jorgensen. Pixelated cdznte drift detectors. IEEE transactions on nuclear science, 52(5):1975–1981, 2005.
Balaji Lakshminarayanan, Alexander Pritzel, and Charles Blundell. Simple and Scalable Predictive Uncertainty Estimation using Deep Ensembles. In I. Guyon, U. Von Luxburg, S. Bengio, H. Wallach, R. Fergus, S. Vishwanathan, and R. Garnett, editors, Advances in Neural Information Processing Systems, volume 30. Curran Associates, Inc., 2017. URL https://proceedings.neurips.cc/paper_files/paper/2017/file/9ef2ed4b7fd2c810847ffa5fa85bce38-Paper.pdf.
S. R. H. Owe, M. Kossakowski, R. S. Klausen, A. Cherlin, A. Valverde Mahou, G. Arvanitidis, S. Hauberg, D. Tcherniak, C. Budtz-Jørgensen, and I. Kuvvetli. Detector simulation for neural network position reconstruction in the i-RASE system. In Shouleh Nikzad, Kazuhiro Nakazawa, and Marco Feroci, editors, Space Telescopes and Instrumentation 2026: Ultraviolet to Gamma Ray, volume 14146, page 141463U. International Society for Optics and Photonics, SPIE, 2026. doi: 10.1117/12.3102775. URL https://doi.org/10.1117/12.3102775.
SRH Owe, I Kuvvetli, A Cherlin, B Harris, H Tomita, I Baistow, D Tcherniak, and C Budtz-Jørgensen. Evaluation of czt drift strip detectors for use in 3-d molecular breast imaging. IEEE Transactions on Radiation and Plasma Medical Sciences, 7(2):113–123, 2022.
T. H. Prettyman. Theoretical framework for mapping pulse shapes in semiconductor radiation detectors. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 428(1):72–80, June 1999. ISSN 0168-9002. doi: 10.1016/S0168-9002(98)01582-4. URL https://www.sciencedirect.com/science/article/pii/S0168900298015824.
MAJ Van Pamelen and Carl Budtz-Jørgensen. Cdznte drift detector with correction for hole trapping. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 411(1):197–200, 1998a.
MAJ Van Pamelen and Carl Budtz-Jørgensen. Novel electrode geometry to improve performance of cdznte detectors. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 403(2-3):390–398, 1998b.
A Data generation with the Advanced Theoretical Detector Model
Training data are generated using the Advanced Theoretical Detector Model (ATDM) [Owe et al., 2026], a physics-based simulation framework that models the detector response from an interaction position to the digitized detector waveform. The underlying charge-transport and signal-induction formulation follows the approach described in Prettyman [1999], Kolstein et al. [2014].
The simulation can be divided into two main stages. First, the charge transport and charge induction in the detector are simulated to obtain the time-dependent charge-induction efficiency (CIE). Second, the resulting CIE signals are passed through a model of the experimental readout electronics to obtain waveforms in ADC units.
Charge transport and charge induction The charge-transport and signal-induction model is based on the electrostatic field equations and the Shockley–Ramo theorem. The electrostatic potential is obtained by solving the Laplace equation within the detector geometry,
with boundary conditions determined by the applied electrode voltages.
The induced signal on each electrode is described according to the Shockley–Ramo theorem through a corresponding weighting potential . The weighting potential is obtained by solving the Laplace equation for electrode with that electrode set to unit potential and the remaining electrodes set to zero. In short, determines how charge carriers move through the detector, while determines how their motion is observed by each electrode.
For a given interaction, the resulting carrier transport and charge induction are described by
and
where and denote the electron and hole concentrations, respectively, and are the corresponding carrier mobilities, and and are their diffusion coefficients. The quantities and describe the carrier lifetimes. The electrostatic potential is denoted by , while is the weighting potential associated with electrode . Thus, the equations account for the effects of drift, diffusion, carrier trapping, and charge induction on the electrode.
Solving these equations for the three spatial coordinates and time produces the time-dependent charge-induction efficiency,
which describes the induced response on electrode for an interaction at a given position.
The resulting four-dimensional solutions are used as look-up tables during data generation. Since calculating the CIE over the entire detector volume for all 69 electrodes is computationally expensive, the detector volume is instead decomposed into a set of representative sub-volumes. These include anode-, drift-, and cathode-centered configurations, with central and edge variants, as well as a configuration accounting for an inactive cathode in the detector used for experimental validation. The resulting CIE solutions are translated across the detector geometry, allowing the response at arbitrary interaction positions to be obtained efficiently without repeatedly solving the underlying PDEs.
For an interaction depositing an energy , the normalized CIE is converted to charge according to
where is the elementary charge and is the mean ionization energy of the detector material. For the simulations used in this work, keV
Electronics simulation The induced charge is subsequently converted into a digitized waveform through a model of the experimental readout electronics. The main stages are the charge-sensitive preamplifier, amplification, analog-to-digital conversion, and trigger alignment.
The charge-sensitive preamplifier is modeled as a temporal filtering operation,
where represents the response of the charge-sensitive preamplifier and accounts for the channel-dependent input capacitance and preamplifier response.
The resulting analog signal is amplified and converted to ADC units. For an ADC with bits and voltage range , the voltage corresponding to one ADC count is
The digitized signal is then given by
where is the amplifier gain. Finally, the simulated waveforms are aligned according to the trigger convention of the experimental acquisition system.
The resulting output consists of 69 channels of digitized waveforms with the same format as the experimental data. The complete simulation pipeline can therefore be summarized as
These simulated signal-position pairs are subsequently used for training and evaluating the neural-network and SBI approaches.
B Detailed model architecture
The complete architecture is composed of a waveform encoder, a feature encoder, and task-specific prediction heads. The main architecture uses a base channel width of 4, a waveform embedding dimension of 16, and a final latent dimension of 32.
Waveform encoder. Each of the 69 input channels is processed independently by the same one-dimensional convolutional encoder. Given a waveform , an initial convolution with kernel size 7 maps the single input channel to 4 feature channels. This is followed by a residual block consisting of two convolutional layers with kernel size 3. The number of channels is then increased to 8 while downsampling the temporal dimension by a factor of two. A second residual block is applied, followed by another convolution that increases the number of channels to 16 and reduces the temporal dimension from 250 to 125. A final residual block is followed by a fully connected layer mapping the resulting representation to a 16-dimensional waveform embedding.
The residual blocks consist of two convolutional layers with kernel size 3 and constant channel dimension. GELU activations are applied after the first convolution and after the residual addition.
Feature encoder. The same waveform encoder is applied independently to all 69 channels. The resulting 69 embeddings, each of dimension 16, are concatenated to form a -dimensional representation. A fully connected layer then maps this representation to the final 32-dimensional latent vector .
Autoencoder pretraining. During pretraining, the latent representation is passed to a symmetric feature decoder. A fully connected layer first maps the 32-dimensional latent vector to 69 waveform embeddings of dimension 16. Each embedding is then decoded independently by a shared one-dimensional convolutional decoder. The decoder first maps the embedding to a representation and progressively increases the temporal resolution from 125 to 250 and from 250 to 500. The channel dimension is simultaneously reduced from 16 to 8, then to 4, and finally to a single output channel. Linear interpolation is used for temporal upsampling, followed by convolutional and residual blocks.
The autoencoder is trained to reconstruct the original normalized signal. During training, the input to the encoder is augmented with additive channel-dependent noise, while the reconstruction target is the corresponding unaugmented signal. This results in a denoising-style pretraining objective, encouraging the latent representation to capture the underlying waveform structure rather than the particular realization of the noise.
Position-reconstruction head. Following autoencoder pretraining, the decoder is removed and the pretrained feature encoder is used as the representation network. A three-layer MLP maps the 32-dimensional latent representation to the three spatial coordinates. The first two layers contain 64 hidden units and use GELU activations, while the final layer contains three units corresponding to the normalized , and coordinates.
SBI head. For the SBI experiments, the same pretrained feature encoder is used. The position head is replaced by an MLP with the same two hidden layers of 64 units and GELU activations, but with six output values. These parameterize the posterior distribution used by the SBI model, with three outputs describing the location parameters and three outputs describing the corresponding uncertainty parameters.
Training details. All models are trained using a batch size of 64 for 2000 epochs with the ADAMW optimizer and a learning rate of . The dataset contains 42,186 simulated events, which are split into training, validation, and test sets using an 80/10/10 split. The dataset split is fixed using a random seed of 42, while the data shuffling uses a separate fixed seed. Hyperparameters were selected empirically by evaluating a range of configurations on the validation set, and the configuration yielding the best validation performance was used for the final experiments.
The implementation uses JAX [Bradbury et al., 2018] and Equinox [Kidger and Garcia, 2021], allowing the shared waveform encoder to be applied to the individual detector channels using vectorized operations.
Computational resources. All experiments were performed on a High-Performace Computing cluster using NVIDIA A100 PCIe GPUs with 40 GB of GPU memory. A single model training run required approximately 3 hours of GPU time. The total computational cost of the experiments reported in this work was approximately 50 GPU-hours across all training runs.
C Full-Range Reconstruction Results
This appendix provides the full-range versions of the reconstruction results shown in the main paper. The main-text figures use zoomed views to improve readability.

Figure 6: Uncertainty estimates for synthetic-data events under full illumination across the anode dimension. Uncertainty is shown in the plane, with the ensemble at the top and SBI at the bottom.

Figure 7: Uncertainty estimates for synthetic-data events under full illumination across the cathode dimension. Uncertainty is shown in the z-y plane, with the ensemble at the top and SBI at the bottom.

Figure 8: Uncertainty estimates for real-data events under full illumination across the anode dimension. Uncertainty is shown in the x-y plane, with the ensemble at the top and SBI at the bottom.

Figure 9: Uncertainty estimates for real-data events under full illumination across the cathode dimension. Uncertainty is shown in the z-y plane, with the ensemble at the top and SBI at the bottom.