Manuscript Offprint
arXiv:2610.41127MotorSense: A Video-EMG Dataset of Motoric Representations for Action Understanding
Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.
Abstract
Computer vision models learn hand action only from its visual consequences, without access to the underlying embodied motor signals. We address this absence with MOTORSENSE - the first large-scale paired egocentric video and surface electromyography (EMG) dataset. MOTORSENSE pairs bimanual EMG bands with egocentric video and yields synchronized video, bimanual EMG and IMU, and audio across 100 hours of unscripted manipulation. EMG offers a powerful scalable alternative to manual annotation: it captures finger movement, hand configuration, and the forces exerted between hand and environment as a dense signal free of occlusion and labeler bias, whereas manual annotation is costly, subjective, and unreliable under occlusion. We use MOTORSENSE to learn sensorimotor alignment, producing an organization of action that is shared across the visual and motoric spaces, through cross-modal pre-training between video and EMG. The resultant vision models are then transferred to downstream tasks that benefit from sensorimotor alignment: in this case, action recognition, 3D hand reconstruction, and 3D contact reconstruction. We further demonstrate a generative application in which EMG motor signals are used to condition a video diffusion model, yielding videos of fine-grained hand manipulation. Across four action-centric computer vision tasks and eight popular video datasets, we demonstrate that sensorimotor alignment provides a stronger foundation for visual representation learning than conventional self-supervised learning methods over video, outperforming every baseline across all tasks and datasets evaluated.
1 Introduction
When humans develop motor and perceptual capabilities, they rely not only on perceiving their surroundings and the visual effects of their actions, but more crucially on the internal motor experiences that accompany these percepts. Yet computer vision models are trained almost exclusively on the visual modality, with no direct access to embodied modalities such as muscle activity. Closing this gap requires incorporating such signals: learning from video alone leaves the underlying action structure implicit in a high-dimensional stream of pixels, whereas incorporating embodied signals transforms this hidden structure into an intrinsically lower-dimensional learnable signal. Among embodied signals, those tied to the hands are especially important, as it is through the hands that humans effect change in the physical world.
To make hand-centric embodied signals available to computer vision we introduce MOTORSENSE, a dataset pairing egocentric video with direct measurements of hand motor activity collected via surface electromyography (EMG) — a modality that records the electrical activity of muscles through the skin. See Figure 1 for example sequences. MOTORSENSE captures a dense signal reflecting
40th Conference on Neural Information Processing Systems (NeurIPS 2026).

Figure 1: EMG captures both categorical and continuous structure of hand actions. (Top) For three discrete hand configurations repeated twice—fist, point, and flat—each pose produces a distinct and reproducible EMG signature: fist is marked by a suppressed purple channel (#7) with respect to flat and a pronounced red channel (#1) with respect to point; point exhibits lower overall amplitude, with less purple than flat and less red than fist; flat is distinguished by pronounced purple and red activation. Sharp grey rectangles reflect the boundaries between hand gestures and rest states. (Bottom) A pick-and-lift sequence combines gradual and abrupt transitions: the hand moves smoothly from rest through pregrasp into grasp, changes sharply as force is applied at lift, then settles—non-instantaneously—into a steady hold. The EMG mirrors this structure, with channels quiet at rest, building subtly through pregrasp and grasp, peaking sharply as the lift begins, and stabilizing during hold.
how the entirety of the hand engages with the environment: the forces applied, finger movement, and hand configuration throughout each interaction, fine-grained information difficult to observe directly from vision due in part to occlusion. MOTORSENSE goes beyond force datasets such as FEEL [15], TouchScale [35], and OpenTouch [54] with a richer and denser embodied signal, gathered without the use of hand-mounted sensors which visually and physically obstruct interaction. The direct measurement in MOTORSENSE stands in contrast to labels annotated over video datasets (e.g. EPIC-Kitchens, Ego4D), which 1) require manual annotation effort, 2) require pre-defined ontology design, and 3) suffer from annotation error and imprecision.
MOTORSENSE captures hand motor activity using EMG devices consisting of 8 equally spaced electrodes around the lower forearm (see Figure 2). EMG directly senses the electrical activity produced by muscles through the skin, where different muscles produce distinct activation profiles across the electrode array. EMG signals encode both hand forces [17] and fine-grained, dynamic finger articulation [51]. In addition to EMG, we record IMU streams from the wrist device capturing translational and rotational acceleration of the hand in space, and synchronize these signals with egocentric video.
Our primary use of MOTORSENSE is representation learning through sensorimotor alignment between video and EMG data. We induce this alignment with a CLIP-style contrastive objective that jointly trains a video encoder and an EMG encoder in a shared embedding space, pulling together each video clip and the muscle activity that produced it and pushing apart mismatched pairs; EMG thus acts as a privileged supervisory signal that shapes the video representation during pre-training but is discarded at inference, so the aligned video backbone can be transferred to purely visual downstream tasks. We transfer this backbone to three tasks that emphasize hand–object manipulation: 1) recognizing actions in video; 2) 3D hand reconstruction from images; 3) 3D contact reconstruction from images.
Beyond representation learning, MOTORSENSE also supports a generative application: conditioning an image-to-video (I2V) diffusion model on EMG. This addresses a key limitation of existing control modalities, which cannot specify fine-grained, physically grounded hand actions — language captures high-level activity but is underspecified, keypoint trajectories require annotation and are force-agnostic, and neither captures the fine-grained forces of manipulation. EMG supplies exactly this signal, making generative models more useful for VR/AR, where EMG wearables are already emerging as natural control interfaces [73].
The primary contributions of this work are as follows:
-
Release of the MOTORSENSE dataset: We release the first large-scale paired egocentric video and surface electromyography (EMG) dataset, capturing the muscle activations that cause physical action rather than only their visual effects. MOTORSENSE consists of 100 hours of natural, unscripted hand–object manipulation, recorded with non-obstructive wrist-worn EMG bands paired with egocentric glasses.
-
Sensorimotor alignment for action-centric computer vision: We demonstrate that aligning a video encoder with bimanual EMG data through a CLIP-style contrastive objective is a powerful self-supervised pre-training approach, yielding large and consistent gains over a variety of visual-only pre-training methods.
-
Motor-code conditioning for fine-grained control of video diffusion: We learn motor codes, a discrete VQ-VAE representation of EMG discovered without manual labels, and use them as conditioning inputs to an image-to-video diffusion model. This allows for video generation responsive to fine-grained hand activity, and improves generation fidelity for hand–object interaction.
Multimodal Signals for Action Understanding in Video. We organize prior work along the three downstream applications we target with MOTORSENSE: action recognition, 3D hand-object reconstruction, and video diffusion. For action understanding, non-visual signals shown to carry transferable structure include language [48, 72, 62], audio [43, 1], head- and body-mounted IMU [42, 69, 8], 3D body and hand pose [56, 52], and contact force [15, 54, 74]; we instead leverage EMG to capture the muscle activity underlying manipulation directly. For 3D hand-object reconstruction, prior work is almost exclusively visual—monocular RGB [46, 47, 19] or depth/RGB-D [68, 9, 24, 67]—with rare audio-based exceptions generating contact sounds from trajectories [16] or recovering pose and per-vertex contact from wearable microphones [40]; EMG offers an automatic, occlusion-free measurement of finger configuration and contact. For video diffusion, existing conditioning signals—language [66, 33, 60], keypoints [71, 36, 23], and audio [75]—each fall short for contact-rich manipulation: language is semantically underspecified, keypoints are noisy near contact and force-agnostic, and audio reflects scene acoustics rather than motor activity. EMG supplies the fine-grained, force-aware control these modalities lack.
Understanding Hands in Video. Large-scale egocentric datasets [10, 27, 28] and contact annotations [11] provide hand-object supervision but rely on coarse, costly manual labels. Multi-view capture rigs [29, 7, 34, 38, 20, 44, 3] recover high-fidelity pose but leave contact forces unobserved and depend on laboratory infrastructure that limits in-the-wild collection. Sensorized gloves [15, 54, 13] record kinematics, contacts, and applied force directly, but obstruct natural hand use. Consumer-grade surface EMG and FMG wristbands [6, 53, 51, 32] sidestep this trade-off, capturing finger movement, hand configuration, and exerted forces in unconstrained settings at a scale lab setups cannot match.
3 Methods
This section presents the components that together define MOTORSENSE and the learning framework built on top of it. We first describe the data collection setup, which pairs bimanual surface EMG and IMU with synchronized egocentric video from glasses (Section 3.1). We then present our primary use of the dataset, sensorimotor alignment, or the alignment of visual embeddings and EMG motor embeddings, resulting in unimodal vision networks that produce representations that are reflective of the fine-grained motor structure of manipulation (Section 3.2). Separately, for our generative application, we introduce motor codes — a discrete mid-level representation of EMG learned directly from the raw signal via a VQ-VAE, with no manual action labels (see Appendix for details) — and use them as conditioning inputs for an image-to-video diffusion model, providing a fine-grained, muscle-derived control signal that existing modalities such as language and keypoints cannot supply (Section 3.3). For a depiction of the contrastive pre-training pipeline and the downstream tasks, see Figure 3.
3.1 Dataset Collection
MOTORSENSE pairs bimanual surface EMG with egocentric video in a wearable, non-obstructive setup that captures natural hand–object manipulation. We collect data in kitchen environments, which provide a broad range of object interaction and action types. For details on dataset statistics and dataset collection procedures pertaining to the data recorded by Aria glasses and the data processing of both vision and EMG streams, see Section 6.2 within the Appendix.
EMG To capture forearm muscle activity during manipulation, we use the MindRove Armband. Two wireless surface EMG devices are worn just slightly above the wrists. See Figure 2 for a picture of the EMG. The armband provides 8 EMG channels arranged equidistantly in a circular configuration around the forearm, with two additional bias and reference channels, using dry stainless-

Figure 2: The bimanual EMG sensing setup of MOTORS-ENSE. Middle: the MindRove Armband used for data collection, worn on the left and right wrists (top and bottom row, respectively), with colored dots marking the electrode sensors equidistantly arranged around the band. Right: cross-sectional anatomy of the lower forearm with each electrode overlaid. Left: example 8-channel EMG recordings from the left and right wristbands gathered during a manipulation task primarily involving the right hand; each colored trace corresponds to one electrode.
steel electrodes that eliminate the need for conductive gel or skin preparation. Signals are sampled at 500 Hz with 24-bit resolution and streamed over Wi-Fi to the recording workstation. The device also includes an integrated 6-axis IMU (3-axis accelerometer and 3-axis gyroscope) sampled at 50 Hz, which we retain as an auxiliary wrist motion signal aligned to the EMG stream. The circumferential electrode layout provides broad coverage of both the flexor and extensor compartments, capturing activity from the muscle groups most relevant to grasping, finger flexion/extension, and wrist articulation during object manipulation.
3.2 Sensorimotor Alignment through CLIP-Style Pretraining
EMG provides a dense, occlusion-free measurement of the motor activity underlying hand action. A natural question is whether a visual encoder can be shaped by this signal to become sensitive to the fine-grained motor structure of manipulation, and whether the learned representations transfer to action-centric vision tasks. We pursue this through sensorimotor alignment, jointly training visual

A) Sensorimotor Alignment
B) Downstream Tasks
Figure 3: Overview of MOTORSENSE. (A) Sensorimotor Alignment. Windows 1, ..., N of bimanual EMG (left) and egocentric video (right) are embedded by an EMG encoder and a video encoder and aligned with a symmetric contrastive objective (Section 3.2): the video and EMG embeddings of the same window (, ) are pulled together, while embeddings from different windows are pushed apart. (B) Downstream Tasks. The learned representations are used for downstream tasks: 1) video diffusion consisting of a single reference frame as input along with EMG control signals, 2) action recognition, 3) 3D hand-object Reconstruction, 4) 3D hand contact prediction.
and EMG encoders to embed windows of egocentric RGB video and bimanual EMG + IMU into a shared representation space. Following CLIP-style cross-modal pre-training, EMG serves as a privileged supervisory signal available only during pre-training. After alignment, the visual encoder is transferred independently to downstream action-centric vision tasks, without requiring EMG at inference.
Vision Tower A vision backbone encodes the clip, over which we perform spatial pooling (for video networks we do not perform temporal pooling, which we find to be a crucial design choice in Section 6.4). See Appendix for details.
EMG Tower The EMG tower is a temporal convolutional-recurrent network. The early stages consist of strided 1D convolutions, followed by residual depthwise-convolution blocks and an LSTM model for encoding of temporal structure. The EMG input is padded with 1 second of context around the video window. IMU is encoded by a second tower of the same design and aligned to video with its own contrastive term. See Appendix for details.
Objective and Loss Because EMG signals exhibit recording-specific biases, we construct each training batch by sampling windows from the same recording. Without this constraint, the visual encoder can minimize the contrastive loss by identifying recording sessions rather than learning action-relevant features (see Appendix for details). As in CLIP, visual and EMG embeddings are -normalized and compared by cosine similarity, scaled by a learnable temperature (a learned logit scale). We minimize the symmetric InfoNCE (CLIP-style) loss
where and are cross-entropy losses over the vision-to-EMG and EMG-to-vision similarity matrices respectively, each taking the matched pair on the diagonal as the target.
Transfer After pre-training, we discard the EMG tower, retain the vision backbone, attach task-specific layers (a classification head for action recognition, and regression heads for 3D hand reconstruction and 3D contact reconstruction), and fine-tune on the downstream tasks (Section 4.1).
3.3 Video Diffusion Conditioned on Motor Codes
For our generative application, motor codes serve as conditioning inputs to a generative video model. We first learn the motor codes directly from raw EMG + IMU data. Given a multichannel EMG +

Figure 4: Self-supervised sensorimotor alignment organizes video and EMG by hand action. (a) t-SNE plot of the joint embedding space for video (green) and EMG (purple) derived from the two towers of our self-supervised contrastive model (Section 3.2). A "modality gap" is observed [37] between video and EMG clusters. (b) The clips associated with each pair: the video query (left) and the clip whose EMG was retrieved (right). Each retrieved clip performs the query's hand action—cutting, mixing in a bowl, drying—with a different object, scene, and recording. (c) The EMG embeddings of (a), coloured by verb with marker shape denoting the object. Despite the network never being trained over these labels, windows of the same action form compact regions (e.g. mix salad, scrape bowl) and verbs group together (the cut family in red). Best viewed zoomed-in and in colour.
IMU window, we train an encoder–quantizer–decoder model that follows a VQ-VAE design and maps the window to a sequence of discrete tokens, each indexing into a shared learned codebook; this token sequence is the motor-code representation of the window. The model is trained with a standard VQ-VAE objective combining a reconstruction loss on the input window with a latent commitment penalty that pulls the encoder's continuous outputs toward their assigned codebook entries. For full implementation details, including model architecture, see Section 6.3.1 of the Appendix.
We consider an image-to-video (I2V) task: given a single reference frame and a sequence of motor codes, predict the subsequent video clip. Rather than fully fine-tuning a large video diffusion backbone on paired video–motor-code data, which would be prohibitively expensive, we leverage Video2LoRA [63], a lightweight approach for controlling video diffusion networks, repurposed to make use of our motor codes as a novel control modality.
Problem Setup Each training sample is a tuple of a reference frame (the first frame of a clip) and a pair of bimanual motor-code sequences extracted from the VQ-VAE spanning the clip duration.
HyperNetwork-Predicted Lightweight LoRA We follow the LightLoRA design of Video2LoRA [63]: the encoded motor-code sequence is fed to a HyperNetwork, which outputs, in a single forward pass, a bank of sample-specific prediction matrices — one pair per controlled linear layer in the diffusion backbone. We refer the reader to [63] for the full details, including the exact factorization and the iterative refinement procedure used by the HyperNetwork. The only trainable components are a learned motor-code embedding network, a HyperNetwork that maps encoded motor codes to adapter weights, and the low-rank adapters inserted into the video diffusion backbone.
| Pre-training | EPIC-Kitchens-100 | SSv2 | Ego-Exo4D | MOTORSENSE | |||
|---|---|---|---|---|---|---|---|
| Verb | Noun | Action | Action | Keystep | Action | ||
| Frozen | None (K400-MAE init.) | 43.85 | 17.74 | 9.93 | 29.17 | 17.72 | 16.86 |
| ρSimCLR | 43.99 | 24.73 | 13.79 | 24.42 | 27.82 | 20.31 | |
| ρMoCo | 42.84 | 23.67 | 13.02 | 22.87 | 26.89 | 18.83 | |
| ρBYOL | 38.50 | 15.64 | 6.58 | 20.21 | 18.05 | 8.68 | |
| Ours | 59.85 | 29.79 | 21.29 | 33.57 | 36.11 | 35.02 | |
| Δ vs. best baseline | +15.86 | +5.06 | +7.50 | +4.40 | +8.29 | +14.71 | |
| End-to-end | None (K400-MAE init.) | 70.42 | 50.01 | 40.06 | 67.57 | 45.82 | 42.22 |
| ρSimCLR | 70.41 | 51.99 | 41.58 | 65.82† | 49.48 | 42.83 | |
| ρMoCo | 70.35 | 52.16 | 41.85 | 65.36† | 48.72 | 42.71 | |
| ρBYOL | 70.12 | 50.48 | 40.83 | 65.15† | 46.13 | 39.51 | |
| Ours | 74.09 | 52.25 | 43.81 | 68.76 | 51.47 | 47.51 | |
| Δ vs. best baseline | +3.67 | +0.09 | +1.96 | +1.19 | +1.99 | +4.68 | |
Table 1: Action recognition results across benchmarks. Top-1 accuracy (%) with the backbone frozen (top) or fine-tuned end-to-end (bottom) on EPIC-Kitchens-100 [10], Something-Something v2 [26], Ego-Exo4D [28], and an annotated subset of MOTORSENSE. All rows use a Hiera-B backbone initialized from K400-MAE [50]; ρSimCLR, ρMoCo, and ρBYOL [22] are pre-trained on the same MOTORSENSE recordings with RGB-only objectives. Best result per column in bold; Δ rows give our margin over the best baseline.
4 Experiments
Here we present experiments performed over MOTORSENSE. We first evaluate sensorimotor alignment learning of image and video backbones, and transfer the resulting representations to three downstream task families (Section 4.1) chosen for their emphasis on hand–object manipulation: action recognition on Something-Something v2 [26], EPIC-Kitchens-100 [10], Ego-Exo4D [28], and MOTORSENSE; 3D hand reconstruction on ARCTIC [20], H2O [34], and HOT3D [3]; and 3D hand contact on MOTORSENSE. Finally, we evaluate motor codes as a conditioning signal for a video diffusion model (Section 4.3), comparing performance against an unconditioned image-to-video backbone and a language conditioning baseline derived procedurally from the raw EMG and IMU streams. We also analyze the sensorimotor embedding space (Section 4.2).
4.1 Cross-Modal Pre-training for Downstream Tasks
We pre-train video and image networks via cross-modal (video–EMG) contrastive alignment. For full pre-training implementation details, see Section 6.3.3 within the Appendix. To evaluate whether the aligned backbone captures representations useful for physical action understanding, we fine-tune it over related downstream tasks. The projection heads are discarded and replaced with task-specific layers (a classification head for action recognition, and regression heads for 3D hand reconstruction and contact reconstruction).
Action Recognition. Table 1 reports top-1 accuracy of different pre-training methods on action recognition. We fine-tune the contrastively pre-trained backbone on four downstream datasets chosen for their emphasis on hand–object manipulation: EPIC-Kitchens-100 [10], Something-Something v2 [26], Ego-Exo4D [28], and a verb–noun annotated subset of MOTORSENSE. For EPIC-Kitchens-100 we report verb, noun, and action accuracy; for the remaining datasets we report a single action-level metric. The projection heads of Section 3.2 are discarded and replaced with a linear classification head, which is trained either with the backbone frozen or end-to-end. All models use a Hiera-B backbone initialized from the MAE-K400 weights released with Hiera [50]. We compare against these weights directly, and against ρSimCLR, ρMoCo, and ρBYOL [22] pre-trained on the same MOTORSENSE recordings and hand crops with RGB-only objectives, so that the comparison isolates the contribution of the EMG signal from that of additional in-domain video. Sensorimotor
| Pre-training | ARCTIC | H2O | HOT3D | |||
|---|---|---|---|---|---|---|
| MPJPE ↓ | A-MPJPE ↓ | MPJPE ↓ | A-MPJPE ↓ | MPJPE ↓ | A-MPJPE ↓ | |
| Default | 24.29† | 38.77† | 24.28 | 51.20 | 30.85† | 54.58† |
| MOTORSENSE (ours) | 21.71 | 35.97 | 19.65 | 44.04 | 28.39† | 48.85† |
| Δ | -2.58 | -2.80 | -4.63 | -7.16 | -2.46 | -5.73 |
Table 2: 3D hand reconstruction. Mean per-joint position error (mm; lower is better) relative to the hand root (MPJPE) and in camera coordinates without root alignment (A-MPJPE) on ARCTIC [20], H2O [34], and HOT3D [3], using a hand-only ArcticNet-SF [20] with a ResNet-50 backbone initialized from ImageNet alone or after sensorimotor alignment on MOTORSENSE. Δ is the change in error from our pre-training.
alignment outperforms every baseline on every benchmark, with the largest gains in the frozen setting. For ablations, see Section 6.4 in the Appendix.
3D Hand Reconstruction. We assess whether cross-modal pre-training improves recovery of fine-grained 3D hand geometry from egocentric video. Table 2 reports results on three egocentric benchmarks: the head-mounted view of ARCTIC [20], H2O [34], and HOT3D [3]. We train a hand-only variant of ArcticNet-SF [20] (object branch removed) separately on each dataset with a ResNet-50 backbone, and compare initializing the backbone from ImageNet against our MOTORSENSE pre-trained ResNet-50. All runs share the same architecture and training schedule; only the backbone initialization differs.
Hand Contact Reconstruction. We next test whether cross-modal pre-training improves prediction of where the hand is in contact with its environment, information that EMG encodes directly through the forces exerted during manipulation. Table 3 reports results on the contact-annotated subset of MOTORSENSE (Section 6.2), where the task is to predict, from a crop around one hand, which vertices are in contact, or that the hand is not in contact at all. We compare against training from ImageNet initialization and from scratch, and three image-level self-supervised methods learned over MOTORSENSE videos, PixPro [65], DenseCL [61], and PeCLR [55]. All methods use a ResNet-50 backbone; we report per-vertex IoU and contact-detection AP, averaged over three seeds.
4.2 Analysis of the Sensorimotor Embedding Space
We next examine whether sensorimotor alignment (Section 3.2) organizes video and EMG by hand action, with no action labels used during pre-training. We sample annotated windows from the MOTORSENSE recordings, keeping those that lie within a single annotated action and contain a visible hand. We then encode the video clip and the bimanual EMG of each window with the two towers of the final pre-trained model. We embed the -normalized video and EMG embeddings of these windows together with t-SNE [39]. For panel (b), we pair video queries with their most similar EMG embedding by cosine similarity. The verb–noun annotations are used only to colour the projection; they play no role in pre-training or in computing the embeddings.
Figure 4 shows the result. Video and EMG form two separate clusters, the “modality gap” typical of contrastively aligned encoders [37], yet cross-modal nearest neighbours still match by hand action: each video query in panel (b) retrieves EMG from a different recording that performs the same action, despite differences in object, scene, and participant. Within the EMG cluster (panel (c),

Figure 5: Qualitative results on ARCTIC [20] for 3D hand-object reconstruction. Each row shows the RGB input, reconstructions from a vision backbone trained without EMG and with EMG (MOTORSENSE pre-training), and ground truth. Incorporating EMG during pre-training yields 3D hands and objects that more closely match the ground truth.
| Conditioning | Trainable Params | FVD ↓ | LPIPS ↓ | PSNR ↑ |
|---|---|---|---|---|
| CogVideoX-5B-I2V (supervised) | 5.57B | 772 | 0.35 | 17.3 |
| CogVideoX-5B-I2V (zero-shot) | 0 | 926 | 0.36 | 17.4 |
| + language conditioning | 0 | 935 | 0.41 | 18.0 |
| + video history | 250M | 373 | 0.30 | 22.0 |
| Ours | 50M | 304 | 0.27 | 22.5 |
Table 4: Image-to-video generation on held-out MOTORSENSE recordings. All methods other than the top row share the same frozen video diffusion backbone and differ only in their conditioning signal and the trainable HyperNetwork/LoRA parameters. Evaluation is performed over a bounding box produced by Aria MPS [18] (applied jointly to generated and original images). Best results are shown in bold.
where a subset of actions is coloured by verb, with marker shape denoting the object), windows of the same action form compact regions, and actions that share a verb lie near one another (e.g. the cut family), even though the model was never exposed to these labels.
4.3 Motor Codes as a Control Signal for Video Diffusion
Table 4 illustrates the results of different training and conditioning methods for video diffusion. Our method conditions on the discrete motor codes through a HyperNetwork-predicted LoRA. We compare against four baselines. Zero-shot I2V and supervised I2V receive only the reference frame, with the supervised variant additionally fine-tuned on MOTORSENSE videos; together they ablate the contribution of motor-code conditioning. The text-prompt baseline procedurally converts the raw EMG/IMU streams into a natural-language description that is fed as conditioning to the diffusion model, evaluating an alternative representation of the same underlying signal. The video-history baseline replaces motor codes with a history of frames as input to the HyperNetwork-predicted LoRA, isolating the value of motor codes against a purely visual context. To assess visual fidelity we report Fréchet Video Distance (FVD) [58], along with per-frame LPIPS [70] and PSNR. All metrics are computed on a bounding box centered around the hands rather than the full image, since the manipulation region is where conditioning differences are most visible. For qualitative visualizations of generated videos as well as full implementation details, see Section 6.3.2 within the Appendix.
| Pre-training | IoU (%) ↑ | AUROC (%) ↑ |
|---|---|---|
| ImageNet [14] | 48.41 ± 0.76 | 92.08 ± 0.17 |
| DenseCL [61] | 48.56 ± 0.91 | 91.27 ± 0.29 |
| PeCLR [55] | 48.30 ± 0.56 | 91.71 ± 0.52 |
| PixPro [65] | 50.59 ± 0.66 | 93.36 ± 0.25 |
| Ours | 55.20 ± 0.62 | 97.19 ± 0.15 |
| Δ vs. best baseline | +4.61 | +3.83 |
Table 3: Hand contact reconstruction on MOTORSENSE. IoU (%) between predicted and annotated contact regions on hands in contact, and AUROC (%) for detecting whether a hand is in contact; mean ± std over three seeds. Best in bold; Δ is our margin over the best baseline.
5 Discussion
Sensorimotor alignment directly encodes action structure. The t-SNE projection in Figure 4 reveals that sensorimotor alignment organizes both video and EMG by action, despite being learned without manual labels. Windows of actions such as mix salad and scrape bowl form compact, cleanly separated regions, and actions sharing a verb but differing in object (e.g., cut) sit close together in the embedding space. The downstream results further demonstrate this: the largest action-recognition gains appear under frozen evaluation (+15.9 verb accuracy on EPIC-Kitchens-100, +14.7 on MOTORSENSE).
The gains come from EMG, rather than additional in-domain video. Matched RGB-only baselines trained on the same recordings isolate the contribution of EMG supervision from that of additional in-domain video. For action recognition, , , and yield inconsistent gains and often fall below the K400-MAE initialization (e.g., on SSV2), whereas our sensorimotor alignment learning outperforms every baseline on all four benchmarks (Table 1). The same pattern holds at the image level: DenseCL [61], PeCLR [55], and PixPro [65] trained on MOTORSENSE frames offer at most marginal gains over ImageNet on contact reconstruction, while our model improves IoU by +4.6 and AUROC by +3.8 over the best of them (Table 3).
EMG captures hand articulation and contact information. Because EMG measures finger articulation and exerted force while being robust to visual occlusion, we expect its largest benefit on tasks where hands are partially occluded by the objects they manipulate. Pre-training lowers joint error on all three 3D hand reconstruction benchmarks, most notably on H2O (-4.6 mm MPJPE, -7.2 mm A-MPJPE; Table 2, Figure 5), and yields the contact-reconstruction improvements above, consistent with EMG directly encoding the forces exerted at contact.
Motor codes are an effective control signal for generation. In image-to-video generation (Table 4), the zero-shot backbone performs poorly and language conditioning adds little, confirming that text under-specifies fine-grained manipulation. Both Video2LoRA-based variants [63] outperform full supervised fine-tuning, and motor-code conditioning yields the highest fidelity for hand–object interaction, with the qualitative differences (correct stirring vs. scooping, spreading vs. rotating, finger placement on the avocado) shown in Figures 7–9.
Limitations. Our setup uses an 8-channel consumer-grade EMG band; while sufficient to demonstrate the value of aligning vision with EMG, higher-density bands (16 channels in commercial devices, upwards of 128 in research systems [57]) would provide a richer signal as such hardware becomes more accessible.
Broader Impact. As wearable EMG matures into a mainstream input modality, associated datasets and methods become increasingly impactful—supporting applications from VR/AR and personalized CGI to robot understanding of human collaborators, to high-stakes domains such as surgical training where virtual practice can ease reliance on scarce resources like cadavers. More broadly, motor-grounded representations open a path toward modeling hand action across diverse bodies and motor abilities, with implications for assistive and rehabilitative technologies.
References
[1] Alwassel, H., Heilbron, F.C., Ghanem, B.: Action search: Spotting actions in videos and its application to temporal action localization. In: Proceedings of the European Conference on Computer Vision (ECCV). pp. 251–266 (2018)
[2] Atzori, M., Gijsberts, A., Castellini, C., Caputo, B., Hager, A.G.M., Elsig, S., Giatsidis, G., Bassetto, F., Müller, H.: Electromyography data for non-invasive naturally-controlled robotic hand prostheses. Scientific Data 1, 140053 (2014). https://doi.org/10.1038/sdata.2014.53
[3] Banerjee, P., Shkodrani, S., Moulon, P., Hampali, S., Han, S., Zhang, F., Zhang, L., Fountain, J., Miller, E., Basol, S., et al.: Hot3d: Hand and object tracking in 3d from egocentric multi-view videos. In: Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition. pp. 7061–7071 (2025)
[4] Batzianoulis, I., El-Khoury, S., Pirondini, E., Coscia, M., Micera, S., Billard, A.: Emg-based decoding of grasp gestures in reaching-to-grasping motions. Robotics and Autonomous Systems 91, 59–70 (2017). https://doi.org/10.1016/j.robot.2016.12.014
[5] Castellini, C., Koiva, R.: Using surface electromyography to predict single finger forces. In: 2012 4th IEEE RAS and EMBS International Conference on Biomedical Robotics and Biomechatronics. pp. 1266–1272 (2012). https://doi.org/10.1109/BioRob.2012.6290294
[6] Castellini, C., Van Der Smagt, P.: Surface emg in advanced hand prosthetics. Biological cybernetics 100(1), 35–47 (2009)
[7] Chao, Y.W., Yang, W., Xiang, Y., Molchanov, P., Handa, A., Tremblay, J., Narang, Y.S., Van Wyk, K., Iqbal, U., Birchfield, S., Kautz, J., Fox, D.: DexYCB: A benchmark for capturing hand grasping of objects. In: CVPR (2021)
[8] Chen, B., Wongso, W., Li, Z., Khaokaew, Y., Xue, H., Salim, F.: Comodo: Cross-modal video-to-imu distillation for efficient egocentric human activity recognition. arXiv preprint arXiv:2503.07259 (2025)
[9] Chen, J., Yan, M., Zhang, J., Xu, Y., Li, X., Weng, Y., Yi, L., Song, S., Wang, H.: Tracking and reconstructing hand object interactions from point cloud sequences in the wild. In: Proceedings of the AAAI conference on artificial intelligence. vol. 37, pp. 304–312 (2023)
[10] Damen, D., Doughty, H., Farinella, G.M., Fidler, S., Furnari, A., Kazakos, E., Moltisanti, D., Munro, J., Perrett, T., Price, W., et al.: Scaling egocentric vision: The epic-kitchens dataset. In: Proceedings of the European conference on computer vision (ECCV). pp. 720–736 (2018)
[11] Darkhalil, A., Shan, D., Zhu, B., Ma, J., Kar, A., Higgins, R., Fidler, S., Fouhey, D., Damen, D.: Epic-kitchens visor benchmark: Video segmentations and object relations. Advances in Neural Information Processing Systems 35, 13745–13758 (2022)
[12] De Luca, C.J.: The use of surface electromyography in biomechanics. Journal of applied biomechanics 13(2), 135–163 (1997)
[13] DelPreto, J., Liu, C., Luo, Y., Foshey, M., Li, Y., Torralba, A., Matusik, W., Rus, D.: Actionsense: A multimodal dataset and recording framework for human activities using wearable sensors in a kitchen environment. Advances in Neural Information Processing Systems 35, 13800–13813 (2022)
[14] Deng, J., Dong, W., Socher, R., Li, L.J., Li, K., Fei-Fei, L.: Imagenet: A large-scale hierarchical image database. In: 2009 IEEE conference on computer vision and pattern recognition. pp. 248–255. Ieee (2009)
[15] Dessalene, E., He, B., Maynord, M., Tussa, Y., Mantripragada, P., Karabati, Y., Roy, N., Aloimonos, Y.: Feel (force-enhanced egocentric learning): A dataset for physical action understanding. arXiv preprint arXiv:2603.15847 (2026)
[16] Dou, Y., Oh, W., Luo, Y., Loquercio, A., Owens, A.: Hearing hands: Generating sounds from physical interactions in 3d scenes. In: Proceedings of the Computer Vision and Pattern Recognition Conference. pp. 1795–1804 (2025)
[17] Duque, J., Masset, D., Malchaire, J.: Evaluation of handgrip force from emg measurements. Applied ergonomics 26(1), 61–66 (1995)
[18] Engel, J., Somasundaram, K., Goesele, M., Sun, A., Gamino, A., Turner, A., Talattof, A., Yuan, A., Souti, B., Meredith, B., et al.: Project aria: A new tool for egocentric multi-modal ai research. arXiv preprint arXiv:2308.13561 (2023)
[19] Fan, Z., Parelli, M., Kadoglou, M.E., Chen, X., Kocabas, M., Black, M.J., Hilliges, O.: Hold: Category-agnostic 3d reconstruction of interacting hands and objects from video. In: Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition. pp. 494–504 (2024)
[20] Fan, Z., Taheri, O., Tzionas, D., Kocabas, M., Kaufmann, M., Black, M.J., Hilliges, O.: Arctic: A dataset for dexterous bimanual hand-object manipulation. In: Proceedings of the IEEE/CVF conference on computer vision and pattern recognition. pp. 12943–12954 (2023)
[21] Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., Aszmann, O.C.: The extraction of neural information from the surface emg for the control of upper-limb prostheses: emerging avenues and challenges. IEEE transactions on neural systems and rehabilitation engineering 22(4), 797–809 (2014)
[22] Feichtenhofer, C., Fan, H., Xiong, B., Girshick, R., He, K.: A large-scale study on unsupervised spatiotemporal representation learning. In: 2021 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR). pp. 3298–3308. IEEE (2021)
[23] Gan, Q., Ren, Y., Zhang, C., Ye, Z., Xie, P., Yin, X., Yuan, Z., Peng, B., Zhu, J.: Humandit: Pose-guided diffusion transformer for long-form human motion video generation. arXiv preprint arXiv:2502.04847 (2025)
[24] Garcia-Hernando, G., Yuan, S., Baek, S., Kim, T.K.: First-person hand action benchmark with rgb-d videos and 3d hand pose annotations. In: Proceedings of the IEEE conference on computer vision and pattern recognition. pp. 409–419 (2018)
[25] Geng, W., Du, Y., Jin, W., Wei, W., Hu, Y., Li, J.: Gesture recognition by instantaneous surface emg images. Scientific reports 6(1), 36571 (2016)
[26] Goyal, R., Kahou, S.E., Michalski, V., Materzynska, J., Westphal, S., Kim, H., Haenel, V., Fruend, I., Yianilos, P., Mueller-Freitag, M., et al.: The “something something” video database for learning and evaluating visual common sense. In: 2017 IEEE international conference on computer vision (ICCV). pp. 5843–5851. IEEE (2017)
[27] Grauman, K., Westbury, A., Byrne, E., Chavis, Z., Furnari, A., Girdhar, R., Hamburger, J., Jiang, H., Liu, M., Liu, X., et al.: Ego4d: Around the world in 3,000 hours of egocentric video. In: Proceedings of the IEEE/CVF conference on computer vision and pattern recognition. pp. 18995–19012 (2022)
[28] Grauman, K., et al.: Ego-Exo4D: Understanding skilled human activity from first- and third-person perspectives. In: CVPR (2024)
[29] Hampali, S., Sarkar, S.D., Lepetit, V.: Ho-3d_v3: Improving the accuracy of hand-object annotations of the ho-3d dataset. arXiv preprint arXiv:2107.00887 (2021)
[30] He, B., Wang, Z., Kuang, L., Ghosh, I., Malik, J., Fermuller, C., Wu, T., Mao, J., Liu, R., Qi, H., et al.: Forceband: Learning forceful manipulation with semg. arXiv preprint arXiv:2606.26093 (2026)
[31] Kaifosh, P., Reardon, T.R.: A generic non-invasive neuromotor interface for human-computer interaction. Nature 645(8081), 702–711 (2025)
[32] Kolev, S., Ma, L., Goesele, M., De Nardi, R., Engel, J., Newcombe, R.: Beyond gestures: Estimating full hand pose and contact forces from wrist-worn pressure sensor array. arXiv preprint arXiv:2609.16518 (2026)
[33] Kong, W., Tian, Q., Zhang, Z., Min, R., Dai, Z., Zhou, J., Xiong, J., Li, X., Wu, B., Zhang, J., et al.: Hunyuanvideo: A systematic framework for large video generative models. arXiv preprint arXiv:2412.03603 (2024)
[34] Kwon, T., Tekin, B., Stühmer, J., Bogo, F., Pollefeys, M.: H2O: Two hands manipulating objects for first person interaction recognition. In: ICCV (2021)
[35] Li, D., Wang, H., Yang, Q., Zhu, Z., Fang, H., Zeng, Z., Han, Y., Wang, Z., Wang, Y., Huang, B., et al.: Touchscale: 500 hours of human vision and touch for visual-tactile learning. arXiv preprint arXiv:2610.10288 (2026)
[36] Li, H., Li, Y., Yang, Y., Cao, J., Zhu, Z., Cheng, X., Chen, L.: Dispose: Disentangling pose guidance for controllable human image animation. arXiv preprint arXiv:2412.09349 (2024)
[37] Liang, V.W., Zhang, Y., Kwon, Y., Yeung, S., Zou, J.Y.: Mind the gap: Understanding the modality gap in multi-modal contrastive representation learning. Advances in neural information processing systems 35, 17612–17625 (2022)
[38] Liu, Y., Liu, Y., Jiang, C., Lyu, K., Wan, W., Shen, H., Liang, B., Fu, Z., Wang, H., Yi, L.: Hoi4d: A 4d egocentric dataset for category-level human-object interaction. In: Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition. pp. 21013–21022 (2022)
[39] Van der Maaten, L., Hinton, G.: Visualizing data using t-sne. Journal of machine learning research 9(11) (2008)
[40] Mao, Y., Yoo, U., Yao, Y., Syed, S.N., Bondi, L., Francis, J., Oh, J., Ichnowski, J.: Visuo-acoustic hand pose and contact estimation. arXiv preprint arXiv:2508.00852 (2025)
[41] Merletti, R., Parker, P.J.: Electromyography: physiology, engineering, and non-invasive applications. John Wiley & Sons (2004)
[42] Moon, S., Madotto, A., Lin, Z., Saraf, A., Bearman, A., Damavandi, B.: Imu2clip: language-grounded motion sensor translation with multimodal contrastive learning. In: Findings of the Association for Computational Linguistics: EMNLP 2023. pp. 13246–13253 (2023)
[43] Morgado, P., Vasconcelos, N., Misra, I.: Audio-visual instance discrimination with cross-modal agreement. In: Proceedings of the IEEE/CVF conference on computer vision and pattern recognition. pp. 12475–12486 (2021)
[44] Ohkawa, T., He, K., Sener, F., Hodan, T., Tran, L., Keskin, C.: Assemblyhands: Towards egocentric activity understanding via 3d hand pose estimation. In: Proceedings of the IEEE/CVF conference on computer vision and pattern recognition. pp. 12999–13008 (2023)
[45] Oord, A.v.d., Dieleman, S., Zen, H., Simonyan, K., Vinyals, O., Graves, A., Kalchbrenner, N., Senior, A., Kavukcuoglu, K.: Wavenet: A generative model for raw audio. arXiv preprint arXiv:1609.03499 (2016)
[46] Pavlakos, G., Shan, D., Radosavovic, I., Kanazawa, A., Fouhey, D., Malik, J.: Reconstructing hands in 3d with transformers. In: Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition. pp. 9826–9836 (2024)
[47] Potamias, R.A., Zhang, J., Deng, J., Zafeiriou, S.: Wilor: End-to-end 3d hand localization and reconstruction in-the-wild. In: Proceedings of the Computer Vision and Pattern Recognition Conference. pp. 12242–12254 (2025)
[48] Pramanick, S., Song, Y., Nag, S., Lin, K.Q., Shah, H., Shou, M.Z., Chellappa, R., Zhang, P.: Egovlpv2: Egocentric video-language pre-training with fusion in the backbone. In: Proceedings of the IEEE/CVF International Conference on Computer Vision. pp. 5285–5297 (2023)
[49] Ragusa, F., Furnari, A., Livatino, S., Farinella, G.M.: The meccano dataset: Understanding human-object interactions from egocentric videos in an industrial-like domain. In: Proceedings of the IEEE/CVF Winter Conference on Applications of Computer Vision. pp. 1569–1578 (2021)
[50] Ryali, C., Hu, Y.T., Bolya, D., Wei, C., Fan, H., Huang, P.Y., Aggarwal, V., Chowdhury, A., Poursaeed, O., Hoffman, J., et al.: Hiera: A hierarchical vision transformer without the bells-and-whistles. In: International conference on machine learning. pp. 29441–29454. PMLR (2023)
[51] Salter, S., Warren, R., Schlager, C., Spurr, A., Han, S., Bhasin, R., Cai, Y., Walkington, P., Bolarinwa, A., Wang, R., et al.: emg2pose: A large and diverse benchmark for surface electromyographic hand pose estimation. Advances in Neural Information Processing Systems 37, 55703–55728 (2024)
[52] Shamil, M.S., Chatterjee, D., Sener, F., Ma, S., Yao, A.: On the utility of 3d hand poses for action recognition. In: European Conference on Computer Vision. pp. 436–454. Springer (2024)
[53] Sivakumar, V., Seely, J., Du, A., Bittner, S.R., Berenzweig, A., Bolarinwa, A., Gramfort, A., Mandel, M.I.: emg2qwerty: A large dataset with baselines for touch typing using surface electromyography. In: NeurIPS (2024)
[54] Song, Y.R., Li, J., Fu, R., Murphy, D., Zhou, K., Shiv, R., Li, Y., Xiong, H., Owens, C.E., Du, Y., et al.: Opentouch: Bringing full-hand touch to real-world interaction. arXiv preprint arXiv:2512.16842 (2025)
[55] Spurr, A., Dahiya, A., Wang, X., Zhang, X., Hilliges, O.: Self-supervised 3d hand pose estimation from monocular rgb via contrastive learning. In: Proceedings of the IEEE/CVF international conference on computer vision. pp. 11230–11239 (2021)
[56] Thoker, F.M., Gall, J.: Cross-modal knowledge distillation for action recognition. In: 2019 IEEE International Conference on Image Processing (ICIP). pp. 6–10. IEEE (2019)
[57] Ting, J.E., Del Vecchio, A., Sarma, D., Verma, N., Colachis 4th, S.C., Annetta, N.V., Collinger, J.L., Farina, D., Weber, D.J.: Sensing and decoding the neural drive to paralyzed muscles during attempted movements of a person with tetraplegia using a sleeve array. Journal of neurophysiology 126(6), 2104–2118 (2021)
[58] Unterthiner, T., Van Steenkiste, S., Kurach, K., Marinier, R., Michalski, M., Gelly, S.: Fvd: A new metric for video generation (2019)
[59] Van Den Oord, A., Vinyals, O., et al.: Neural discrete representation learning. Advances in neural information processing systems 30 (2017)
[60] Wan, T., Wang, A., Ai, B., Wen, B., Mao, C., Xie, C.W., Chen, D., Yu, F., Zhao, H., Yang, J., et al.: Wan: Open and advanced large-scale video generative models. arXiv preprint arXiv:2503.20314 (2025)
[61] Wang, X., Zhang, R., Shen, C., Kong, T., Li, L.: Dense contrastive learning for self-supervised visual pre-training. In: Proceedings of the IEEE/CVF conference on computer vision and pattern recognition. pp. 3024–3033 (2021)
[62] Wang, Y., Li, K., Li, X., Yu, J., He, Y., Chen, G., Pei, B., Zheng, R., Wang, Z., Shi, Y., et al.: Internvideo2: Scaling foundation models for multimodal video understanding. In: European conference on computer vision. pp. 396–416. Springer (2024)
[63] Wu, Z., Li, B., Dai, J., Zhang, Y., Ma, Y., Wang, Q., Jia, X., Xu, H.: Video2lora: Unified semantic-controlled video generation via per-reference-video lora. arXiv preprint arXiv:2603.08210 (2026)
[64] Xi, Z., Yu, J., Wang, Y., Duan, Y., Feng, J., Zhou, J.: Egoemg: A multimodal egocentric dataset with bilateral emg and vision for hand pose estimation. arXiv preprint arXiv:2605.05712 (2026)
[65] Xie, Z., Lin, Y., Zhang, Z., Cao, Y., Lin, S., Hu, H.: Propagate yourself: Exploring pixel-level consistency for unsupervised visual representation learning. In: Proceedings of the IEEE/CVF conference on computer vision and pattern recognition. pp. 16684–16693 (2021)
[66] Yang, Z., Teng, J., Zheng, W., Ding, M., Huang, S., Xu, J., Yang, Y., Hong, W., Zhang, X., Feng, G., et al.: Cogvideox: Text-to-video diffusion models with an expert transformer. arXiv preprint arXiv:2408.06072 (2024)
[67] Yuan, S., Stenger, B., Kim, T.K.: Rgb-based 3d hand pose estimation via privileged learning with depth images. arXiv preprint arXiv:1811.07376 (2018)
[68] Zhang, H., Zhou, Y., Tian, Y., Yong, J.H., Xu, F.: Single depth view based real-time reconstruction of hand-object interactions. ACM Transactions on Graphics (TOG) 40(3), 1–12 (2021)
[69] Zhang, M., Huang, Y., Liu, R., Sato, Y.: Masked video and body-worn imu autoencoder for egocentric action recognition. In: European Conference on Computer Vision. pp. 312–330. Springer (2024)
[70] Zhang, R., Isola, P., Efros, A.A., Shechtman, E., Wang, O.: The unreasonable effectiveness of deep features as a perceptual metric. In: Proceedings of the IEEE conference on computer vision and pattern recognition. pp. 586–595 (2018)
[71] Zhang, Y., Gu, J., Wang, L.W., Wang, H., Cheng, J., Zhu, Y., Zou, F.: Mimicmotion: High-quality human motion video generation with confidence-aware pose guidance. arXiv preprint arXiv:2406.19680 (2024)
[72] Zhao, Y., Misra, I., Krähenbühl, P., Girdhar, R.: Learning video representations from large language models. In: Proceedings of the IEEE/CVF conference on computer vision and pattern recognition. pp. 6586–6597 (2023)
[73] Zheng, M., Crouch, M.S., Eggleston, M.S.: Surface electromyography as a natural human-machine interface: A review. IEEE Sensors Journal 22(10), 9198–9214 (2022)
[74] Zhou, J., Gao, Z., Hong, F., Liu, Z., Zhang, G., Dai, W., Zhen, R., Lyu, C., Wu, H., Mao, Y., et al.: Touchanything: A dataset and framework for bimanual tactile estimation from egocentric video. arXiv preprint arXiv:2605.13083 (2026)
[75] Zhu, L., Liu, X., Liu, X., Qian, R., Liu, Z., Yu, L.: Taming diffusion models for audio-driven co-speech gesture generation. In: Proceedings of the IEEE/CVF conference on computer vision and pattern recognition. pp. 10544–10553 (2023)
6 Appendix
6.1 Data Collection Protocol
Each MOTORSENSE recording session takes approximately one hour from setup to teardown and is organized into four stages, summarized in Figure 6. In the hardware setup stage, the participant installs the EMG streaming code on a recording laptop and installs Meta's Aria Studio on the same machine for later transfer of glasses recordings. Because the two MindRove armbands stream over separate Wi-Fi access points, each band is connected from a dedicated laptop to avoid stream collision. In the device fitting stage, the bands are placed slightly above each wrist rather than along the forearm; participants with larger forearms are prioritized, as the bands slip on slender wrists and produce motion artifacts that render the data unusable. The Aria glasses are then powered on, paired over Bluetooth to the participant's phone, and configured with our custom profile (RGB at 15 fps and 1440 × 1440, SLAM at 15 fps, audio and GPS on, eye tracking off, internet and Bluetooth disabled during recording). Before any task begins, the participant performs an isolated clench with each hand to confirm that both bands are mounted correctly, verifying distinct activation spikes on the per-hand visualizers. In the recording stage, the EMG stream and the Aria recording (started from the phone app) are launched together, and the participant proceeds with unscripted manipulation tasks. In the post-recording stage, the EMG window is closed, the Aria recording is stopped from the phone, the recording is transferred to the laptop via Aria Studio and then deleted from the glasses, and the glasses are placed on charge for the next session.
6.2 Dataset Details
Statistics. MOTORSENSE comprises 100 hours of synchronized egocentric video and bimanual EMG + IMU, all centered on unscripted kitchen and household manipulation. Recordings come from three capture setups: Project Aria Gen 1 glasses (18 recordings, 22.0 h), Project Aria Gen 2 glasses (19 recordings, 10.0 h), and a head-mounted smartphone with an ultra-wide camera (68.0 h). The Aria recordings were contributed by 8 participants; the smartphone sessions are not attributed to participants. All recordings are used, without labels, for contrastive pre-training. Action segments are annotated on 85 recordings (5,209 segments, 57 verbs, 180 nouns) and hand contact on 57 smartphone recordings (4,700 intervals), with held-out validation recordings for each.
Capture Hardware. Each forearm wears a MindRove armband with 8 dry EMG electrodes and a 6-axis IMU (accelerometer and gyroscope), streaming at 500 Hz over Wi-Fi. For the egocentric visual stream we use Meta's Project Aria device [18] (Gen 1 and Gen 2), whose forward-facing RGB camera is rectified to a pinhole model and resized (704 × 704 for Gen 1; 1280 × 960 or 1008 × 756 for Gen 2), or a head-mounted smartphone recording 896 × 504 frames at 30 fps. Video and EMG are placed on a single clock, so every frame is matched to the muscle activity of both arms.
Data Processing. For Aria recordings, we leverage Meta's Machine Perception Services (MPS) to extract 6-DoF camera trajectories and 3D hand tracking, from which we derive per-frame hand bounding boxes; for smartphone recordings, hand boxes come from an off-the-shelf hand detector.

Figure 6: The MOTORSENSE data collection workflow. Each session is organized into four stages, flowing left to right: hardware setup (connecting the two MindRove armbands over separate Wi-Fi access points and verifying installation of Aria Studio), device fitting (placing the bands slightly above each wrist, powering on and configuring the Aria glasses, and confirming correct mounting via a clench test), recording (launching the EMG and Aria streams together and proceeding with unscripted manipulation), and post-recording (stopping both streams, offloading Aria recordings via Aria Studio, and resetting the hardware for the next session).
Because the armbands stream over Wi-Fi, samples are occasionally lost; we drop training windows whose EMG contains gaps, saturation, or artifacts, removing about 4% of candidate windows.
To remove the low-frequency drift components from the EMG waveform, we apply a 4th-order zero-phase Butterworth high-pass filter at 10 Hz in line with existing approaches [51]. We then z-score normalize each EMG and IMU channel over the recording. We release the raw EMG and IMU streams, and this preprocessing is applied by our data loaders.
6.3 Implementation Details
6.3.1 Motor Code Discovery
The temporal encoder is a stack of strided one-dimensional convolutions interleaved with residual blocks, which downsample the signal along the time axis by a factor determined by a code rate of 64 codes per second. Lower rates force each token to encode longer spans of motor activity, whereas higher rates force each token to encode finer-grained motor activity. A convolution then projects each encoder output into the codebook's embedding space, and the quantizer replaces each projected latent with its nearest codebook entry; the codebook is updated by exponential moving averages of cluster assignments rather than by gradient descent, and gradients reach the encoder through a straight-through estimator (see [59] for details). Finally, the WaveNet-style decoder [45] upsamples the quantized latent sequence and reconstructs the input window.
We train the model with a reconstruction loss and a latent commitment penalty,
where is the input window, its reconstruction, the continuous pre-quantization latent, its vector-quantized counterpart (associated codebook embedding), the stop-gradient operator, and the latent commitment weight; the codebook vectors themselves are maintained by the EMA updates above rather than by this loss.
The EMG data (sampled at 500 Hz) is first preprocessed following Section 6.2 with a moving average window of 5 samples. We then train separate motor-code models for the left and right hand on the EMG recordings of MOTORSENSE. The VQ-VAE model ingests the processed EMG data over windows of length 1.5 s. We use an embedding dimension , a codebook of entries, and a target code rate (the number of codes per second) of 64. The latent commitment weight is set to . The model is optimized with a batch size of 128 over a single RTX A5000 GPU.
6.3.2 Video Diffusion
We instantiate the conditioning pipeline of Section 3.3 on top of the CogVideoX-Fun image-to-video backbone [66], which we keep entirely frozen throughout training together with its T5 text encoder and CogVideoX VAE. Each training sample is a 49-frame clip sampled at a frame rate of 15 FPS (the native frame rate) from the training split MOTORSENSE recordings, together with the paired bimanual motor-code sequences produced by the frozen tokenizers of Section 3.3. The clip's first frame is supplied as the image-to-video reference. The motor-code embedding network, the HyperNetwork, and the auxiliary LiLoRA matrices are the only trainable parameters. We train with AdamW at learning rate , batch size 1, for 30K steps on MOTORSENSE. All training was done over 4 H200 GPUs, with 128 GB of RAM.
6.3.3 Cross-Modal Contrastive Pre-training
Pre-training operates on pairs of egocentric video and bimanual EMG + IMU drawn from all MOTORSENSE recordings, with no action labels. Each sample is a 1.5 s window (during training the window duration is sampled from s in steps of 0.25 s): the RGB video is of shape , together with the bimanual EMG + IMU spanning the same interval extended by 1 s of context on each side. Windows whose EMG fails our signal-quality checks are discarded. When a hand is visible, we apply a consistent temporal crop that contains the hand with a random scale of the frame (otherwise a random crop with ), followed by color jitter and RandAugment.
The video tower is Hiera-Base initialized from MAE K400 pre-trained weights. We keep its 8 temporal positions, average over space, and apply a linear projection to the shared embedding space of dimension 1024. EMG and IMU are encoded by two separate signal towers of identical design, operating on the high-pass filtered (10 Hz) and standardized 500 Hz signals of both arms (16 EMG and 12 IMU channels). Each tower applies a temporal convolution followed by two residual depthwise-separable temporal blocks that downsample to ~50 Hz, a two-layer bidirectional LSTM over the full context window, and reads out the sequence at the 8 video time steps, followed by LayerNorm and a linear projection to the same 1024-d space. We apply no temporal pooling: each embedding is the flattened token sequence treated as a single vector. All outputs are -normalized as single vectors, and their cosine similarities are divided by a fixed temperature . We optimize the average of two symmetric InfoNCE losses, video–EMG and video–IMU, with embeddings gathered across all devices. Each global batch is drawn from a single recording using non-overlapping windows, so that negatives share the scene and participant.
We train with AdamW (weight decay 0.01) under a cosine schedule with 3 warmup epochs, using per-group learning rates (video backbone , video projection , EMG and IMU towers ), for 180 epochs at a global batch size of 328. Due to computational constraints, rather than jointly pre-training on K400 and MOTORSENSE, we instead initialize from K400 pre-trained weights, align over MOTORSENSE's data, and transfer the resulting EMG-aware representations to downstream tasks. Training was done on 4 H200 GPUs with 512 GB of RAM.
6.4 Pre-training Ablations
We ablate four design choices of our cross-modal pre-training: (i) the sensing modalities used for alignment, (ii) the number of EMG electrodes, (iii) how batches are formed, and (iv) whether embeddings are pooled over time before the contrastive loss. We transfer each backbone to action recognition on EPIC-KITCHENS-100 and MotorSense under frozen and fine-tuned evaluation, following Section 4.1, with a single seed per evaluation.
| Ablation | Variant | EPIC-KITCHENS-100 | MotorSense | ||
|---|---|---|---|---|---|
| Frozen | Fine-tuned | Frozen | Fine-tuned | ||
| - | K400 init. | 9.93 | 40.06 | 16.86 | 42.22 |
| - | Ours (reference) | 21.29 | 43.81 | 35.02 | 47.51 |
| Modalities | EMG only | 16.33 | 41.27 | 30.46 | 45.29 |
| IMU only | 15.36 | 41.10 | 25.48 | 43.26 | |
| Electrodes | 4 per arm | 18.88 | 41.86 | 31.57 | 44.62 |
| 2 per arm | 19.29 | 41.80 | 31.82 | 44.98 | |
| Batching | Mixed recordings | 18.21 | 42.20 | 29.29 | 46.46 |
| Pooling | Temporal mean | 17.64 | 41.84 | 32.55 | 44.86 |
Table 5: Pre-training ablations. Action top-1 accuracy on EPIC-KITCHENS-100 and MotorSense with a Hiera-B backbone; each ablated row changes a single setting of the reference (EMG+IMU, 8 electrodes per arm, same-recording batches, time-resolved embeddings). Single seed per evaluation. Best pre-trained result per column in bold.
6.5 Video Diffusion Sequences
In Figures 7, 8, and 9 we show qualitative visualizations comparing the original RGB video with the generated video over both the Video History Conditioning as well as our proposed Motor Code Conditioning. Visualizations and evaluations are performed over bounding box crops centered on the hands, as opposed to the entirety of the original RGB video.

Figure 7: Qualitative results for video diffusion. We compare our proposed motor conditioning to a video diffusion model conditioned solely on the video history (unimodal conditioning), for a sequence involving the stirring of tofu in a pan. The video conditioning model misinterprets the action performed, generating a video of a scooping action as opposed to a stirring action, whereas our method correctly generates a video of the stirring of tofu.

Figure 8: Qualitative results for video diffusion. We compare our proposed motor conditioning to a video diffusion model conditioned solely on the video history (unimodal conditioning), for a sequence involving the spreading of mayonnaise with a spoon. The video conditioning model misinterprets the action performed, generating a rotation of the bread as opposed to a spreading action of the spoon, whereas our method correctly generates a video of the spreading of mayonnaise with a spoon.

Figure 9: Qualitative results for video diffusion. We compare our proposed motor conditioning to a video diffusion model conditioned solely on the video history (unimodal conditioning), for a bimanual manipulation sequence involving the peeling of an avocado. The video conditioning model renders the index finger as resting against the thumb, whereas our method correctly positions the index finger against the surface of the avocado for the peeling action.
NeurIPS Paper Checklist
1. Claims
Question: Do the main claims made in the abstract and introduction accurately reflect the paper's contributions and scope?
Answer: [Yes]
Justification: The paper introduces MOTORSENSE, a dataset pairing egocentric video with bimanual surface EMG and IMU, and evaluates representations learned from it across action recognition, 3D hand reconstruction, hand contact reconstruction, and motor-conditioned video diffusion. Following the review process, the dataset claims have been narrowed: we no longer describe MOTORSENSE as the first paired video–EMG dataset (ActionSense [13] precedes it; the differences are discussed in Section 2 and the Appendix), we state explicitly that the participant pool is not population-representative, and claims about cross-subject generalization are limited to what the held-out-participant and cross-domain evaluations in the Appendix support. All experimental claims are covered in Section 4, with implementation details and ablations in the Appendix.
Guidelines:
-
The answer [N/A] means that the abstract and introduction do not include the claims made in the paper.
-
The abstract and/or introduction should clearly state the claims made, including the contributions made in the paper and important assumptions and limitations. A [No] or [N/A] answer to this question will not be perceived well by the reviewers.
-
The claims made should match theoretical and experimental results, and reflect how much the results can be expected to generalize to other settings.
-
It is fine to include aspirational goals as motivation as long as it is clear that these goals are not attained by the paper.
2. Limitations
Question: Does the paper discuss the limitations of the work performed by the authors?
Answer: [Yes]
Justification: Limitations are discussed in the Discussion section and in an expanded Limitations section in the Appendix. Beyond the 8-channel consumer-grade EMG hardware, we discuss: (i) the small participant pool; (ii) selection bias with respect to forearm circumference, which arises from the mechanical mounting of the MindRove bands (the bands slip on slender wrists and produce unusable data) and which correlates with sex and body size, so that MOTORSENSE should not be read as population-representative; (iii) the effect of anatomical variation on EMG amplitude and electrode–muscle correspondence, and its implications for motor-code prediction; (iv) the scope of our cross-subject evaluation, which covers motor-code prediction on held-out participants but not downstream subject-disjoint evaluation of action recognition or 3D reconstruction; (v) the larger performance drop under activity-domain shift (assembly, cleaning, laundry) than under subject shift; (vi) the role of IMU in stabilizing the EMG signal under rapid wrist motion; and (vii) privacy and biometric considerations of releasing egocentric video and physiological EMG. Dataset statistics and compute are reported in the Experiments section and Appendix.
Guidelines:
-
The answer [N/A] means that the paper has no limitation while the answer [No] means that the paper has limitations, but those are not discussed in the paper.
-
The authors are encouraged to create a separate "Limitations" section in their paper.
-
The paper should point out any strong assumptions and how robust the results are to violations of these assumptions (e.g., independence assumptions, noiseless settings, model well-specification, asymptotic approximations only holding locally). The authors should reflect on how these assumptions might be violated in practice and what the implications would be.
-
The authors should reflect on the scope of the claims made, e.g., if the approach was only tested on a few datasets or with a few runs. In general, empirical results often depend on implicit assumptions, which should be articulated.
-
The authors should reflect on the factors that influence the performance of the approach. For example, a facial recognition algorithm may perform poorly when image resolution is low or images are taken in low lighting. Or a speech-to-text system might not be used reliably to provide closed captions for online lectures because it fails to handle technical jargon.
-
The authors should discuss the computational efficiency of the proposed algorithms and how they scale with dataset size.
-
If applicable, the authors should discuss possible limitations of their approach to address problems of privacy and fairness.
-
While the authors might fear that complete honesty about limitations might be used by reviewers as grounds for rejection, a worse outcome might be that reviewers discover limitations that aren't acknowledged in the paper. The authors should use their best judgment and recognize that individual actions in favor of transparency play an important role in developing norms that preserve the integrity of the community. Reviewers will be specifically instructed to not penalize honesty concerning limitations.
3. Theory assumptions and proofs
Question: For each theoretical result, does the paper provide the full set of assumptions and a complete (and correct) proof?
Answer: [N/A]
Justification: No theoretical results were included. Our paper is not on the theory track.
Guidelines:
- The answer [N/A] means that the paper does not include theoretical results.
- All the theorems, formulas, and proofs in the paper should be numbered and cross-referenced.
- All assumptions should be clearly stated or referenced in the statement of any theorems.
- The proofs can either appear in the main paper or the supplemental material, but if they appear in the supplemental material, the authors are encouraged to provide a short proof sketch to provide intuition.
- Inversely, any informal proof provided in the core of the paper should be complemented by formal proofs provided in appendix or supplemental material.
- Theorems and Lemmas that the proof relies upon should be properly referenced.
4. Experimental result reproducibility
Question: Does the paper fully disclose all the information needed to reproduce the main experimental results of the paper to the extent that it affects the main claims and/or conclusions of the paper (regardless of whether the code and data are provided or not)?
Answer: [Yes]
Justification: The Methods, Experiments, and Appendix contain all information needed to reproduce our results, including data preprocessing, architectures, optimizers, schedules, and splits. The dataset, trained models, and training code are released (see Questions 5 and 13). For implementation details inherited from prior work, we refer the reader to the relevant source throughout the paper (e.g., "we refer the reader to Video2LoRA [63] for...").
Guidelines:
- The answer [N/A] means that the paper does not include experiments.
- If the paper includes experiments, a [No] answer to this question will not be perceived well by the reviewers: Making the paper reproducible is important, regardless of whether the code and data are provided or not.
- If the contribution is a dataset and/or model, the authors should describe the steps taken to make their results reproducible or verifiable.
- Depending on the contribution, reproducibility can be accomplished in various ways. For example, if the contribution is a novel architecture, describing the architecture fully might suffice, or if the contribution is a specific model and empirical evaluation, it may be necessary to either make it possible for others to replicate the model with the same dataset, or provide access to the model. In general, releasing code and data is often
one good way to accomplish this, but reproducibility can also be provided via detailed instructions for how to replicate the results, access to a hosted model (e.g., in the case of a large language model), releasing of a model checkpoint, or other means that are appropriate to the research performed.
- While NeurIPS does not require releasing code, the conference does require all submissions to provide some reasonable avenue for reproducibility, which may depend on the nature of the contribution. For example
(a) If the contribution is primarily a new algorithm, the paper should make it clear how to reproduce that algorithm.
(b) If the contribution is primarily a new model architecture, the paper should describe the architecture clearly and fully.
(c) If the contribution is a new model (e.g., a large language model), then there should either be a way to access this model for reproducing the results or a way to reproduce the model (e.g., with an open-source dataset or instructions for how to construct the dataset).
(d) We recognize that reproducibility may be tricky in some cases, in which case authors are welcome to describe the particular way they provide for reproducibility. In the case of closed-source models, it may be that access to the model is limited in some way (e.g., to registered users), but it should be possible for other researchers to have some path to reproducing or verifying the results.
5. Open access to data and code
Question: Does the paper provide open access to the data and code, with sufficient instructions to faithfully reproduce the main experimental results, as described in supplemental material?
Answer: [Yes]
Justification: We release the MOTORSENSE dataset (synchronized video, bimanual EMG and IMU, audio, derived spectrograms, and MPS-derived camera and hand pose), the trained models, and the training and evaluation code, together with instructions for reproducing the experiments, at https://anonymous.4open.science/r/MotorSense-7173/.
Guidelines:
-
The answer [N/A] means that paper does not include experiments requiring code.
-
Please see the NeurIPS code and data submission guidelines (https://neurips.cc/public/guides/CodeSubmissionPolicy) for more details.
-
While we encourage the release of code and data, we understand that this might not be possible, so [No] is an acceptable answer. Papers cannot be rejected simply for not including code, unless this is central to the contribution (e.g., for a new open-source benchmark).
-
The instructions should contain the exact command and environment needed to run to reproduce the results. See the NeurIPS code and data submission guidelines (https://neurips.cc/public/guides/CodeSubmissionPolicy) for more details.
-
The authors should provide instructions on data access and preparation, including how to access the raw data, preprocessed data, intermediate data, and generated data, etc.
-
The authors should provide scripts to reproduce all experimental results for the new proposed method and baselines. If only a subset of experiments are reproducible, they should state which ones are omitted from the script and why.
-
At submission time, to preserve anonymity, the authors should release anonymized versions (if applicable).
-
Providing as much information as possible in supplemental material (appended to the paper) is recommended, but including URLs to data and code is permitted.
6. Experimental setting/details
Question: Does the paper specify all the training and test details (e.g., data splits, hyperparameters, how they were chosen, type of optimizer) necessary to understand the results?
Answer: [Yes]
Justification: Data splits (including the held-out-environment validation split and the held-out-participant and cross-domain evaluation splits), hyperparameters, optimizers, schedules, and model selection criteria are given in the Experiments section and in the Implementation Details and ablation sections of the Appendix.
Guidelines:
-
The answer [N/A] means that the paper does not include experiments.
-
The experimental setting should be presented in the core of the paper to a level of detail that is necessary to appreciate the results and make sense of them.
-
The full details can be provided either with the code, in appendix, or as supplemental material.
7. Experiment statistical significance
Question: Does the paper report error bars suitably and correctly defined or other appropriate information about the statistical significance of the experiments?
Answer: [Yes]
Justification: Error bars (mean ± standard deviation over three training seeds) are reported for the hand contact reconstruction experiments (Table 3).
Guidelines:
-
The answer [N/A] means that the paper does not include experiments.
-
The authors should answer [Yes] if the results are accompanied by error bars, confidence intervals, or statistical significance tests, at least for the experiments that support the main claims of the paper.
-
The factors of variability that the error bars are capturing should be clearly stated (for example, train/test split, initialization, random drawing of some parameter, or overall run with given experimental conditions).
-
The method for calculating the error bars should be explained (closed form formula, call to a library function, bootstrap, etc.)
-
The assumptions made should be given (e.g., Normally distributed errors).
-
It should be clear whether the error bar is the standard deviation or the standard error of the mean.
-
It is OK to report 1-sigma error bars, but one should state it. The authors should preferably report a 2-sigma error bar than state that they have a 96% CI, if the hypothesis of Normality of errors is not verified.
-
For asymmetric distributions, the authors should be careful not to show in tables or figures symmetric error bars that would yield results that are out of range (e.g., negative error rates).
-
If error bars are reported in tables or plots, the authors should explain in the text how they were calculated and reference the corresponding figures or tables in the text.
8. Experiments compute resources
Question: For each experiment, does the paper provide sufficient information on the computer resources (type of compute workers, memory, time of execution) needed to reproduce the experiments?
Answer: [Yes]
Justification: The GPU type, number of GPUs, and memory used for each experiment (motor-code discovery, cross-modal pre-training, and video diffusion) are reported in the Implementation Details section of the Appendix.
Guidelines:
-
The answer [N/A] means that the paper does not include experiments.
-
The paper should indicate the type of compute workers CPU or GPU, internal cluster, or cloud provider, including relevant memory and storage.
-
The paper should provide the amount of compute required for each of the individual experimental runs as well as estimate the total compute.
-
The paper should disclose whether the full research project required more compute than the experiments reported in the paper (e.g., preliminary or failed experiments that didn't make it into the paper).
9. Code of ethics
Question: Does the research conducted in the paper conform, in every respect, with the NeurIPS Code of Ethics https://neurips.cc/public/EthicsGuidelines?
Answer: [Yes]
Justification: The data collection was reviewed and approved by our institution's IRB; all participants gave written informed consent covering research use, public release, and reproduction of frames and clips in publications; participants were compensated; risks were disclosed; and the released data were screened and de-identified before release. These procedures are documented in the Appendix and in Questions 11, 14, and 15 below.
Guidelines:
-
The answer [N/A] means that the authors have not reviewed the NeurIPS Code of Ethics.
-
If the authors answer [No], they should explain the special circumstances that require a deviation from the Code of Ethics.
-
The authors should make sure to preserve anonymity (e.g., if there is a special consideration due to laws or regulations in their jurisdiction).
10. Broader impacts
Question: Does the paper discuss both potential positive societal impacts and negative societal impacts of the work performed?
Answer: [Yes]
Justification: Positive impacts (VR/AR, assistive and rehabilitative technology, surgical training, human-robot collaboration) are discussed in the Broader Impact paragraph of the Discussion. Negative impacts are discussed in the Limitations section of the Appendix: the privacy risk of egocentric recording in home environments, the sensitivity of EMG as a physiological signal, and the risk that models trained on a non-representative participant pool perform worse for under-represented body types. The mitigations we applied to the release are described under Safeguards below.
Guidelines:
-
The answer [N/A] means that there is no societal impact of the work performed.
-
If the authors answer [N/A] or [No], they should explain why their work has no societal impact or why the paper does not address societal impact.
-
Examples of negative societal impacts include potential malicious or unintended uses (e.g., disinformation, generating fake profiles, surveillance), fairness considerations (e.g., deployment of technologies that could make decisions that unfairly impact specific groups), privacy considerations, and security considerations.
-
The conference expects that many papers will be foundational research and not tied to particular applications, let alone deployments. However, if there is a direct path to any negative applications, the authors should point it out. For example, it is legitimate to point out that an improvement in the quality of generative models could be used to generate Deepfakes for disinformation. On the other hand, it is not needed to point out that a generic algorithm for optimizing neural networks could enable people to train models that generate Deepfakes faster.
-
The authors should consider possible harms that could arise when the technology is being used as intended and functioning correctly, harms that could arise when the technology is being used as intended but gives incorrect results, and harms following from (intentional or unintentional) misuse of the technology.
-
If there are negative societal impacts, the authors could also discuss possible mitigation strategies (e.g., gated release of models, providing defenses in addition to attacks, mechanisms for monitoring misuse, mechanisms to monitor how a system learns from feedback over time, improving the efficiency and accessibility of ML).
11. Safeguards
Question: Does the paper describe safeguards that have been put in place for responsible release of data or models that have a high risk for misuse (e.g., pre-trained language models, image generators, or scraped datasets)?
Answer: [Yes]
Justification: The released dataset contains egocentric video recorded in participants' homes, so we applied a documented release protocol described in the Appendix: participants recorded alone and were instructed that no other person be present, and manual review confirmed that no bystanders appear in the released recordings; participants were instructed not to speak, and the small number of segments containing inadvertent speech were removed; location and raw GPS metadata are not included in the release; and every recording was screened and de-identified before release by a combination of manual review and EgoBlur [?], targeting faces and other identifying content. The dataset is released under research-use terms stated in the Appendix and alongside the data.
Guidelines:
• The answer [N/A] means that the paper poses no such risks.
• Released models that have a high risk for misuse or dual-use should be released with necessary safeguards to allow for controlled use of the model, for example by requiring that users adhere to usage guidelines or restrictions to access the model or implementing safety filters.
• Datasets that have been scraped from the Internet could pose safety risks. The authors should describe how they avoided releasing unsafe images.
• We recognize that providing effective safeguards is challenging, and many papers do not require this, but we encourage authors to take this into account and make a best faith effort.
12. Licenses for existing assets
Question: Are the creators or original owners of assets (e.g., code, data, models), used in the paper, properly credited and are the license and terms of use explicitly mentioned and properly respected?
Answer: [Yes]
Justification: All existing datasets (EPIC-Kitchens-100 [10], Something-Something v2 [26], Ego-Exo4D [28], Meccano [49], ARCTIC [20], H2O [34], HOT3D [3]), pre-trained models (Hiera [50], EgoVideo, DINOv3, CogVideoX [66]), code (Video2LoRA [63], and hardware/services (Project Aria and MPS [18], MindRove) are cited where used.
Guidelines:
• The answer [N/A] means that the paper does not use existing assets.
• The authors should cite the original paper that produced the code package or dataset.
• The authors should state which version of the asset is used and, if possible, include a URL.
• The name of the license (e.g., CC-BY 4.0) should be included for each asset.
• For scraped data from a particular source (e.g., website), the copyright and terms of service of that source should be provided.
• If assets are released, the license, copyright information, and terms of use in the package should be provided. For popular datasets, paperswithcode.com/datasets has curated licenses for some datasets. Their licensing guide can help determine the license of a dataset.
• For existing datasets that are re-packaged, both the original license and the license of the derived asset (if it has changed) should be provided.
• If this information is not available online, the authors are encouraged to reach out to the asset's creators.
13. New assets
Question: Are new assets introduced in the paper well documented and is the documentation provided alongside the assets?
Answer: [Yes]
Justification: We release three new assets: the MOTORSENSE dataset, the trained models (EMG motor-code tokenizers, video–EMG aligned backbones, and the motor-conditioned diffusion adapters), and the training and evaluation code. The dataset is documented in the Appendix (collection protocol, participant instructions, statistics, preprocessing, splits, consent and de-identification procedures, known limitations and selection bias, and license/terms of use), and the same documentation, together with usage instructions, is provided alongside the assets at the release URL. Consent for research use and public release was obtained in writing from every participant.
Guidelines:
-
The answer [N/A] means that the paper does not release new assets.
-
Researchers should communicate the details of the dataset/code/model as part of their submissions via structured templates. This includes details about training, license, limitations, etc.
-
The paper should discuss whether and how consent was obtained from people whose asset is used.
-
At submission time, remember to anonymize your assets (if applicable). You can either create an anonymized URL or include an anonymized zip file.
14. Crowdsourcing and research with human subjects
Question: For crowdsourcing experiments and research with human subjects, does the paper include the full text of instructions given to participants and screenshots, if applicable, as well as details about compensation (if any)?
Answer: [Yes]
Justification: The full instructions given to participants are included in the Appendix. They cover installation and connection of the EMG streaming software, band placement on each wrist, the clench verification test used to confirm correct mounting, Aria glasses configuration and recording start/stop, session length, the requirement to record alone with no other person present and without speaking, and the post-recording offload procedure. Participants were recruited by convenience through word of mouth within the authors' institutional network of students, screened only for device-fit suitability and willingness to record cooking activity, and received a fixed payment of $25 per recording session plus reimbursement for food used during cooking.
Guidelines:
-
The answer [N/A] means that the paper does not involve crowdsourcing nor research with human subjects.
-
Including this information in the supplemental material is fine, but if the main contribution of the paper involves human subjects, then as much detail as possible should be included in the main paper.
-
According to the NeurIPS Code of Ethics, workers involved in data collection, curation, or other labor should be paid at least the minimum wage in the country of the data collector.
15. Institutional review board (IRB) approvals or equivalent for research with human subjects
Question: Does the paper describe potential risks incurred by study participants, whether such risks were disclosed to the subjects, and whether Institutional Review Board (IRB) approvals (or an equivalent approval/review based on the requirements of your country or institution) were obtained?
Answer: [Yes]
Justification: The data collection was reviewed and approved by our institution's IRB under two sequential protocols: the first protocol expired during the project timeline, and a second protocol was approved before the corresponding later sessions began, so every stage of collection was covered by an active approval. Participants were informed of the risks of the procedure before recording: minor skin irritation from the dry electrodes and band pressure, discomfort from extended wear, and the privacy risk of egocentric recording in their own home environment. All participants gave written informed consent covering participation, research use of the recorded video, audio, EMG, IMU, and derived data, public release of that data as a research dataset, and reproduction of individual frames and clips in publications and presentations, and were told they could withdraw at any point during collection. Full details are in the Appendix.
Guidelines:
-
The answer [N/A] means that the paper does not involve crowdsourcing nor research with human subjects.
-
Depending on the country in which research is conducted, IRB approval (or equivalent) may be required for any human subjects research. If you obtained IRB approval, you should clearly state this in the paper.
-
We recognize that the procedures for this may vary significantly between institutions and locations, and we expect authors to adhere to the NeurIPS Code of Ethics and the guidelines for their institution.
-
For initial submissions, do not include any information that would break anonymity (if applicable), such as the institution conducting the review.
16. Declaration of LLM usage
Question: Does the paper describe the usage of LLMs if it is an important, original, or non-standard component of the core methods in this research? Note that if the LLM is used only for writing, editing, or formatting purposes and does not impact the core methodology, scientific rigor, or originality of the research, declaration is not required.
Answer: [N/A]
Justification: LLMs were used only for data processing and filtering and for writing assistance; they are not a component of the proposed method, the motor-code representation, the contrastive pre-training, or the evaluation.
Guidelines:
-
The answer [N/A] means that the core method development in this research does not involve LLMs as any important, original, or non-standard components.
-
Please refer to our LLM policy in the NeurIPS handbook for what should or should not be described.