arXiv(opens in a new tab)cs.CVNov 2026Cited by 1 paper on PaperVantage

Manuscript Offprint

arXiv:2611.02114

CNN-Based Retinal OCT Classification: Research Gap Analysis and a From-Scratch Baseline, ED126-A

Shkelqim Sherifi

Shkēlqim Sherifi

Dept. of Computer Science

University of Tetovo

Tetove, R.N.Macedonia

0009-0006-2227-5533

Festim Halili

Dept. of Computer Science

University of Tetovo

Tetove, R.N.Macedonia

0000-0001-7043-2173

Merita Kasa-Halili

Dept. of Computer Science

University of Tetovo

Tetove, R.N.Macedonia

0009-0001-9778-8820

Abstract- Automated classification of retinal pathologies from Optical Coherence Tomography (OCT) images remains challenging because diagnostically relevant morphological patterns may exhibit substantial inter-class similarity. Although high classification accuracies have been reported on benchmark OCT datasets, cross-study comparison is limited by heterogeneous evaluation protocols and by the limited characterization of compact convolutional neural network (CNN) baselines trained from random initialization. This study addresses this gap through two contributions. First, it provides a focused review of CNN-based retinal OCT classification and identifies methodological considerations relevant to controlled benchmarking. Second, it presents ED126-A, a purpose-built four-class CNN baseline trained from scratch under a documented experimental protocol on the Kermany labeled OCT dataset. The model contains 1,241,380 total parameters, including 1,239,460 trainable parameters, and is evaluated using training-dynamics analysis, class-wise performance metrics, confusion-matrix analysis, confidence analysis, t-SNE representation-space visualization, Grad-CAM, hierarchical feature-map analysis, and one-vs-rest ROC/Precision-Recall analysis. On the image-level held-out test set, ED126-A achieved 95.03% accuracy, with a macro-F1 of 0.9205 and a weighted-F1 of 0.9521. The principal class-conditional limitation occurred for Drusen, which attained a recall of 0.9605 but a precision of 0.7493 and an F1-score of 0.8419. The confusion matrix identified Normal to Drusen and CNV to Drusen as major error channels. These results support the use of ED126-A as a documented from-scratch reference baseline and provide an empirical basis for controlled evaluation of transfer learning, increased depth, attention, multi-scale feature fusion, and calibration in subsequent studies.

Keywords - Optical Coherence Tomography, Retinal Disease Classification, Deep Learning, Convolutional Neural Network, Medical Image Analysis, Computer-Aided Diagnosis.

I. INTRODUCTION

Optical Coherence Tomography (OCT) is a high-resolution, non-invasive imaging modality that provides cross-sectional visualization of retinal structure and enables detailed characterization of morphological changes associated with retinal disease [1], [2], [3], [4], [5]. In particular, OCT is widely used to visualize structural manifestations associated with conditions such as Choroidal Neovascularization (CNV), Diabetic Macular Edema (DME), and Drusen [4], [5], [6]. The availability of large labeled OCT datasets has consequently established retinal OCT classification as an important benchmark problem for automated medical image analysis.

Despite the structural information available in OCT images, reliable interpretation remains challenging because diagnostically relevant patterns may be subtle, spatially localized, and partially overlapping across disease categories [1], [7]. Variability in image acquisition, artifacts, and speckle-related appearance further complicate interpretation, while visually similar manifestations may occur across distinct pathological classes. These characteristics make automated OCT classification a demanding problem in which high aggregate accuracy alone may not adequately characterize class-specific diagnostic behavior.

Convolutional Neural Networks (CNNs) have become a standard approach for retinal image analysis because they learn hierarchical feature representations directly from image data, replacing manually designed feature descriptors with learned convolutional representations [8], [9], [10], [11]. The broader evolution of deep-learning architectures for visual representation and image classification, from multilayer perceptron's to convolutional neural networks and hybrid models, has also been examined in recent architectural surveys [12]. In retinal OCT classification, both a relatively compact, purpose-built CNN (1.24 million parameters) and larger transfer-learning architectures have demonstrated strong performance on established benchmarks. However, reported results are often associated with different architectural designs, training protocols, class distributions, and evaluation procedures, limiting direct attribution of performance differences to individual architectural choices.

Although numerous CNN-based OCT classifiers report high benchmark accuracy, comparatively limited attention has been given to establishing compact, purpose-built baselines under fully documented and controlled experimental protocols. Without such a reference point, the incremental contribution of subsequent architectural enrichment, including ImageNet pretraining, attention mechanisms, or multi-scale feature fusion, cannot be cleanly separated from differences in data handling, optimization, parameterization, or classification-head design. Moreover, aggregate accuracy and weighted metrics may obscure class-conditional failure modes, particularly when the class distribution is heterogeneous. A baseline that reports detailed per-class performance and error structure is therefore useful for establishing a more interpretable reference for subsequent model comparisons.

This study addresses the identified gap by designing and evaluating ED126-A, a purpose-built CNN for four-class retinal OCT classification involving CNV, DME, Drusen, and Normal categories. The model is trained end-to-end from random initialization under a fully documented experimental protocol, without transfer learning or model ensembling. The architecture contains 1,241,380 total parameters, of which 1,239,460 are trainable, and is evaluated on an image-level held-out test set using complementary quantitative and representation-based analyses. The objective is not to claim state-of-the-art performance, but to provide a documented reference baseline whose class-conditional behavior can serve as a controlled point of comparison for subsequent architectural studies.

The study makes two principal contributions. First, it provides a focused review of CNN-based retinal OCT classification and identifies methodological considerations relevant to controlled baseline construction and comparative evaluation. Second, it presents ED126-A as a compact, from-scratch baseline and characterizes its behavior through multi-faceted evaluation, with particular emphasis on class-conditional performance, recurrent confusion patterns, representation-space structure, confidence behavior, and interpretability. The resulting baseline is intended to support controlled evaluation of transfer learning and architectural enrichment in subsequent studies.

The research questions addressed are:

RQ1: Does a purpose-built CNN trained from scratch on the Kermany OCT dataset provide a useful empirical baseline for four-class OCT classification?

RQ2: What are the class-conditional performance characteristics of ED126-A, and which pathological classes constitute the principal sources of residual classification error?

The remainder of this paper is organized as follows: Section II provides a focused review of CNN-based retinal OCT classification and identifies methodological considerations relevant to controlled baseline construction. Section III describes the experimental methodology, including the dataset, data partitioning, preprocessing and augmentation, ED126-A architecture, training configuration, and evaluation protocol. Section IV presents the experimental results. Section V discusses the principal findings, their interpretation, implications for subsequent benchmarking, and study limitations. Section VI concludes the paper.

References (21)