arXiv:2611.03520cs.RONov 2026

Manuscript Offprint

arXiv:2611.03520

PanoTac: A Dense Three-Axis Tactile Sensor for Robust Touch-Centric Manipulation

Binglin, Wang, Xiaole, Jiang, Zicheng Teng, Xinqi Liu, Yunzhu Li, Lerrel Pinto, Zichen Jeff Cui, Binghao Huang

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Binglin (Andre) Wang1,†^{1,\dagger}, Xiaole (Alex) Jiang2,†^{2,\dagger}, Zicheng Teng1^{1}, Xinqi Liu1^{1}, Yunzhu Li3^{3}, Lerrel Pinto1^{1}, Zichen Jeff Cui1,‡^{1,\ddagger}, and Binghao Huang3,‡,∗^{3,\ddagger,*}

1^{1}New York University 2^{2}City University of New York

3^{3}Columbia University

Figure

(i) Test-Tube Preparation

(ii) Grain Scooping

(iii) Salt Pouring

Fig. 1: We propose PanoTac, a low-cost, compliant tactile fingertip for dense three-axis tactile sensing. We showcase PanoTac with three tasks (i) test-tube preparation, where in-hand state helps infer tube orientation and shear feedback helps detect stopper release; (ii) grain scooping, where contact patterns help infer spoon orientation and guide robot–environment interaction; and (iii) salt pouring, where weight cues distinguish filled from empty bottles and inform pouring decisions.

Abstract—Contact-rich manipulation benefits from tactile feedback that captures both detailed contact geometry and interaction forces. When scooping grains, contact patterns help infer spoon orientation, while resistance transmitted through the grasp guides motion. To provide these complementary sensing capabilities, we present PanoTac, a low-cost, compliant tactile fingertip designed for dense three-axis tactile sensing. Each fingertip provides a 12×32×312 \times 32 \times 3 tactile representation, with one normal (z) and two shear (x, y) response components at each taxel. The sensor operates at 60 Hz and costs less than 50 per fingertip. Sensor characterization quantifies response repeatability and consistency across sensor instances and contact locations. We integrate PanoTac into a robotic system with a visuo-tactile pipeline. Across test-tube preparation, grain scooping, and salt pouring, the resulting policies outperform vision-only baselines by an average of 46.7 percentage points. Ablations show that removing either spatial contact information or shear feedback reduces overall performance across the task suite. Our project page is available at https://panotac.github.io.

I. INTRODUCTION

Humans rely on vision and touch to manipulate daily objects, using tactile feedback to understand contact states and determine how an interaction should proceed. Consider inserting a test tube into a rack and removing its stopper (Fig. 1(i)). Vision guides positioning, while contact patterns help infer the tube's in-hand orientation under partial occlusion. Stopper removal requires sensing whether the stopper remains engaged or has come free. Changes in resistance transmitted through the fingers help us decide when to stop wiggling and lift the stopper free. These stages highlight two complementary aspects of touch: spatial contact information helps estimate in-hand object orientation, while shear feedback helps detect changes in interaction state.

These requirements motivate dense three-axis tactile sensing, but realizing this capability in a practical robotic fingertip presents two challenges. (i) Spatial resolution and force sensing. Dense piezoresistive arrays provide detailed responses to normal contact but do not directly capture shear loading [1]–[3]. Magnetic tactile sensors provide responses to

†^{\dagger} Equal contribution.

‡^{\ddagger} Equal advising.

∗^{*} Corresponding author: Binghao Huang.

Email: binghao.huang@columbia.edu.

normal and shear loading [4], [5], but the size and spacing of discrete sensing elements constrain spatial sampling density, making fine contact patterns difficult to resolve directly [6]. (ii) Hardware integration and reproducibility. Optical tactile sensors capture detailed contact geometry and support force estimation, but accommodating the camera and optical path imposes constraints on fingertip packaging and geometry [7]. Practical deployment also requires affordable, compliant hardware with straightforward fabrication [8], repeatable responses, and consistency across independent instances.

To address these challenges, we present PanoTac, a low-cost, compliant tactile fingertip designed for dense three-axis tactile sensing. Our contributions are threefold:

(i) A dense three-axis tactile fingertip. We combine spatial contact information from a dense piezoresistive sensing array [2] with magnetic responses to fingertip deformation [4] on a shared grid. This yields a 12×32×312 \times 32 \times 3 tactile representation per fingertip, with one normal (z) and two shear (x, y) response components at each taxel. We design the magnet arrangement to reduce magnetic cross-talk between opposing fingertips. The fingertip is modular and straightforward to fabricate, with each sensor costing below 50, excluding readout boards. Fabrication requires less than 3 hours of unattended printing and 30 minutes of hands-on assembly.

(ii) Sensor characterization and system integration. We evaluate response repeatability under repeated loading and characterize consistency across sensor instances and contact locations. We integrate PanoTac into a robotic system that conveys tactile information through auditory feedback, enabling operators to adjust actions during data collection.

(iii) Visuo-tactile policy learning and modality analysis. We learn visuo-tactile manipulation policies and evaluate them on test-tube preparation, grain scooping, and salt pouring. The resulting policies achieve an overall success rate of 91.7% across these three tasks, compared with 45.0% for vision-only policies. Through modality ablations, we evaluate the complementary contributions of dense spatial contact information and shear feedback, showing that removing either reduces overall task success.

We describe the sensor design, fabrication, tactile representation, and policy learning pipeline in Sec. III, report hardware characterization in Sec. IV, and present robot learning experiments and modality ablations in Sec. V.

References (42)