arXiv:2611.02506cs.CVNov 2026

Manuscript Offprint

arXiv:2611.02506

CellPlex: Benchmarking Single-Cell Spatial Proteomics Prediction from H&E

Zijun Gao, Yijiang Chen, Xiangde Luo, Pheng-Ann Heng

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Abstract

Spatial proteomics measures tens of proteins in every cell of a tissue section, but its cost confines it to small research cohorts, whereas hematoxylin and eosin (H&E) slides exist for nearly every patient. Inferring single-cell spatial proteomics from H&E would bring its analyses to routine pathology, and a growing number of virtual staining models pursue this goal. Each is evaluated on its own cohort, panel and pixel-level metric, and released models transfer poorly to new cohorts, leaving open which approach to build on and which proteins H&E can reveal. We introduce CellPlex, a benchmark that poses the task at the level of the cell: seven cohorts with same-section H&E and multiplexed immunofluorescence, from colorectal and breast cancer to lymph-node metastases, bone marrow and glioma, with 717 samples, 44.8 million cells and 149 proteins, processed by one pipeline into per-cell targets. Pathology foundation models (PFMs) are adapted with one cell-level protocol, specialist models are fine-tuned under a matched budget, and all are scored on the same cells. Adapted PFMs are the most accurate models on every cohort, ahead of the specialists even after fine-tuning, but keep less than half of their accuracy on cohorts they were not trained on. Which proteins can be predicted depends on the tissue, not on how many cells were measured for them. By fixing the cells, targets and splits on which predictions are judged, CellPlex sets a common standard for inferring costly molecular measurements from routine H&E and shows how far H&E can stand in for spatial proteomics. We will release the data, splits, evaluation code and baselines as a testbed for developing and comparing future pathology foundation models and virtual staining methods.

1. Introduction

Tissue function and disease arise from the molecular states of individual cells and from how these cells are arranged. Spatial proteomics resolves both: imaging mass cytometry [12], CODEX/PhenoCycler [4, 13], MIBI [22] and Orion [25] measure tens of proteins in every cell of an intact tissue section, exposing immune phenotypes, checkpoint expression, stromal composition and cellular neighborhoods [21, 37]. These readouts inform the study of tumor microenvironments and therapy response and are moving toward clinical decision support [28, 35]. Their cost, throughput and consumption of tissue, however, keep them confined to research cohorts: the largest public collection of spatial proteomics, spora, covers 5,477 patients [41]. Hematoxylin and eosin (H&E) slides, in contrast, are produced for nearly every patient, and pathology foundation models (PFMs) have been pretrained on hundreds of thousands to millions of them [6, 36, 47].

H&E morphology carries much of the information that multiplexed panels make explicit, so inferring single-cell spatial proteomics from H&E would extend these analyses to routine pathology and its archives. A growing number of models pursue this goal by learning from paired H&E and multiplexed images: image-to-image translators that predict a fixed panel [1, 5, 40, 43], predictors built on PFMs [2, 24], and foundation models for spatial proteomics that take H&E as further input channels and, once fine-tuned for the task, predict any requested marker from H&E alone [27].

The field cannot yet tell which of these approaches to build on, because each model has been evaluated on its own terms. The models are trained on different and mostly small corpora (GigaTIME on 21 whole slides and HistoPlexer on 336 regions, each from a single cohort, ROSIE on 1,342 cores [41], MIPHEI-ViT on Orion-CRC [2]), predict different panels, and are scored mainly on held-out data from their own sources. In the spora benchmark [41], GigaTIME, HistoPlexer and ROSIE were applied as released to four cohorts with registered H&E and scored pixel by pixel against the measured images. Averaged over the markers that all

✉Corresponding authors: yijiangc@stanford.edu, luoxd96@stanford.edu

Overall cohortsCohortCellsPatientsSamplesProteins
7Orion-CRCcolorectal cancer · Orion38.0 M4041WSIs16
44.8 Mcells after QCGliomaIDH-mut glioma, GBM · PhenoCycler3.6 M3036sections68
HNSCC-LNHNSCC lymph nodes · CODEX1.5 M79388cores, 3 TMAs57
717samplesBone marrownormal, AML · CODEX772 K1111WSIs52
195+patientsBC/CRCbreast, colorectal cancer · CODEX517 Kn/a45regions36
CRC-TMAcolorectal cancer · CODEX235 K35130cores, 2 TMAs56
149distinct proteinsMulti-tumormultiple tumor types · CODEX148 Kn/a66cores, 1 TMA57

Figure

Figure

UNI2-h · Virchow2 · H-optimus-0, fine-tuned end to end each nucleus queries the token map; supervised per cell (Huber)

Figure

pretrained by masked reconstruction of paired H&E and mIF pixel-level output averaged per cell; fine-tuned with masked MSE

H&E translated into 21 virtual mIF channels pixel-level output averaged per cell; fine-tuned with BCE + Dice

Figure 1. Overview of CellPlex. Left: the seven cohorts with their cells after quality control, patients, samples and proteins, and the construction of per-cell targets, in which nuclei segmented on the H&E are grown into cell regions and the registered multiplexed image is averaged over each region. Right: the evaluated models, pathology foundation models adapted with a cell-level protocol and two specialist models, Eva and GigaTIME, whose pixel-level outputs are averaged over the same cell regions.

three predict, the Pearson correlation stayed below 0.11 for every model and cohort. The second metric, structural similarity (SSIM), ranked the models differently: on the intestine cohort of Hickey et al. [16], HistoPlexer obtained the highest SSIM (0.60) although its predictions were uncorrelated with the measurements (Pearson 0.004), so the two metrics did not even agree on which model was best. Because none of the three models was fine-tuned on these cohorts, the comparison cannot tell whether the low scores reflect the limits of H&E, of the models or of their training data. Benchmarks of PFMs do not fill this gap: they target slide-and patch-level tasks and, for molecular targets, spot-level transcriptomics probed with frozen features [20], where each spot averages the expression of several neighbouring cells, often of different types.

We introduce CellPlex, a benchmark that poses the task at the level of the cell (Fig. 1). It assembles seven cohorts in which H&E and multiplexed immunofluorescence were acquired on the same tissue section, a pairing that only five of the 35 cohorts in spora provide [41]. The cohorts span colorectal and breast cancer, a multi-tumor array, lymph-node metastases of head-and-neck cancer, bone marrow and glioma on two imaging platforms, with 717 samples, 44.8

million cells and 149 proteins. Turning these releases into a benchmark is less a matter of collecting data than of making the task well posed. Nuclei are segmented on the H&E, so that every target belongs to a cell visible at inference time; the multiplexed image is registered to the H&E and every sample is checked for residual misalignment; and the target of a cell is the mean level of each protein over its nucleus and a 2 µm rim. Test cells come from patients or samples held out from training, and every model is scored on the same cells by correlation and structural similarity.

CellPlex compares models under controlled conditions. Every PFM is turned into a cell-level predictor by the same protocol, which samples its token map at each nucleus and refines the feature by attention over the surrounding tile; the architecture follows CELLO [11], and both it and the training recipe are fixed so that the PFM is the only variable. A linear probe on frozen features measures what the PFM provides before adaptation. Two specialist models, Eva [27] and GigaTIME [40], are evaluated as released and after fine-tuning on every cohort with their own objectives and a training budget matched to the PFMs. Finally, models trained on one cohort are applied to every other cohort to measure transfer.

Evaluating UNI2-h [6], Virchow2 [47] and H-optimus-0 [36] in this way, we find:

  • Adapted PFMs are the strongest models. CELLO with H-optimus-0 reaches a mean PCC of 0.532 over the seven cohorts, against 0.460 for fine-tuned Eva and 0.344 for fine-tuned GigaTIME, and is the most accurate model on every cohort; a linear probe on its frozen features reaches 0.446.

  • Transfer across cohorts remains open. Trained on one cohort and applied without further training to another, CELLO with H-optimus-0 reaches a mean PCC of 0.22 over the proteins shared by the two panels, against 0.52 when trained on the target cohort itself and 0.21 for Eva used as released. Transfer works only between closely related cohorts: trained on CRC-TMA, the model reaches 0.39 on the Multi-tumor array, which comes from the same study and panel, against 0.44 when trained on it, whereas on glioma it reaches at most 0.15 when trained on another cohort, against 0.46 on the same proteins when trained on glioma.

  • Which proteins can be predicted depends on the tissue. The same protein can be easy in one cohort and hard in another: with CELLO (H-optimus-0), CD3 reaches 0.66 PCC on Orion-CRC but 0.20 on glioma, and Ki67 0.74 on bone marrow but 0.30 on the Multi-tumor array. Accuracy is unrelated to how many cells a protein was measured in (Spearman ρ=−0.11\rho = -0.11 over 149 proteins) and is higher for proteins whose measured levels are spatially coherent: 0.57 in the upper two quintiles of spatial autocorrelation (Moran's I), against 0.46–0.47 in the lower two.

These results place the remaining difficulty in transfer across tissues and in proteins whose levels vary from cell to cell rather than with tissue architecture. We will release the processed data, splits, evaluation code and baselines of CellPlex as a testbed for future PFMs and virtual staining methods.

References (46)