arXiv:2611.02773Molecular Communication for Plaque Sensing in a Vascular Bifurcation with Receiver Constraints
Personal use of this material is permitted. This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may no longer be accessible.
Molecular Communication for Plaque Sensing in a Vascular Bifurcation with Receiver Constraints
Alexander Wietfeld*, Luiz C. P. Wille*, Pit Hofmann, Jonas Fuchtmann, Randy Gelfert, Frank H. P. Fitzek, Wolfgang Kellerer, and Jens Kirchner
Abstract—Future molecular communication (MC) networks are envisioned to use the human cardiovascular system as a channel. Disease-related changes affect particle transport, allowing an MC receiver to also act as a sensor. In this work, we investigate plaque formation in a carotid bifurcation through a systematic fluid-dynamics simulation study with non-Newtonian blood rheology. We analyze how plaque geometry changes branch-specific particle reception and timing, and use these observations to estimate plaque-induced channel obstruction. At an illustrative reference of only 128 emitted particles, a 250 ms observation window and 50 ms temporal resolution, a Ridge detector estimates maximum local channel-width reduction with a mean absolute error of 8.30 percentage points. We evaluate robustness across system constraints like particle budgets, observation windows, branch access, detection efficiency, count resolution, and synchronization. Coarse counting has little effect when timing features remain available, whereas limited temporal resolution and clock uncertainty substantially affect short-window estimates. Extending the observation window to 1 s reduces these timing-related penalties. The results establish a baseline for plaque sensing from constrained MC observations and identify receiver capabilities relevant to the Internet of Bio-Nano Things.
Index Terms—Internet of Bio-Nano Things, Plaque Formations, Molecular Communication, OpenFOAM, Simulation.
In these IoBNT networks, molecular communication (MC) uses particles transported through blood vessels to convey information between a transmitter (TX) and a receiver (RX). Changes in the propagation environment also affect the received signal. Plaque formation therefore connects MC with sensing. By observing changes in particle reception and arrival timing, an RX can obtain information about the physical channel through which the particles have traveled.
Felicetti et al. [6], [7] model natural signaling between blood platelets and endothelial cells during plaque formation. Synthetic MC offers a complementary perspective by using an engineered communication signal to sense changes in the vessel. Our previous work demonstrates plaque-dependent changes in propagation delay and cumulative particle reception in a simplified straight carotid vessel [8] as well as the impact of arterial plaque tissue elasticity [9]. We subsequently extended this model to non-Newtonian fluid dynamics and pulsatile flow [10]. Wille et al. [11] further investigate the influence of pulsatile flow on nanoparticle propagation in mid-sized arteries.
Sun et al. [12] investigate plaque detection through simulated particle-arrival responses. Shao et al. [13] estimate stenosis location and severity from peak-response delay using idealized symmetric, bell-shaped constrictions. Baghel et al. [14] model molecular transport through a symmetric stenosis using one-dimensional drift-diffusion with a spatially averaged flow velocity. Building on these approaches, we study estimation of plaque-induced channel obstruction in a bifurcated channel and explicitly vary the information available to the RX.
We investigate which physical plaque properties can be estimated from constrained downstream MC observations. Our contributions are (i) characterizing particle routing and arrival timing across 30 plaque geometries in a carotid bifurcation; (ii) comparing compact detectors using particle counts, timing, or both, with complete test geometries excluded from training to capture generalization capabilities; and (iii) evaluating robustness to particle budget, observation duration, and five additional RX constraints. This connects plaque-sensitive channel behavior to the information requirements of a sensor.
The authors contributed equally to this work.
A. Wietfeld and W. Kellerer are with the Chair of Communication Networks, Technical University of Munich, Germany (e-mail: {alexander.wietfeld,wolfgang.kellerer}@tum.de).
L. Wille and J. Kirchner are with the Institute for Smart Electronics and Systems, Friedrich-Alexander-Universität Erlangen-Nürnberg, Germany (e-mail: {luiz.wille,jens.kirchner}@fau.de). J. Kirchner is also with the Department of Information Technology, Fachhochschule Dortmund University of Applied Sciences and Arts, Germany.
P. Hofmann, R. Gelfert, and F. Fitzek are with the Deutsche Telekom Chair of Communication Networks, TUD Dresden University of Technology, Germany, and the Centre for Tactile Internet with Human-in-the-Loop (CeTI), Dresden, Germany (e-mail: {pit.hofmann,randy.gelfert,frank.fitzek}@tu-dresden.de).
II. SYSTEM MODEL
Jonas Fuchtmann is with the Minimally Invasive Interdisciplinary Therapeutic Intervention research group, Department of Clinical Medicine, TUM School of Medicine and Health, Technical University Munich, Germany (e-mail: jonas.fuchtmann@tum.de).
We consider a two-dimensional section of a carotid bifurcation, extending the straight-vessel plaque scenario in [8], [10]. The parent vessel has diameter mm and branches into the internal carotid artery (ICA) and external carotid artery (ECA). Fig. 1 shows the healthy channel as the black

Fig. 1: Healthy channel outline and all 30 plaque geometries. Flow runs from left to right. Axes correspond to the simulation coordinates, with y horizontal and x increasing downward.
outline and the investigated plaque geometries in different shades of blue, ranging from modest plaque sizes to extreme stenosis. In model coordinates, y runs along the parent vessel and x across it. The nominal computer-aided design (CAD) parameters , and identify the position and radius parameters used to construct the plaque.
Let and denote the total available channel width in the healthy reference and plaque geometry g. We use the maximum local width reduction
as the primary estimation target, expressed in percent. The supplementary target is the plaque-obstructed channel area
where and are the healthy and plaque channel domains.
Particles released upstream propagate to two idealized RXs at model mm. Negative and positive identify the ICA and ECA, respectively. Each particle is assigned its first crossing time relative to the start of injection and its receiving branch. For branch , the cumulative received fraction by time is
where is the released particle count, is the receiving branch and is the indicator function. Particles without an RX crossing have .
III. SIMULATION SETUP AND DATASET
A. Physiologically-inspired Flow Conditions
Blood is a non-Newtonian fluid that exhibits a shear-dependent viscosity, i.e., the effective viscosity lowers at higher shear rates . Similar to prior work [8], [10], the viscosity is calculated based on the Casson fluid model, given as
with constant blood density [15] and coefficients , .

Fig. 2: Simulation result of the fluid and particle simulation for time step 0.044 s after particle release. The legend visualizes the fluid velocity magnitude. Black dots represent the particles.
The average flow in a carotid artery has been measured in [16] with a mean of for healthy adults. This results in an average blood velocity of
with mm as the diameter of the carotid as defined in Sec. II. In reality, the blood flow will oscillate periodically due to discrete heartbeats, but prior work has shown that often the steady flow rate equivalent can be used to analyze particle spreading over time [11]. Therefore, in this work, we will simplify our simulation approach by only using the steady flow component.
The exact shear rate and viscosity will be part of the simulation results, but we can estimate the wall shear rate based on , which leads to an average viscosity of . Based on the given flow parameters, we can estimate the Reynolds number [8] as . Since the Reynolds number is well below the critical limit [8] of 2300, we assume laminar flow conditions for the simulation scenarios.
B. Flow Simulation
The blood flow in the branching vessel structure is numerically simulated utilizing the simpleFoam solver from the OpenFOAM environment. This solver uses the Navier-Stokes equations on a discretized mesh to iteratively obtain a balanced flow field. In our case, the domain is reduced to a two-dimensional slice through the carotid branch with a depth of 0.1 mm. Thus, the flow is limited to x-, and y- direction.
1 ) Boundary Conditions
The velocity from (5) is used at the inlet as a constant boundary condition, while it is set to zero at the vessel walls (no-slip boundary condition). For the outlets, a zero-gradient boundary condition (Neumann condition) is used for outgoing flux, while any net backflow (negative flux) is prevented with a zero-value condition. Additionally, we don't impose a fixed velocity profile at the inlet, but let the solver produce an interpolated profile. Due to the curvature features caused by the plaque in our geometry, the velocity profile has the freedom to be skewed; see Fig. 2.
For the relative pressure, a reduced Windkessel model [17] is applied at the outlets, and a Neumann boundary condition is set on all other surfaces. The reduced Windkessel model consists of a terminal resistance , which corrects the outlet pressure based on the solved outlet flow rate with
The resistance represents the rest of the vessel network beyond our simulated geometry of the carotid branch. This leads to physiologically meaningful pressure and flow rate values. Based on values from the literature [17], we define the terminal resistance of the carotid as . This value is adjusted with the ratio of the real 3D- to the used 2D- cross section area . Since we have two outlets, the value is applied with factor 2 at each outlet (parallel resistance).
C. Particle Simulation
For the particle simulation, we apply a simple Lagrangian advection scheme [18], where the forces acting on the particles are summed up at each time step to retrieve the particle velocity and update the particle position . Similar to other works, the particles are small enough to assume that the fluid drag force is the only major influence on the movement on small time scales [11], leading to the following differential equation for the forces acting upon the particles
The particle properties are representing Superparamagnetic Iron-Oxide Nanoparticles (SPIONs) [18] with particle diameter nm and single particle density 2047 kg/m . The velocity field is obtained through the prior flow simulation (see Sec. III-B).
The particles are introduced at the carotid inlet at time s with count uniformly over the x-coordinate at mm. The simulation stops after s, since most particles will have reached the branch ends by this time.
We employ a very fine boundary layer at the wall with 15 layers decreasing in size towards the wall in order to capture flow gradients very accurately and thus minimizing nonphysical particle wall contacts. If a particle comes into contact with the wall, an elastic rebound is conducted, since we assume non-sticking particle properties.
D. Dataset and Post-Processing
The dataset contains 30 plaque geometries and one healthy reference, each with one realized release of particles. The plaque cases span and . Both metrics are calculated from the channel geometry and vary within the investigated family. A dataset with corresponding solutions is openly available under [19].
We reconstruct RX crossings from saved particle trajectories and express arrival times relative to injection. Full-release

(c) ICA timing
(d) Example response
Fig. 3: Channel characteristics for full releases of 10 000 particles. Open diamonds mark the healthy reference. Panels (a)–(c) use the 5 s analysis window. Panel (d) compares the healthy case with a plaque having and marks the 0.25 s and 1 s RX windows.
channel statistics use the analysis window. Smaller particle subsets and shorter observation windows are subsequently used to represent constrained MC observations.
IV. PLAQUE-DEPENDENT CHANNEL CHARACTERISTICS
The bifurcation adds branch-specific particle routing to the count and delay changes observed in straight vessels [8], [10]. Fig. 3(a) compares the ECA share of net outlet fluid flow with its share of received particles. Net fluid flow remains approximately balanced, with an ECA share of 49.29–50.00%. Particle routing changes more strongly, with 50.99–67.94% of received particles reaching the ECA. Across plaque cases, this fraction increases with the width reduction , with a Pearson correlation coefficient of 0.944.
Fig. 3(b) shows that 82.68–99.22% of emitted particles reach either RX within 5 s. Reception decreases with increasing width reduction, with correlation -0.879. The ICA median arrival time also decreases, as shown in Fig. 3(c), with correlation -0.947.
Fig. 3(d) illustrates these effects for the healthy channel and a plaque with 37.59% maximum width reduction. The plaque response rises earlier and redistributes cumulative reception between the branches. Together, the systematic trends and the example response identify particle routing and arrival timing as complementary sources of information for plaque estimation.
V. PLAQUE DETECTION AND ESTIMATION
A. Receiver Observations and Constraints
A derived RX observation consists of trajectories sampled without replacement from one simulated release. We generate observations per geometry and setting. These
TABLE I: Evaluated particle budgets and RX constraints.
| Parameter (unit) | Evaluated values |
|---|---|
| N (particles) | 32, 64, 128, 256, 512, 1000, 2500, 5000, 10000 |
| T (s) | 0.25, 0.5, 1, 1.5, 2, 3, 5 |
| (s) | 0.025, 0.05, 0.1, 0.25, 0.5, 1 |
| 1, 0.75, 0.5, 0.25, 0.1 | |
| (s) | 0, 0.025, 0.05, 0.1, 0.25 |
| Count levels L | Exact, 32, 16, 8, 4 |
| Branch access | Both, ICA only, ECA only, pooled |
subsets represent particle-sampling variability within the same physical simulation.
The observation horizon is the deadline after injection, and is the RX time-bin width. Each particle is detected independently with probability . A common clock offset applies to all timestamps in an observation. The reported arrival time is
An arrival contributes when it is detected and both and .
Branch access determines whether the RX observes both outlets separately, one outlet, or their pooled arrivals without branch identity. Finite count resolution rounds counts to L equally spaced levels between 0 and N. Timing features retain the detected timestamps.
Our comparison reference uses , s and ms, both branches, , exact counts and . We add s as a longer-window comparison. Table I defines the robustness sweeps around these default conditions.
B. Features, Detectors, and Evaluation
Let and denote observed branch counts in the ICA and ECA respectively, and . Count features are , , , the unobserved count , received fraction , branch fractions and , imbalance , and . Timing features comprise each accessible branch's first arrival, 10th, 50th, and 90th percentiles, mean and standard deviation. With both branches accessible, we also include differences of their first arrivals and percentiles. Single-branch and pooled RXs use only their accessible counts and timing. We compare count-only, timing-only, and combined features.
For each target , i.e. reduced channel width or obstructed channel area, the detector maps the available feature vector to an estimate. Ridge is the primary linear baseline, fitted by squared-error minimization with an coefficient penalty of weight 1. Robust linear regression uses the Huber loss, which reduces the influence of large residuals, with transition parameter 1.35 and penalty . The -nearest-neighbor (KNN) detector averages the targets of the five closest training observations using inverse Euclidean-distance weights. The decision tree uses successive feature thresholds, with maximum depth 3 and at least five observations per leaf. The multilayer perceptron (MLP) has one hidden layer of 16 units and penalty .

Fig. 4: Ridge estimates using counts and timing at the reference setting. Each target includes all 600 test observations from 30 geometries. The dashed line denotes exact prediction.
All models are fitted separately for each target, feature set, and RX condition. Missing features use training-set medians, or zero for an entirely missing column. Features are standardized using training-set means and standard deviations for all models except the tree. Detector settings remain fixed across comparisons.
We partition the 30 plaque geometries into five groups, training on four and testing on the fifth in turn. Every observation of a test geometry is excluded from training. A stricter test excludes all geometries sharing one nominal level. For predictions , we report mean absolute error (MAE) and the coefficient of determination ,
where , and is the mean target across geometries. Width MAE is reported in percentage points (pp), and area MAE in mm. Prediction accuracy, detector and grid plots use one observation seed, while observation-time and RX-constraint curves average three observation seeds and three assignments of the five geometry folds.
C. Estimation Results
Fig. 4 shows Ridge estimates at the reference setting. Maximum width reduction is estimated with 8.30 pp MAE and . For the obstructed area, the corresponding values are 5.26 mm and . The true vs. predicted plots show the spread of individual observations around each geometry's true value.
Fig. 5(a) compares the five detectors. KNN achieves 7.27 pp with combined features and 6.85 pp with timing alone. Compact nonlinear processing therefore improves on Ridge for this comparison. Excluding an entire position-parameter level in Fig. 5(b) increases Ridge's combined-feature error to 11.65 pp. This stricter test highlights the influence of the geometry variation represented in training, but shows that the performance stays relatively stable.
Fig. 5(c) shows a strong dependence of count-only width estimation on the observation window. Its mean error falls

Fig. 5: Width-estimation MAE for three feature sets. Panels (a,b) compare five detectors at the reference using geometry-separated and omitted-position-level tests. Panel (c) shows Ridge horizon sensitivity, with nine-setting means and min-max bands.
from 16.73 pp at 0.25 s to 10.67 pp at 1 s and 9.58 pp at 2 s. Combined-feature errors are 9.23, 8.77, and 8.80 pp, respectively. Timing provides most of its relative benefit when the RX has access only to the early response.
D. Robustness to Receiver Constraints
Fig. 6 evaluates the information available through particle budget and observation duration. At s, increasing from 128 to 1000 reduces Ridge width MAE from 8.30 to 7.02 pp. The full grid describes sensitivity to these resources, including non-monotonic changes. MAE ranges from 5.76 to 10.05 pp across settings, indicating that estimation works across the entire evaluated grid, even for small numbers of particles and short observation times.
Fig. 7 varies one RX factor at a time around a reference point. Temporal resolution and synchronization have the largest short-window effects, i.e., for s. At ms, Ridge error is 16.73 pp for s and 9.57 pp for s. A clock-offset standard deviation of 250 ms gives 16.95 and 9.94 pp. Longer observation captures more of the response and reduces the penalties.
At s, four-level counting changes error only from 9.23 to 9.27 pp, whereas detection efficiency raises it to 12.72 pp. In this scenario, Ridge is robust to coarse counting when timing information remains available. Branch access also matters. Errors are 9.23, 8.41, 12.67 and 9.30 pp for both branches, ICA only, ECA only and pooled reception, respectively, indicating that the arrival from the branch without the plaque seems to convey more information. Pooled reception also retains performance close to the two-branch reference, making branch identification less critical for this Ridge detector.

Fig. 6: Ridge width MAE across all 63 combinations, using combined features and 20 observations per geometry. The star marks the default comparison reference.
Overall, the observation window, accessible branches and timing capabilities jointly determine the estimation performance.
E. Healthy-Reference Plaque Detection
We additionally evaluate an exploratory anomaly detector using the healthy release as a reference. Its eight features are received fraction, branch imbalance, and the three arrival-time percentiles per branch divided by . The score is the root-mean-square distance from the mean healthy feature vector.
For each of eight random partitions, disjoint healthy particle pools are used for reference fitting, threshold calibration and evaluation. The threshold is the 95th percentile of calibration scores. Fig. 8 shows scores normalized by this threshold. At the reference parameter point, 4.17% of healthy evaluation observations and 94.13% of plaque observations exceed it, with 28 of 30 plaque medians above the threshold, indicating that plaque presence can be differentiated from the healthy case with high likelihood. At and s, healthy false positives increase to 15.21 %, identifying healthy-reference calibration as an important next step.
F. Scope of the Results
The results describe one parameterized bifurcation under steady flow, with one release per geometry. Width reduction, obstructed area, and cross-channel plaque position vary together. In a separate trial investigation, we find that the evaluated estimators do not reliably recover plaque position along the channel. RX time-bin sweeps act on reconstructed trajectories with finite saved-time resolution. Independent releases, broader healthy references, and varied anatomies could extend this baseline and bring it closer to physical validation.
VI. CONCLUSION AND OUTLOOK
In this paper, we analyzed plaque-dependent particle transport in a carotid bifurcation and estimated channel obstruction from constrained MC observations. Branch-specific reception and arrival timing are used as informative features for a set of compact detectors. A robustness analysis identifies temporal resolution and synchronization as important short-window constraints and shows how a longer observation

Fig. 7: Ridge width MAE under five one-factor RX constraints at . Curves compare s and 1 s. Bands show seed/fold min-max ranges, not confidence intervals. Crosses mark settings with no completed positive-time bin.

Fig. 8: Healthy-reference anomaly score divided by its calibration threshold. Points and whiskers show geometry medians and interquartile ranges across derived observations. The open diamond marks the healthy reference.
window reduces their influence. Coarse counting can still be effective when timing information remains available. Future work will extend the healthy-reference calibration, evaluate independent releases, varied vascular geometries, and consider experimental receiver implementations.
REFERENCES
[1] R. Ross, “Atherosclerosis — An Inflammatory Disease,” N. Engl. J. Med., vol. 340, no. 2, pp. 115–126, Jan. 1999. [2] P. Song et al., “Global and Regional Prevalence, Burden, and Risk Factors for Carotid Atherosclerosis: A Systematic Review, Meta-Analysis, and Modelling Study,” Lancet Glob. Health, vol. 8, no. 5, e721–e729, May 2020. [3] I. F. Akyildiz, M. Pierobon, S. Balasubramaniam, and Y. Kouchervamy, “The Internet of Bio-Nano Things,” IEEE Commun. Mag., vol. 53, no. 3, pp. 32–40, Mar. 2015. [4] M. Kuscu and B. D. Unluturk, “Internet of Bio-Nano Things: A Review of Applications, Enabling Technologies and Key Challenges,” ITU J. Future Evol. Technol., vol. 2, no. 3, pp. 1–24, Dec. 2021. [5] M. Egan et al., “Toward Interdisciplinary Synergies in Molecular Communications: Perspectives from Synthetic Biology, Nanotechnology, Communications Engineering and Philosophy of Science,” Life, vol. 13, no. 1, Jan. 2023, Art. no. 208. [6] L. Felicetti, M. Femminella, G. Reali, P. Gresele, M. Malvestiti, and J. N. Daigle, “Modeling CD40-Based Molecular Communications in Blood Vessels,” IEEE Trans. NanoBiosci., vol. 13, no. 3, pp. 230–243, Sep. 2014.
[7] L. Felicetti, M. Femminella, and G. Reali, “Simulation of Molecular Signaling in Blood Vessels: Software Design and Application to Atherogenesis,” Nano Commun. Netw., vol. 4, no. 3, pp. 98–119, Sep. 2013. [8] P. Hofmann et al., “A Molecular Communication Perspective on Detecting Arterial Plaque Formation,” IEEE Trans. Mol. Biol. Multi-Scale Commun., vol. 10, no. 3, pp. 458–463, Sep. 2024. [9] P. Hofmann et al., “The Impact of Arterial Plaque Tissue Elasticity on In-Body Molecular Communication Scenarios,” in Proc. 9th Workshop on Molecular Communications, Apr. 2025. [Online]. Available: https://molecularcommunications.org/wp-content/uploads/2025/05/3-5_Hofmann.pdf [10] A. Wietfeld et al., “Advanced Plaque Modeling for Atherosclerosis Detection Using Molecular Communication,” in Proc. IEEE ICC, Jun. 2025, pp. 6056–6062. [11] L. C. P. Wille, C. Pfannenmüller, and J. Kirchner, “From Steady to Pulsatile Flow in Molecular Communication: Propagation of Nanoparticles in Mid-Sized Arteries,” IEEE Trans. Mol. Biol. Multi-Scale Commun., vol. 11, no. 4, pp. 531–536, Dec. 2025. [12] Y. Sun, M. Liu, Y. Xiao, and Y. Chen, “A Novel Molecular Communication Inspired Detection Method for the Evolution of Atherosclerosis,” Comput. Methods Programs Biomed., vol. 219, Jun. 2022, Art. no. 106756. [13] Z. Shao, P. Zhang, X. Wang, and P. Lu, “The Modeling and Detection of Vascular Stenosis Based on Molecular Communication in the Internet of Things,” J. Sens. Actuator Netw., vol. 14, no. 5, Oct. 2025, Art. no. 101. [14] A. Baghel, D. Das, and R. Mahapatra, “Communication-Inspired Modeling of Molecular Transport Dynamics in Stenosed Arteries Toward IoBNT System,” IEEE Commun. Lett., vol. 30, pp. 2048–2052, May 2026. [15] T. Kenner, “The Measurement of Blood Density and its Meaning,” Basic Res. Cardiol., vol. 84, no. 2, pp. 111–124, Mar. 1989. [16] N. Ackroyd, R. Gill, K. Griffiths, G. Kossoff, and M. Appleberg, “Quantitative Common Carotid Artery Blood Flow: Prediction of Internal Carotid Artery Stenosis,” J. Vasc. Surg., vol. 3, no. 6, pp. 846–853, Jun. 1986. [17] N. Xiao, J. Alastruey, and C. A. Figueroa, “A Systematic Comparison between 1-D and 3-D Hemodynamics in Compliant Arterial Models,” Int. J. Numer. Methods Biomed. Eng., vol. 30, no. 2, pp. 204–231, Feb. 2014. [18] K. Xiao, A. S. Thalmayer, J. Kirchner, and G. Fischer, “Physics of SPION–Surface Interactions in Fluidic Channels: Implications for Molecular Communication Systems,” IEEE Trans. Mol. Biol. Multi-Scale Commun., vol. 12, pp. 504–509, Apr. 2026. [19] A. Wietfeld et al., Dataset - Molecular Communication for Plaque Sensing in Vascular Bifurcations: Channel Effects and Receiver Constraints, Dataset, 2026. [Online]. Available: https://doi.org/10.5281/zenodo.23082665