arXiv:2611.03418cs.RONov 2026

Manuscript Offprint

arXiv:2611.03418

Myoelectric Control for Upper-Limb Exoskeletons: A Decoder-Shaper-Controller Framework, Design Guidelines, and Future Directions

Davide Costanzi, Eldison Dimo, Emanuele Feola, Mario Sedilesu, Francesco Pascucci, Andrea Calanca

Davide Costanzi¹, Eldison Dimo¹, Emanuele Feola², Mario Sedilesu¹, Francesco Pascucci¹ and Andrea Calanca¹

Abstract—Myoelectric Control Systems (MCSs) enable voluntary control of wearable robots through muscle activity. However, intention decoding, assistance shaping, and low-level actuator control are often not explicitly distinguished, making their contributions difficult to evaluate and compare. This review introduces a functional decoder–shaper–controller framework for continuous myoelectric control of upper-limb exoskeletons. The decoder estimates an intention-related variable from surface electromyography (sEMG), the shaper maps it to a control reference according to an assistance policy, and the controller realizes that reference through actuator control. This decomposition separates intention estimation from assistance-policy design and enables comparison of heterogeneous architectures. Representative approaches are critically examined in terms of module design, calibration, and evaluation. The analysis highlights that the shaper, despite determining the magnitude and shape of assistance, lacks established design and tuning methodologies and is often embedded within the decoder or controller. Key open issues include inconsistent reporting of assistance levels, limited use of interaction-aware stability and passivity tools, and insufficient validation across degrees of freedom, users, and tasks. Building on these findings, this review provides design guidelines for systematic module-wise tuning and identifies future research priorities to bridge the gap between accurate intention decoding and safe, effective, and generalizable assistance under real-world operating conditions.

Index Terms—Myoelectric Control, Electromyography, Exoskeleton, Human Augmentation, Upper-limb

I. INTRODUCTION

The growing demand for physical assistance and functional augmentation is driving the development of wearable robotic systems for industrial, rehabilitation, and daily-living applications. In industrial settings, wearable robots can reduce musculoskeletal strain during repetitive or load-bearing tasks [1]. In rehabilitation and activities of daily living (ADLs), they can compensate for declining physical capacity in an aging population and support functional autonomy [2].

Upper-limb exoskeletons pose distinct challenges compared with their lower-limb counterparts, because of the kinematic

complexity of the human arm, which involves multiple degrees of freedom (DOFs), a wide workspace, and highly variable movements requiring dexterity, precision, and adaptability. Effective upper-limb assistance therefore requires control strategies that can continuously and appropriately respond to the wearer's movement intention [3], [4]. Voluntary control is therefore a key capability for wearable robots. In the literature, it is generally based on measurements of signals originating from the central nervous system, as in brain-machine interfaces, or from the peripheral nervous system, such as those associated with voluntary muscle activation. Among non-invasive approaches, muscle activity measurements are particularly attractive for continuous voluntary control because they provide a direct correlate of voluntary muscle control. Muscle activity can be assessed using several non-invasive sensing modalities, including surface electromyography (sEMG), mechanical, ultrasound-based, optical, and electrical impedance techniques [5]–[10]. Although the framework we propose is applicable in principle to other sources of peripheral muscle-related information, in the present review we decided to focus on sEMG, the most established and widely used non-invasive technique for continuous voluntary control.

In this paper, a myoelectric control system (MCS) is described as the complete control chain from myoelectric signal acquisition to actuator command execution. An MCS forms an artificial sensorimotor pathway that acts in parallel with the biological limb, as in exoskeletons, or functionally replaces it, as in prostheses. MCSs are a mature technology in prosthetic applications, with commercial systems enabling control of multi-DOF artificial limbs [11], [12]. In this context, wearers can adapt to and successfully use non-physiological mappings between available myoelectric signals and prosthetic motor commands, and can develop new motor representations through training [13].

Applying MCSs to assistive exoskeletons introduces additional constraints. Unlike prostheses, which replace missing limbs and act in series with the body, exoskeletons operate in parallel with the biological limb. They therefore require appropriate mechanical alignment and compliance, as well as a high degree of temporal and functional coherence between the user's muscle activity, movement, and the assistance provided by the device, to avoid disrupting natural or residual movements [14]. Excessive delay or inappropriate device responses may also interfere with the wearer's sense of agency, or perception of having control over the device [15].

¹Davide Costanzi, Eldison Dimo, Mario Sedilesu, Francesco Pascucci and Andrea Calanca are with the Department of Engineering for Innovation Medicine, University of Verona, Strada Le Grazie 15, 37134 Verona, Italy (e-mail: davide.costanzi@univr.it, eldison.dimo@univr.it, mario.sedilesu@univr.it, francesco.pascucci_01@univr.it, andrea.calanca@univr.it).

²Emanuele Feola is with the Department of Biomechanical Engineering, University of Twente, 7522 NB Enschede, The Netherlands (e-mail: e.feola@utwente.nl).

*These authors contributed equally to this work.

Table I REPRESENTATIVE RECENT REVIEWS ON TOPICS RELATED TO CONTINUOUS MYOELECTRIC CONTROL.

Ref.YearArchitectureTopics
[16]2015Continuous/discrete decoderRecommended practices and future research on myoelectric interfaces
[17]2015Decoder, controllerSensor fusion methods for wearable robots
[18]2020Decoder, controllerKey technologies for human-robot interaction based on sEMG
[19]2022DecoderMachine-learning and deep-learning methods for robust, adaptive, and reliable upper limb motion estimation for myoelectric control
[5]2022Decoder, controllerMCSs for upper limb wearable robotic exoskeletons and exosuits
[20]2023DecoderNeuromusculoskeletal biomechanics: neural control, muscle-tendon dynamics, musculoskeletal modeling, and digital-twin applications
[21]2024DecoderModel-based and model-free approaches for continuous upper limb motion intention prediction from sEMG
[22]2024Continuous/discrete decoderIntuitive Human-Robot-Environment Interaction (HREI) with sEMG
[23]2025Decoder, controllerMCSs for rehabilitative and assistive soft exoskeletons, with emphasis on soft-robotic integration and real-time adaptation

Recent reviews have provided valuable overviews of EMG-driven control for upper-limb exoskeletons and exosuits, including classifications of MCSs based on high-level control modalities [5], [23], or on signal acquisition, preprocessing, and machine-learning-based decoding methods [24]. However, existing perspectives generally treat the control pipeline as a unified process and do not explicitly separate intention decoding, assistance shaping, and actuator control. As a result, functionally distinct roles may be grouped together, making architectures difficult to compare and hindering systematic design. Table I summarizes the relevant reviews considered in this work, reporting their architectural conceptualization and main topics.

From our critical analysis of MCSs for upper-limb exoskeletons, we propose a three-module functional taxonomy, separating the control architecture into a decoder, which estimates movement intention from sEMG; a shaper, which transforms this estimate into an appropriate assistance command or reference; and a controller¹, which converts this command into actuator actions. Decoder, shaper, and controller address fundamentally different design problems: intention estimation, human-in-the-loop assistance shaping, and low-level control, respectively. This functional separation allows control architectures to be compared independently at the levels of intention estimation, assistance generation, and actuator execution, regardless of the specific algorithms or sensing technologies used to implement them.

This review is structured as a critical synthesis rather than a systematic or historical survey. Instead of seeking exhaustive coverage, we analyze representative contributions that illuminate recurring architectural choices and functional roles within the proposed taxonomy. The objective is to clarify the functional relationships among the roles of the three modules, identify limitations and open challenges, and derive design guidelines and future research directions.

The remainder of the paper is organized as follows. The rest of this section describes the literature search strategy. Section II presents the proposed taxonomy and its motivations. Sections III, IV, and V examine the three modules in detail. Section VI discusses representative examples from the literature within the proposed framework. Section VII provides design guidelines, while Section VIII outlines possible future research directions.

References (100)

Couldn't load all references. Reload the page to try again.