arXiv:2611.02324cs.CVNov 2026

Manuscript Offprint

arXiv:2611.02324

The DynaCell Evaluation Suite for Dynamic 3D Virtual Staining of Live Cells

Alexandr A. Kalinin, Dihan Zheng, Taylla Milena Theodoro, Ivan Ivanov, Eduardo Hirata-Miyasaki, See-Chi Lee, Aofei Liu, Sricharan Reddy Varra, Talon Chandler, Soorya Pradeep, Chad Liu, Manuel D. Leonetti, Carolina Arias, Bo Huang, Shalin B. Mehta

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Abstract

Understanding how cells respond to perturbations over time is central to cell biology and drug discovery. Live-cell imaging captures the dynamics of perturbation-induced phenotypes in individual cells. While fluorescence imaging can visualize specific molecular phenotypes, labeling and repeated illumination often affect cell health. Virtual staining offers an alternative by predicting these fluorescence images from images acquired without fluorescent labels. Although many virtual staining models have been developed, their performance on volumetric time-lapse data remains poorly characterized. We address this gap with an evaluation suite for 3D time-lapse virtual staining of live cells. The suite combines paired 3D time-lapse images acquired with and without fluorescent labels, a set of baseline models, and three metric tiers measuring pixel-level fidelity, organelle segmentation performance, and single-cell phenotype similarity. Using this evaluation suite, we study metric and model behavior across 3 cell types, 2 microscopes, 4 organelles, and 3 perturbation states. We find that regression baselines better predict the spatial localization of target organelles, whereas the generative baseline better captures the distribution of phenotypes across cells. These differences expose trade-offs between structural and phenotypic fidelity that are obscured by single-metric evaluation and suggest how virtual staining models can be developed for diverse downstream tasks such as localization, segmentation, tracking, and phenotypic profiling. We release the curated datasets, baseline checkpoints, and evaluation code as part of DynaCell, a broader framework for image-based profiling of cell-state dynamics.

1 Introduction

Image-based profiling of cells under genetic and chemical perturbations has become central to scalable cell biology and drug discovery [1, 2]. Many perturbations induce changes in organelle organization and cellular state that unfold over time at different rates. However, capturing these dynamics with repeated live-cell measurements requires balancing the molecular specificity of fluorescence imaging against phototoxicity, photobleaching, and other effects on cell health. Virtual staining addresses this trade-off by predicting fluorescence-like images of cell structures from transmitted-light images acquired without fluorescent labels (“label-free” imaging). The same cells can then be imaged repeatedly over time, without genetic modification or fluorescent dyes [3, 4, 5]. Many image-to-image translation models have been developed for cell virtual staining [3, 4, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16] and applied to downstream tasks including nucleus

*Equal contribution.

†Corresponding authors: bo.huang@ucsf.edu, shalin.mehta@czbiohub.org.

40th Conference on Neural Information Processing Systems (NeurIPS 2026). Track on Evaluations and Datasets.

and cell segmentation [17, 18], label-free tracking [19, 20], and perturbation profiling [8, 9]. However, their performance on volumetric time-lapse data remains poorly characterized, limiting both the practical use of virtual staining in biological studies and further method development.

A 3D time-lapse paired label-free and fluorescence imaging

Figure

B Representative training objectives

C Pixel, segmentation, and phenotype metrics

Figure 1: DynaCell evaluation suite. The suite consists of (A) high-resolution 3D time-lapse multichannel datasets, (B) regression, adversarial, and generative virtual-staining baselines trained and evaluated with a consistent protocol, and (C) three metric tiers that compare experimental fluorescence with virtual stains at the pixel, segmentation, and phenotype levels. Spectral PCC reduces sensitivity to noise in experimental fluorescence.

Evaluation of virtual staining for live-cell profiling is constrained by limited paired live-cell data and inconsistent protocols. Public paired collections are predominantly static and 2D [21, 22, 23, 24]. Paired 3D data are less common, particularly time-lapse series capturing cell-state changes in response to perturbations [4, 25, 6, 26]. Most studies report only pixel-level reconstruction metrics [3, 4, 7, 10, 11, 12, 13, 24], which measure resemblance to the target but not whether predictions can replace experimental fluorescence in organelle localization, segmentation, cell tracking, or phenotypic profiling. Segmentation [6, 14, 15, 16] and feature-level metrics [8, 9, 16] are less common and are rarely combined under shared splits and baselines.

To address these gaps, we introduce an evaluation suite for 3D time-lapse virtual staining of live cells, built around three linked components (Fig. 1). This evaluation suite is part of DynaCell, a broader framework for image-based profiling of cell-state dynamics.

Data. To enable model comparison on dynamic live-cell data, we contribute a high-resolution 3D time-lapse A549 dataset acquired with paired label-free and light-sheet fluorescence imaging (Fig. 1A). The dataset covers 20 hours of imaging of 4 organelle targets: nucleus, plasma membrane, endoplasmic reticulum (ER), and mitochondria. Infection with Zika virus (ZIKV) or Dengue virus (DENV) induces organelle remodeling over time [27, 28]. A semi-automated preprocessing and quality-control pipeline reduces the raw data to a curated, model-ready subset (App. F4). The curated dataset contains 262 field-of-view (FOV) time-lapse series across 12 organelle-condition combinations (four organelles under Mock, ZIKV, or DENV conditions). The test set contains 12 FOVs per organelle-condition combination; the remaining quality-controlled FOVs form the A549 training set. We also contribute reprocessed, curated subsets of other datasets for evaluation across cell types and microscopes: the Allen Institute WTC-11 human induced pluripotent stem cell (hiPSC) dataset [25] and the Biohub human embryonic kidney (HEK293T) dataset [26].

Baseline models. To establish reference models, we train regression baselines ranging from a widely used 3D U-Net variant [4] to modern convolutional models with masked-autoencoder pre-training [15]. We also implement a 3D extension of the popular pix2pix model [29] and a 3D flow-matching model based on the 2D diffusion model CELL-Diff [30] (Fig. 1B).

Metrics. To evaluate virtual stains beyond image reconstruction alone, we use a three-tier panel spanning pixel-level fidelity, organelle-segmentation utility, and single-cell phenotype similarity (Fig. 1C). We also introduce a frequency-aware variant of the Pearson correlation coefficient (PCC) to reduce sensitivity to noise in experimental fluorescence targets.

We release preprocessed data, trained model checkpoints, and reusable evaluation code for reproducible comparison. Together, these components help determine when virtual stains can support live-cell biological measurements, how failure modes can inform metric selection and model training, and how model choices affect downstream use.

References (61)