arXiv:2611.02884cs.RONov 2026

Manuscript Offprint

arXiv:2611.02884

AnchorHEC: Targetless Hand-Eye Calibration of Wrist and Fixed Cameras

Guebin Hwang, Taeyeop Lee, Yeonseo Lee, Hyosup Shin, Sungho Jo

Guebin Hwang, Taeyeop Lee, Yeonseo Lee, Hyosup Shin, and Sungho Jo†

Abstract—Recent robot systems combine wrist and fixed cameras, requiring camera-to-robot transforms for both. Most hand-eye calibration methods rely on targets or robot-body observations. Scene-based methods using 3D reconstruction require neither but address only wrist cameras. We introduce AnchorHEC, a targetless hand-eye calibration framework for wrist and fixed cameras in a single procedure using RGB images, forward kinematics (FK), and known camera intrinsics. We initialize both camera types using FK and a shared 3D foundation model reconstruction. FK-constrained wrist-image bundle adjustment reduces the impact of reconstructed pose and scale errors. If this refinement fails or retains too few inliers, we relax the constraints on potentially inaccurate FK poses and lens parameters. We use the refined wrist transform and FK to triangulate metric points and estimate fixed-camera poses. Across three backbones, calibration errors in simulation decrease by 86.4% in translation and 71.6% in rotation, averaged over both camera types, relative to reconstruction-based baselines. We also validate AnchorHEC on a physical robot. Project page: https://hwanggb.github.io/AnchorHEC/

Index Terms—Calibration and Identification, Computer Vision for Automation, Sensor Fusion, Deep Learning for Visual Perception

I. INTRODUCTION

Camera-to-robot transforms enable vision-based control and policies that predict robot actions in camera coordinates [1] or explicitly condition on camera pose [2]. Recent manipulation systems combine wrist-mounted (eye-in-hand) cameras for close-up views with fixed (eye-to-hand) cameras for broader workspace coverage [3], [4]. Using both views in robot coordinates requires the rigid transforms from the wrist camera to the end effector and from each fixed camera to the robot base, which hand-eye calibration estimates [5], [6].

Existing hand-eye calibration methods fall into three categories by what they observe: target-based, robot-body-based, and scene-based. The first two handle both camera types. Target-based methods [6], [7], [8] use known calibration patterns, such as ArUco [9] or AprilTag [10]. Camera remounting, changes in fixed-camera pose relative to the robot base [11], and vibration-induced mounting drift [12] can require recalibration. Each recalibration requires manually setting up a target board and keeping it within the camera's field of view throughout data collection.

Robot-body-based methods avoid calibration targets by estimating camera-to-robot transforms from observations of the robot itself. Some methods require robot-specific visual training [13], [14]. CAD-based approaches use robot

Figure

Fig. 1. AnchorHEC overview. Joint reconstruction and forward kinematics (FK) initialize camera-to-robot transforms for wrist and fixed cameras. The refined wrist transform and FK anchor metric scene geometry for fixed-camera registration. Green markers denote end-effector poses. Orange and blue denote wrist and fixed cameras, respectively.

or end-effector models [15], [16], [17], while reference-point tracking requires selecting a suitable point with known coordinates on the robot [18]. These methods therefore depend on models or reference points prepared for each robot or end effector, and they cannot use images in which the required robot features are occluded or outside the field of view.

Scene-based methods remove the need for calibration targets and robot-body observations by estimating camera motion through 3D reconstruction of the surrounding scene [19], [20], [21], [22], [23]. Existing scene-based methods, however, handle only wrist cameras. They recover the wrist transform by relating camera motion between views to end-effector motion between those views. Fixed cameras do not move with the end effector, so calibrating both camera types requires an additional step to obtain the fixed-camera extrinsics.

Recent scene-based methods use 3D foundation models (3DFMs) [21], [22], [23]. These models estimate camera poses and scene geometry in a common coordinate frame from images captured at widely separated viewpoints [24], [25], [26]. Using such reconstructions to calibrate wrist and fixed cameras in a single procedure remains underexplored.

The key observation for extending scene-based calibration to both camera types is that fixed-camera poses can be related to those of the moving wrist camera through a joint reconstruction of their images. However, recovering camera-to-robot transforms from this reconstruction still requires metric scale and alignment with the robot base. Moreover, errors in the reconstructed camera poses can propagate to the calibration estimates.

To address these challenges, we present AnchorHEC (Fig. 1), a targetless hand-eye calibration framework for wrist and fixed cameras in a single procedure without robot-body

All authors are with the Korea Advanced Institute of Science and Technology (KAIST), Daejeon, South Korea.

†Corresponding author

This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may no longer be accessible.

TABLE I TARGETLESS CAMERA-TO-ROBOT CALIBRATION METHODS

MethodWrist cameraFixed cameraSingle runRobot-specific visual requirements
Robot-body-based
DREAM [13]✗✓✗Robot-specific trained model
Valassakis [14]✓✗✗Robot-specific trained model
FEEPE [15]✗✓✗End-effector CAD
EasyHeC [16]✗✓✗Robot CAD and trained models
EasyHeC++ [17]✓✓✗Robot CAD
Kalib [18]✓✓✓Selected robot reference point
Scene-based
JCR [21]✓✗✗
Bi-JCR [22]✓✗✗None
Calib3R [23]✓✗✗
AnchorHEC (ours)✓✓✓

Checks indicate what the cited work demonstrates. “Single run” denotes calibration of both wrist and fixed cameras in one run of a common calibration procedure, rather than one camera type at a time. EasyHeC++ supports the two camera types separately.

references (Table I). The framework comprises three stages: shared reconstruction frame initialization, wrist-camera refinement, and fixed-camera registration. Wrist motion and forward kinematics (FK) constrain the metric scale and robot-base alignment of the joint reconstruction, initializing camera-to-robot transforms for both camera types.

We initialize the wrist transform from reconstructed relative motions, using FK to select view pairs with diverse rotation axes because each pair leaves translation along its rotation axis undetermined. Because wrist-transform errors propagate to fixed-camera initialization, we refine the wrist transform using wrist-image reprojection and metric FK constraints through bundle adjustment (BA) [27], [28]. If BA fails or retains too few inliers with the FK poses and lens parameters held fixed, we allow FK corrections and lens refinement. If refinement lacks sufficient image support, we return the initial wrist estimate.

We register each fixed camera to metric points triangulated from wrist-camera poses given by the refined wrist transform and FK, reducing reliance on reconstructed fixed-camera poses. This requires correspondences between wrist and fixed-camera images, which can be difficult to establish across large viewpoint differences. We use dense matching [29] to obtain these correspondences. We use the number of inlier correspondences and a test for competing camera poses to decide whether to accept registration. If registration is not accepted, reconstruction-based estimates provide a fallback.

We validate our approach across different reconstruction backbones in simulation and evaluate both camera types on a physical robot.

Our contributions are:

  • A scene-based framework for targetless calibration of wrist and fixed cameras in a single procedure from RGB images of a common scene, FK, and known intrinsics.

  • Kinematics-anchored wrist-camera estimation combining FK-guided pair selection with image-based refinement to reduce the impact of reconstruction errors.

  • Fixed-camera calibration through registration to metric scene geometry anchored by the refined wrist transform and FK.

References (41)