Manuscript Offprint

arXiv:2610.41050

Closing the Applied Cybersecurity Gap in Critical Infrastructure: A Cyber-to-Physical Security Assessment Framework for Water Systems

Halil Dursunoglu, Kaan Sulkalar

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Abstract

The integration of information technology and operational technology in water infrastructure creates pathways through which cyber compromise may affect physical service delivery. This study revisits the Applied Cybersecurity Gap (ACG) framework by evaluating an experimental Applied Cybersecurity Gap Index (ACGI) alongside the Cyber-to-Physical Propagation Rate (CPPR), defined as the proportion of initially compromised trials that produce a specified physical-impact outcome. The expanded evaluation comprises 2,160 synthetic trials across three water-network benchmarks, including EPANET Example Network 3 (Net3), and couples declared cyber-attack progression rules with hydraulic simulations. A source-trained machine-learning model evaluated on 247 compromised Net3 trials achieved ROC-AUC 0.772, PR-AUC 0.775, and F1 0.733, compared with 0.661, 0.642, and 0.704 for a scenario-only baseline. The configuration-cluster bootstrap interval for the ROC-AUC difference was 0.038–0.183. A separate 720-run Net3 hydraulic operating-point sensitivity analysis achieved the study's exploratory baseline pressure criterion in all reruns, preserved 717 of 720 physical-impact labels, and produced ROC-AUC 0.791 with the frozen source-trained model. Additional analyses examine the sensitivity of CPPR to the physical-impact threshold and assumed control-blocking probabilities, and demonstrate that the ACGI–CPPR association is partly induced by the simulation design rather than independently validated. The findings establish a reproducible simulation-based assessment workflow, but do not constitute field calibration of cybersecurity-control effectiveness or prediction of real-world utility incidents.

Keywords: Operational technology, Water distribution, Cyber-to-physical propagation, Applied Cybersecurity Gap, Cross-network transfer, WNTR,

*Corresponding author

Email addresses: halilibrahim.dursunoglu@wmich.edu (Halil I. Dursunoglu), kaan.sulkalar@wmich.edu (Kaan Sulkalar)

Hydraulic sensitivity

1. Introduction

Critical infrastructure systems increasingly depend on the integration of information technology (IT), operational technology (OT), communication networks, and automated control mechanisms to maintain essential services. Water distribution infrastructure represents a particularly important example of this integration because its operational continuity directly affects public health, economic activity, emergency response, and community resilience. Modern water utilities employ supervisory control and data acquisition (SCADA) systems, programmable logic controllers (PLCs), remote monitoring devices, and network-connected actuators to regulate pumping operations, storage levels, pressure conditions, and water delivery. Although these technologies improve operational visibility and efficiency, they also introduce cybersecurity dependencies into physical processes that were traditionally managed within more isolated industrial environments.

The convergence of IT and OT creates security challenges that differ from those encountered in conventional enterprise networks. A cybersecurity incident affecting a business application may primarily compromise information confidentiality, integrity, or availability, whereas an incident involving industrial control systems can also alter physical operating conditions. Unauthorized changes to pump commands, controller settings, sensor measurements, or communication pathways may disrupt the coordination between hydraulic infrastructure and its supervisory systems. Depending on the affected assets, operating conditions, and available safeguards, these disruptions may contribute to abnormal pressure, storage-level deviations, equipment stress, or interruptions in service. Consequently, evaluating cybersecurity in water infrastructure requires consideration of both digital compromise and its potential consequences for physical operations. NIST SP 800-82 Revision 3 emphasizes the distinctive performance, reliability, and safety requirements of OT environments and the importance of incorporating these requirements into cybersecurity practices [1].

Cybersecurity frameworks provide established mechanisms for identifying assets, assessing threats, implementing safeguards, and organizing risk-management activities. The NIST Cybersecurity Framework 2.0, for example, establishes high-level cybersecurity outcomes that organizations can use to structure governance and operational improvements [2]. However, the existence of a cybersecurity policy, architectural requirement, or prescribed control does not necessarily demonstrate that the corresponding protection has been fully implemented or remains effective under operational conditions. Differences may arise from legacy equipment, inconsistent access-control enforcement, incomplete network segmentation, delayed maintenance, limited monitoring coverage, or constraints imposed by continuous industrial operations. These differences are particularly consequential in environments where multiple security mechanisms must function together to prevent an initial intrusion from reaching operational assets.

This study examines such differences through the concept of the Applied Cybersecurity Gap (ACG), defined as the discrepancy between intended cybersecurity protection and its implementation within an operational environment. The ACG concept emphasizes the distinction between documenting a security requirement and establishing that the corresponding safeguard is present and operationally meaningful. To support quantitative experimentation, the study uses an Applied Cybersecurity Gap Index (ACGI) that aggregates five normalized dimensions: external exposure, access control, IT/OT segmentation, detection capability, and recovery capability. These dimensions represent different aspects of the protection environment and are modeled as explicit experimental inputs. The index is intended to provide an interpretable representation of security-control implementation gaps rather than replace established vulnerability-scoring systems or serve as an independently validated measure of organizational cyber risk.

A further challenge arises from the distinction between successful initial compromise and the subsequent development of physical consequences. An attacker obtaining access to an exposed digital asset does not necessarily gain control of operational equipment, and reaching an OT component does not necessarily produce a measurable disruption. Network segmentation, access restrictions, controller behavior, process constraints, and hydraulic operating conditions may interrupt or modify the progression of an attack. Conversely, a seemingly limited compromise may have substantial operational implications when it affects an asset with direct influence over the physical process. Treating these stages as a single binary security outcome can obscure the mechanisms through which cybersecurity weaknesses become infrastructure-level consequences.

To examine this progression, the study employs the Cyber-to-Physical Propagation Rate (CPPR), defined as the proportion of initially compromised experimental trials that produce a specified physical-impact outcome. This conditional measure distinguishes the initial compromise event from the subsequent occurrence of measurable physical disruption. In the proposed evaluation, cyber compromise and OT reachability are generated using declared security-dependent simulation rules, while physical-impact outcomes are obtained from hydraulic simulations. The separation of these stages makes the experimental assumptions explicit and permits analysis of how modeled security conditions, attack scenarios, and hydraulic responses contribute to the observed propagation outcomes. CPPR is therefore interpreted as a conditional outcome measure within the simulated environment, not as an empirically established probability of disruption in operational water utilities.

Existing research has provided important foundations for studying cyber-physical security in water infrastructure. Physical and cyber-physical testbeds, including Secure Water Treatment (SWaT) and Water Distribution (WADI), have enabled investigation of attack scenarios, process monitoring, and anomaly detection under controlled experimental conditions [3, 4, 5]. The Battle of the Attack Detection Algorithms (BATADAL) has further supported comparative evaluation of detection methods for water distribution networks [6]. Model-based approaches have investigated the use of hydraulic behavior and residual analysis to identify potentially malicious disturbances [7]. Collectively, these studies demonstrate the importance of incorporating process knowledge into cybersecurity assessment rather than relying exclusively on conventional network-security indicators.

More recent investigations have expanded the application of machine learning, hydraulic models, and digital-twin approaches to cyber-physical water-system security. Parajuli and Shin examined machine-learning-based identification of failure types in cyber-physical water distribution networks [8], while Pandey et al. investigated digital-twin-supported anomaly detection and localization [9]. Raza and Moazeni proposed a framework integrating cyberattack detection, localization, and severity assessment in smart water systems [10]. Homaei et al. explored causal digital twins for anomaly detection in water-related cyber-physical environments [11]. Recent reviews also document the growing diversity of artificial-intelligence-based attack-detection techniques and the challenges associated with evaluating them across heterogeneous water-system datasets [12]. These developments provide a strong methodological foundation, but their principal evaluation targets often concern attack detection, event classification, localization, or severity estimation rather than the conditional prediction of physical impact following an established cyber compromise.

The present research develops an integrated assessment and evaluation framework connecting cybersecurity implementation gaps, simulated attack progression, hydraulic-process responses, and machine-learning prediction. The framework combines explicitly defined security-control variables with six attack-scenario categories and paired baseline-versus-attack hydraulic simulations. It evaluates three network benchmarks, each containing 720 experimental trials. Two synthetic networks, designated A and B, support bidirectional transfer experiments and source-model training, while EPANET Example Network 3 (Net3) provides an additional held-out hydraulic benchmark. Net3 includes 92 junctions, 117 pipes, two pumps, and three storage tanks. Its inclusion enables assessment of physical-impact outcomes in a network with a more detailed hydraulic structure than the simplified representations used in earlier versions of this research.

The contribution of this research is fourfold. First, it formalizes an experimental representation of applied cybersecurity-control gaps and distinguishes this construct from established vulnerability and risk-management measures. Second, it defines a conditional cyber-to-physical propagation outcome that separates initial compromise, OT reachability, and physical-process impact. Third, it implements a reproducible multi-network evaluation protocol combining synthetic security scenarios, WNTR-based hydraulic simulation, source-only machine-learning transfer, feature ablations, and configuration-aware uncertainty estimation. Fourth, it examines the sensitivity of the resulting physical-impact labels and predictive performance to a documented change in the hydraulic operating point. Together, these elements provide an integrated methodology for investigating the relationship between modeled cybersecurity weaknesses and simulated physical consequences in water infrastructure.

References (23)